Analysis of Different Device-Based Intrathoracic Impedance Vectors for Detection of Heart Failure Events (from the Detect Fluid Early from Intrathoracic Impedance Monitoring Study)

Detect Fluid Early from Intrathoracic Impedance Monitoring (DEFEAT-PE) is a prospective, multicenter study of multiple intrathoracic impedance vectors to detect pulmonary congestion (PC) events. Changes in intrathoracic impedance between the right ventricular (RV) coil and device can (RVcoil→Can) of...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The American journal of cardiology Jg. 114; H. 8; S. 1249 - 1256
Hauptverfasser: Heist, E. Kevin, Herre, John M., Binkley, Philip F., Van Bakel, Adrian B., Porterfield, James G., Porterfield, Linda M., Qu, Fujian, Turkel, Melanie, Pavri, Behzad B.
Format: Journal Article
Sprache:Englisch
Veröffentlicht: United States Elsevier Inc 15.10.2014
Elsevier Limited
Schlagworte:
ISSN:0002-9149, 1879-1913, 1879-1913
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Abstract Detect Fluid Early from Intrathoracic Impedance Monitoring (DEFEAT-PE) is a prospective, multicenter study of multiple intrathoracic impedance vectors to detect pulmonary congestion (PC) events. Changes in intrathoracic impedance between the right ventricular (RV) coil and device can (RVcoil→Can) of implantable cardioverter-defibrillators (ICDs) and cardiac resynchronization therapy ICDs (CRT-Ds) are used clinically for the detection of PC events, but other impedance vectors and algorithms have not been studied prospectively. An initial 75-patient study was used to derive optimal impedance vectors to detect PC events, with 2 vector combinations selected for prospective analysis in DEFEAT-PE (ICD vectors: RVring→Can + RVcoil→Can, detection threshold 13 days; CRT-D vectors: left ventricular ring→Can + RVcoil→Can, detection threshold 14 days). Impedance changes were considered true positive if detected <30 days before an adjudicated PC event. One hundred sixty-two patients were enrolled (80 with ICDs and 82 with CRT-Ds), all with ≥1 previous PC event. One hundred forty-four patients provided study data, with 214 patient-years of follow-up and 139 PC events. Sensitivity for PC events of the prespecified algorithms was as follows: ICD: sensitivity 32.3%, false-positive rate 1.28 per patient-year; CRT-D: sensitivity 32.4%, false-positive rate 1.66 per patient-year. An alternative algorithm, ultimately approved by the US Food and Drug Administration (RVring→Can + RVcoil→Can, detection threshold 14 days), resulted in (for all patients) sensitivity of 21.6% and a false-positive rate of 0.9 per patient-year. The CRT-D thoracic impedance vector algorithm selected in the derivation study was not superior to the ICD algorithm RVring→Can + RVcoil→Can when studied prospectively. In conclusion, to achieve an acceptably low false-positive rate, the intrathoracic impedance algorithms studied in DEFEAT-PE resulted in low sensitivity for the prediction of heart failure events. •Prediction of CHF on the basis of thoracic impedance was examined.•Impedance vectors from RV and LV leads were evaluated in ICD and CRT patients.•Algorithms producing low false-positive rates had low sensitivity to detect CHF.•Algorithms including LV and RV leads were not superior to RV lead–only algorithms.•An algorithm involving the RV lead and can was FDA approved on the basis of this study.
AbstractList Detect Fluid Early from Intrathoracic Impedance Monitoring (DEFEAT-PE) is a prospective, multicenter study of multiple intrathoracic impedance vectors to detect pulmonary congestion (PC) events. Changes in intrathoracic impedance between the right ventricular (RV) coil and device can (RVcoil→Can) of implantable cardioverter-defibrillators (ICDs) and cardiac resynchronization therapy ICDs (CRT-Ds) are used clinically for the detection of PC events, but other impedance vectors and algorithms have not been studied prospectively. An initial 75-patient study was used to derive optimal impedance vectors to detect PC events, with 2 vector combinations selected for prospective analysis in DEFEAT-PE (ICD vectors: RVring→Can + RVcoil→Can, detection threshold 13 days; CRT-D vectors: left ventricular ring→Can + RVcoil→Can, detection threshold 14 days). Impedance changes were considered true positive if detected <30 days before an adjudicated PC event. One hundred sixty-two patients were enrolled (80 with ICDs and 82 with CRT-Ds), all with ≥1 previous PC event. One hundred forty-four patients provided study data, with 214 patient-years of follow-up and 139 PC events. Sensitivity for PC events of the prespecified algorithms was as follows: ICD: sensitivity 32.3%, false-positive rate 1.28 per patient-year; CRT-D: sensitivity 32.4%, false-positive rate 1.66 per patient-year. An alternative algorithm, ultimately approved by the US Food and Drug Administration (RVring→Can + RVcoil→Can, detection threshold 14 days), resulted in (for all patients) sensitivity of 21.6% and a false-positive rate of 0.9 per patient-year. The CRT-D thoracic impedance vector algorithm selected in the derivation study was not superior to the ICD algorithm RVring→Can + RVcoil→Can when studied prospectively. In conclusion, to achieve an acceptably low false-positive rate, the intrathoracic impedance algorithms studied in DEFEAT-PE resulted in low sensitivity for the prediction of heart failure events. •Prediction of CHF on the basis of thoracic impedance was examined.•Impedance vectors from RV and LV leads were evaluated in ICD and CRT patients.•Algorithms producing low false-positive rates had low sensitivity to detect CHF.•Algorithms including LV and RV leads were not superior to RV lead–only algorithms.•An algorithm involving the RV lead and can was FDA approved on the basis of this study.
Detect Fluid Early from Intrathoracic Impedance Monitoring (DEFEAT-PE) is a prospective, multicenter study of multiple intrathoracic impedance vectors to detect pulmonary congestion (PC) events. Changes in intrathoracic impedance between the right ventricular (RV) coil and device can (RVcoil→Can) of implantable cardioverter-defibrillators (ICDs) and cardiac resynchronization therapy ICDs (CRT-Ds) are used clinically for the detection of PC events, but other impedance vectors and algorithms have not been studied prospectively. An initial 75-patient study was used to derive optimal impedance vectors to detect PC events, with 2 vector combinations selected for prospective analysis in DEFEAT-PE (ICD vectors: RVring→Can + RVcoil→Can, detection threshold 13 days; CRT-D vectors: left ventricular ring→Can + RVcoil→Can, detection threshold 14 days). Impedance changes were considered true positive if detected <30 days before an adjudicated PC event. One hundred sixty-two patients were enrolled (80 with ICDs and 82 with CRT-Ds), all with ≥1 previous PC event. One hundred forty-four patients provided study data, with 214 patient-years of follow-up and 139 PC events. Sensitivity for PC events of the prespecified algorithms was as follows: ICD: sensitivity 32.3%, false-positive rate 1.28 per patient-year; CRT-D: sensitivity 32.4%, false-positive rate 1.66 per patient-year. An alternative algorithm, ultimately approved by the US Food and Drug Administration (RVring→Can + RVcoil→Can, detection threshold 14 days), resulted in (for all patients) sensitivity of 21.6% and a false-positive rate of 0.9 per patient-year. The CRT-D thoracic impedance vector algorithm selected in the derivation study was not superior to the ICD algorithm RVring→Can + RVcoil→Can when studied prospectively. In conclusion, to achieve an acceptably low false-positive rate, the intrathoracic impedance algorithms studied in DEFEAT-PE resulted in low sensitivity for the prediction of heart failure events.
Detect Fluid Early from Intrathoracic Impedance Monitoring (DEFEAT-PE) is a prospective, multicenter study of multiple intrathoracic impedance vectors to detect pulmonary congestion (PC) events. Changes in intrathoracic impedance between the right ventricular (RV) coil and device can (RVcoil→Can) of implantable cardioverter-defibrillators (ICDs) and cardiac resynchronization therapy ICDs (CRT-Ds) are used clinically for the detection of PC events, but other impedance vectors and algorithms have not been studied prospectively. An initial 75-patient study was used to derive optimal impedance vectors to detect PC events, with 2 vector combinations selected for prospective analysis in DEFEAT-PE (ICD vectors: RVring→Can + RVcoil→Can, detection threshold 13 days; CRT-D vectors: left ventricular ring→Can + RVcoil→Can, detection threshold 14 days). Impedance changes were considered true positive if detected <30 days before an adjudicated PC event. One hundred sixty-two patients were enrolled (80 with ICDs and 82 with CRT-Ds), all with ≥1 previous PC event. One hundred forty-four patients provided study data, with 214 patient-years of follow-up and 139 PC events. Sensitivity for PC events of the prespecified algorithms was as follows: ICD: sensitivity 32.3%, false-positive rate 1.28 per patient-year; CRT-D: sensitivity 32.4%, false-positive rate 1.66 per patient-year. An alternative algorithm, ultimately approved by the US Food and Drug Administration (RVring→Can + RVcoil→Can, detection threshold 14 days), resulted in (for all patients) sensitivity of 21.6% and a false-positive rate of 0.9 per patient-year. The CRT-D thoracic impedance vector algorithm selected in the derivation study was not superior to the ICD algorithm RVring→Can + RVcoil→Can when studied prospectively. In conclusion, to achieve an acceptably low false-positive rate, the intrathoracic impedance algorithms studied in DEFEAT-PE resulted in low sensitivity for the prediction of heart failure events.Detect Fluid Early from Intrathoracic Impedance Monitoring (DEFEAT-PE) is a prospective, multicenter study of multiple intrathoracic impedance vectors to detect pulmonary congestion (PC) events. Changes in intrathoracic impedance between the right ventricular (RV) coil and device can (RVcoil→Can) of implantable cardioverter-defibrillators (ICDs) and cardiac resynchronization therapy ICDs (CRT-Ds) are used clinically for the detection of PC events, but other impedance vectors and algorithms have not been studied prospectively. An initial 75-patient study was used to derive optimal impedance vectors to detect PC events, with 2 vector combinations selected for prospective analysis in DEFEAT-PE (ICD vectors: RVring→Can + RVcoil→Can, detection threshold 13 days; CRT-D vectors: left ventricular ring→Can + RVcoil→Can, detection threshold 14 days). Impedance changes were considered true positive if detected <30 days before an adjudicated PC event. One hundred sixty-two patients were enrolled (80 with ICDs and 82 with CRT-Ds), all with ≥1 previous PC event. One hundred forty-four patients provided study data, with 214 patient-years of follow-up and 139 PC events. Sensitivity for PC events of the prespecified algorithms was as follows: ICD: sensitivity 32.3%, false-positive rate 1.28 per patient-year; CRT-D: sensitivity 32.4%, false-positive rate 1.66 per patient-year. An alternative algorithm, ultimately approved by the US Food and Drug Administration (RVring→Can + RVcoil→Can, detection threshold 14 days), resulted in (for all patients) sensitivity of 21.6% and a false-positive rate of 0.9 per patient-year. The CRT-D thoracic impedance vector algorithm selected in the derivation study was not superior to the ICD algorithm RVring→Can + RVcoil→Can when studied prospectively. In conclusion, to achieve an acceptably low false-positive rate, the intrathoracic impedance algorithms studied in DEFEAT-PE resulted in low sensitivity for the prediction of heart failure events.
Detect Fluid Early from Intrathoracic Impedance Monitoring (DEFEAT-PE) is a prospective, multicenter study of multiple intrathoracic impedance vectors to detect pulmonary congestion (PC) events. Changes in intrathoracic impedance between the right ventricular (RV) coil and device can (RVcoil→Can) of implantable cardioverter-defibrillators (ICDs) and cardiac resynchronization therapy ICDs (CRT-Ds) are used clinically for the detection of PC events, but other impedance vectors and algorithms have not been studied prospectively. An initial 75-patient study was used to derive optimal impedance vectors to detect PC events, with 2 vector combinations selected for prospective analysis in DEFEAT-PE (ICD vectors: RVring→Can + RVcoil→Can, detection threshold 13 days; CRT-D vectors: left ventricular ring→Can + RVcoil→Can, detection threshold 14 days). Impedance changes were considered true positive if detected <30 days before an adjudicated PC event. One hundred sixty-two patients were enrolled (80 with ICDs and 82 with CRT-Ds), all with ≥1 previous PC event. One hundred forty-four patients provided study data, with 214 patient-years of follow-up and 139 PC events. Sensitivity for PC events of the prespecified algorithms was as follows: ICD: sensitivity 32.3%, false-positive rate 1.28 per patient-year; CRT-D: sensitivity 32.4%, false-positive rate 1.66 per patient-year. An alternative algorithm, ultimately approved by the US Food and Drug Administration (RVring→Can + RVcoil→Can, detection threshold 14 days), resulted in (for all patients) sensitivity of 21.6% and a false-positive rate of 0.9 per patient-year. The CRT-D thoracic impedance vector algorithm selected in the derivation study was not superior to the ICD algorithm RVring→Can + RVcoil→Can when studied prospectively. In conclusion, to achieve an acceptably low false-positive rate, the intrathoracic impedance algorithms studied in DEFEAT-PE resulted in low sensitivity for the prediction of heart failure events.
Detect Fluid Early from Intrathoracic Impedance Monitoring (DEFEAT-PE) is a prospective, multicenter study of multiple intrathoracic impedance vectors to detect pulmonary congestion (PC) events. Changes in intrathoracic impedance between the right ventricular (RV) coil and device can (RVcoil->Can) of implantable cardioverter-defibrillators (ICDs) and cardiac resynchronization therapy ICDs (CRT-Ds) are used clinically for the detection of PC events, but other impedance vectors and algorithms have not been studied prospectively. An initial 75-patient study was used to derive optimal impedance vectors to detect PC events, with 2 vector combinations selected for prospective analysis in DEFEAT-PE (ICD vectors: RVring->Can + RVcoil->Can, detection threshold 13 days; CRT-D vectors: left ventricular ring->Can + RVcoil->Can, detection threshold 14 days). Impedance changes were considered true positive if detected <30 days before an adjudicated PC event. One hundred sixty-two patients were enrolled (80 with ICDs and 82 with CRT-Ds), all with >=1 previous PC event. One hundred forty-four patients provided study data, with 214 patient-years of follow-up and 139 PC events. Sensitivity for PC events of the prespecified algorithms was as follows: ICD: sensitivity 32.3%, false-positive rate 1.28 per patient-year; CRT-D: sensitivity 32.4%, false-positive rate 1.66 per patient-year. An alternative algorithm, ultimately approved by the US Food and Drug Administration (RVring->Can + RVcoil->Can, detection threshold 14 days), resulted in (for all patients) sensitivity of 21.6% and a false-positive rate of 0.9 per patient-year. The CRT-D thoracic impedance vector algorithm selected in the derivation study was not superior to the ICD algorithm RVring->Can + RVcoil->Can when studied prospectively. In conclusion, to achieve an acceptably low false-positive rate, the intrathoracic impedance algorithms studied in DEFEAT-PE resulted in low sensitivity for the prediction of heart failure events.
Author Heist, E. Kevin
Herre, John M.
Porterfield, Linda M.
Turkel, Melanie
Binkley, Philip F.
Van Bakel, Adrian B.
Qu, Fujian
Pavri, Behzad B.
Porterfield, James G.
Author_xml – sequence: 1
  givenname: E. Kevin
  surname: Heist
  fullname: Heist, E. Kevin
  email: kheist@partners.org
  organization: Cardiac Arrhythmia Service, Massachusetts General Hospital, Boston, Massachusetts
– sequence: 2
  givenname: John M.
  surname: Herre
  fullname: Herre, John M.
  organization: Eastern Virginia Medical and Sentara Norfolk General Hospital, Norfolk, Virginia
– sequence: 3
  givenname: Philip F.
  surname: Binkley
  fullname: Binkley, Philip F.
  organization: Division of Cardiovascular Medicine and Davis Heart and Lung Institute, The Ohio State University, Columbus, Ohio
– sequence: 4
  givenname: Adrian B.
  surname: Van Bakel
  fullname: Van Bakel, Adrian B.
  organization: Medical University of South Carolina, Charleston, South Carolina
– sequence: 5
  givenname: James G.
  surname: Porterfield
  fullname: Porterfield, James G.
  organization: Methodist University Hospital, Memphis, Tennessee
– sequence: 6
  givenname: Linda M.
  surname: Porterfield
  fullname: Porterfield, Linda M.
  organization: Methodist University Hospital, Memphis, Tennessee
– sequence: 7
  givenname: Fujian
  surname: Qu
  fullname: Qu, Fujian
  organization: St. Jude Medical, Sylmar, California
– sequence: 8
  givenname: Melanie
  surname: Turkel
  fullname: Turkel, Melanie
  organization: St. Jude Medical, Sylmar, California
– sequence: 9
  givenname: Behzad B.
  surname: Pavri
  fullname: Pavri, Behzad B.
  organization: Thomas Jefferson University School of Medicine, Philadelphia, Pennsylvania
BackLink https://www.ncbi.nlm.nih.gov/pubmed/25150135$$D View this record in MEDLINE/PubMed
BookMark eNqNkl9v0zAUxSM0xLrBRwBZ4mU8pPgmceIIDbQ_Las0xMOAV8uzr5lLEhc7qdTvtQ-IQwtIlabxZF35d46tc-5RctC5DpPkJdApUCjfLqeyXSrp9TSjUExpNaUFf5JMgFd1CjXkB8mEUpqlNRT1YXIUwjKOAKx8lhxmDBiFnE2S-7NONptgA3GGXFpj0GPXk0tcW4XpuQyoyaLrvezvnJfKKrJoV6hlp5B8Q9U7H4hxPgr6OFnXjT5XKH1P5tI2g0cyW0fHQE6Mdy3p73DHknkzWE1m0jcb8vvuoXc-uc7Gh2z3ndz0g968eZ48NbIJ-GJ3Hidf57MvF1fp9eePi4uz61SxKutTAMp5KU1Rc2mUrlRBNSDjqFBzw1lR1pnKaq7zHHMO3NS8rLLbjDJZy0zS_Dg52fquvPs5YOhFa4PCppEduiGIGGYJEHPkEX29hy7d4GO2kSqhgAxyziL1akcNty1qsfK2lX4j_vQRAbYFlHcheDR_EaBi7F0sxa53MfYuaCVi71H3bk-nbC_HPmKktnlU_WGrxhjm2qIXQVmM0WvrY1NCO_uow_s9B9XYzirZ_MANhn9ZiJAJKm7GzRwXEwoKLC_yaHD6sMF_fOAXHpT23w
CODEN AJCDAG
CitedBy_id crossref_primary_10_1161_CIRCHEARTFAILURE_119_006513
crossref_primary_10_1016_j_rec_2021_09_015
crossref_primary_10_1093_europace_euv293
crossref_primary_10_1002_ejhf_321
crossref_primary_10_1016_j_hrthm_2020_10_008
crossref_primary_10_1016_j_jchf_2016_12_011
crossref_primary_10_1007_s10840_019_00607_x
crossref_primary_10_3390_s21113763
crossref_primary_10_2196_jmir_8066
crossref_primary_10_1080_17434440_2017_1306438
crossref_primary_10_1007_s11886_020_01309_x
crossref_primary_10_1016_j_tcm_2017_08_003
crossref_primary_10_1080_17434440_2024_2347412
crossref_primary_10_1002_ehf2_12171
crossref_primary_10_1016_j_ijcard_2016_06_323
crossref_primary_10_1111_pace_13399
crossref_primary_10_3390_diagnostics14222554
crossref_primary_10_3390_jcm12062373
crossref_primary_10_1016_j_ijcard_2017_02_120
crossref_primary_10_3390_jcdd10040152
crossref_primary_10_1007_s00380_017_0953_z
crossref_primary_10_1016_j_cardfail_2021_11_008
crossref_primary_10_2196_medinform_4842
crossref_primary_10_1016_j_cardfail_2021_11_006
crossref_primary_10_1016_j_hrthm_2022_11_026
crossref_primary_10_15420_aer_2022_13
crossref_primary_10_1016_j_cardfail_2022_03_349
crossref_primary_10_1111_anec_70015
crossref_primary_10_1007_s11886_015_0641_5
crossref_primary_10_1016_j_mcna_2015_02_013
crossref_primary_10_1111_hdi_13033
crossref_primary_10_1016_j_hfc_2020_06_002
crossref_primary_10_1136_heartjnl_2020_318062
crossref_primary_10_1016_j_jelectrocard_2019_01_004
crossref_primary_10_1038_s41598_020_60358_y
crossref_primary_10_1088_1361_6579_38_1_15
Cites_doi 10.1042/CS20100388
10.1016/j.cardfail.2009.01.012
10.1016/j.jacc.2009.11.089
10.1111/j.1751-7133.2011.00248.x
10.1161/CIRCULATIONAHA.104.492207
10.1111/j.1751-7133.2010.00149.x
10.1016/j.jacc.2005.12.071
10.1093/europace/eup419
10.1161/CIRCHEARTFAILURE.109.867549
10.1093/eurheartj/ehs121
10.1016/j.cardfail.2011.10.017
10.1016/j.ejheart.2007.03.005
10.1093/eurheartj/ehr050
10.1016/j.jacc.2008.12.018
10.1007/s10840-012-9693-2
10.1056/NEJMoa1010029
10.1093/eurheartj/ehs444
10.1016/j.ahj.2008.10.016
10.1097/HCO.0b013e3283502137
ContentType Journal Article
Copyright 2014 Elsevier Inc.
Elsevier Inc.
Copyright © 2014 Elsevier Inc. All rights reserved.
Copyright Elsevier Limited Oct 15, 2014
Copyright_xml – notice: 2014 Elsevier Inc.
– notice: Elsevier Inc.
– notice: Copyright © 2014 Elsevier Inc. All rights reserved.
– notice: Copyright Elsevier Limited Oct 15, 2014
CorporateAuthor DEFEAT-PE Study Investigators
CorporateAuthor_xml – name: DEFEAT-PE Study Investigators
DBID AAYXX
CITATION
CGR
CUY
CVF
ECM
EIF
NPM
3V.
7RV
7TS
7X7
7XB
88E
8FD
8FI
8FJ
8FK
8G5
ABUWG
AFKRA
AZQEC
BENPR
CCPQU
DWQXO
FR3
FYUFA
GHDGH
GNUQQ
GUQSH
K9.
KB0
M0S
M1P
M2O
M7Z
MBDVC
NAPCQ
P64
PHGZM
PHGZT
PJZUB
PKEHL
PPXIY
PQEST
PQQKQ
PQUKI
Q9U
7X8
DOI 10.1016/j.amjcard.2014.07.048
DatabaseName CrossRef
Medline
MEDLINE
MEDLINE (Ovid)
MEDLINE
MEDLINE
PubMed
ProQuest Central (Corporate)
Nursing & Allied Health Database
Physical Education Index
Health & Medical Collection (ProQuest)
ProQuest Central (purchase pre-March 2016)
Medical Database (Alumni Edition)
Technology Research Database
ProQuest Hospital Collection
Hospital Premium Collection (Alumni Edition)
ProQuest Central (Alumni) (purchase pre-March 2016)
Research Library (Alumni)
ProQuest Central (Alumni)
ProQuest Central UK/Ireland
ProQuest Central Essentials
ProQuest Central Database Suite (ProQuest)
ProQuest One
ProQuest Central Korea
Engineering Research Database
Health Research Premium Collection
Health Research Premium Collection (Alumni)
ProQuest Central Student
ProQuest Research Library
ProQuest Health & Medical Complete (Alumni)
Nursing & Allied Health Database (Alumni Edition)
ProQuest Health & Medical Collection
Medical Database
Research Library
Biochemistry Abstracts 1
Research Library (Corporate)
Nursing & Allied Health Premium
Biotechnology and BioEngineering Abstracts
ProQuest Central Premium
ProQuest One Academic (New)
ProQuest Health & Medical Research Collection
ProQuest One Academic Middle East (New)
ProQuest One Health & Nursing
ProQuest One Academic Eastern Edition (DO NOT USE)
ProQuest One Academic (retired)
ProQuest One Academic UKI Edition
ProQuest Central Basic
MEDLINE - Academic
DatabaseTitle CrossRef
MEDLINE
Medline Complete
MEDLINE with Full Text
PubMed
MEDLINE (Ovid)
Research Library Prep
ProQuest Central Student
Technology Research Database
ProQuest One Academic Middle East (New)
ProQuest Central Essentials
ProQuest Health & Medical Complete (Alumni)
ProQuest Central (Alumni Edition)
ProQuest One Community College
ProQuest One Health & Nursing
Research Library (Alumni Edition)
Physical Education Index
ProQuest Central
ProQuest Health & Medical Research Collection
Health Research Premium Collection
Health and Medicine Complete (Alumni Edition)
ProQuest Central Korea
Health & Medical Research Collection
ProQuest Research Library
ProQuest Central (New)
ProQuest Medical Library (Alumni)
ProQuest Central Basic
ProQuest One Academic Eastern Edition
ProQuest Nursing & Allied Health Source
ProQuest Hospital Collection
Health Research Premium Collection (Alumni)
ProQuest Hospital Collection (Alumni)
Biotechnology and BioEngineering Abstracts
Nursing & Allied Health Premium
ProQuest Health & Medical Complete
ProQuest Medical Library
ProQuest One Academic UKI Edition
Biochemistry Abstracts 1
ProQuest Nursing & Allied Health Source (Alumni)
Engineering Research Database
ProQuest One Academic
ProQuest One Academic (New)
ProQuest Central (Alumni)
MEDLINE - Academic
DatabaseTitleList

MEDLINE - Academic

MEDLINE
Research Library Prep
Database_xml – sequence: 1
  dbid: NPM
  name: PubMed
  url: http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed
  sourceTypes: Index Database
– sequence: 2
  dbid: 7RV
  name: Nursing & Allied Health Database
  url: https://search.proquest.com/nahs
  sourceTypes: Aggregation Database
DeliveryMethod fulltext_linktorsrc
Discipline Medicine
EISSN 1879-1913
EndPage 1256
ExternalDocumentID 3465770581
25150135
10_1016_j_amjcard_2014_07_048
S0002914914015343
1_s2_0_S0002914914015343
Genre Clinical Trial
Multicenter Study
Journal Article
GeographicLocations United States
GeographicLocations_xml – name: United States
GroupedDBID ---
--K
--M
.1-
.FO
.~1
0R~
123
1B1
1P~
1RT
1~.
1~5
23M
4.4
457
4G.
53G
5RE
5VS
6J9
7-5
71M
7RV
7X7
88E
8FI
8FJ
8G5
8P~
9JM
AABNK
AAEDT
AAEDW
AAIKJ
AAKOC
AALRI
AAQFI
AAQQT
AATTM
AAWTL
AAXKI
AAXUO
ABBQC
ABFNM
ABJNI
ABLJU
ABMAC
ABMZM
ABOCM
ABPPZ
ABUWG
ABXDB
ACDAQ
ACGFO
ACGFS
ACIEU
ACIUM
ACIWK
ACLOT
ACPRK
ACRLP
ACVFH
ADBBV
ADCNI
ADEZE
ADFRT
ADUKH
AEBSH
AEIPS
AEKER
AENEX
AEUPX
AEVXI
AFKRA
AFPUW
AFRAH
AFRHN
AFTJW
AFXIZ
AGHFR
AGUBO
AGYEJ
AHHHB
AHMBA
AIEXJ
AIIUN
AIKHN
AITUG
AJRQY
AJUYK
AKBMS
AKRWK
AKYEP
ALMA_UNASSIGNED_HOLDINGS
AMRAJ
ANKPU
ANZVX
AXJTR
AZQEC
BENPR
BKEYQ
BKOJK
BKOMP
BLXMC
BNPGV
BPHCQ
BVXVI
CCPQU
CS3
DWQXO
EBS
EFJIC
EFKBS
EFLBG
EJD
EMOBN
EO9
EP2
EP3
EX3
F5P
FDB
FIRID
FNPLU
FYGXN
FYUFA
G-Q
GBLVA
GNUQQ
GUQSH
HMCUK
IH2
IHE
J1W
J5H
K-O
KOM
L7B
M1P
M29
M2O
M41
MO0
N9A
NAPCQ
O-L
O9-
OA.
OAUVE
OL~
OZT
P-8
P-9
P2P
PC.
PHGZM
PHGZT
PJZUB
PPXIY
PQQKQ
PROAC
PSQYO
Q38
ROL
RPZ
SDF
SDG
SEL
SES
SJN
SPCBC
SSH
SSZ
SV3
T5K
TWZ
UKHRP
UNMZH
UV1
WH7
WOW
YFH
YOC
YZZ
Z5R
~G-
~HD
.55
.GJ
1CY
3O-
3V.
AACTN
AAQXK
AAYOK
ABWVN
ACRPL
ADMUD
ADNMO
AFCTW
AFFNX
AFJKZ
AFKWA
AJOXV
ALIPV
AMFUW
ASPBG
AVWKF
AZFZN
FEDTE
FGOYB
G-2
HEB
HMK
HMO
HVGLF
HZ~
OHT
OVD
PKN
R2-
RIG
SAE
TEORI
WUQ
X7M
XPP
YQJ
YYP
ZGI
ZXP
AAIAV
ABLVK
ABYKQ
AJBFU
LCYCR
ZA5
9DU
AAYWO
AAYXX
AFFHD
AGQPQ
AIGII
APXCP
CITATION
AGCQF
AGRNS
CGR
CUY
CVF
ECM
EIF
NPM
7TS
7XB
8FD
8FK
FR3
K9.
M7Z
MBDVC
P64
PKEHL
PQEST
PQUKI
Q9U
7X8
ID FETCH-LOGICAL-c572t-110886af498afcd7c40d1e58eced8f854692c298d33e3818f98672b205a9a2a03
IEDL.DBID 7X7
ISICitedReferencesCount 49
ISICitedReferencesURI http://www.webofscience.com/api/gateway?GWVersion=2&SrcApp=Summon&SrcAuth=ProQuest&DestLinkType=CitingArticles&DestApp=WOS_CPL&KeyUT=000343021300021&url=https%3A%2F%2Fcvtisr.summon.serialssolutions.com%2F%23%21%2Fsearch%3Fho%3Df%26include.ft.matches%3Dt%26l%3Dnull%26q%3D
ISSN 0002-9149
1879-1913
IngestDate Sun Nov 09 05:01:52 EST 2025
Tue Oct 07 05:30:45 EDT 2025
Mon Jul 21 06:00:39 EDT 2025
Tue Nov 18 21:45:41 EST 2025
Sat Nov 29 06:58:41 EST 2025
Fri Feb 23 02:27:32 EST 2024
Sun Feb 23 10:20:35 EST 2025
Tue Oct 14 19:30:32 EDT 2025
IsPeerReviewed true
IsScholarly true
Issue 8
Language English
License Copyright © 2014 Elsevier Inc. All rights reserved.
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-c572t-110886af498afcd7c40d1e58eced8f854692c298d33e3818f98672b205a9a2a03
Notes ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
ObjectType-Article-2
ObjectType-Feature-1
content type line 23
PMID 25150135
PQID 1614121385
PQPubID 41200
PageCount 8
ParticipantIDs proquest_miscellaneous_1566111358
proquest_journals_1614121385
pubmed_primary_25150135
crossref_primary_10_1016_j_amjcard_2014_07_048
crossref_citationtrail_10_1016_j_amjcard_2014_07_048
elsevier_sciencedirect_doi_10_1016_j_amjcard_2014_07_048
elsevier_clinicalkeyesjournals_1_s2_0_S0002914914015343
elsevier_clinicalkey_doi_10_1016_j_amjcard_2014_07_048
PublicationCentury 2000
PublicationDate 2014-10-15
PublicationDateYYYYMMDD 2014-10-15
PublicationDate_xml – month: 10
  year: 2014
  text: 2014-10-15
  day: 15
PublicationDecade 2010
PublicationPlace United States
PublicationPlace_xml – name: United States
– name: New York
PublicationTitle The American journal of cardiology
PublicationTitleAlternate Am J Cardiol
PublicationYear 2014
Publisher Elsevier Inc
Elsevier Limited
Publisher_xml – name: Elsevier Inc
– name: Elsevier Limited
References Whellan, Droogan, Fitzpatrick, Adams, McCarey, Andrel, Mather, Rubin, Bonita, Keith (bib13) 2012; 18
Maines, Catanzariti, Cirrincione, Valsecchi, Comisso, Vergara (bib18) 2010; 12
Tang, Tong (bib3) 2009; 157
Conraads, Tavazzi, Santini, Oliva, Gerritse, Yu, Cowie (bib20) 2011; 32
Tang, Warman, Johnson, Small, Heywood (bib12) 2012; 33
Yu, Wang, Chau, Chan, Kong, Tang, Christensen, Stadler, Lau (bib2) 2005; 112
Epstein, DiMarco, Ellenbogen, Estes, Freedman, Gettes, Gillinov, Gregoratos, Hammill, Hayes, Hlatky, Newby, Page, Schoenfeld, Silka, Stevenson, Sweeney, Smith, Jacobs, Adams, Anderson, Buller, Creager, Ettinger, Faxon, Halperin, Hiratzka, Hunt, Krumholz, Kushner, Lytle, Nishimura, Ornato, Riegel, Tarkington, Yancy (bib6) 2008; 117
Chaudhry, Mattera, Curtis, Spertus, Herrin, Lin, Phillips, Hodshon, Cooper, Krumholz (bib7) 2010; 363
Ambrosy, Pang, Khan, Konstam, Fonarow, Traver, Maggioni, Cook, Swedberg, Burnett, Grinfeld, Udelson, Zannad, Gheorghiade (bib1) 2013; 34
Rademaker, Charles, Melton, Richards, Frampton, Siou, Qu, Eigler, Gutfinger, Troughton (bib16) 2011; 120
Vanderheyden, Houben, Verstreken, Stahlberg, Reiters, Kessels, Braunschweig (bib17) 2010; 3
Mullens, Oliveira, Verga, Wilkoff, Tang (bib19) 2010; 16
Whellan, Ousdigian, Al-Khatib, Pu, Sarkar, Porter, Pavri, O'Connor (bib9) 2010; 55
Khoury, Naware, Siou, Blomqvist, Mathuria, Wang, Shih, Nagueh, Panescu (bib4) 2009; 53
Binkley, Porterfield, Porterfield, Beau, Corbisiero, Greer, Love, Turkel, Bjorling, Qu, Farazi (bib5) 2012; 35
Packer, Abraham, Mehra, Yancy, Lawless, Mitchell, Smart, Bijou, O'Connor, Massie, Pina, Greenberg, Young, Fishbein, Hauptman, Bourge, Strobeck, Murali, Schocken, Teerlink, Levy, Trupp, Silver (bib11) 2006; 47
Small, Wickemeyer, Germany, Hoppe, Andrulli, Brady, Labeau, Koehler, Sarkar, Hettrick, Tang (bib14) 2009; 15
Luthje, Vollmann, Drescher, Schott, Zenker, Hasenfuss, Unterberg (bib15) 2007; 9
Malfatto, Blengino, Perego, Branzi, Villani, Facchini, Parati (bib10) 2012; 18
Clarke, Howlett (bib8) 2012; 27
Small (10.1016/j.amjcard.2014.07.048_bib14) 2009; 15
Whellan (10.1016/j.amjcard.2014.07.048_bib13) 2012; 18
Luthje (10.1016/j.amjcard.2014.07.048_bib15) 2007; 9
Khoury (10.1016/j.amjcard.2014.07.048_bib4) 2009; 53
Mullens (10.1016/j.amjcard.2014.07.048_bib19) 2010; 16
Tang (10.1016/j.amjcard.2014.07.048_bib12) 2012; 33
Binkley (10.1016/j.amjcard.2014.07.048_bib5) 2012; 35
Chaudhry (10.1016/j.amjcard.2014.07.048_bib7) 2010; 363
Vanderheyden (10.1016/j.amjcard.2014.07.048_bib17) 2010; 3
Tang (10.1016/j.amjcard.2014.07.048_bib3) 2009; 157
Epstein (10.1016/j.amjcard.2014.07.048_bib6) 2008; 117
Rademaker (10.1016/j.amjcard.2014.07.048_bib16) 2011; 120
Packer (10.1016/j.amjcard.2014.07.048_bib11) 2006; 47
Clarke (10.1016/j.amjcard.2014.07.048_bib8) 2012; 27
Ambrosy (10.1016/j.amjcard.2014.07.048_bib1) 2013; 34
Conraads (10.1016/j.amjcard.2014.07.048_bib20) 2011; 32
Maines (10.1016/j.amjcard.2014.07.048_bib18) 2010; 12
Malfatto (10.1016/j.amjcard.2014.07.048_bib10) 2012; 18
Whellan (10.1016/j.amjcard.2014.07.048_bib9) 2010; 55
Yu (10.1016/j.amjcard.2014.07.048_bib2) 2005; 112
References_xml – volume: 47
  start-page: 2245
  year: 2006
  end-page: 2252
  ident: bib11
  article-title: Utility of impedance cardiography for the identification of short-term risk of clinical decompensation in stable patients with chronic heart failure
  publication-title: J Am Coll Cardiol
– volume: 55
  start-page: 1803
  year: 2010
  end-page: 1810
  ident: bib9
  article-title: Combined heart failure device diagnostics identify patients at higher risk of subsequent heart failure hospitalizations: results from PARTNERS HF (Program to Access and Review Trending Information and Evaluate Correlation to Symptoms in Patients With Heart Failure) study
  publication-title: J Am Coll Cardiol
– volume: 15
  start-page: 475
  year: 2009
  end-page: 481
  ident: bib14
  article-title: Changes in intrathoracic impedance are associated with subsequent risk of hospitalizations for acute decompensated heart failure: clinical utility of implanted device monitoring without a patient alert
  publication-title: J Card Fail
– volume: 117
  start-page: e350
  year: 2008
  end-page: e408
  ident: bib6
  article-title: ACC/AHA/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the ACC/AHA/NASPE 2002 Guideline Update for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices): developed in collaboration with the American Association for Thoracic Surgery and Society of Thoracic Surgeons
  publication-title: Circulation
– volume: 27
  start-page: 130
  year: 2012
  end-page: 136
  ident: bib8
  article-title: Integration of monitoring technology for heart failure
  publication-title: Curr Opin Cardiol
– volume: 9
  start-page: 716
  year: 2007
  end-page: 722
  ident: bib15
  article-title: Intrathoracic impedance monitoring to detect chronic heart failure deterioration: relationship to changes in NT-proBNP
  publication-title: Eur J Heart Fail
– volume: 3
  start-page: 370
  year: 2010
  end-page: 377
  ident: bib17
  article-title: Continuous monitoring of intrathoracic impedance and right ventricular pressures in patients with heart failure
  publication-title: Circ Heart Fail
– volume: 363
  start-page: 2301
  year: 2010
  end-page: 2309
  ident: bib7
  article-title: Telemonitoring in patients with heart failure
  publication-title: N Engl J Med
– volume: 34
  start-page: 835
  year: 2013
  end-page: 843
  ident: bib1
  article-title: Clinical course and predictive value of congestion during hospitalization in patients admitted for worsening signs and symptoms of heart failure with reduced ejection fraction: findings from the EVEREST trial
  publication-title: Eur Heart J
– volume: 53
  start-page: 1075
  year: 2009
  end-page: 1081
  ident: bib4
  article-title: Ambulatory monitoring of congestive heart failure by multiple bioelectric impedance vectors
  publication-title: J Am Coll Cardiol
– volume: 18
  start-page: 107
  year: 2012
  end-page: 112
  ident: bib13
  article-title: Change in intrathoracic impedance measures during acute decompensated heart failure admission: results from the Diagnostic Data for Discharge in Heart Failure Patients (3D-HF) pilot study
  publication-title: J Card Fail
– volume: 157
  start-page: 402
  year: 2009
  end-page: 411
  ident: bib3
  article-title: Measuring impedance in congestive heart failure: Current options and clinical applications
  publication-title: Am Heart J
– volume: 33
  start-page: 2189
  year: 2012
  end-page: 2196
  ident: bib12
  article-title: Threshold crossing of device-based intrathoracic impedance trends identifies relatively increased mortality risk
  publication-title: Eur Heart J
– volume: 35
  start-page: 197
  year: 2012
  end-page: 206
  ident: bib5
  article-title: Feasibility of using multivector impedance to monitor pulmonary congestion in heart failure patients
  publication-title: J Interv Card Electrophysiol
– volume: 120
  start-page: 207
  year: 2011
  end-page: 217
  ident: bib16
  article-title: Monitoring of heart failure: comparison of left atrial pressure with intrathoracic impedance and natriuretic peptide measurements in an experimental model of ovine heart failure
  publication-title: Clin Sci (Lond)
– volume: 16
  start-page: 159
  year: 2010
  end-page: 163
  ident: bib19
  article-title: Insights from internet-based remote intrathoracic impedance monitoring as part of a heart failure disease management program
  publication-title: Congest Heart Fail
– volume: 112
  start-page: 841
  year: 2005
  end-page: 848
  ident: bib2
  article-title: Intrathoracic impedance monitoring in patients with heart failure: correlation with fluid status and feasibility of early warning preceding hospitalization
  publication-title: Circulation
– volume: 18
  start-page: 25
  year: 2012
  end-page: 31
  ident: bib10
  article-title: Transthoracic impedance accurately estimates pulmonary wedge pressure in patients with decompensated chronic heart failure
  publication-title: Congest Heart Fail
– volume: 12
  start-page: 680
  year: 2010
  end-page: 685
  ident: bib18
  article-title: Intrathoracic impedance and pulmonary wedge pressure for the detection of heart failure deterioration
  publication-title: Europace
– volume: 32
  start-page: 2266
  year: 2011
  end-page: 2273
  ident: bib20
  article-title: Sensitivity and positive predictive value of implantable intrathoracic impedance monitoring as a predictor of heart failure hospitalizations: the SENSE-HF trial
  publication-title: Eur Heart J
– volume: 120
  start-page: 207
  year: 2011
  ident: 10.1016/j.amjcard.2014.07.048_bib16
  article-title: Monitoring of heart failure: comparison of left atrial pressure with intrathoracic impedance and natriuretic peptide measurements in an experimental model of ovine heart failure
  publication-title: Clin Sci (Lond)
  doi: 10.1042/CS20100388
– volume: 15
  start-page: 475
  year: 2009
  ident: 10.1016/j.amjcard.2014.07.048_bib14
  article-title: Changes in intrathoracic impedance are associated with subsequent risk of hospitalizations for acute decompensated heart failure: clinical utility of implanted device monitoring without a patient alert
  publication-title: J Card Fail
  doi: 10.1016/j.cardfail.2009.01.012
– volume: 55
  start-page: 1803
  year: 2010
  ident: 10.1016/j.amjcard.2014.07.048_bib9
  publication-title: J Am Coll Cardiol
  doi: 10.1016/j.jacc.2009.11.089
– volume: 117
  start-page: e350
  year: 2008
  ident: 10.1016/j.amjcard.2014.07.048_bib6
  publication-title: Circulation
– volume: 18
  start-page: 25
  year: 2012
  ident: 10.1016/j.amjcard.2014.07.048_bib10
  article-title: Transthoracic impedance accurately estimates pulmonary wedge pressure in patients with decompensated chronic heart failure
  publication-title: Congest Heart Fail
  doi: 10.1111/j.1751-7133.2011.00248.x
– volume: 112
  start-page: 841
  year: 2005
  ident: 10.1016/j.amjcard.2014.07.048_bib2
  article-title: Intrathoracic impedance monitoring in patients with heart failure: correlation with fluid status and feasibility of early warning preceding hospitalization
  publication-title: Circulation
  doi: 10.1161/CIRCULATIONAHA.104.492207
– volume: 16
  start-page: 159
  year: 2010
  ident: 10.1016/j.amjcard.2014.07.048_bib19
  article-title: Insights from internet-based remote intrathoracic impedance monitoring as part of a heart failure disease management program
  publication-title: Congest Heart Fail
  doi: 10.1111/j.1751-7133.2010.00149.x
– volume: 47
  start-page: 2245
  year: 2006
  ident: 10.1016/j.amjcard.2014.07.048_bib11
  article-title: Utility of impedance cardiography for the identification of short-term risk of clinical decompensation in stable patients with chronic heart failure
  publication-title: J Am Coll Cardiol
  doi: 10.1016/j.jacc.2005.12.071
– volume: 12
  start-page: 680
  year: 2010
  ident: 10.1016/j.amjcard.2014.07.048_bib18
  article-title: Intrathoracic impedance and pulmonary wedge pressure for the detection of heart failure deterioration
  publication-title: Europace
  doi: 10.1093/europace/eup419
– volume: 3
  start-page: 370
  year: 2010
  ident: 10.1016/j.amjcard.2014.07.048_bib17
  article-title: Continuous monitoring of intrathoracic impedance and right ventricular pressures in patients with heart failure
  publication-title: Circ Heart Fail
  doi: 10.1161/CIRCHEARTFAILURE.109.867549
– volume: 33
  start-page: 2189
  year: 2012
  ident: 10.1016/j.amjcard.2014.07.048_bib12
  article-title: Threshold crossing of device-based intrathoracic impedance trends identifies relatively increased mortality risk
  publication-title: Eur Heart J
  doi: 10.1093/eurheartj/ehs121
– volume: 18
  start-page: 107
  year: 2012
  ident: 10.1016/j.amjcard.2014.07.048_bib13
  article-title: Change in intrathoracic impedance measures during acute decompensated heart failure admission: results from the Diagnostic Data for Discharge in Heart Failure Patients (3D-HF) pilot study
  publication-title: J Card Fail
  doi: 10.1016/j.cardfail.2011.10.017
– volume: 9
  start-page: 716
  year: 2007
  ident: 10.1016/j.amjcard.2014.07.048_bib15
  article-title: Intrathoracic impedance monitoring to detect chronic heart failure deterioration: relationship to changes in NT-proBNP
  publication-title: Eur J Heart Fail
  doi: 10.1016/j.ejheart.2007.03.005
– volume: 32
  start-page: 2266
  year: 2011
  ident: 10.1016/j.amjcard.2014.07.048_bib20
  article-title: Sensitivity and positive predictive value of implantable intrathoracic impedance monitoring as a predictor of heart failure hospitalizations: the SENSE-HF trial
  publication-title: Eur Heart J
  doi: 10.1093/eurheartj/ehr050
– volume: 53
  start-page: 1075
  year: 2009
  ident: 10.1016/j.amjcard.2014.07.048_bib4
  article-title: Ambulatory monitoring of congestive heart failure by multiple bioelectric impedance vectors
  publication-title: J Am Coll Cardiol
  doi: 10.1016/j.jacc.2008.12.018
– volume: 35
  start-page: 197
  year: 2012
  ident: 10.1016/j.amjcard.2014.07.048_bib5
  article-title: Feasibility of using multivector impedance to monitor pulmonary congestion in heart failure patients
  publication-title: J Interv Card Electrophysiol
  doi: 10.1007/s10840-012-9693-2
– volume: 363
  start-page: 2301
  year: 2010
  ident: 10.1016/j.amjcard.2014.07.048_bib7
  article-title: Telemonitoring in patients with heart failure
  publication-title: N Engl J Med
  doi: 10.1056/NEJMoa1010029
– volume: 34
  start-page: 835
  year: 2013
  ident: 10.1016/j.amjcard.2014.07.048_bib1
  article-title: Clinical course and predictive value of congestion during hospitalization in patients admitted for worsening signs and symptoms of heart failure with reduced ejection fraction: findings from the EVEREST trial
  publication-title: Eur Heart J
  doi: 10.1093/eurheartj/ehs444
– volume: 157
  start-page: 402
  year: 2009
  ident: 10.1016/j.amjcard.2014.07.048_bib3
  article-title: Measuring impedance in congestive heart failure: Current options and clinical applications
  publication-title: Am Heart J
  doi: 10.1016/j.ahj.2008.10.016
– volume: 27
  start-page: 130
  year: 2012
  ident: 10.1016/j.amjcard.2014.07.048_bib8
  article-title: Integration of monitoring technology for heart failure
  publication-title: Curr Opin Cardiol
  doi: 10.1097/HCO.0b013e3283502137
SSID ssj0001156
Score 2.3560708
Snippet Detect Fluid Early from Intrathoracic Impedance Monitoring (DEFEAT-PE) is a prospective, multicenter study of multiple intrathoracic impedance vectors to...
SourceID proquest
pubmed
crossref
elsevier
SourceType Aggregation Database
Index Database
Enrichment Source
Publisher
StartPage 1249
SubjectTerms Aged
Algorithms
Angina pectoris
Cardiac Resynchronization Therapy
Cardiography, Impedance - instrumentation
Cardiovascular
Chronic obstructive pulmonary disease
Drug therapy
Electric Impedance
Equipment Design
Feasibility Studies
Female
Follow-Up Studies
Heart attacks
Heart Failure - complications
Heart Failure - diagnosis
Heart Failure - therapy
Heart Ventricles - physiopathology
Humans
Incidence
Male
Middle Aged
Prospective Studies
Pulmonary Edema - diagnosis
Pulmonary Edema - epidemiology
Pulmonary Edema - etiology
Reproducibility of Results
Respiratory distress syndrome
United States - epidemiology
Title Analysis of Different Device-Based Intrathoracic Impedance Vectors for Detection of Heart Failure Events (from the Detect Fluid Early from Intrathoracic Impedance Monitoring Study)
URI https://www.clinicalkey.com/#!/content/1-s2.0-S0002914914015343
https://www.clinicalkey.es/playcontent/1-s2.0-S0002914914015343
https://dx.doi.org/10.1016/j.amjcard.2014.07.048
https://www.ncbi.nlm.nih.gov/pubmed/25150135
https://www.proquest.com/docview/1614121385
https://www.proquest.com/docview/1566111358
Volume 114
WOSCitedRecordID wos000343021300021&url=https%3A%2F%2Fcvtisr.summon.serialssolutions.com%2F%23%21%2Fsearch%3Fho%3Df%26include.ft.matches%3Dt%26l%3Dnull%26q%3D
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
journalDatabaseRights – providerCode: PRVESC
  databaseName: Elsevier SD Freedom Collection Journals 2021
  customDbUrl:
  eissn: 1879-1913
  dateEnd: 99991231
  omitProxy: false
  ssIdentifier: ssj0001156
  issn: 0002-9149
  databaseCode: AIEXJ
  dateStart: 19950101
  isFulltext: true
  titleUrlDefault: https://www.sciencedirect.com
  providerName: Elsevier
– providerCode: PRVPQU
  databaseName: Health & Medical Collection
  customDbUrl:
  eissn: 1879-1913
  dateEnd: 20251014
  omitProxy: false
  ssIdentifier: ssj0001156
  issn: 0002-9149
  databaseCode: 7X7
  dateStart: 20120815
  isFulltext: true
  titleUrlDefault: https://search.proquest.com/healthcomplete
  providerName: ProQuest
– providerCode: PRVPQU
  databaseName: Nursing & Allied Health Database
  customDbUrl:
  eissn: 1879-1913
  dateEnd: 20251014
  omitProxy: false
  ssIdentifier: ssj0001156
  issn: 0002-9149
  databaseCode: 7RV
  dateStart: 20120815
  isFulltext: true
  titleUrlDefault: https://search.proquest.com/nahs
  providerName: ProQuest
– providerCode: PRVPQU
  databaseName: ProQuest Central
  customDbUrl:
  eissn: 1879-1913
  dateEnd: 20251014
  omitProxy: false
  ssIdentifier: ssj0001156
  issn: 0002-9149
  databaseCode: BENPR
  dateStart: 20120815
  isFulltext: true
  titleUrlDefault: https://www.proquest.com/central
  providerName: ProQuest
– providerCode: PRVPQU
  databaseName: Research Library
  customDbUrl:
  eissn: 1879-1913
  dateEnd: 20251014
  omitProxy: false
  ssIdentifier: ssj0001156
  issn: 0002-9149
  databaseCode: M2O
  dateStart: 20120815
  isFulltext: true
  titleUrlDefault: https://search.proquest.com/pqrl
  providerName: ProQuest
link http://cvtisr.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwpV3db9MwELdgQ4gXvmGFURmJB3jIliZ24jwhxlptEivTgKpvluMP0WpLx5Ii8X_xB3LnONnLxpB4qVolZ0fNz3e_O5_vCHljlOU8czwCNh1HrCyLSDEnIseVY6UoTOY7z80-5dOpmM-L4xBwq0NaZacTvaI2K40x8l1gJgzLjwn-_vxHhF2jcHc1tNC4TTaxbTbiPJ_3DheynayjvwW4ApcneHaXO-psqeElYHYX8_U7sQXQ1bbpOu7pbdDkwf8-_UNyP7BP-qGFyyNyy1aPyd2jsL_-hPzuapTQlaP7oXdKQ_ct6pNoDyyeoYcYDm6-A3T0QtNDoN0GkUNnPv5fU2DBIND4FK8KxzmAxdTQiVpgBjwdY4JlTd_iuRYK7DPcSyen64Whvt4y9deum6fVQhiOpJgE-evdU_JtMv768SAKfR0izfOkifDkgcgAC4VQTptcs9iMLBdWWyOc4OCxJzophElTi4TCFSLLkzKJuSpUouL0GdmoVpXdItQ6VcalEjbLLRsVWoBLabktU_iWWq4HhHVvVOpQ9Bx7b5zKLrttKQMQJAJBxrkEIAzITi923lb9uEkg6-AiuyOtoIQl2KWbBPOrBG0dVEktR7JOZCy_IIoRxOgR85SlAyJ6ycCWWhb0L5NudyiVl_P0EB2Q1_1lUDa4g6Qqu1rDPUD-wTimHIZ43q6E_v8BoszBn-Av_j74S3IPnwTN_4hvk43mYm1fkTv6Z7OoL4awfk9mQ7-K_acYks298fT4BH4dJZ__APa-VCU
linkProvider ProQuest
linkToHtml http://cvtisr.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMw1V1Lb9QwEB6VLQIuvCkLBYwEEhzSZhM7cQ4IUXZXu-p2VUGpejOO46i7KtnSZEH9U5z4gczk1UtLufTALVI8tuPM4xt7PAPwKtFWiCAVDqJp1-FxHDmap9JJhU55LKMkKCvP7U_C6VQeHES7K_CruQtDYZWNTiwVdbIwtEe-iciEU_oxKd4ff3eoahSdrjYlNCq22LanP9Fly9-N-_h_X3vecLD3ceTUVQUcI0KvcCjuXQY4k0jq1CSh4W7Ss0JaYxOZSoH-ome8SCa-b8mcpZEMQi_2XKEj7WnXx36vwSr3eSA6sLo1mO5-anU_4qugAdwROh9nd4Y25xv629zgb6d4Ml5mDKWiQ-dbw4vQbmn1hnf-t_W6C7drfM0-VAJxD1Zsdh9u7NQRBA_gd5OFhS1S1q-rwxSsb0ljOlto0xM2pg3v4hCFw8wMG6NjkZBssP3yhCNniPORoCiD2DLqZ4TfWbChnlGMPxtQCGnO3tDNHYb4um7LhkfLWcLKjNKsfHfROJWepQ1XRmGep28fwpcrWbNH0MkWmX0MzKY6dmMtbRBa3ouMRKfZChv7-ORbYbrAGw5Spk7rTtVFjlQTvzdXNeMpYjzlhgoZrwsbLdlxldfkMoKgYU_VXNpFM6PQ8l5GGJ5HaPNaWeaqp3JPueozSQ0JDfn8wud-F2RLWePBCuf9y6DrjVSos3FakejCy_Y1qlM6I9OZXSyxDbo3aP59gV2sVZLXrg-6AgI9JvHk752_gJujvZ2Jmoyn20_hFs2KwE5PrEOnOFnaZ3Dd_Chm-cnzWnsw-HrVAvgHdt2s5g
linkToPdf http://cvtisr.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMw1V1Lb9NAEB6VFFVceD8CBRYJJDi4cWyvvT4gREmsRi1RxKPqbVmv1yJRcUrtgPq_OPHrmLHX7qWlXHrgFsmetb2Zb-ab3dkZgOeZMpyHOXeQTbtOkKaxo4JcODlXeZCKOAvrznP7e9F0Kg4O4tka_G7PwlBaZWsTa0OdLTWtkQ-QmQRUfkzwQW7TImaj5M3Rd4c6SNFOa9tOo1GRXXPyE8O38vVkhP_1C89Lxp_e7Ti2w4CjeeRVDuXAixDfKhYq11mkAzcbGi6MNpnIBcfY0dNeLDLfN-Ta8liEkZd6Llex8pTr47hXYD3yMejpwfr2eDr70PkB5FphS75jDEROzw8NFlvq20KjClBuWVBXD6UGRGd7xvOYb-0Bkxv_89zdhOuWd7O3DVBuwZopbsPGe5tZcAd-tdVZ2DJnI9s1pmIjQ5bU2UZfn7EJLYRXXxE0eq7ZBAOOjDDD9uudj5Ih_0eBqk5uK2icHfzOiiVqTrn_bEyppSV7SSd6GPJuey9LDlfzjNWVpll97bznNPaXFmIZpX-evLoLny9lzu5Br1gW5gEwk6vUTZUwYWSCYawFBtOGm9THX77hug9Bq01S23Lv1HXkULZ5fQtplVCSEko3kqiEfdjqxI6aeicXCYStqsr2MC-6H4ke-SLB6CxBU1ojWsqhLD3pyo-EIAIQrQVwP_D7IDpJyxMb_vcvD91sESJPn9PBow_PustoZmnvTBVmucJ7MOxBWuBzHOJ-g8JufjBE4BhJ8Yd_H_wpbCDq5N5kuvsIrtFLEQca8k3oVccr8xiu6h_VvDx-Yg0Jgy-Xjb8_uPi1qQ
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Analysis+of+Different+Device-Based+Intrathoracic+Impedance+Vectors+for+Detection+of+Heart+Failure+Events+%28from+the+Detect+Fluid+Early+from+Intrathoracic+Impedance+Monitoring+Study%29&rft.jtitle=The+American+journal+of+cardiology&rft.au=Heist%2C+E.+Kevin&rft.au=Herre%2C+John+M.&rft.au=Binkley%2C+Philip+F.&rft.au=Van+Bakel%2C+Adrian+B.&rft.date=2014-10-15&rft.issn=0002-9149&rft.volume=114&rft.issue=8&rft.spage=1249&rft.epage=1256&rft_id=info:doi/10.1016%2Fj.amjcard.2014.07.048&rft.externalDBID=n%2Fa&rft.externalDocID=10_1016_j_amjcard_2014_07_048
thumbnail_m http://cvtisr.summon.serialssolutions.com/2.0.0/image/custom?url=https%3A%2F%2Fcdn.clinicalkey.com%2Fck-thumbnails%2F00029149%2FS0002914914X00184%2Fcov150h.gif