Aspiration of tracheoesophageal prosthesis in a laryngectomized patient

Background The voice prosthesis inserted into a tracheoesophageal fistula has become the most widely used device for voice rehabilitation in patients with total laryngectomy. Case presentation We describe a case of tracheoesophageal prosthesis’ (TEP) aspiration in a laryngectomized patient, with per...

Celý popis

Uložené v:
Podrobná bibliografia
Vydané v:Multidisciplinary respiratory medicine Ročník 7; číslo 1; s. 25
Hlavní autori: Conte, Sergio C, De Nardi, Elena, Conte, Federico, Nardini, Stefano
Médium: Journal Article
Jazyk:English
Vydavateľské údaje: London BioMed Central 09.08.2012
BioMed Central Ltd
Mattioli 1885
Predmet:
ISSN:2049-6958, 1828-695X, 2049-6958
On-line prístup:Získať plný text
Tagy: Pridať tag
Žiadne tagy, Buďte prvý, kto otaguje tento záznam!
Popis
Shrnutí:Background The voice prosthesis inserted into a tracheoesophageal fistula has become the most widely used device for voice rehabilitation in patients with total laryngectomy. Case presentation We describe a case of tracheoesophageal prosthesis’ (TEP) aspiration in a laryngectomized patient, with permanent tracheal stoma, that appeared during standard cleaning procedure, despite a programme of training for the safe management of patients with voice prosthesis. Conclusions The definitive diagnosis and treatment were performed by flexible bronchoscopy, that may be considered the procedure of choice in these cases, also on the basis of the literature.