Sharif-Human movement instrumentation system (SHARIF-HMIS): Development and validation

•The design and development of a wearable system to measure the movement kinematics.•An extension of proposed adaptive Kalman filter (AKF) approach by Li and Wang.•A comprehensive calibration process and validation test were conducted.•SHARIF HMIS may help to better quantify patients’ activity, whic...

Full description

Saved in:
Bibliographic Details
Published in:Medical engineering & physics Vol. 61; pp. 87 - 94
Main Authors: Esfahani, Mohammad Iman Mokhlespour, Akbari, Ali, Zobeiri, Omid, Rashedi, Ehsan, Parnianpour, Mohamad
Format: Journal Article
Language:English
Published: England Elsevier Ltd 01.11.2018
Subjects:
ISSN:1350-4533, 1873-4030, 1873-4030
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:•The design and development of a wearable system to measure the movement kinematics.•An extension of proposed adaptive Kalman filter (AKF) approach by Li and Wang.•A comprehensive calibration process and validation test were conducted.•SHARIF HMIS may help to better quantify patients’ activity, which can be useful for several applications such as medical rehabilitation and progress evaluation of physical therapy. The interest in wearable systems among the biomedical engineering and clinical community continues to escalate as technical refinements enhance their potential use for both indoor and outdoor applications. For example, an important wearable technology known as a microelectromechanical system (MEMS) is demonstrating promising applications in the area of biomedical engineering. Accordingly, this study was designed to investigate the Sharif-Human Movement Instrumentation System (SHARIF-HMIS), consisting of inertial measurement units (IMUs), stretchable clothing, and a data logger—all of which can be used outside the controlled environment of a laboratory, thus enhancing its overall utility. This system is lightweight, portable, able to be deliver data for almost 10 h, and features a new data-fusion algorithm using the Kalman filter with an adaptive approach. In specific terms, the data from the system's gyroscope, accelerometer, and magnetometer sensors can be combined to estimate total-body orientation; additionally, the noise level of these sensors can be changed to accommodate faster motions as well as magnetic disturbances. These variations can be incorporated within the extended Kalman filter by changing the parameters of the filter adaptively. In specific terms, the system's interface was developed to acquire data from eighteen IMUs located on the body to collect kinematic data associated with human motion. Meanwhile, a validation test involving one subject performing different shoulder motions was designed to compare data captured by SHARIF-HMIS and the VICON motion-capture system. This validation test demonstrated correlation values of >0.9. Results also confirmed that the output accuracy of the new system's sensor was <0.55, 1.5 and 3.5° for roll, pitch, and yaw directions, respectively. In summary, SHARIF-HMIS successfully collected kinematic data for specific human movements, which has promising implications for a range of sporting, biomedical, and healthcare-related applications.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ObjectType-Undefined-3
ISSN:1350-4533
1873-4030
1873-4030
DOI:10.1016/j.medengphy.2018.07.008