Biological variation: Understanding why it is so important?

This Review will describe the increasing importance of the concepts of biological variation to clinical chemists. The idea of comparison to ‘reference’ is fundamental in measurement. For the biological measurands, that reference is the relevant patient population, a clinical decision point based on...

Celý popis

Uložené v:
Podrobná bibliografia
Vydané v:Practical laboratory medicine Ročník 23; s. e00199
Hlavný autor: Badrick, Tony
Médium: Journal Article
Jazyk:English
Vydavateľské údaje: Netherlands Elsevier B.V 01.01.2021
Elsevier
Predmet:
ISSN:2352-5517, 2352-5517
On-line prístup:Získať plný text
Tagy: Pridať tag
Žiadne tagy, Buďte prvý, kto otaguje tento záznam!
Abstract This Review will describe the increasing importance of the concepts of biological variation to clinical chemists. The idea of comparison to ‘reference’ is fundamental in measurement. For the biological measurands, that reference is the relevant patient population, a clinical decision point based on a trial or an individual patient’s previous results. The idea of using biological variation to set quality goals was then realised for setting Quality Control (QC) and External Quality Assurance (EQA) limits. The current phase of BV integration into practice is using Patient-Based Real-Time Quality Control (PBRTQC) and Patient Based Quality Assurance (PBQA) to detect a change in assay performance. The challenge of personalised medicine is to determine an individual reference interval. The Athletes Biological Passport may provide the solution.
AbstractList This Review will describe the increasing importance of the concepts of biological variation to clinical chemists. The idea of comparison to ‘reference’ is fundamental in measurement. For the biological measurands, that reference is the relevant patient population, a clinical decision point based on a trial or an individual patient’s previous results. The idea of using biological variation to set quality goals was then realised for setting Quality Control (QC) and External Quality Assurance (EQA) limits. The current phase of BV integration into practice is using Patient-Based Real-Time Quality Control (PBRTQC) and Patient Based Quality Assurance (PBQA) to detect a change in assay performance. The challenge of personalised medicine is to determine an individual reference interval. The Athletes Biological Passport may provide the solution.
This Review will describe the increasing importance of the concepts of biological variation to clinical chemists. The idea of comparison to ‘reference’ is fundamental in measurement. For the biological measurands, that reference is the relevant patient population, a clinical decision point based on a trial or an individual patient’s previous results. The idea of using biological variation to set quality goals was then realised for setting Quality Control (QC) and External Quality Assurance (EQA) limits. The current phase of BV integration into practice is using Patient-Based Real-Time Quality Control (PBRTQC) and Patient Based Quality Assurance (PBQA) to detect a change in assay performance. The challenge of personalised medicine is to determine an individual reference interval. The Athletes Biological Passport may provide the solution.
This Review will describe the increasing importance of the concepts of biological variation to clinical chemists. The idea of comparison to 'reference' is fundamental in measurement. For the biological measurands, that reference is the relevant patient population, a clinical decision point based on a trial or an individual patient's previous results. The idea of using biological variation to set quality goals was then realised for setting Quality Control (QC) and External Quality Assurance (EQA) limits. The current phase of BV integration into practice is using Patient-Based Real-Time Quality Control (PBRTQC) and Patient Based Quality Assurance (PBQA) to detect a change in assay performance. The challenge of personalised medicine is to determine an individual reference interval. The Athletes Biological Passport may provide the solution.This Review will describe the increasing importance of the concepts of biological variation to clinical chemists. The idea of comparison to 'reference' is fundamental in measurement. For the biological measurands, that reference is the relevant patient population, a clinical decision point based on a trial or an individual patient's previous results. The idea of using biological variation to set quality goals was then realised for setting Quality Control (QC) and External Quality Assurance (EQA) limits. The current phase of BV integration into practice is using Patient-Based Real-Time Quality Control (PBRTQC) and Patient Based Quality Assurance (PBQA) to detect a change in assay performance. The challenge of personalised medicine is to determine an individual reference interval. The Athletes Biological Passport may provide the solution.
ArticleNumber e00199
Author Badrick, Tony
Author_xml – sequence: 1
  givenname: Tony
  surname: Badrick
  fullname: Badrick, Tony
  email: Tony.badrick@rcpaqap.com.au
  organization: Royal College of Pathologists of Australasia Quality Assurance Programs, St Leonards Sydney, NSW, 2065, Australia
BackLink https://www.ncbi.nlm.nih.gov/pubmed/33490349$$D View this record in MEDLINE/PubMed
BookMark eNqFUU1v1DAQtVARLUt_ARLKkcsuYzuxYxBFUPFRqRIXerYcZ7L1KrEX27uo_x5vU6qWAxwsWzPvvfG895wc-eCRkJcUVhSoeLNZbUfTTSsGDFYIQJV6Qk4Yb9iyaag8evA-JqcpbaBgWikVsGfkmPNaQTkn5N0nF8awdtaM1d5EZ7IL_m115XuMKRvfO7-ufl3fVC5XLlUpVG7ahlg6-cML8nQwY8LTu3tBrr58_nH-bXn5_evF-cfLpW1Yk5cSVDt0lEswvBFSMujrASRSkANCD41QtYGeGUl7LmSHHIwUpuuEEIhNzRfkYtbtg9nobXSTiTc6GKdvCyGutYnZ2RH10PKysVDU0q5WEjoxyBoFo5wjlRSL1tmstd11E_YWfY5mfCT6uOPdtV6HvZYtKFpMW5DXdwIx_NxhynpyyeI4Go9hlzSrW5A1tEoV6KuHs-6H_HG_APgMsDGkFHG4h1DQh5h1WfcQsz7ErOeYC0v9xbIu3-ZWPuzG_3Dfz1wsee0dRp2sQ2-xdxFtLoa6f_J_A8GMwss
CitedBy_id crossref_primary_10_1080_10408363_2025_2555261
crossref_primary_10_1016_j_cca_2021_11_007
crossref_primary_10_1093_clinchem_hvae019
crossref_primary_10_1186_s40798_025_00854_5
crossref_primary_10_1515_cclm_2023_1056
crossref_primary_10_3390_ijms24076628
crossref_primary_10_7759_cureus_36242
crossref_primary_10_1002_mas_21929
crossref_primary_10_1080_10408363_2025_2464244
crossref_primary_10_61568_kbm_2022_017
crossref_primary_10_1515_cclm_2024_0102
crossref_primary_10_1515_cclm_2024_0124
crossref_primary_10_1111_trf_17085
crossref_primary_10_3390_biology13100830
crossref_primary_10_3389_bjbs_2024_12339
crossref_primary_10_1515_cclm_2025_0240
crossref_primary_10_1016_j_ifacol_2025_08_069
crossref_primary_10_1093_jalm_jfac114
crossref_primary_10_1016_j_plabm_2025_e00506
crossref_primary_10_4102_jcmsa_v3i1_148
crossref_primary_10_3390_computation12070137
crossref_primary_10_1152_ajplung_00258_2024
crossref_primary_10_1038_s43586_022_00175_x
crossref_primary_10_1016_j_clinbiochem_2021_05_003
crossref_primary_10_3390_ijms26167970
crossref_primary_10_3390_diagnostics13223453
crossref_primary_10_61568_kbm_2021_011
crossref_primary_10_3892_br_2024_1885
crossref_primary_10_1080_00365513_2025_2512995
crossref_primary_10_1038_s41598_024_53787_6
crossref_primary_10_3390_kinasesphosphatases3030018
crossref_primary_10_1038_s41598_025_16428_0
crossref_primary_10_1016_j_cca_2023_117536
crossref_primary_10_33086_ijmlst_v6i1_4930
Cites_doi 10.1093/biostatistics/kxl009
10.1007/s00769-002-0523-6
10.1515/cclm-2012-0820
10.1373/clinchem.2017.278291
10.1515/cclm-2018-0795
10.1373/clinchem.2011.162107
10.1515/cclm-2014-0914
10.1016/S0009-8981(96)06494-7
10.3109/00365518809088757
10.1080/00365519209104641
10.11613/BM.2019.010902
10.1515/cclm-2013-1090
10.1002/dta.2219
10.1093/labmed/30.5.316
10.1080/00365510410006298
10.1373/clinchem.2018.287037
10.11613/BM.2009.023
10.1016/j.clinbiochem.2018.04.002
10.1016/0009-8981(87)90224-5
10.1093/clinchem/36.9.1625
10.1093/clinchem/9.2.217
10.1093/clinchem/47.8.1547
10.1093/ajcp/71.6.624
10.1007/s00769-003-0727-4
10.1177/0004563220904749
10.1373/clinchem.2019.305482
10.1016/j.clinbiochem.2017.07.004
10.1093/clinchem/45.3.321
10.1016/j.cccn.2003.12.032
10.1080/00365519309085446
10.1214/088342304000000044
10.1093/ajcp/83.2.200
10.1186/1471-2288-12-12
10.1515/CCLM.2000.080
10.1373/clinchem.2016.265058
10.1093/ajcp/50.6.671
10.1016/j.cca.2013.11.003
10.1515/cclm-2016-1077
10.1080/10408363.2020.1765731
10.1080/10408363.2018.1540536
10.1093/ajcp/aqy158
10.1373/clinchem.2011.162271
10.1515/cclm-2014-0739
10.1016/j.clinbiochem.2014.12.016
10.1093/ndt/gfm517
10.1007/s00769-009-0630-8
10.1016/j.clinbiochem.2017.03.009
10.1007/s00769-009-0549-0
10.1258/000456307780945633
10.1136/postgradmedj-2018-135983
10.1080/0025570X.2006.11953386
10.1515/cclm-2017-0772
10.1258/0004563021902161
10.11613/BM.2018.020503
10.1177/0004563215597248
10.1515/CCLM.2010.001
10.2202/1557-4679.1011
10.1515/cclm-2019-0027
10.1093/clinchem/hvaa149
10.1136/bjsports-2014-093560
10.1515/CCLM.2011.149
10.1515/CCLM.2004.118
10.1080/00365519950185247
10.1136/bjsports-2014-093512
10.1080/00365519950185265
10.1038/s41598-017-14172-8
10.1093/ajcp/aqx083
10.3343/alm.2012.32.5.345
10.1515/cclm-2015-0710
10.1373/clinchem.2010.145367
10.1080/00365510500236135
10.3109/10408368909106595
10.1016/j.cca.2013.09.018
10.1353/pbm.1966.0011
10.1373/clinchem.2015.252296
10.1177/0004563215581400
10.1373/clinchem.2016.269258
10.1515/cclm-2019-0658
10.1515/cclm-2020-0343
10.3390/nano9060813
10.1016/j.ecl.2009.11.003
10.1373/clinchem.2014.231258
10.1080/003655101300133630
10.1515/cclm-2013-0021
10.1093/clinchem/20.12.1535
10.1093/clinchem/34.7.1379
10.1016/j.cca.2013.11.022
10.1080/01621459.1979.10481600
10.3109/03009739309179331
10.1016/j.forsciint.2007.04.001
10.1016/j.cca.2019.03.1633
10.3343/alm.2012.32.1.5
10.7326/0003-4819-144-11-200606060-00011
10.1097/EDE.0b013e318261c86f
ContentType Journal Article
Copyright 2020 The Author(s)
2020 The Author(s).
2020 The Author(s) 2020
Copyright_xml – notice: 2020 The Author(s)
– notice: 2020 The Author(s).
– notice: 2020 The Author(s) 2020
DBID 6I.
AAFTH
AAYXX
CITATION
NPM
7X8
5PM
DOA
DOI 10.1016/j.plabm.2020.e00199
DatabaseName ScienceDirect Open Access Titles
Elsevier:ScienceDirect:Open Access
CrossRef
PubMed
MEDLINE - Academic
PubMed Central (Full Participant titles)
DOAJ Directory of Open Access Journals
DatabaseTitle CrossRef
PubMed
MEDLINE - Academic
DatabaseTitleList

MEDLINE - Academic

PubMed
Database_xml – sequence: 1
  dbid: DOA
  name: DOAJ Directory of Open Access Journals
  url: https://www.doaj.org/
  sourceTypes: Open Website
– sequence: 2
  dbid: NPM
  name: PubMed
  url: http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed
  sourceTypes: Index Database
– sequence: 3
  dbid: 7X8
  name: MEDLINE - Academic
  url: https://search.proquest.com/medline
  sourceTypes: Aggregation Database
DeliveryMethod fulltext_linktorsrc
Discipline Medicine
EISSN 2352-5517
ExternalDocumentID oai_doaj_org_article_f83517691c1b4970b6f74e62133e171e
PMC7809190
33490349
10_1016_j_plabm_2020_e00199
S2352551720301621
Genre Journal Article
Review
GroupedDBID 0R~
0SF
4.4
457
53G
6I.
AACTN
AAEDW
AAFTH
AAFWJ
AALRI
AAXUO
ABMAC
ACGFS
ADBBV
ADEZE
AEXQZ
AFPKN
AFTJW
AGHFR
AITUG
AKRWK
ALMA_UNASSIGNED_HOLDINGS
AMRAJ
AOIJS
BCNDV
EBS
EJD
FDB
GROUPED_DOAJ
HYE
KQ8
M~E
NCXOZ
O9-
OK1
ROL
RPM
SSZ
AAYWO
AAYXX
ACVFH
ADCNI
ADVLN
AEUPX
AFJKZ
AFPUW
AIGII
AKBMS
AKYEP
APXCP
CITATION
NPM
7X8
5PM
ID FETCH-LOGICAL-c525t-7098fb1370a3567720d4f07e107fe0d05694a0d2a71d367be30a76abb666ee543
IEDL.DBID DOA
ISICitedReferencesCount 41
ISICitedReferencesURI http://www.webofscience.com/api/gateway?GWVersion=2&SrcApp=Summon&SrcAuth=ProQuest&DestLinkType=CitingArticles&DestApp=WOS_CPL&KeyUT=000609874600005&url=https%3A%2F%2Fcvtisr.summon.serialssolutions.com%2F%23%21%2Fsearch%3Fho%3Df%26include.ft.matches%3Dt%26l%3Dnull%26q%3D
ISSN 2352-5517
IngestDate Fri Oct 03 12:51:37 EDT 2025
Tue Sep 30 16:56:05 EDT 2025
Fri Jul 11 08:48:19 EDT 2025
Mon Jul 21 05:48:03 EDT 2025
Thu Nov 13 04:24:14 EST 2025
Tue Nov 18 21:47:19 EST 2025
Wed Jul 03 05:56:04 EDT 2024
IsDoiOpenAccess true
IsOpenAccess true
IsPeerReviewed true
IsScholarly true
Keywords Analytical goals
Patient based quality assurance
Biological passport
Language English
License This is an open access article under the CC BY-NC-ND license.
2020 The Author(s).
This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-c525t-7098fb1370a3567720d4f07e107fe0d05694a0d2a71d367be30a76abb666ee543
Notes ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
ObjectType-Review-3
content type line 23
OpenAccessLink https://doaj.org/article/f83517691c1b4970b6f74e62133e171e
PMID 33490349
PQID 2480740899
PQPubID 23479
ParticipantIDs doaj_primary_oai_doaj_org_article_f83517691c1b4970b6f74e62133e171e
pubmedcentral_primary_oai_pubmedcentral_nih_gov_7809190
proquest_miscellaneous_2480740899
pubmed_primary_33490349
crossref_primary_10_1016_j_plabm_2020_e00199
crossref_citationtrail_10_1016_j_plabm_2020_e00199
elsevier_sciencedirect_doi_10_1016_j_plabm_2020_e00199
PublicationCentury 2000
PublicationDate 2021-01-01
PublicationDateYYYYMMDD 2021-01-01
PublicationDate_xml – month: 01
  year: 2021
  text: 2021-01-01
  day: 01
PublicationDecade 2020
PublicationPlace Netherlands
PublicationPlace_xml – name: Netherlands
PublicationTitle Practical laboratory medicine
PublicationTitleAlternate Pract Lab Med
PublicationYear 2021
Publisher Elsevier B.V
Elsevier
Publisher_xml – name: Elsevier B.V
– name: Elsevier
References Fraser (bib16) 2001
Williams Roger (bib29) 1956
Linnet (bib84) 1988; 34
Sikaris (bib87) 2012
Skendzel, Barnett, Platt (bib109) 1985; 83
Eknoyan (bib22) 2008; 23
Tan, Markus, Loh (bib97) 2020; 57
Bruns (bib69) 2001; 47
Tyler, Choi, Tewari (bib53) 2020; 20
Ko, Il Park, Hyun, Kim, Park, Shin (bib94) 2017; 148
Petersen (bib2) 2002; 7
Randell, Yenice (bib93) 2019; 56
Oosterhuis, Sandberg (bib112) 2015
Katayev, Fleming (bib132) 2020
Fraser (bib10) 2004
Grasbeck (bib27) 1969; 26
Gräsbeck (bib28) 2004; 42
Perich, Minchinela, Ricós, Fernández-Calle, Alvarez, Doménech, Simón, Biosca, Boned, García-Lario, Cava, Fernández-Fernández, Fraser (bib30) 2015; 53
Westgard (bib117) 2016; 54
Vogenberg, Barash, Pursel (bib38) 2010; vol. 35
Sikaris (bib40) 2014; 35
Westgard, Bayat, Westgard (bib120) 2018; 64
Harris, Yasaka (bib92) 1983
Coskun, Unsal, Serteser (bib123)
Coskun, Unsal, Serteser, Fraterman (bib127) 2009; 14
Plebani, Lippi (bib39) 2013; 51
Petersen, Jørgensen, Brandslund, Olivarius, Stahl (bib59) 2005; 240
Stroobants, Goldschmidt, Plebani (bib76) 2003
Fraser (bib88) 2015; 53
Sheehan, Blennerhassett, Vasikaran (bib65) 2002; 39
Coskun, Serteser, Cavusoglu, Kilercik, Unsal (bib42) 2020
Liu, Tan, Badrick, Loh (bib140) 2017
Fraser (bib11) 2001
Thienpont, Stöckl (bib143) 2018; 42
Frenkel, Farrance, Badrick (bib116) 2019; 495
Jones (bib141) 2016; 53
Solberg (bib102) 1987; 165
Harris (bib113) 1988; 112
Røraas, Støve, Petersen, Sandberg (bib36) 2016; 62
Klee, GG Schryver (bib91) 1999; 59
Van Rossum, Van Den Broek (bib129) 2019; 57
Fraser, Harris (bib35) 1989; 27
Westgard (bib73) 1996; 10
Hyltoft Petersen, Rustad (bib6) 2004; 64
Sottas, Robinson, Giraud, Taroni, Kamber, Mangin, Saugy (bib49) 2006; 2
Gallagher, Mobley, Klee, Schryver (bib8) 2004
Tonks (bib89) 1963; 9
Boyd, Bruns (bib68) 2014; 60
Petersen, Hørder (bib105) 1992; 52
Badrick, Bietenbeck, Katayev, Van Rossum, Cervinski, Loh (bib138) 2020; 66
Faerstein, Winkelstein (bib21) 2012; 23
Westgard, Westgard (bib121) 2016; 53
Coskun, Serteser, Ünsal (bib126) 2019; 29
JCGM (bib115) 2008
Braga, Panteghini (bib146) 2014; 432
Linnet (bib110) 1993; 98
Sottas, Robinson, Rabin, Saugy (bib44) 2011; 57
Hodnett (bib26) 2018; 30
Lobigs, Sottas, Bourdon, Nikolovski, El-Gingo, Varamenti, Peeling, Dawson, Schumacher (bib48) 2018; 10
Saugy, Lundby, Robinson (bib51) 2014; 48
Naugler, Ovens (bib95) 2012; 3
Westgard, Westgard (bib118) 2019; 151
Sottas, Saugy, Saudan (bib47) 2010; 39
Carobene (bib34) 2015
Staub, Lord, Simes, Dyer, Houssami, Chen, Irwig (bib67) 2012; 12
Jones (bib100) 2016; 54
Chai, Ma, Heng, Yoong, Lim, Toh, Loh (bib61) 2017; 7
Oosterhuis, Coskun (bib125) 2018; 28
Poincare (bib23) 1892
Cooper, DeJonge, Ehrmeyer, Yundt-Pacheco, Jansen, Ricós, Plebani (bib111) 2011; 49
Magnusson (bib114) 2014
Pusparum, Ertaylan, Thas (bib41) 2020; 2020
Park, Kim, Lee, Chun, Min (bib96) 2012; 32
Langlois, Chapman, Cobbaert, Mora, Remaley, Ros, Watts, Borén, Baum, Bruckert, Catapano, Descamps, Von Eckardstein, Kamstrup, Kolovou, Kronenberg, Langsted, Pulkki, Rifai, Sypniewska, Wiklund, Nordestgaard (bib63) 2018; 64
Christensen (bib70) 2011; 58
Van Rossum, Kemperman (bib137) 2017; 63
Stahl (bib20) 2006; 79
Fraser, Petersen, Ricos, Haeckel (bib104) 1992; 30
Rustad, Felding, Lahti (bib7) 2004
Fraser (bib14) 2017; 2
Westgard, Carey, Wold (bib72) 1974
Coskun, Braga, Carobene, Tejedor Ganduxe, Aarsand, Fernández-Calle, Díaz-Garzón Marco, Bartlett, Jonker, Aslan, Minchinela, Boned, Gonzalez-Lao, Marques-Garcia, Perich, Ricos, Simón, Sandberg (bib31) 2019
Robinson, Saugy, Vernec, Sottas (bib46) 2011; 57
Harris (bib37) 1974; 12
Vernec (bib52) 2014; 48
Fraser, Petersen, Libeer, Ricosl (bib81) 1997
Van Houcke, Stepman, Thienpont, Fiers, Stove, Couck (bib145) 2013
Bayat (bib122) 2017; 55
De Grande, Goossens, Van Uytfanghe, Stöckl, Thienpont (bib144) 2015; 53
Sottas, Baume, Saudan, Schweizer, Kamber, Saugy (bib45) 2007; 8
Loh, Badrick (bib142) 2017; 2
(bib1) 2008
Petersen, Fraser (bib3) 2010; 15
Hyltoft Petersen, Sandberg, Fraser, Goldschmidt (bib13) 2000; 38
Panteghini, Ceriotti, Jones, Oosterhuis, Plebani, Sandberg (bib55) 2017; 55
Lyon, Kavsak, Lyon, Worster, Lyon (bib64) 2017; 63
Jones, Calleja, Chesher, Parvin, Yundt-Pacheco, Mackay, Badrick (bib130) 2015
Stöckl, Baadenhuijsen, Frasei, Libeer, Ricós (bib98) 1995
Burnett, Ceriotti, Cooper, Parvin, Plebani, Westgard (bib4) 2010; 48
Ricos, Perich, Minchinela, Álvarez, Simón, Biosca, Doménech, Fernández, Jiménez, Garcia-Lario, Cava (bib15) 2009; 19
Elevitch, Barnett, Boroviczeny (bib83) 1979; 71
Lytken Larsen, Fraser, Hyltoft Petersen (bib108) 1991
Petersen, Stöckl, Westgard, Sandberg, Linnet, Thienpont (bib107) 2001
Klee (bib75) 1993; 39
Fleming, Katayev (bib133) 2015; 48
Badrick, Bietenbeck, Katayev, van Rossum, Loh, Cervinski (bib135) 2020
Hens, Berth, Armbruster, Westgard (bib124) 2014; 52
Whyte, Kelly (bib25) 2018; 94
Fraser, Petersen (bib82) 1999; 45
Harris, Kanofsky, Shakarji, Cotlove (bib19) 1970
Gowans, Petersen, Blaabjerg, Hørder (bib101) 1988; 48
Horvath, Bossuyt, Sandberg, John, Monaghan, Verhagen-Kamerbeek, Lennartz, Cobbaert, Ebert, Lord (bib71) 2015
Fraser, Petersen (bib106) 1993; 53
Fraser, Petersen (bib80) 1991
Howanitz, Tetrault, Steindel (bib131) 1997; 260
Oosterhuis, Severens (bib128) 2018; 57
Van Rossum (bib136) 2019; 57
Petersen (bib12) 1999; 59
Panteghini (bib66) 2012
Badrick, Bietenbeck, Cervinski, Katayev, Van Rossum, Loh (bib134) 2019; 65
Fraser, Hyltoft Petersen, Ricos, Haeckel, Fraser (bib5) 1992; vol. 1
Westgard, Westgard (bib74) 2013
Lord, Irwig, Simes (bib57) 2006; 144
Harris (bib85) 1979; 72
Jones, Sikaris, Gill, Jones (bib86) 2012
Van Rossum (bib139) 2019; 57
Jansen, Jassam, Thomas, Perich, Fernandez-Calle, Faria, Correia, Barth, Weykamp, Cobbaert, Thelen, Ricós (bib9) 2014; 432
Sandberg, Fraser, Horvath, Jansen, Jones, Oosterhuis, Petersen, Schimmel, Sikaris, Panteghini (bib56) 2015
Fraser, Hyltoft Petersen, Lytken (bib79) 1990; 36
Berry (bib43) 2004; 19
Fraser, Sandberg (bib17) 2018
Guk, Han, Lim, Jeong, Kang, Lim, Jung (bib54) 2019; 9
Ricós, Iglesias, García-Lario, Simón, Cava, Hernández, Perich, Minchinela, Alvarez, Doménech, Jiménez, Biosca, Tena (bib32) 2007; 44
Hyltoft Petersen P, Jørgensen, Stahl M, N (bib99) 2001; 61
Mackay, Hegedus, Badrick (bib77) 2017; 50
Stamm (bib103) 1982
Karon, Boyd, Klee (bib62) 2010; 56
Pasqualetti, Braga, Panteghini (bib60) 2017; 50
Hawkins (bib119) 2012; 32
Box (bib148) 1979; 74
Ricos, Alvarez, Cava, Garcia-Lario, Hernandez, Jimenez (bib33) 2004; 9
Badrick, Stavelin (bib147) 2020
Krouwer (bib78) 2002
Cotlove, Harris, Williams (bib18) 1970
Horvath, Lord, StJohn, Sandberg, Cobbaert, Lorenz, Monaghan, Verhagen-Kamerbeek, Ebert, Bossuyt (bib58) 2014; 427
Sottas, Saudan, Schweizer, Baume, Mangin, Saugy (bib50) 2008; 174
Murphy (bib24) 1966; 9
Barnett (bib90) 1968; 50
Horvath (10.1016/j.plabm.2020.e00199_bib71) 2015
Fraser (10.1016/j.plabm.2020.e00199_bib106) 1993; 53
Gowans (10.1016/j.plabm.2020.e00199_bib101) 1988; 48
Oosterhuis (10.1016/j.plabm.2020.e00199_bib125) 2018; 28
Jansen (10.1016/j.plabm.2020.e00199_bib9) 2014; 432
Pasqualetti (10.1016/j.plabm.2020.e00199_bib60) 2017; 50
Karon (10.1016/j.plabm.2020.e00199_bib62) 2010; 56
Rustad (10.1016/j.plabm.2020.e00199_bib7) 2004
Panteghini (10.1016/j.plabm.2020.e00199_bib55) 2017; 55
Tonks (10.1016/j.plabm.2020.e00199_bib89) 1963; 9
Petersen (10.1016/j.plabm.2020.e00199_bib2) 2002; 7
Sottas (10.1016/j.plabm.2020.e00199_bib50) 2008; 174
Lytken Larsen (10.1016/j.plabm.2020.e00199_bib108) 1991
Van Rossum (10.1016/j.plabm.2020.e00199_bib129) 2019; 57
Stahl (10.1016/j.plabm.2020.e00199_bib20) 2006; 79
Oosterhuis (10.1016/j.plabm.2020.e00199_bib128) 2018; 57
Westgard (10.1016/j.plabm.2020.e00199_bib120) 2018; 64
Westgard (10.1016/j.plabm.2020.e00199_bib72)
Stöckl (10.1016/j.plabm.2020.e00199_bib98) 1995
Westgard (10.1016/j.plabm.2020.e00199_bib121) 2016; 53
Vogenberg (10.1016/j.plabm.2020.e00199_bib38) 2010; vol. 35
Jones (10.1016/j.plabm.2020.e00199_bib86) 2012
Westgard (10.1016/j.plabm.2020.e00199_bib118) 2019; 151
Murphy (10.1016/j.plabm.2020.e00199_bib24) 1966; 9
Jones (10.1016/j.plabm.2020.e00199_bib141) 2016; 53
Harris (10.1016/j.plabm.2020.e00199_bib85) 1979; 72
Box (10.1016/j.plabm.2020.e00199_bib148) 1979; 74
Coskun (10.1016/j.plabm.2020.e00199_bib42) 2020
Sikaris (10.1016/j.plabm.2020.e00199_bib40) 2014; 35
Christensen (10.1016/j.plabm.2020.e00199_bib70) 2011; 58
De Grande (10.1016/j.plabm.2020.e00199_bib144) 2015; 53
Ricos (10.1016/j.plabm.2020.e00199_bib33) 2004; 9
Liu (10.1016/j.plabm.2020.e00199_bib140) 2017
Faerstein (10.1016/j.plabm.2020.e00199_bib21) 2012; 23
Petersen (10.1016/j.plabm.2020.e00199_bib3) 2010; 15
Horvath (10.1016/j.plabm.2020.e00199_bib58) 2014; 427
Petersen (10.1016/j.plabm.2020.e00199_bib107) 2001
Van Rossum (10.1016/j.plabm.2020.e00199_bib136) 2019; 57
Perich (10.1016/j.plabm.2020.e00199_bib30) 2015; 53
Van Rossum (10.1016/j.plabm.2020.e00199_bib139) 2019; 57
Røraas (10.1016/j.plabm.2020.e00199_bib36) 2016; 62
Van Rossum (10.1016/j.plabm.2020.e00199_bib137) 2017; 63
Braga (10.1016/j.plabm.2020.e00199_bib146) 2014; 432
Petersen (10.1016/j.plabm.2020.e00199_bib12) 1999; 59
Fraser (10.1016/j.plabm.2020.e00199_bib11) 2001
Cotlove (10.1016/j.plabm.2020.e00199_bib18)
Whyte (10.1016/j.plabm.2020.e00199_bib25) 2018; 94
Boyd (10.1016/j.plabm.2020.e00199_bib68) 2014; 60
Harris (10.1016/j.plabm.2020.e00199_bib113) 1988; 112
Linnet (10.1016/j.plabm.2020.e00199_bib84) 1988; 34
Vernec (10.1016/j.plabm.2020.e00199_bib52) 2014; 48
Berry (10.1016/j.plabm.2020.e00199_bib43) 2004; 19
Carobene (10.1016/j.plabm.2020.e00199_bib34) 2015
Harris (10.1016/j.plabm.2020.e00199_bib19)
Hyltoft Petersen P (10.1016/j.plabm.2020.e00199_bib99) 2001; 61
Thienpont (10.1016/j.plabm.2020.e00199_bib143) 2018; 42
JCGM (10.1016/j.plabm.2020.e00199_bib115) 2008
Naugler (10.1016/j.plabm.2020.e00199_bib95) 2012; 3
Williams Roger (10.1016/j.plabm.2020.e00199_bib29) 1956
Ricos (10.1016/j.plabm.2020.e00199_bib15) 2009; 19
Bayat (10.1016/j.plabm.2020.e00199_bib122) 2017; 55
Fraser (10.1016/j.plabm.2020.e00199_bib5) 1992; vol. 1
Westgard (10.1016/j.plabm.2020.e00199_bib117) 2016; 54
(10.1016/j.plabm.2020.e00199_bib1) 2008
Sottas (10.1016/j.plabm.2020.e00199_bib45) 2007; 8
Ricós (10.1016/j.plabm.2020.e00199_bib32) 2007; 44
Badrick (10.1016/j.plabm.2020.e00199_bib147) 2020
Sheehan (10.1016/j.plabm.2020.e00199_bib65) 2002; 39
Krouwer (10.1016/j.plabm.2020.e00199_bib78)
Fraser (10.1016/j.plabm.2020.e00199_bib17) 2018
Westgard (10.1016/j.plabm.2020.e00199_bib73) 1996; 10
Gallagher (10.1016/j.plabm.2020.e00199_bib8) 2004
Badrick (10.1016/j.plabm.2020.e00199_bib135) 2020
Hyltoft Petersen (10.1016/j.plabm.2020.e00199_bib6) 2004; 64
Cooper (10.1016/j.plabm.2020.e00199_bib111) 2011; 49
Stroobants (10.1016/j.plabm.2020.e00199_bib76) 2003
Katayev (10.1016/j.plabm.2020.e00199_bib132) 2020
Badrick (10.1016/j.plabm.2020.e00199_bib134) 2019; 65
Klee (10.1016/j.plabm.2020.e00199_bib91) 1999; 59
Coskun (10.1016/j.plabm.2020.e00199_bib123)
Bruns (10.1016/j.plabm.2020.e00199_bib69) 2001; 47
Panteghini (10.1016/j.plabm.2020.e00199_bib66) 2012
Fraser (10.1016/j.plabm.2020.e00199_bib79) 1990; 36
Hawkins (10.1016/j.plabm.2020.e00199_bib119) 2012; 32
Plebani (10.1016/j.plabm.2020.e00199_bib39) 2013; 51
Barnett (10.1016/j.plabm.2020.e00199_bib90) 1968; 50
Coskun (10.1016/j.plabm.2020.e00199_bib127) 2009; 14
Fraser (10.1016/j.plabm.2020.e00199_bib10) 2004
Elevitch (10.1016/j.plabm.2020.e00199_bib83) 1979; 71
Saugy (10.1016/j.plabm.2020.e00199_bib51) 2014; 48
Linnet (10.1016/j.plabm.2020.e00199_bib110) 1993; 98
Gräsbeck (10.1016/j.plabm.2020.e00199_bib28) 2004; 42
Mackay (10.1016/j.plabm.2020.e00199_bib77) 2017; 50
Harris (10.1016/j.plabm.2020.e00199_bib37) 1974; 12
Coskun (10.1016/j.plabm.2020.e00199_bib31) 2019
Loh (10.1016/j.plabm.2020.e00199_bib142) 2017; 2
Tan (10.1016/j.plabm.2020.e00199_bib97) 2020; 57
Skendzel (10.1016/j.plabm.2020.e00199_bib109) 1985; 83
Fraser (10.1016/j.plabm.2020.e00199_bib35) 1989; 27
Jones (10.1016/j.plabm.2020.e00199_bib100) 2016; 54
Lyon (10.1016/j.plabm.2020.e00199_bib64) 2017; 63
Klee (10.1016/j.plabm.2020.e00199_bib75) 1993; 39
Lord (10.1016/j.plabm.2020.e00199_bib57) 2006; 144
Park (10.1016/j.plabm.2020.e00199_bib96) 2012; 32
Ko (10.1016/j.plabm.2020.e00199_bib94) 2017; 148
Frenkel (10.1016/j.plabm.2020.e00199_bib116) 2019; 495
Jones (10.1016/j.plabm.2020.e00199_bib130) 2015
Poincare (10.1016/j.plabm.2020.e00199_bib23) 1892
Fraser (10.1016/j.plabm.2020.e00199_bib16) 2001
Fraser (10.1016/j.plabm.2020.e00199_bib88) 2015; 53
Fraser (10.1016/j.plabm.2020.e00199_bib104) 1992; 30
Magnusson (10.1016/j.plabm.2020.e00199_bib114) 2014
Fraser (10.1016/j.plabm.2020.e00199_bib82) 1999; 45
Sottas (10.1016/j.plabm.2020.e00199_bib49) 2006; 2
Van Houcke (10.1016/j.plabm.2020.e00199_bib145) 2013
Hodnett (10.1016/j.plabm.2020.e00199_bib26) 2018; 30
Harris (10.1016/j.plabm.2020.e00199_bib92)
Oosterhuis (10.1016/j.plabm.2020.e00199_bib112) 2015
Stamm (10.1016/j.plabm.2020.e00199_bib103) 1982
Fraser (10.1016/j.plabm.2020.e00199_bib81) 1997
Petersen (10.1016/j.plabm.2020.e00199_bib59) 2005; 240
Lobigs (10.1016/j.plabm.2020.e00199_bib48) 2018; 10
Sottas (10.1016/j.plabm.2020.e00199_bib44) 2011; 57
Fraser (10.1016/j.plabm.2020.e00199_bib14) 2017; 2
Hyltoft Petersen (10.1016/j.plabm.2020.e00199_bib13) 2000; 38
Grasbeck (10.1016/j.plabm.2020.e00199_bib27) 1969; 26
Hens (10.1016/j.plabm.2020.e00199_bib124) 2014; 52
Staub (10.1016/j.plabm.2020.e00199_bib67) 2012; 12
Badrick (10.1016/j.plabm.2020.e00199_bib138) 2020; 66
Coskun (10.1016/j.plabm.2020.e00199_bib126) 2019; 29
Guk (10.1016/j.plabm.2020.e00199_bib54) 2019; 9
Robinson (10.1016/j.plabm.2020.e00199_bib46) 2011; 57
Sottas (10.1016/j.plabm.2020.e00199_bib47) 2010; 39
Chai (10.1016/j.plabm.2020.e00199_bib61) 2017; 7
Fraser (10.1016/j.plabm.2020.e00199_bib80) 1991
Petersen (10.1016/j.plabm.2020.e00199_bib105) 1992; 52
Langlois (10.1016/j.plabm.2020.e00199_bib63) 2018; 64
Eknoyan (10.1016/j.plabm.2020.e00199_bib22) 2008; 23
Sandberg (10.1016/j.plabm.2020.e00199_bib56) 2015
Burnett (10.1016/j.plabm.2020.e00199_bib4) 2010; 48
Solberg (10.1016/j.plabm.2020.e00199_bib102) 1987; 165
Howanitz (10.1016/j.plabm.2020.e00199_bib131) 1997; 260
Westgard (10.1016/j.plabm.2020.e00199_bib74) 2013
Randell (10.1016/j.plabm.2020.e00199_bib93) 2019; 56
Fleming (10.1016/j.plabm.2020.e00199_bib133) 2015; 48
Tyler (10.1016/j.plabm.2020.e00199_bib53) 2020; 20
Sikaris (10.1016/j.plabm.2020.e00199_bib87) 2012
Pusparum (10.1016/j.plabm.2020.e00199_bib41) 2020; 2020
References_xml – ident: bib123
  article-title: Six sigma as a quality management tool: evaluation of performance in laboratory medicine 247 X six sigma as a quality management tool: evaluation of performance in laboratory medicine
– volume: 57
  start-page: 1329
  year: 2019
  end-page: 1338
  ident: bib129
  article-title: Design and implementation of quality control plans that integrate moving average and internal quality control: incorporating the best of both worlds
  publication-title: Clin. Chem. Lab. Med.
– volume: 98
  start-page: 349
  year: 1993
  end-page: 354
  ident: bib110
  article-title: 6.1.2.4 analytical goals for accuracy and precision of Plasma creatinine determinations evaluated by Reference method measurements
  publication-title: Ups. J. Med. Sci.
– volume: 23
  start-page: 762
  year: 2012
  ident: bib21
  article-title: Adolphe quetelet: statistician and more
  publication-title: Epidemiology
– volume: 44
  start-page: 343
  year: 2007
  end-page: 352
  ident: bib32
  article-title: Within-subject biological variation in disease: collated data and clinical consequences
  publication-title: Ann. Clin. Biochem.
– volume: 59
  start-page: 509
  year: 1999
  end-page: 512
  ident: bib91
  article-title: Analytical bias specifications based on the analysis of effects on performance of medical guidelines
  publication-title: Scand. J. Clin. Lab. Invest.
– volume: 57
  start-page: 830
  year: 2011
  end-page: 832
  ident: bib46
  article-title: The athlete biological passport: an effective tool in the fight against doping
  publication-title: Clin. Chem.
– start-page: 90
  year: 2008
  ident: bib1
  article-title: International vocabulary of metrology - basic and general concepts and associated terms (VIM)
  publication-title: Bipm
– year: 1991
  ident: bib80
  article-title: The Importance of Imprecision
– volume: 19
  start-page: 175
  year: 2004
  end-page: 187
  ident: bib43
  article-title: Bayesian statistics and the efficiency and ethics of clinical trials
  publication-title: Stat. Sci.
– year: 1970
  ident: bib18
  article-title: Biological and analytic components of variation in long-term studies of serum constituents in normal subjects III. Physiological and medical implications
– year: 2001
  ident: bib11
  article-title: Biological Variation and Quality for POCT
– volume: 2
  year: 2006
  ident: bib49
  article-title: Statistical classification of abnormal blood profiles in athletes
  publication-title: Int. J. Biostat.
– volume: 48
  start-page: 757
  year: 1988
  end-page: 764
  ident: bib101
  article-title: Analytical goals for the acceptance of common reference intervals for laboratories throughout a geographical area
  publication-title: Scand. J. Clin. Lab. Invest.
– volume: 28
  year: 2018
  ident: bib125
  article-title: Sigma metrics in laboratory medicine revisited: we are on the right road with the wrong map
  publication-title: Biochem. Med.
– volume: 59
  start-page: 517
  year: 1999
  end-page: 521
  ident: bib12
  article-title: Quality specifications based on the analysis of effects of performance on clinical decision-making
  publication-title: Scand. J. Clin. Lab. Invest.
– volume: 2
  year: 2017
  ident: bib14
  article-title: Biological variation: a rapidly evolving aspect of laboratory medicine
  publication-title: J. Lab. Precis. Med.
– year: 1995
  ident: bib98
  article-title: Desirable Routine Analytical Goals for Quantities A Ssayed in Serum Discussion Paper from the Members of the External Quality Assessment (EQA) Working Group A 1) on Analytical Goals in Laboratory Medicine
– volume: 57
  start-page: 773
  year: 2019
  end-page: 782
  ident: bib136
  article-title: Moving average quality control: principles, practical application and future perspectives
  publication-title: Clin. Chem. Lab. Med.
– volume: 42
  start-page: 289
  year: 2018
  end-page: 296
  ident: bib143
  article-title: Percentiler and Flagger-low-cost, on-line monitoring of laboratory and manufacturer data and significant surplus to current external quality assessment
  publication-title: J. Lab. Med.
– start-page: 19
  year: 2004
  end-page: 24
  ident: bib10
  article-title: Test result variation and the quality of evidence-based clinical guidelines
  publication-title: Clin. Chim. Acta
– volume: 57
  start-page: 12
  year: 2018
  end-page: 17
  ident: bib128
  article-title: Performance specifications and six sigma theory: clinical chemistry and industry compared
  publication-title: Clin. Biochem.
– volume: 9
  start-page: 128
  year: 2004
  end-page: 131
  ident: bib33
  article-title: etal, Integration of data derived from biological variation into the quality management system
  publication-title: Accred Qual. Assur.
– year: 2020
  ident: bib135
  article-title: Implementation of patient-based real-time quality control
  publication-title: Crit. Rev. Clin. Lab Sci.
– volume: 19
  start-page: 250
  year: 2009
  end-page: 259
  ident: bib15
  article-title: Application of biological variation – a review
  publication-title: Biochem. Med.
– volume: 148
  start-page: 323
  year: 2017
  end-page: 329
  ident: bib94
  article-title: Utility of reference change values for delta check limits
  publication-title: Am. J. Clin. Pathol.
– volume: 64
  start-page: 1006
  year: 2018
  end-page: 1033
  ident: bib63
  article-title: Quantifying atherogenic lipoproteins: current and future challenges in the era of personalized medicine and very low concentrations of ldl cholesterol. a consensus statement from EAS and EFLM
  publication-title: Clin. Chem.
– volume: 10
  start-page: 294
  year: 2018
  end-page: 300
  ident: bib48
  article-title: A step towards removing plasma volume variance from the Athlete’s Biological Passport: the use of biomarkers to describe vascular volumes from a simple blood test
  publication-title: Drug Test. Anal.
– year: 1983
  ident: bib92
  article-title: On the calculation of a “reference change” for comparing two consecutive measurements
– volume: 165
  start-page: 111
  year: 1987
  end-page: 118
  ident: bib102
  article-title: The concept of reference intervals
  publication-title: Clin. Chim. Acta
– volume: 12
  year: 2012
  ident: bib67
  article-title: Using patient management as a surrogate for patient health outcomes in diagnostic test evaluation
  publication-title: BMC Med. Res. Methodol.
– volume: 50
  start-page: 671
  year: 1968
  end-page: 676
  ident: bib90
  article-title: Medical significance of laboratory values
  publication-title: Am. J. Clin. Pathol.
– volume: 48
  start-page: 41
  year: 2010
  end-page: 52
  ident: bib4
  article-title: Collective opinion paper on findings of the 2009 convocation of experts on quality control
  publication-title: Clin. Chem. Lab. Med.
– volume: 48
  start-page: 817
  year: 2014
  end-page: 819
  ident: bib52
  article-title: The athlete biological passport: an integral element of innovative strategies in antidoping
  publication-title: Br. J. Sports Med.
– year: 1892
  ident: bib23
  article-title: Thermodynamique
– volume: 94
  start-page: 613
  year: 2018
  end-page: 616
  ident: bib25
  article-title: The normal range: it is not normal and it is not a range
  publication-title: Postgrad. Med.
– year: 2012
  ident: bib86
  article-title: Commentary “Allowable Limits of Performance” for External Quality Assurance Programs-An Approach to Application of the Stockholm Criteria by the RCPA Quality Assurance Programs
– volume: 47
  start-page: 1547
  year: 2001
  end-page: 1552
  ident: bib69
  article-title: Laboratory related outcomes in healthcare
  publication-title: Clin. Chem.
– volume: 50
  start-page: 1136
  year: 2017
  end-page: 1144
  ident: bib77
  article-title: Assay stability, the missing component of the error budget
  publication-title: Clin. Biochem.
– volume: 61
  start-page: 191
  year: 2001
  end-page: 204
  ident: bib99
  article-title: Evaluation of systematic and random factors in measurements of fasting plasma glucose as the basis for analytical quality specifications in the diagnosis of diabetes. 3. Impact of the new WHO and ADA recommendations on diagnosis of diabetes mellitus
  publication-title: Scand. J. Clin. Lab. Invest.
– volume: 432
  start-page: 55
  year: 2014
  end-page: 61
  ident: bib146
  article-title: Verification of in vitro medical diagnostics (IVD) metrological traceability: responsibilities and strategies
  publication-title: Clin. Chim. Acta
– start-page: 1
  year: 2020
  end-page: 7
  ident: bib132
  article-title: Past, present, and future of laboratory quality control: patient-based real-time quality control or when getting more quality at less cost is not wishful thinking
  publication-title: J. Precis. Lab. Med.
– volume: 58
  year: 2011
  ident: bib70
  article-title: Doctor OF medical science Danish medical bulletin
  publication-title: Dan. Med. Bull.
– volume: 8
  start-page: 285
  year: 2007
  end-page: 296
  ident: bib45
  article-title: Bayesian detection of abnormal values in longitudinal biomarkers with an application to T/E ratio
  publication-title: Biostatistics
– volume: 55
  start-page: 1702
  year: 2017
  end-page: 1708
  ident: bib122
  article-title: Selecting multi-rule quality control procedures based on patient risk
  publication-title: Clin. Chem. Lab. Med.
– volume: 65
  year: 2019
  ident: bib134
  article-title: Patient-based real-time quality control: review and recommendations
  publication-title: Clin. Chem.
– start-page: 925
  year: 2015
  end-page: 937
  ident: bib112
  article-title: Proposal for the modification of the conventional model for establishing performance specifications
  publication-title: Clin. Chem. Lab. Med
– volume: 48
  start-page: 827
  year: 2014
  end-page: 832
  ident: bib51
  article-title: Monitoring of biological markers indicative of doping: the athlete biological passport
  publication-title: Br. J. Sports Med.
– volume: 53
  start-page: 1197
  year: 2015
  end-page: 1204
  ident: bib144
  article-title: On-line flagging monitoring - a new quality management tool for the analytical phase
  publication-title: Clin. Chem. Lab. Med.
– volume: 15
  start-page: 323
  year: 2010
  end-page: 330
  ident: bib3
  article-title: Strategies to set global analytical quality specifications in laboratory medicine: 10 years on from the Stockholm consensus conference
  publication-title: Accred Qual. Assur.
– volume: 52
  start-page: 65
  year: 1992
  end-page: 87
  ident: bib105
  article-title: Influence of analytical quality on test results
  publication-title: Scand. J. Clin. Lab. Invest.
– volume: 66
  start-page: 1140
  year: 2020
  end-page: 1145
  ident: bib138
  article-title: Patient-based real time QC
  publication-title: Clin. Chem.
– volume: 49
  start-page: 793
  year: 2011
  end-page: 802
  ident: bib111
  article-title: Collective opinion paper on findings of the 2010 convocation of experts on laboratory quality
  publication-title: Clin. Chem. Lab. Med.
– year: 1956
  ident: bib29
  article-title: Biochemical Individuality: the Basis for the Genetrophic Concept
– start-page: 833
  year: 2015
  end-page: 835
  ident: bib56
  article-title: Defining analytical performance specifications: consensus statement from the 1st strategic conference of the European Federation of clinical chemistry and laboratory medicine
  publication-title: Clin. Chem. Lab. Med
– volume: 3
  start-page: 5
  year: 2012
  ident: bib95
  article-title: How useful are delta checks in the 21 st century? A stochastic-dynamic model of specimen mix-up and detection
  publication-title: J. Pathol. Inf.
– volume: 32
  start-page: 345
  year: 2012
  end-page: 354
  ident: bib96
  article-title: New decision criteria for selecting delta check methods based on the ratio of the delta difference to the width of the reference range can be generally applicable for each clinical chemistry test item
  publication-title: Ann. Lab. Med.
– year: 2012
  ident: bib87
  article-title: Application of the Stockholm Hierarchy to Defining the Quality of Reference Intervals and Clinical Decision Limits
– year: 1974
  ident: bib72
  article-title: Criteria for judging precision and accuracy in method development and evaluation
– volume: 14
  start-page: 547
  year: 2009
  end-page: 552
  ident: bib127
  article-title: Towards standardization of external quality assessment schemes by using bias values based on biological variation
  publication-title: Accred Qual. Assur.
– volume: 432
  start-page: 90
  year: 2014
  end-page: 98
  ident: bib9
  article-title: A category 1 EQA scheme for comparison of laboratory performance and method performance: an international pilot study in the framework of the Calibration 2000 project
  publication-title: Clin. Chim. Acta
– start-page: 1
  year: 2013
  end-page: 6
  ident: bib74
  article-title: Total analytic error; from concept to application
  publication-title: Clin. Lab. News.
– volume: 9
  start-page: 217
  year: 1963
  end-page: 233
  ident: bib89
  article-title: A study of the accuracy and precision of clinical chemistry determinations in 170 Canadian laboratories
  publication-title: Clin. Chem.
– volume: 7
  start-page: 488
  year: 2002
  end-page: 493
  ident: bib2
  article-title: Importance of the choice of assumptions and models in the estimation of analytical quality specifications
  publication-title: Accred Qual. Assur.
– volume: 57
  start-page: 969
  year: 2011
  end-page: 976
  ident: bib44
  article-title: The athlete biological passport
  publication-title: Clin. Chem.
– year: 2002
  ident: bib78
  article-title: Setting performance goals and evaluating total analytical error for diagnostic assays
– volume: 62
  start-page: 725
  year: 2016
  end-page: 736
  ident: bib36
  article-title: Biological variation: the effect of different distributions on estimated within-person variation and reference change values
  publication-title: Clin. Chem.
– year: 2008
  ident: bib115
  article-title: Evaluation of Measurement Data — Guide to the Expression of Uncertainty in Measurement, Paris
– volume: 53
  start-page: 299
  year: 2015
  end-page: 305
  ident: bib30
  article-title: Biological variation database: structure and criteria used for generation and update
  publication-title: Clin. Chem. Lab. Med.
– year: 2019
  ident: bib31
  article-title: Systematic review and meta-analysis of within-subject and between-subject biological variation estimates of 20 haematological parameters
  publication-title: Clin. Chem. Lab. Med.
– volume: 12
  start-page: 1535
  year: 1974
  end-page: 1542
  ident: bib37
  article-title: Effects of intra-and interindividual variation on the appropriate use of normal ranges
  publication-title: Clin. Chem.
– start-page: 841
  year: 2015
  end-page: 848
  ident: bib71
  article-title: Setting analytical performance specifications based on outcome studies - is it possible?
  publication-title: Clin. Chem. Lab. Med
– volume: 53
  start-page: 8
  year: 1993
  end-page: 9
  ident: bib106
  article-title: Quality goals in external quality assessment are best based on biology
  publication-title: Scand. J. Clin. Lab. Invest.
– volume: 29
  start-page: 142
  year: 2019
  end-page: 148
  ident: bib126
  article-title: Sigma metric revisited: true known mistakes
  publication-title: Biochem. Med.
– volume: 51
  start-page: 703
  year: 2013
  end-page: 706
  ident: bib39
  article-title: Personalized (laboratory) medicine: a bridge to the future
  publication-title: Clin. Chem. Lab. Med.
– volume: 30
  start-page: 311
  year: 1992
  end-page: 317
  ident: bib104
  article-title: Proposed quality specifications for the imprecision and inaccuracy of analytical systems for clinical chemistry
  publication-title: Eur. J. Clin. Chem. Clin. Biochem.
– volume: 64
  start-page: 289
  year: 2018
  end-page: 296
  ident: bib120
  article-title: Planning risk-based SQC schedules for bracketed operation of continuous production analyzers
  publication-title: Clin. Chem.
– volume: 63
  start-page: 1040
  year: 2017
  end-page: 1041
  ident: bib137
  article-title: Moving average for continuous quality control: time to move to implementation in daily practice?
  publication-title: Clin. Chem.
– year: 2020
  ident: bib42
  article-title: A New Model to Determine the Personal Reference Interval of Tests in Laboratory Medicine: A Preliminary Study
– volume: 144
  start-page: 850
  year: 2006
  end-page: 855
  ident: bib57
  article-title: When is measuring sensitivity and specificity sufficient to evaluate a diagnostic test, and when do we need randomized trials?
  publication-title: Ann. Intern. Med.
– volume: 48
  start-page: 508
  year: 2015
  end-page: 513
  ident: bib133
  article-title: Changing the paradigm of laboratory quality control through implementation of real-time test results monitoring:
  publication-title: Clin. Biochem.
– volume: 7
  year: 2017
  ident: bib61
  article-title: Impact of analytical and biological variations on classification of diabetes using fasting plasma glucose, oral glucose tolerance test and HbA1c
  publication-title: Sci. Rep.
– volume: 45
  start-page: 321
  year: 1999
  end-page: 323
  ident: bib82
  article-title: Analytical performance characteristics should Be judged against objective quality specifications
  publication-title: Clin. Chem.
– volume: 57
  start-page: 215
  year: 2020
  end-page: 222
  ident: bib97
  article-title: An approach to optimize delta checks in test panels – the effect of the number of rules included
  publication-title: Ann. Clin. Biochem.
– volume: 9
  start-page: 1
  year: 2019
  end-page: 23
  ident: bib54
  article-title: Evolution of wearable devices with real-time disease monitoring for personalized healthcare
  publication-title: Nanomaterials
– volume: 39
  start-page: 59
  year: 2010
  end-page: 73
  ident: bib47
  article-title: Endogenous steroid profiling in the athlete biological passport
  publication-title: Endocrinol Metab. Clin. N. Am.
– volume: 56
  start-page: 1091
  year: 2010
  end-page: 1097
  ident: bib62
  article-title: Glucose meter performance criteria for tight gycemic control estimated by simulation modeling
  publication-title: Clin. Chem.
– year: 1997
  ident: bib81
  article-title: Proposals for Setting Generally Applicable Quality Goals Solely Based on Biology
– volume: 38
  start-page: 545
  year: 2000
  end-page: 551
  ident: bib13
  article-title: A model for setting analytical quality specifications and design of control for measurements on the ordinal scale
  publication-title: Clin. Chem. Lab. Med.
– volume: 54
  start-page: 1303
  year: 2016
  end-page: 1307
  ident: bib100
  article-title: Measurement uncertainty for clinical laboratories-A revision of the concept
  publication-title: Clin. Chem. Lab. Med.
– volume: vol. 1
  year: 1992
  ident: bib5
  publication-title: Quality Specifications for Imprecision and Inaccuracy Proposed Quality Specifications for the Imprecision and Inaccuracy of Analytical Systems for Clinical Chemistry
– start-page: 871
  year: 2015
  end-page: 877
  ident: bib34
  article-title: Reliability of biological variation data available in an online database: need for improvement
  publication-title: Clin. Chem. Lab. Med
– volume: 34
  start-page: 1379
  year: 1988
  end-page: 1386
  ident: bib84
  article-title: A review on the methodology for assessing diagnostic tests
  publication-title: Clin. Chem.
– year: 1970
  ident: bib19
  article-title: Biological and AnalyticComponentsof variationin long-TermStudiesof serum constituentsin Normal Subjects II. Estimating biological components of variation
– volume: 53
  start-page: 837
  year: 2015
  end-page: 840
  ident: bib88
  article-title: The 1999 Stockholm Consensus Conference on quality specifications in laboratory medicine
  publication-title: Clin. Chem. Lab. Med.
– volume: 36
  start-page: 1625
  year: 1990
  ident: bib79
  article-title: Setting analytical goals for random analytical situations
  publication-title: Clin. Chem.
– volume: 2020
  start-page: 334
  year: 2020
  end-page: 347
  ident: bib41
  publication-title: Computational Science – ICCS
– volume: vol. 35
  year: 2010
  ident: bib38
  publication-title: Personalized Medicine - Part 1: Evolution and Development into Theranostics
– year: 2004
  ident: bib7
  article-title: Proposal for Guidelines to Establish Common Biological Reference Intervals in Large Geographical Areas for Biochemical Quantities Measured Frequently in Serum and Plasma
– volume: 56
  start-page: 75
  year: 2019
  end-page: 97
  ident: bib93
  article-title: Delta Checks in the clinical laboratory
  publication-title: Crit. Rev. Clin. Lab Sci.
– volume: 240
  start-page: 51
  year: 2005
  end-page: 60
  ident: bib59
  article-title: Consequences of bias and imprecision in measurements of glucose and hba1c for the diagnosis and prognosis of diabetes mellitus
  publication-title: Scand. J. Clin. Lab. Investig. Suppl.
– volume: 53
  start-page: 133
  year: 2016
  end-page: 140
  ident: bib141
  article-title: Average of delta: a new quality control tool for clinical laboratories
  publication-title: Ann. Clin. Biochem.
– year: 2017
  ident: bib140
  article-title: Moving standard deviation and moving sum of outliers as quality tools for monitoring analytical precision
  publication-title: Clin. Biochem.
– year: 2018
  ident: bib17
  article-title: Tietz Textbook of Chemistry and Molecular Diagnostics - Chapter 7 Biological Variation
– year: 2001
  ident: bib107
  article-title: Models for Combining Random and Systematic Errors. Assumptions and Consequences for Different Models
– volume: 32
  start-page: 5
  year: 2012
  end-page: 16
  ident: bib119
  article-title: Managing the pre- and post-analytical phases of the total testing process
  publication-title: Ann. Lab. Med.
– year: 2015
  ident: bib130
  article-title: Collective Opinion Paper on a 2013 AACB Workshop of Experts Seeking Harmonisation of Approaches to Setting a Laboratory Quality Control Policy
– volume: 495
  start-page: 129
  year: 2019
  end-page: 138
  ident: bib116
  article-title: Bias in analytical chemistry: a review of selected procedures for incorporating uncorrected bias into the expanded uncertainty of analytical measurements and a graphical method for evaluating the concordance of reference and test procedures
  publication-title: Clin. Chim. Acta
– volume: 427
  start-page: 49
  year: 2014
  end-page: 57
  ident: bib58
  article-title: From biomarkers to medical tests: the changing landscape of test evaluation
  publication-title: Clin. Chim. Acta
– volume: 10
  start-page: 377
  year: 1996
  end-page: 384
  ident: bib73
  article-title: Error budgets for quality management: practical tools for planning and assuring the analytical quality of testing processes
  publication-title: Clin. Lab. Manag. Rev. Offic. Publ.
– volume: 74
  start-page: 1
  year: 1979
  end-page: 4
  ident: bib148
  article-title: Some problems of statistics and everyday life
  publication-title: J. Am. Stat. Assoc.
– volume: 112
  start-page: 416
  year: 1988
  end-page: 420
  ident: bib113
  article-title: Proposed goals for analytical precision and accuracy in single-point diagnostic testing. Theoretical basis and comparison with data from the College of American Pathologists proficiency surveys
  publication-title: Arch. Pathol. Lab Med.
– year: 2013
  ident: bib145
  article-title: Long-term stability of laboratory tests and practical implications for quality management
  publication-title: Clin. Chem. Lab. Med.
– year: 2001
  ident: bib16
  article-title: Biological Variation: from Principles to Practice
– year: 2020
  ident: bib147
  article-title: Harmonising EQA schemes the next frontier: challenging the status quo
  publication-title: Clin. Chem. Lab. Med.
– year: 2004
  ident: bib8
  article-title: The Impact of Calibration Error in Medical Decision Error
– volume: 54
  start-page: 223
  year: 2016
  end-page: 233
  ident: bib117
  article-title: Useful measures and models for analytical quality management in medical laboratories
  publication-title: Clin. Chem. Lab. Med.
– volume: 72
  start-page: 374
  year: 1979
  end-page: 382
  ident: bib85
  article-title: Statistical principles underlying analytic goal-setting in clinical chemistry
  publication-title: Am. J. Clin. Pathol.
– start-page: 169
  year: 2003
  end-page: 176
  ident: bib76
  article-title: Error budget calculations in laboratory medicine: linking the concepts of biological variation and allowable medical errors
  publication-title: Clin. Chim. Acta
– year: 2014
  ident: bib114
  article-title: B and Örnemark, Eurachem Guide: the Fitness for Purpose of Analytical Methods – A Laboratory Guide to Method Validation and Related Topics
– volume: 26
  year: 1969
  ident: bib27
  article-title: Saris NE, establishment and use of normal values
  publication-title: Establ. Use Norm. Values.
– volume: 27
  start-page: 409
  year: 1989
  end-page: 437
  ident: bib35
  article-title: Generation and application of data on biological variation in clinical chemistry
  publication-title: Crit. Rev. Clin. Lab Sci.
– volume: 2
  year: 2017
  ident: bib142
  article-title: Using next generation electronic medical records for laboratory quality monitoring
  publication-title: J. Lab. Precis. Med.
– volume: 20
  start-page: 17
  year: 2020
  end-page: 25
  ident: bib53
  article-title: Real-time, personalized medicine through wearable sensors and dynamic predictive modeling: a new paradigm for clinical medicine
  publication-title: Curr. Opin. Struct. Biol.
– volume: 42
  start-page: 692
  year: 2004
  end-page: 697
  ident: bib28
  article-title: The evolution of the reference value concept
  publication-title: Clin. Chem. Lab. Med.
– volume: 39
  start-page: 231
  year: 2002
  end-page: 236
  ident: bib65
  article-title: Decision limit for troponin I and assay performance
  publication-title: Ann. Clin. Biochem.
– volume: 30
  start-page: 316
  year: 2018
  end-page: 323
  ident: bib26
  article-title: Proficiency Testing: we all do it - but what do the results mean?
  publication-title: Lab. Med.
– volume: 9
  start-page: 333
  year: 1966
  end-page: 348
  ident: bib24
  article-title: A scientific viewpoint on normalcy
  publication-title: Perspect. Biol. Med.
– volume: 260
  start-page: 163
  year: 1997
  end-page: 174
  ident: bib131
  article-title: Clinical laboratory quality control: a costly process now out of control
  publication-title: Clin. Chim. Acta
– volume: 23
  start-page: 47
  year: 2008
  end-page: 51
  ident: bib22
  article-title: Adolphe Quetelet (1796-1874) - the average man and indices of obesity
  publication-title: Nephrol. Dial. Transplant.
– year: 2012
  ident: bib66
  article-title: Laboratory and Clinical Issues Affecting the Measurement and Reporting of Cardiac Troponins: A Guide for Clinical Laboratories. Chapter 8: Quality Requirements for Troponin Assays - an Overview
– volume: 57
  year: 2019
  ident: bib139
  article-title: Moving average quality control: principles, practical application and future perspectives
  publication-title: Clin. Chem. Lab. Med.
– volume: 35
  start-page: 3
  year: 2014
  end-page: 14
  ident: bib40
  article-title: Physiology and its importance for reference intervals
  publication-title: Clin. Biochem. Rev.
– volume: 50
  start-page: 587
  year: 2017
  end-page: 594
  ident: bib60
  article-title: Pre-analytical and analytical aspects affecting clinical reliability of plasma glucose results
  publication-title: Clin. Biochem.
– volume: 151
  start-page: 364
  year: 2019
  end-page: 370
  ident: bib118
  article-title: Establishing evidence-based statistical quality control practices
  publication-title: Am. J. Clin. Pathol.
– volume: 79
  start-page: 96
  year: 2006
  end-page: 113
  ident: bib20
  article-title: The evolution of the normal distribution
  publication-title: Math. Mag.
– volume: 64
  start-page: 285
  year: 2004
  end-page: 292
  ident: bib6
  article-title: Prerequisites for establishing common reference intervals
  publication-title: Scand. J. Clin. Lab. Invest.
– volume: 174
  start-page: 166
  year: 2008
  end-page: 172
  ident: bib50
  article-title: From population- to subject-based limits of T/E ratio to detect testosterone abuse in elite sports
  publication-title: Forensic Sci. Int.
– volume: 39
  start-page: 1514
  year: 1993
  end-page: 1518
  ident: bib75
  article-title: Tolerance limits for short-term analytical bias and analytical imprecision derived from clinical assay specificity
  publication-title: Clin. Chjemistry.
– volume: 60
  start-page: 1463
  year: 2014
  end-page: 1465
  ident: bib68
  article-title: Performance requirements for glucose assays in intensive care units
  publication-title: Clin. Chem.
– year: 1991
  ident: bib108
  article-title: A Comparison of Analytical Goals for Haemoglobin A1, Assays Derived Using Different Strategies
– volume: 52
  start-page: 973
  year: 2014
  end-page: 980
  ident: bib124
  article-title: Sigma metrics used to assess analytical quality of clinical chemistry assays: importance of the allowable total error (TEa) target
  publication-title: Clin. Chem. Lab. Med.
– volume: 71
  start-page: 624
  year: 1979
  end-page: 630
  ident: bib83
  article-title: Analytical goals in clinical chemistry: their relationship to medical care
  publication-title: Am. J. Clin. Pathol.
– volume: 53
  start-page: 32
  year: 2016
  end-page: 50
  ident: bib121
  article-title: Quality control review: implementing a scientifically based quality control system
  publication-title: Ann. Clin. Biochem.
– volume: 83
  start-page: 200
  year: 1985
  end-page: 205
  ident: bib109
  article-title: Medical useful criteria for analyte performance of laboratory tests
  publication-title: Am. J. Clin. Pathol.
– volume: 55
  start-page: 1849
  year: 2017
  end-page: 1856
  ident: bib55
  article-title: Strategies to define performance specifications in laboratory medicine: 3 years on from the Milan Strategic Conference
  publication-title: Clin. Chem. Lab. Med.
– volume: 63
  start-page: 585
  year: 2017
  end-page: 592
  ident: bib64
  article-title: Simulation models of misclassification error for single thresholds of high-sensitivity cardiac troponin I due to assay bias and imprecision
  publication-title: Clin. Chem.
– year: 1982
  ident: bib103
  article-title: New Concept for Quality Control of Clinical Laboratory Investigations A New Concept for Quality Control of Clinical Laboratory Investigations in the Light of Clinical Requirements and Based on Reference Method Values
– volume: 8
  start-page: 285
  year: 2007
  ident: 10.1016/j.plabm.2020.e00199_bib45
  article-title: Bayesian detection of abnormal values in longitudinal biomarkers with an application to T/E ratio
  publication-title: Biostatistics
  doi: 10.1093/biostatistics/kxl009
– volume: 7
  start-page: 488
  year: 2002
  ident: 10.1016/j.plabm.2020.e00199_bib2
  article-title: Importance of the choice of assumptions and models in the estimation of analytical quality specifications
  publication-title: Accred Qual. Assur.
  doi: 10.1007/s00769-002-0523-6
– year: 1995
  ident: 10.1016/j.plabm.2020.e00199_bib98
– volume: 112
  start-page: 416
  year: 1988
  ident: 10.1016/j.plabm.2020.e00199_bib113
  article-title: Proposed goals for analytical precision and accuracy in single-point diagnostic testing. Theoretical basis and comparison with data from the College of American Pathologists proficiency surveys
  publication-title: Arch. Pathol. Lab Med.
– year: 2013
  ident: 10.1016/j.plabm.2020.e00199_bib145
  article-title: Long-term stability of laboratory tests and practical implications for quality management
  publication-title: Clin. Chem. Lab. Med.
  doi: 10.1515/cclm-2012-0820
– volume: 64
  start-page: 289
  year: 2018
  ident: 10.1016/j.plabm.2020.e00199_bib120
  article-title: Planning risk-based SQC schedules for bracketed operation of continuous production analyzers
  publication-title: Clin. Chem.
  doi: 10.1373/clinchem.2017.278291
– volume: 57
  year: 2019
  ident: 10.1016/j.plabm.2020.e00199_bib139
  article-title: Moving average quality control: principles, practical application and future perspectives
  publication-title: Clin. Chem. Lab. Med.
  doi: 10.1515/cclm-2018-0795
– start-page: 90
  year: 2008
  ident: 10.1016/j.plabm.2020.e00199_bib1
  article-title: International vocabulary of metrology - basic and general concepts and associated terms (VIM)
  publication-title: Bipm
– volume: vol. 1
  year: 1992
  ident: 10.1016/j.plabm.2020.e00199_bib5
– volume: 57
  start-page: 830
  year: 2011
  ident: 10.1016/j.plabm.2020.e00199_bib46
  article-title: The athlete biological passport: an effective tool in the fight against doping
  publication-title: Clin. Chem.
  doi: 10.1373/clinchem.2011.162107
– volume: 53
  start-page: 837
  year: 2015
  ident: 10.1016/j.plabm.2020.e00199_bib88
  article-title: The 1999 Stockholm Consensus Conference on quality specifications in laboratory medicine
  publication-title: Clin. Chem. Lab. Med.
  doi: 10.1515/cclm-2014-0914
– volume: 72
  start-page: 374
  year: 1979
  ident: 10.1016/j.plabm.2020.e00199_bib85
  article-title: Statistical principles underlying analytic goal-setting in clinical chemistry
  publication-title: Am. J. Clin. Pathol.
– year: 2012
  ident: 10.1016/j.plabm.2020.e00199_bib87
– volume: 260
  start-page: 163
  year: 1997
  ident: 10.1016/j.plabm.2020.e00199_bib131
  article-title: Clinical laboratory quality control: a costly process now out of control
  publication-title: Clin. Chim. Acta
  doi: 10.1016/S0009-8981(96)06494-7
– volume: 30
  start-page: 311
  year: 1992
  ident: 10.1016/j.plabm.2020.e00199_bib104
  article-title: Proposed quality specifications for the imprecision and inaccuracy of analytical systems for clinical chemistry
  publication-title: Eur. J. Clin. Chem. Clin. Biochem.
– volume: 48
  start-page: 757
  year: 1988
  ident: 10.1016/j.plabm.2020.e00199_bib101
  article-title: Analytical goals for the acceptance of common reference intervals for laboratories throughout a geographical area
  publication-title: Scand. J. Clin. Lab. Invest.
  doi: 10.3109/00365518809088757
– volume: 52
  start-page: 65
  year: 1992
  ident: 10.1016/j.plabm.2020.e00199_bib105
  article-title: Influence of analytical quality on test results
  publication-title: Scand. J. Clin. Lab. Invest.
  doi: 10.1080/00365519209104641
– volume: 29
  start-page: 142
  year: 2019
  ident: 10.1016/j.plabm.2020.e00199_bib126
  article-title: Sigma metric revisited: true known mistakes
  publication-title: Biochem. Med.
  doi: 10.11613/BM.2019.010902
– ident: 10.1016/j.plabm.2020.e00199_bib78
– volume: 52
  start-page: 973
  year: 2014
  ident: 10.1016/j.plabm.2020.e00199_bib124
  article-title: Sigma metrics used to assess analytical quality of clinical chemistry assays: importance of the allowable total error (TEa) target
  publication-title: Clin. Chem. Lab. Med.
  doi: 10.1515/cclm-2013-1090
– volume: 35
  start-page: 3
  year: 2014
  ident: 10.1016/j.plabm.2020.e00199_bib40
  article-title: Physiology and its importance for reference intervals
  publication-title: Clin. Biochem. Rev.
– volume: 10
  start-page: 294
  year: 2018
  ident: 10.1016/j.plabm.2020.e00199_bib48
  article-title: A step towards removing plasma volume variance from the Athlete’s Biological Passport: the use of biomarkers to describe vascular volumes from a simple blood test
  publication-title: Drug Test. Anal.
  doi: 10.1002/dta.2219
– volume: 30
  start-page: 316
  year: 2018
  ident: 10.1016/j.plabm.2020.e00199_bib26
  article-title: Proficiency Testing: we all do it - but what do the results mean?
  publication-title: Lab. Med.
  doi: 10.1093/labmed/30.5.316
– volume: 53
  start-page: 1197
  year: 2015
  ident: 10.1016/j.plabm.2020.e00199_bib144
  article-title: On-line flagging monitoring - a new quality management tool for the analytical phase
  publication-title: Clin. Chem. Lab. Med.
– volume: 64
  start-page: 285
  year: 2004
  ident: 10.1016/j.plabm.2020.e00199_bib6
  article-title: Prerequisites for establishing common reference intervals
  publication-title: Scand. J. Clin. Lab. Invest.
  doi: 10.1080/00365510410006298
– volume: 64
  start-page: 1006
  year: 2018
  ident: 10.1016/j.plabm.2020.e00199_bib63
  article-title: Quantifying atherogenic lipoproteins: current and future challenges in the era of personalized medicine and very low concentrations of ldl cholesterol. a consensus statement from EAS and EFLM
  publication-title: Clin. Chem.
  doi: 10.1373/clinchem.2018.287037
– start-page: 1
  year: 2013
  ident: 10.1016/j.plabm.2020.e00199_bib74
  article-title: Total analytic error; from concept to application
  publication-title: Clin. Lab. News.
– volume: 19
  start-page: 250
  year: 2009
  ident: 10.1016/j.plabm.2020.e00199_bib15
  article-title: Application of biological variation – a review
  publication-title: Biochem. Med.
  doi: 10.11613/BM.2009.023
– volume: 57
  start-page: 12
  year: 2018
  ident: 10.1016/j.plabm.2020.e00199_bib128
  article-title: Performance specifications and six sigma theory: clinical chemistry and industry compared
  publication-title: Clin. Biochem.
  doi: 10.1016/j.clinbiochem.2018.04.002
– volume: 165
  start-page: 111
  year: 1987
  ident: 10.1016/j.plabm.2020.e00199_bib102
  article-title: The concept of reference intervals
  publication-title: Clin. Chim. Acta
  doi: 10.1016/0009-8981(87)90224-5
– year: 2015
  ident: 10.1016/j.plabm.2020.e00199_bib130
– volume: 42
  start-page: 289
  year: 2018
  ident: 10.1016/j.plabm.2020.e00199_bib143
  article-title: Percentiler and Flagger-low-cost, on-line monitoring of laboratory and manufacturer data and significant surplus to current external quality assessment
  publication-title: J. Lab. Med.
– volume: 20
  start-page: 17
  year: 2020
  ident: 10.1016/j.plabm.2020.e00199_bib53
  article-title: Real-time, personalized medicine through wearable sensors and dynamic predictive modeling: a new paradigm for clinical medicine
  publication-title: Curr. Opin. Struct. Biol.
– volume: 58
  year: 2011
  ident: 10.1016/j.plabm.2020.e00199_bib70
  article-title: Doctor OF medical science Danish medical bulletin
  publication-title: Dan. Med. Bull.
– volume: 36
  start-page: 1625
  year: 1990
  ident: 10.1016/j.plabm.2020.e00199_bib79
  article-title: Setting analytical goals for random analytical situations
  publication-title: Clin. Chem.
  doi: 10.1093/clinchem/36.9.1625
– volume: 9
  start-page: 217
  year: 1963
  ident: 10.1016/j.plabm.2020.e00199_bib89
  article-title: A study of the accuracy and precision of clinical chemistry determinations in 170 Canadian laboratories
  publication-title: Clin. Chem.
  doi: 10.1093/clinchem/9.2.217
– volume: 47
  start-page: 1547
  year: 2001
  ident: 10.1016/j.plabm.2020.e00199_bib69
  article-title: Laboratory related outcomes in healthcare
  publication-title: Clin. Chem.
  doi: 10.1093/clinchem/47.8.1547
– ident: 10.1016/j.plabm.2020.e00199_bib72
– volume: 71
  start-page: 624
  year: 1979
  ident: 10.1016/j.plabm.2020.e00199_bib83
  article-title: Analytical goals in clinical chemistry: their relationship to medical care
  publication-title: Am. J. Clin. Pathol.
  doi: 10.1093/ajcp/71.6.624
– volume: 9
  start-page: 128
  year: 2004
  ident: 10.1016/j.plabm.2020.e00199_bib33
  article-title: etal, Integration of data derived from biological variation into the quality management system
  publication-title: Accred Qual. Assur.
  doi: 10.1007/s00769-003-0727-4
– volume: 57
  start-page: 215
  year: 2020
  ident: 10.1016/j.plabm.2020.e00199_bib97
  article-title: An approach to optimize delta checks in test panels – the effect of the number of rules included
  publication-title: Ann. Clin. Biochem.
  doi: 10.1177/0004563220904749
– volume: 65
  year: 2019
  ident: 10.1016/j.plabm.2020.e00199_bib134
  article-title: Patient-based real-time quality control: review and recommendations
  publication-title: Clin. Chem.
  doi: 10.1373/clinchem.2019.305482
– volume: 50
  start-page: 1136
  year: 2017
  ident: 10.1016/j.plabm.2020.e00199_bib77
  article-title: Assay stability, the missing component of the error budget
  publication-title: Clin. Biochem.
  doi: 10.1016/j.clinbiochem.2017.07.004
– volume: 45
  start-page: 321
  year: 1999
  ident: 10.1016/j.plabm.2020.e00199_bib82
  article-title: Analytical performance characteristics should Be judged against objective quality specifications
  publication-title: Clin. Chem.
  doi: 10.1093/clinchem/45.3.321
– start-page: 19
  year: 2004
  ident: 10.1016/j.plabm.2020.e00199_bib10
  article-title: Test result variation and the quality of evidence-based clinical guidelines
  publication-title: Clin. Chim. Acta
  doi: 10.1016/j.cccn.2003.12.032
– volume: 26
  year: 1969
  ident: 10.1016/j.plabm.2020.e00199_bib27
  article-title: Saris NE, establishment and use of normal values
  publication-title: Establ. Use Norm. Values.
– volume: 53
  start-page: 8
  year: 1993
  ident: 10.1016/j.plabm.2020.e00199_bib106
  article-title: Quality goals in external quality assessment are best based on biology
  publication-title: Scand. J. Clin. Lab. Invest.
  doi: 10.1080/00365519309085446
– volume: 19
  start-page: 175
  year: 2004
  ident: 10.1016/j.plabm.2020.e00199_bib43
  article-title: Bayesian statistics and the efficiency and ethics of clinical trials
  publication-title: Stat. Sci.
  doi: 10.1214/088342304000000044
– ident: 10.1016/j.plabm.2020.e00199_bib18
– volume: 83
  start-page: 200
  year: 1985
  ident: 10.1016/j.plabm.2020.e00199_bib109
  article-title: Medical useful criteria for analyte performance of laboratory tests
  publication-title: Am. J. Clin. Pathol.
  doi: 10.1093/ajcp/83.2.200
– volume: 12
  year: 2012
  ident: 10.1016/j.plabm.2020.e00199_bib67
  article-title: Using patient management as a surrogate for patient health outcomes in diagnostic test evaluation
  publication-title: BMC Med. Res. Methodol.
  doi: 10.1186/1471-2288-12-12
– volume: 38
  start-page: 545
  year: 2000
  ident: 10.1016/j.plabm.2020.e00199_bib13
  article-title: A model for setting analytical quality specifications and design of control for measurements on the ordinal scale
  publication-title: Clin. Chem. Lab. Med.
  doi: 10.1515/CCLM.2000.080
– year: 1991
  ident: 10.1016/j.plabm.2020.e00199_bib80
– volume: 63
  start-page: 585
  year: 2017
  ident: 10.1016/j.plabm.2020.e00199_bib64
  article-title: Simulation models of misclassification error for single thresholds of high-sensitivity cardiac troponin I due to assay bias and imprecision
  publication-title: Clin. Chem.
  doi: 10.1373/clinchem.2016.265058
– volume: 2
  year: 2017
  ident: 10.1016/j.plabm.2020.e00199_bib14
  article-title: Biological variation: a rapidly evolving aspect of laboratory medicine
  publication-title: J. Lab. Precis. Med.
– volume: 50
  start-page: 671
  year: 1968
  ident: 10.1016/j.plabm.2020.e00199_bib90
  article-title: Medical significance of laboratory values
  publication-title: Am. J. Clin. Pathol.
  doi: 10.1093/ajcp/50.6.671
– volume: 432
  start-page: 90
  year: 2014
  ident: 10.1016/j.plabm.2020.e00199_bib9
  article-title: A category 1 EQA scheme for comparison of laboratory performance and method performance: an international pilot study in the framework of the Calibration 2000 project
  publication-title: Clin. Chim. Acta
  doi: 10.1016/j.cca.2013.11.003
– volume: 55
  start-page: 1702
  year: 2017
  ident: 10.1016/j.plabm.2020.e00199_bib122
  article-title: Selecting multi-rule quality control procedures based on patient risk
  publication-title: Clin. Chem. Lab. Med.
  doi: 10.1515/cclm-2016-1077
– year: 2020
  ident: 10.1016/j.plabm.2020.e00199_bib135
  article-title: Implementation of patient-based real-time quality control
  publication-title: Crit. Rev. Clin. Lab Sci.
  doi: 10.1080/10408363.2020.1765731
– volume: 56
  start-page: 75
  year: 2019
  ident: 10.1016/j.plabm.2020.e00199_bib93
  article-title: Delta Checks in the clinical laboratory
  publication-title: Crit. Rev. Clin. Lab Sci.
  doi: 10.1080/10408363.2018.1540536
– year: 2018
  ident: 10.1016/j.plabm.2020.e00199_bib17
– start-page: 925
  year: 2015
  ident: 10.1016/j.plabm.2020.e00199_bib112
  article-title: Proposal for the modification of the conventional model for establishing performance specifications
– volume: 151
  start-page: 364
  year: 2019
  ident: 10.1016/j.plabm.2020.e00199_bib118
  article-title: Establishing evidence-based statistical quality control practices
  publication-title: Am. J. Clin. Pathol.
  doi: 10.1093/ajcp/aqy158
– volume: 57
  start-page: 969
  year: 2011
  ident: 10.1016/j.plabm.2020.e00199_bib44
  article-title: The athlete biological passport
  publication-title: Clin. Chem.
  doi: 10.1373/clinchem.2011.162271
– volume: 53
  start-page: 299
  year: 2015
  ident: 10.1016/j.plabm.2020.e00199_bib30
  article-title: Biological variation database: structure and criteria used for generation and update
  publication-title: Clin. Chem. Lab. Med.
  doi: 10.1515/cclm-2014-0739
– volume: 48
  start-page: 508
  year: 2015
  ident: 10.1016/j.plabm.2020.e00199_bib133
  article-title: Changing the paradigm of laboratory quality control through implementation of real-time test results monitoring:
  publication-title: Clin. Biochem.
  doi: 10.1016/j.clinbiochem.2014.12.016
– volume: 23
  start-page: 47
  year: 2008
  ident: 10.1016/j.plabm.2020.e00199_bib22
  article-title: Adolphe Quetelet (1796-1874) - the average man and indices of obesity
  publication-title: Nephrol. Dial. Transplant.
  doi: 10.1093/ndt/gfm517
– volume: 15
  start-page: 323
  year: 2010
  ident: 10.1016/j.plabm.2020.e00199_bib3
  article-title: Strategies to set global analytical quality specifications in laboratory medicine: 10 years on from the Stockholm consensus conference
  publication-title: Accred Qual. Assur.
  doi: 10.1007/s00769-009-0630-8
– volume: 50
  start-page: 587
  year: 2017
  ident: 10.1016/j.plabm.2020.e00199_bib60
  article-title: Pre-analytical and analytical aspects affecting clinical reliability of plasma glucose results
  publication-title: Clin. Biochem.
  doi: 10.1016/j.clinbiochem.2017.03.009
– start-page: 841
  year: 2015
  ident: 10.1016/j.plabm.2020.e00199_bib71
  article-title: Setting analytical performance specifications based on outcome studies - is it possible?
– year: 1991
  ident: 10.1016/j.plabm.2020.e00199_bib108
– volume: 14
  start-page: 547
  year: 2009
  ident: 10.1016/j.plabm.2020.e00199_bib127
  article-title: Towards standardization of external quality assessment schemes by using bias values based on biological variation
  publication-title: Accred Qual. Assur.
  doi: 10.1007/s00769-009-0549-0
– volume: vol. 35
  year: 2010
  ident: 10.1016/j.plabm.2020.e00199_bib38
– volume: 44
  start-page: 343
  year: 2007
  ident: 10.1016/j.plabm.2020.e00199_bib32
  article-title: Within-subject biological variation in disease: collated data and clinical consequences
  publication-title: Ann. Clin. Biochem.
  doi: 10.1258/000456307780945633
– volume: 94
  start-page: 613
  year: 2018
  ident: 10.1016/j.plabm.2020.e00199_bib25
  article-title: The normal range: it is not normal and it is not a range
  publication-title: Postgrad. Med.
  doi: 10.1136/postgradmedj-2018-135983
– volume: 79
  start-page: 96
  year: 2006
  ident: 10.1016/j.plabm.2020.e00199_bib20
  article-title: The evolution of the normal distribution
  publication-title: Math. Mag.
  doi: 10.1080/0025570X.2006.11953386
– volume: 55
  start-page: 1849
  year: 2017
  ident: 10.1016/j.plabm.2020.e00199_bib55
  article-title: Strategies to define performance specifications in laboratory medicine: 3 years on from the Milan Strategic Conference
  publication-title: Clin. Chem. Lab. Med.
  doi: 10.1515/cclm-2017-0772
– volume: 39
  start-page: 231
  year: 2002
  ident: 10.1016/j.plabm.2020.e00199_bib65
  article-title: Decision limit for troponin I and assay performance
  publication-title: Ann. Clin. Biochem.
  doi: 10.1258/0004563021902161
– volume: 28
  year: 2018
  ident: 10.1016/j.plabm.2020.e00199_bib125
  article-title: Sigma metrics in laboratory medicine revisited: we are on the right road with the wrong map
  publication-title: Biochem. Med.
  doi: 10.11613/BM.2018.020503
– volume: 53
  start-page: 32
  year: 2016
  ident: 10.1016/j.plabm.2020.e00199_bib121
  article-title: Quality control review: implementing a scientifically based quality control system
  publication-title: Ann. Clin. Biochem.
  doi: 10.1177/0004563215597248
– year: 2017
  ident: 10.1016/j.plabm.2020.e00199_bib140
  article-title: Moving standard deviation and moving sum of outliers as quality tools for monitoring analytical precision
  publication-title: Clin. Biochem.
– volume: 48
  start-page: 41
  year: 2010
  ident: 10.1016/j.plabm.2020.e00199_bib4
  article-title: Collective opinion paper on findings of the 2009 convocation of experts on quality control
  publication-title: Clin. Chem. Lab. Med.
  doi: 10.1515/CCLM.2010.001
– volume: 2
  year: 2006
  ident: 10.1016/j.plabm.2020.e00199_bib49
  article-title: Statistical classification of abnormal blood profiles in athletes
  publication-title: Int. J. Biostat.
  doi: 10.2202/1557-4679.1011
– year: 1956
  ident: 10.1016/j.plabm.2020.e00199_bib29
– volume: 57
  start-page: 1329
  year: 2019
  ident: 10.1016/j.plabm.2020.e00199_bib129
  article-title: Design and implementation of quality control plans that integrate moving average and internal quality control: incorporating the best of both worlds
  publication-title: Clin. Chem. Lab. Med.
  doi: 10.1515/cclm-2019-0027
– year: 2020
  ident: 10.1016/j.plabm.2020.e00199_bib42
– start-page: 833
  year: 2015
  ident: 10.1016/j.plabm.2020.e00199_bib56
  article-title: Defining analytical performance specifications: consensus statement from the 1st strategic conference of the European Federation of clinical chemistry and laboratory medicine
– volume: 66
  start-page: 1140
  year: 2020
  ident: 10.1016/j.plabm.2020.e00199_bib138
  article-title: Patient-based real time QC
  publication-title: Clin. Chem.
  doi: 10.1093/clinchem/hvaa149
– volume: 48
  start-page: 817
  year: 2014
  ident: 10.1016/j.plabm.2020.e00199_bib52
  article-title: The athlete biological passport: an integral element of innovative strategies in antidoping
  publication-title: Br. J. Sports Med.
  doi: 10.1136/bjsports-2014-093560
– volume: 49
  start-page: 793
  year: 2011
  ident: 10.1016/j.plabm.2020.e00199_bib111
  article-title: Collective opinion paper on findings of the 2010 convocation of experts on laboratory quality
  publication-title: Clin. Chem. Lab. Med.
  doi: 10.1515/CCLM.2011.149
– volume: 42
  start-page: 692
  year: 2004
  ident: 10.1016/j.plabm.2020.e00199_bib28
  article-title: The evolution of the reference value concept
  publication-title: Clin. Chem. Lab. Med.
  doi: 10.1515/CCLM.2004.118
– volume: 59
  start-page: 509
  year: 1999
  ident: 10.1016/j.plabm.2020.e00199_bib91
  article-title: Analytical bias specifications based on the analysis of effects on performance of medical guidelines
  publication-title: Scand. J. Clin. Lab. Invest.
  doi: 10.1080/00365519950185247
– year: 2012
  ident: 10.1016/j.plabm.2020.e00199_bib86
– volume: 48
  start-page: 827
  year: 2014
  ident: 10.1016/j.plabm.2020.e00199_bib51
  article-title: Monitoring of biological markers indicative of doping: the athlete biological passport
  publication-title: Br. J. Sports Med.
  doi: 10.1136/bjsports-2014-093512
– volume: 59
  start-page: 517
  year: 1999
  ident: 10.1016/j.plabm.2020.e00199_bib12
  article-title: Quality specifications based on the analysis of effects of performance on clinical decision-making
  publication-title: Scand. J. Clin. Lab. Invest.
  doi: 10.1080/00365519950185265
– volume: 7
  year: 2017
  ident: 10.1016/j.plabm.2020.e00199_bib61
  article-title: Impact of analytical and biological variations on classification of diabetes using fasting plasma glucose, oral glucose tolerance test and HbA1c
  publication-title: Sci. Rep.
  doi: 10.1038/s41598-017-14172-8
– volume: 148
  start-page: 323
  year: 2017
  ident: 10.1016/j.plabm.2020.e00199_bib94
  article-title: Utility of reference change values for delta check limits
  publication-title: Am. J. Clin. Pathol.
  doi: 10.1093/ajcp/aqx083
– volume: 32
  start-page: 345
  year: 2012
  ident: 10.1016/j.plabm.2020.e00199_bib96
  article-title: New decision criteria for selecting delta check methods based on the ratio of the delta difference to the width of the reference range can be generally applicable for each clinical chemistry test item
  publication-title: Ann. Lab. Med.
  doi: 10.3343/alm.2012.32.5.345
– volume: 54
  start-page: 223
  year: 2016
  ident: 10.1016/j.plabm.2020.e00199_bib117
  article-title: Useful measures and models for analytical quality management in medical laboratories
  publication-title: Clin. Chem. Lab. Med.
  doi: 10.1515/cclm-2015-0710
– year: 1892
  ident: 10.1016/j.plabm.2020.e00199_bib23
– volume: 56
  start-page: 1091
  year: 2010
  ident: 10.1016/j.plabm.2020.e00199_bib62
  article-title: Glucose meter performance criteria for tight gycemic control estimated by simulation modeling
  publication-title: Clin. Chem.
  doi: 10.1373/clinchem.2010.145367
– volume: 10
  start-page: 377
  year: 1996
  ident: 10.1016/j.plabm.2020.e00199_bib73
  article-title: Error budgets for quality management: practical tools for planning and assuring the analytical quality of testing processes
  publication-title: Clin. Lab. Manag. Rev. Offic. Publ.
– volume: 240
  start-page: 51
  year: 2005
  ident: 10.1016/j.plabm.2020.e00199_bib59
  article-title: Consequences of bias and imprecision in measurements of glucose and hba1c for the diagnosis and prognosis of diabetes mellitus
  publication-title: Scand. J. Clin. Lab. Investig. Suppl.
  doi: 10.1080/00365510500236135
– year: 2004
  ident: 10.1016/j.plabm.2020.e00199_bib7
– volume: 27
  start-page: 409
  year: 1989
  ident: 10.1016/j.plabm.2020.e00199_bib35
  article-title: Generation and application of data on biological variation in clinical chemistry
  publication-title: Crit. Rev. Clin. Lab Sci.
  doi: 10.3109/10408368909106595
– year: 2004
  ident: 10.1016/j.plabm.2020.e00199_bib8
– volume: 427
  start-page: 49
  year: 2014
  ident: 10.1016/j.plabm.2020.e00199_bib58
  article-title: From biomarkers to medical tests: the changing landscape of test evaluation
  publication-title: Clin. Chim. Acta
  doi: 10.1016/j.cca.2013.09.018
– volume: 9
  start-page: 333
  year: 1966
  ident: 10.1016/j.plabm.2020.e00199_bib24
  article-title: A scientific viewpoint on normalcy
  publication-title: Perspect. Biol. Med.
  doi: 10.1353/pbm.1966.0011
– volume: 62
  start-page: 725
  year: 2016
  ident: 10.1016/j.plabm.2020.e00199_bib36
  article-title: Biological variation: the effect of different distributions on estimated within-person variation and reference change values
  publication-title: Clin. Chem.
  doi: 10.1373/clinchem.2015.252296
– volume: 53
  start-page: 133
  year: 2016
  ident: 10.1016/j.plabm.2020.e00199_bib141
  article-title: Average of delta: a new quality control tool for clinical laboratories
  publication-title: Ann. Clin. Biochem.
  doi: 10.1177/0004563215581400
– year: 2014
  ident: 10.1016/j.plabm.2020.e00199_bib114
– volume: 63
  start-page: 1040
  year: 2017
  ident: 10.1016/j.plabm.2020.e00199_bib137
  article-title: Moving average for continuous quality control: time to move to implementation in daily practice?
  publication-title: Clin. Chem.
  doi: 10.1373/clinchem.2016.269258
– start-page: 871
  year: 2015
  ident: 10.1016/j.plabm.2020.e00199_bib34
  article-title: Reliability of biological variation data available in an online database: need for improvement
– year: 2019
  ident: 10.1016/j.plabm.2020.e00199_bib31
  article-title: Systematic review and meta-analysis of within-subject and between-subject biological variation estimates of 20 haematological parameters
  publication-title: Clin. Chem. Lab. Med.
  doi: 10.1515/cclm-2019-0658
– year: 2008
  ident: 10.1016/j.plabm.2020.e00199_bib115
– ident: 10.1016/j.plabm.2020.e00199_bib92
– year: 2020
  ident: 10.1016/j.plabm.2020.e00199_bib147
  article-title: Harmonising EQA schemes the next frontier: challenging the status quo
  publication-title: Clin. Chem. Lab. Med.
  doi: 10.1515/cclm-2020-0343
– start-page: 169
  year: 2003
  ident: 10.1016/j.plabm.2020.e00199_bib76
  article-title: Error budget calculations in laboratory medicine: linking the concepts of biological variation and allowable medical errors
– ident: 10.1016/j.plabm.2020.e00199_bib19
– year: 1982
  ident: 10.1016/j.plabm.2020.e00199_bib103
– volume: 2020
  start-page: 334
  year: 2020
  ident: 10.1016/j.plabm.2020.e00199_bib41
  publication-title: Computational Science – ICCS
– volume: 9
  start-page: 1
  year: 2019
  ident: 10.1016/j.plabm.2020.e00199_bib54
  article-title: Evolution of wearable devices with real-time disease monitoring for personalized healthcare
  publication-title: Nanomaterials
  doi: 10.3390/nano9060813
– volume: 39
  start-page: 59
  year: 2010
  ident: 10.1016/j.plabm.2020.e00199_bib47
  article-title: Endogenous steroid profiling in the athlete biological passport
  publication-title: Endocrinol Metab. Clin. N. Am.
  doi: 10.1016/j.ecl.2009.11.003
– volume: 60
  start-page: 1463
  year: 2014
  ident: 10.1016/j.plabm.2020.e00199_bib68
  article-title: Performance requirements for glucose assays in intensive care units
  publication-title: Clin. Chem.
  doi: 10.1373/clinchem.2014.231258
– volume: 61
  start-page: 191
  year: 2001
  ident: 10.1016/j.plabm.2020.e00199_bib99
  article-title: Evaluation of systematic and random factors in measurements of fasting plasma glucose as the basis for analytical quality specifications in the diagnosis of diabetes. 3. Impact of the new WHO and ADA recommendations on diagnosis of diabetes mellitus
  publication-title: Scand. J. Clin. Lab. Invest.
  doi: 10.1080/003655101300133630
– year: 2001
  ident: 10.1016/j.plabm.2020.e00199_bib11
– volume: 51
  start-page: 703
  year: 2013
  ident: 10.1016/j.plabm.2020.e00199_bib39
  article-title: Personalized (laboratory) medicine: a bridge to the future
  publication-title: Clin. Chem. Lab. Med.
  doi: 10.1515/cclm-2013-0021
– volume: 12
  start-page: 1535
  year: 1974
  ident: 10.1016/j.plabm.2020.e00199_bib37
  article-title: Effects of intra-and interindividual variation on the appropriate use of normal ranges
  publication-title: Clin. Chem.
  doi: 10.1093/clinchem/20.12.1535
– volume: 34
  start-page: 1379
  year: 1988
  ident: 10.1016/j.plabm.2020.e00199_bib84
  article-title: A review on the methodology for assessing diagnostic tests
  publication-title: Clin. Chem.
  doi: 10.1093/clinchem/34.7.1379
– volume: 432
  start-page: 55
  year: 2014
  ident: 10.1016/j.plabm.2020.e00199_bib146
  article-title: Verification of in vitro medical diagnostics (IVD) metrological traceability: responsibilities and strategies
  publication-title: Clin. Chim. Acta
  doi: 10.1016/j.cca.2013.11.022
– volume: 74
  start-page: 1
  year: 1979
  ident: 10.1016/j.plabm.2020.e00199_bib148
  article-title: Some problems of statistics and everyday life
  publication-title: J. Am. Stat. Assoc.
  doi: 10.1080/01621459.1979.10481600
– volume: 3
  start-page: 5
  year: 2012
  ident: 10.1016/j.plabm.2020.e00199_bib95
  article-title: How useful are delta checks in the 21 st century? A stochastic-dynamic model of specimen mix-up and detection
  publication-title: J. Pathol. Inf.
– volume: 98
  start-page: 349
  year: 1993
  ident: 10.1016/j.plabm.2020.e00199_bib110
  article-title: 6.1.2.4 analytical goals for accuracy and precision of Plasma creatinine determinations evaluated by Reference method measurements
  publication-title: Ups. J. Med. Sci.
  doi: 10.3109/03009739309179331
– volume: 57
  start-page: 773
  year: 2019
  ident: 10.1016/j.plabm.2020.e00199_bib136
  article-title: Moving average quality control: principles, practical application and future perspectives
  publication-title: Clin. Chem. Lab. Med.
  doi: 10.1515/cclm-2018-0795
– ident: 10.1016/j.plabm.2020.e00199_bib123
– year: 2001
  ident: 10.1016/j.plabm.2020.e00199_bib16
– volume: 2
  year: 2017
  ident: 10.1016/j.plabm.2020.e00199_bib142
  article-title: Using next generation electronic medical records for laboratory quality monitoring
  publication-title: J. Lab. Precis. Med.
– volume: 174
  start-page: 166
  year: 2008
  ident: 10.1016/j.plabm.2020.e00199_bib50
  article-title: From population- to subject-based limits of T/E ratio to detect testosterone abuse in elite sports
  publication-title: Forensic Sci. Int.
  doi: 10.1016/j.forsciint.2007.04.001
– year: 2001
  ident: 10.1016/j.plabm.2020.e00199_bib107
– start-page: 1
  year: 2020
  ident: 10.1016/j.plabm.2020.e00199_bib132
  article-title: Past, present, and future of laboratory quality control: patient-based real-time quality control or when getting more quality at less cost is not wishful thinking
  publication-title: J. Precis. Lab. Med.
– volume: 495
  start-page: 129
  year: 2019
  ident: 10.1016/j.plabm.2020.e00199_bib116
  article-title: Bias in analytical chemistry: a review of selected procedures for incorporating uncorrected bias into the expanded uncertainty of analytical measurements and a graphical method for evaluating the concordance of reference and test procedures
  publication-title: Clin. Chim. Acta
  doi: 10.1016/j.cca.2019.03.1633
– volume: 54
  start-page: 1303
  year: 2016
  ident: 10.1016/j.plabm.2020.e00199_bib100
  article-title: Measurement uncertainty for clinical laboratories-A revision of the concept
  publication-title: Clin. Chem. Lab. Med.
– year: 1997
  ident: 10.1016/j.plabm.2020.e00199_bib81
– volume: 32
  start-page: 5
  year: 2012
  ident: 10.1016/j.plabm.2020.e00199_bib119
  article-title: Managing the pre- and post-analytical phases of the total testing process
  publication-title: Ann. Lab. Med.
  doi: 10.3343/alm.2012.32.1.5
– year: 2012
  ident: 10.1016/j.plabm.2020.e00199_bib66
– volume: 144
  start-page: 850
  year: 2006
  ident: 10.1016/j.plabm.2020.e00199_bib57
  article-title: When is measuring sensitivity and specificity sufficient to evaluate a diagnostic test, and when do we need randomized trials?
  publication-title: Ann. Intern. Med.
  doi: 10.7326/0003-4819-144-11-200606060-00011
– volume: 23
  start-page: 762
  year: 2012
  ident: 10.1016/j.plabm.2020.e00199_bib21
  article-title: Adolphe quetelet: statistician and more
  publication-title: Epidemiology
  doi: 10.1097/EDE.0b013e318261c86f
– volume: 39
  start-page: 1514
  year: 1993
  ident: 10.1016/j.plabm.2020.e00199_bib75
  article-title: Tolerance limits for short-term analytical bias and analytical imprecision derived from clinical assay specificity
  publication-title: Clin. Chjemistry.
SSID ssj0001877902
Score 2.350167
SecondaryResourceType review_article
Snippet This Review will describe the increasing importance of the concepts of biological variation to clinical chemists. The idea of comparison to ‘reference’ is...
This Review will describe the increasing importance of the concepts of biological variation to clinical chemists. The idea of comparison to 'reference' is...
SourceID doaj
pubmedcentral
proquest
pubmed
crossref
elsevier
SourceType Open Website
Open Access Repository
Aggregation Database
Index Database
Enrichment Source
Publisher
StartPage e00199
SubjectTerms Analytical goals
Biological passport
Patient based quality assurance
Title Biological variation: Understanding why it is so important?
URI https://dx.doi.org/10.1016/j.plabm.2020.e00199
https://www.ncbi.nlm.nih.gov/pubmed/33490349
https://www.proquest.com/docview/2480740899
https://pubmed.ncbi.nlm.nih.gov/PMC7809190
https://doaj.org/article/f83517691c1b4970b6f74e62133e171e
Volume 23
WOSCitedRecordID wos000609874600005&url=https%3A%2F%2Fcvtisr.summon.serialssolutions.com%2F%23%21%2Fsearch%3Fho%3Df%26include.ft.matches%3Dt%26l%3Dnull%26q%3D
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
journalDatabaseRights – providerCode: PRVAON
  databaseName: DOAJ Directory of Open Access Journals
  customDbUrl:
  eissn: 2352-5517
  dateEnd: 99991231
  omitProxy: false
  ssIdentifier: ssj0001877902
  issn: 2352-5517
  databaseCode: DOA
  dateStart: 20150101
  isFulltext: true
  titleUrlDefault: https://www.doaj.org/
  providerName: Directory of Open Access Journals
– providerCode: PRVHPJ
  databaseName: ROAD: Directory of Open Access Scholarly Resources
  customDbUrl:
  eissn: 2352-5517
  dateEnd: 99991231
  omitProxy: false
  ssIdentifier: ssj0001877902
  issn: 2352-5517
  databaseCode: M~E
  dateStart: 20150101
  isFulltext: true
  titleUrlDefault: https://road.issn.org
  providerName: ISSN International Centre
link http://cvtisr.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwrV1Lb9QwEB5BhRAX1PJMoVWQOBLwK3ZcDghQKy6tOFBpb5btOGoqyFbdtBUXfjtjJ1ltQCoXDskhcZx4Zhx_Y4-_AXhd1ZGz21WF5J4VIoimqLinBUf0XOPhG-lSsgl1clItFvrrRqqvGBM20AMPgnvXIESgSmrqqRNaEScbJYJk6FsFqmiIf19EPRvOVJpdqSKPHkuZ5Ur0trCKiXIoBXddoIjjPnRG3oaIcvRsWErs_bPR6W_0-WcQ5caodLQND0c4mX8cmrEDd0L3CO4fjwvmj-H9kGsyaiK_Rrc46eEgP93c0pLfnP3M2z5vV_lqmbc_EiLv-g9P4PTo8NvnL8WYL6HwJSv7QhFdNY5yRSwvJcJmUouGqIAeXhNIjVBHC0tqZhWtuVQucGKVtM6hCxNCKfhT2OqWXXgOOQ2IG12Q2utS1LK0DqGYt9zyRuCAbjNgk7iMH8nEY06L72aKGjs3ScYmytgMMs7gzfqhi4FL4_bin6Ie1kUjEXa6gOZhRvMw_zKPDOSkRTNiigErYFXt7W9_NencYI-Lyyi2C8urlWFxF76Iy6UZPBtsYP2NnAsdGX8yUDPrmDVifqdrzxKrt6oQummy-z9a_QIesBh7k6aKXsJWf3kV9uCev-7b1eU-3FWLaj91GDwf_zr8DVWYFjc
linkProvider Directory of Open Access Journals
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Biological+variation%3A+Understanding+why+it+is+so+important%3F&rft.jtitle=Practical+laboratory+medicine&rft.au=Badrick%2C+Tony&rft.date=2021-01-01&rft.issn=2352-5517&rft.eissn=2352-5517&rft.volume=23&rft.spage=e00199&rft_id=info:doi/10.1016%2Fj.plabm.2020.e00199&rft.externalDBID=NO_FULL_TEXT
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=2352-5517&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=2352-5517&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=2352-5517&client=summon