An Automated Algorithm for Obstructive Sleep Apnea Detection Using a Wireless Abdomen-Worn Sensor

Obstructive sleep apnea (OSA) is common among older populations and individuals with cardiovascular diseases. OSA diagnosis is primarily conducted using polysomnography or recommended home sleep apnea test (HSAT) devices. Wireless wearable devices have emerged as promising tools for OSA screening an...

Full description

Saved in:
Bibliographic Details
Published in:Sensors (Basel, Switzerland) Vol. 25; no. 8; p. 2412
Main Authors: Dang, Thi Hang, Kim, Seong-mun, Choi, Min-seong, Hwan, Sung-nam, Min, Hyung-ki, Bien, Franklin
Format: Journal Article
Language:English
Published: Switzerland MDPI AG 10.04.2025
MDPI
Subjects:
ISSN:1424-8220, 1424-8220
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Obstructive sleep apnea (OSA) is common among older populations and individuals with cardiovascular diseases. OSA diagnosis is primarily conducted using polysomnography or recommended home sleep apnea test (HSAT) devices. Wireless wearable devices have emerged as promising tools for OSA screening and follow-up. This study introduces a novel automated algorithm for detecting OSA using abdominal movement signals and acceleration data collected by a wireless abdomen-worn sensor (Soomirang). Thirty-seven subjects underwent overnight monitoring using an HSAT device and the Soomirang system simultaneously. Normal and apnea events were classified using an MLP-Mixer deep learning model based on Soomirang data, which was also used to estimate total sleep time (ST). Pearson correlation and Bland–Altman analyses were conducted to evaluate the agreement of ST and the apnea–hypopnea index (AHI) calculated by the HSAT device and Soomirang. ST demonstrated a correlation of 0.9 with an average time difference of 7.5 min, while AHI showed a correlation of 0.95 with an average AHI difference of 3. The accuracy, sensitivity, and specificity of the Soomirang for detecting OSA were 97.14%, 100%, and 95.45% at AHI ≥ 15, respectively. The proposed algorithm, utilizing data from a wireless abdomen-worn device exhibited excellent performance in detecting moderate to severe OSA. The findings underscored the potential of a simple device as an accessible and effective tool for OSA screening and follow-up.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
ISSN:1424-8220
1424-8220
DOI:10.3390/s25082412