Sri Lanka Pilot Study to Examine Respiratory Health Effects and Personal PM2.5 Exposures from Cooking Indoors

A pilot study of indoor air pollution produced by biomass cookstoves was conducted in 53 homes in Sri Lanka to assess respiratory conditions associated with stove type (“Anagi” or “Traditional”), kitchen characteristics (e.g., presence of a chimney in the home, indoor cooking area), and concentratio...

Celý popis

Uloženo v:
Podrobná bibliografie
Vydáno v:International Journal of Environmental Research and Public Health Ročník 13; číslo 8; s. 791
Hlavní autoři: Phillips, Michael, Smith, Emily, Mosquin, Paul, Chartier, Ryan, Nandasena, Sumal, Bronstein, Katherine, Elledge, Myles, Thornburg, Vanessa, Thornburg, Jonathan, Brown, Linda
Médium: Journal Article
Jazyk:angličtina
Vydáno: Switzerland MDPI AG 05.08.2016
MDPI
Témata:
ISSN:1660-4601, 1661-7827, 1660-4601
On-line přístup:Získat plný text
Tagy: Přidat tag
Žádné tagy, Buďte první, kdo vytvoří štítek k tomuto záznamu!
Popis
Shrnutí:A pilot study of indoor air pollution produced by biomass cookstoves was conducted in 53 homes in Sri Lanka to assess respiratory conditions associated with stove type (“Anagi” or “Traditional”), kitchen characteristics (e.g., presence of a chimney in the home, indoor cooking area), and concentrations of personal and indoor particulate matter less than 2.5 micrometers in diameter (PM2.5). Each primary cook reported respiratory conditions for herself (cough, phlegm, wheeze, or asthma) and for children (wheeze or asthma) living in her household. For cooks, the presence of at least one respiratory condition was significantly associated with 48-h log-transformed mean personal PM2.5 concentration (PR = 1.35; p < 0.001). The prevalence ratio (PR) was significantly elevated for cooks with one or more respiratory conditions if they cooked without a chimney (PR = 1.51, p = 0.025) and non-significantly elevated if they cooked in a separate but poorly ventilated building (PR = 1.51, p = 0.093). The PRs were significantly elevated for children with wheeze or asthma if a traditional stove was used (PR = 2.08, p = 0.014) or if the cooking area was not partitioned from the rest of the home (PR = 2.46, p = 0.012). For the 13 children for whom the cooking area was not partitioned from the rest of the home, having a respiratory condition was significantly associated with log-transformed indoor PM2.5 concentration (PR = 1.51; p = 0.014).
Bibliografie:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1660-4601
1661-7827
1660-4601
DOI:10.3390/ijerph13080791