Quantifying the flash effect and its dependence on average dose rate in vivo for 6 MeV electron and 6 MV photon beams

•Increasing the average dose rate delays the onset, and reduces the severity, of radiation induced skin toxicity.•Similar FLASH effect following 6 MV photon and 6 MeV electron beam irradiation.•30 Gy/s shows a dose modifying factor (DMF) of ≈1.2–1.25, for both photon and electron beams.•DMF was incr...

Celý popis

Uloženo v:
Podrobná bibliografie
Vydáno v:Clinical and translational radiation oncology Ročník 56; s. 101052
Hlavní autoři: Paillas, Salomé, Taylor, Edward R.J.F., Lövgren, Nathalie, Tullis, Iain D.C., Petersson, Kristoffer
Médium: Journal Article
Jazyk:angličtina
Vydáno: Ireland Elsevier B.V 01.01.2026
Elsevier
Témata:
ISSN:2405-6308, 2405-6308
On-line přístup:Získat plný text
Tagy: Přidat tag
Žádné tagy, Buďte první, kdo vytvoří štítek k tomuto záznamu!
Popis
Shrnutí:•Increasing the average dose rate delays the onset, and reduces the severity, of radiation induced skin toxicity.•Similar FLASH effect following 6 MV photon and 6 MeV electron beam irradiation.•30 Gy/s shows a dose modifying factor (DMF) of ≈1.2–1.25, for both photon and electron beams.•DMF was increased to ≈1.5 for our highest used electron dose rates (≥1,800 Gy/s).•Radiotherapy is mainly delivered with MV photon beams, highlighting its importance as a future clinical modality for FLASH. This study shows that an increase in average dose rate delays the onset, and reduces the severity, of radiation induced skin toxicity in mice following hemi-thorax irradiation. The FLASH sparing effect’s magnitude and dependence on dose rate appear similar following irradiations using 6 MV photon and 6 MeV electron beams.
Bibliografie:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:2405-6308
2405-6308