The Differentiation in Image Post-processing and 3D Reconstruction During Evaluation of Carotid Plaques From MR and CT Data Sources
Background: Carotid plaque morphology and tissue composition help assess risk stratification of stroke events. Many post-processing image techniques based on CT and MR images have been widely used in related research, such as image segmentation, 3D reconstruction, and computer fluid dynamics. Howeve...
Uloženo v:
| Vydáno v: | Frontiers in physiology Ročník 12; s. 645438 |
|---|---|
| Hlavní autoři: | , , , , , |
| Médium: | Journal Article |
| Jazyk: | angličtina |
| Vydáno: |
Switzerland
Frontiers Media S.A
16.04.2021
|
| Témata: | |
| ISSN: | 1664-042X, 1664-042X |
| On-line přístup: | Získat plný text |
| Tagy: |
Přidat tag
Žádné tagy, Buďte první, kdo vytvoří štítek k tomuto záznamu!
|
| Abstract | Background:
Carotid plaque morphology and tissue composition help assess risk stratification of stroke events. Many post-processing image techniques based on CT and MR images have been widely used in related research, such as image segmentation, 3D reconstruction, and computer fluid dynamics. However, the criteria for the 3D numerical model of carotid plaque established by CT and MR angiographic image data remain open to questioning.
Method:
We accurately duplicated the geometry and simulated it using computer software to make a 3D numerical model. The initial images were obtained by CTA and TOF-MRA. MIMICS (Materialize’s interactive medical image control system) software was used to process the images to generate three-dimensional solid models of blood vessels and plaques. The subsequent output was exported to the ANSYS software to generate finite element simulation results for the further hemodynamic study.
Results:
The 3D models of carotid plaque of TOF-MRA and CTA were simulated by using computer software. CTA has a high-density resolution for carotid plaque, the boundary of the CTA image is obvious, and the main component of which is a calcified tissue. However, the density resolution of TOF-MRA for the carotid plaque and carotid artery was not as good as that of CTA. The results show that there is a large deviation between the TOF-MRA and CTA 3D model of plaque in the carotid artery due to the unclear recognition of plaque boundary during 3D reconstruction, and this can further affect the simulation results of hemodynamics.
Conclusion:
In this study, two-dimensional images and three-dimensional models of carotid plaques obtained by two angiographic techniques were compared. The potential of these two imaging methods in clinical diagnosis and fluid dynamics of carotid plaque was evaluated, and the selectivity of image post-processing analysis to original medical image acquisition was revealed. |
|---|---|
| AbstractList | Background: Carotid plaque morphology and tissue composition help assess risk stratification of stroke events. Many post-processing image techniques based on CT and MR images have been widely used in related research, such as image segmentation, 3D reconstruction, and computer fluid dynamics. However, the criteria for the 3D numerical model of carotid plaque established by CT and MR angiographic image data remain open to questioning. Method: We accurately duplicated the geometry and simulated it using computer software to make a 3D numerical model. The initial images were obtained by CTA and TOF-MRA. MIMICS (Materialize's interactive medical image control system) software was used to process the images to generate three-dimensional solid models of blood vessels and plaques. The subsequent output was exported to the ANSYS software to generate finite element simulation results for the further hemodynamic study. Results: The 3D models of carotid plaque of TOF-MRA and CTA were simulated by using computer software. CTA has a high-density resolution for carotid plaque, the boundary of the CTA image is obvious, and the main component of which is a calcified tissue. However, the density resolution of TOF-MRA for the carotid plaque and carotid artery was not as good as that of CTA. The results show that there is a large deviation between the TOF-MRA and CTA 3D model of plaque in the carotid artery due to the unclear recognition of plaque boundary during 3D reconstruction, and this can further affect the simulation results of hemodynamics. Conclusion: In this study, two-dimensional images and three-dimensional models of carotid plaques obtained by two angiographic techniques were compared. The potential of these two imaging methods in clinical diagnosis and fluid dynamics of carotid plaque was evaluated, and the selectivity of image post-processing analysis to original medical image acquisition was revealed.Background: Carotid plaque morphology and tissue composition help assess risk stratification of stroke events. Many post-processing image techniques based on CT and MR images have been widely used in related research, such as image segmentation, 3D reconstruction, and computer fluid dynamics. However, the criteria for the 3D numerical model of carotid plaque established by CT and MR angiographic image data remain open to questioning. Method: We accurately duplicated the geometry and simulated it using computer software to make a 3D numerical model. The initial images were obtained by CTA and TOF-MRA. MIMICS (Materialize's interactive medical image control system) software was used to process the images to generate three-dimensional solid models of blood vessels and plaques. The subsequent output was exported to the ANSYS software to generate finite element simulation results for the further hemodynamic study. Results: The 3D models of carotid plaque of TOF-MRA and CTA were simulated by using computer software. CTA has a high-density resolution for carotid plaque, the boundary of the CTA image is obvious, and the main component of which is a calcified tissue. However, the density resolution of TOF-MRA for the carotid plaque and carotid artery was not as good as that of CTA. The results show that there is a large deviation between the TOF-MRA and CTA 3D model of plaque in the carotid artery due to the unclear recognition of plaque boundary during 3D reconstruction, and this can further affect the simulation results of hemodynamics. Conclusion: In this study, two-dimensional images and three-dimensional models of carotid plaques obtained by two angiographic techniques were compared. The potential of these two imaging methods in clinical diagnosis and fluid dynamics of carotid plaque was evaluated, and the selectivity of image post-processing analysis to original medical image acquisition was revealed. Background: Carotid plaque morphology and tissue composition help assess risk stratification of stroke events. Many post-processing image techniques based on CT and MR images have been widely used in related research, such as image segmentation, 3D reconstruction, and computer fluid dynamics. However, the criteria for the 3D numerical model of carotid plaque established by CT and MR angiographic image data remain open to questioning. Method: We accurately duplicated the geometry and simulated it using computer software to make a 3D numerical model. The initial images were obtained by CTA and TOF-MRA. MIMICS (Materialize’s interactive medical image control system) software was used to process the images to generate three-dimensional solid models of blood vessels and plaques. The subsequent output was exported to the ANSYS software to generate finite element simulation results for the further hemodynamic study. Results: The 3D models of carotid plaque of TOF-MRA and CTA were simulated by using computer software. CTA has a high-density resolution for carotid plaque, the boundary of the CTA image is obvious, and the main component of which is a calcified tissue. However, the density resolution of TOF-MRA for the carotid plaque and carotid artery was not as good as that of CTA. The results show that there is a large deviation between the TOF-MRA and CTA 3D model of plaque in the carotid artery due to the unclear recognition of plaque boundary during 3D reconstruction, and this can further affect the simulation results of hemodynamics. Conclusion: In this study, two-dimensional images and three-dimensional models of carotid plaques obtained by two angiographic techniques were compared. The potential of these two imaging methods in clinical diagnosis and fluid dynamics of carotid plaque was evaluated, and the selectivity of image post-processing analysis to original medical image acquisition was revealed. Carotid plaque morphology and tissue composition help assess risk stratification of stroke events. Many post-processing image techniques based on CT and MR images have been widely used in related research, such as image segmentation, 3D reconstruction, and computer fluid dynamics. However, the criteria for the 3D numerical model of carotid plaque established by CT and MR angiographic image data remain open to questioning. We accurately duplicated the geometry and simulated it using computer software to make a 3D numerical model. The initial images were obtained by CTA and TOF-MRA. MIMICS (Materialize's interactive medical image control system) software was used to process the images to generate three-dimensional solid models of blood vessels and plaques. The subsequent output was exported to the ANSYS software to generate finite element simulation results for the further hemodynamic study. The 3D models of carotid plaque of TOF-MRA and CTA were simulated by using computer software. CTA has a high-density resolution for carotid plaque, the boundary of the CTA image is obvious, and the main component of which is a calcified tissue. However, the density resolution of TOF-MRA for the carotid plaque and carotid artery was not as good as that of CTA. The results show that there is a large deviation between the TOF-MRA and CTA 3D model of plaque in the carotid artery due to the unclear recognition of plaque boundary during 3D reconstruction, and this can further affect the simulation results of hemodynamics. In this study, two-dimensional images and three-dimensional models of carotid plaques obtained by two angiographic techniques were compared. The potential of these two imaging methods in clinical diagnosis and fluid dynamics of carotid plaque was evaluated, and the selectivity of image post-processing analysis to original medical image acquisition was revealed. Background: Carotid plaque morphology and tissue composition help assess risk stratification of stroke events. Many post-processing image techniques based on CT and MR images have been widely used in related research, such as image segmentation, 3D reconstruction, and computer fluid dynamics. However, the criteria for the 3D numerical model of carotid plaque established by CT and MR angiographic image data remain open to questioning.Method: We accurately duplicated the geometry and simulated it using computer software to make a 3D numerical model. The initial images were obtained by CTA and TOF-MRA. MIMICS (Materialize’s interactive medical image control system) software was used to process the images to generate three-dimensional solid models of blood vessels and plaques. The subsequent output was exported to the ANSYS software to generate finite element simulation results for the further hemodynamic study.Results: The 3D models of carotid plaque of TOF-MRA and CTA were simulated by using computer software. CTA has a high-density resolution for carotid plaque, the boundary of the CTA image is obvious, and the main component of which is a calcified tissue. However, the density resolution of TOF-MRA for the carotid plaque and carotid artery was not as good as that of CTA. The results show that there is a large deviation between the TOF-MRA and CTA 3D model of plaque in the carotid artery due to the unclear recognition of plaque boundary during 3D reconstruction, and this can further affect the simulation results of hemodynamics.Conclusion: In this study, two-dimensional images and three-dimensional models of carotid plaques obtained by two angiographic techniques were compared. The potential of these two imaging methods in clinical diagnosis and fluid dynamics of carotid plaque was evaluated, and the selectivity of image post-processing analysis to original medical image acquisition was revealed. |
| Author | Mu, Changping Yi, Rongqi Li, Kang Deng, Fengbin Gu, Min Yang, Ling |
| AuthorAffiliation | 2 Department of Radiology, Chongqing General Hospital, University of Chinese Academy of Sciences , Chongqing , China 1 North Sichuan Medical College , Nanchong , China |
| AuthorAffiliation_xml | – name: 2 Department of Radiology, Chongqing General Hospital, University of Chinese Academy of Sciences , Chongqing , China – name: 1 North Sichuan Medical College , Nanchong , China |
| Author_xml | – sequence: 1 givenname: Fengbin surname: Deng fullname: Deng, Fengbin – sequence: 2 givenname: Changping surname: Mu fullname: Mu, Changping – sequence: 3 givenname: Ling surname: Yang fullname: Yang, Ling – sequence: 4 givenname: Rongqi surname: Yi fullname: Yi, Rongqi – sequence: 5 givenname: Min surname: Gu fullname: Gu, Min – sequence: 6 givenname: Kang surname: Li fullname: Li, Kang |
| BackLink | https://www.ncbi.nlm.nih.gov/pubmed/33935800$$D View this record in MEDLINE/PubMed |
| BookMark | eNp1kk9r3DAQxUVJadI0H6CXomMv3uqvLV8KZTdpFxIa0i30JrTyeFfBtraSHMi5X7xabxKSQnWR0Lz5PZh5b9HR4AdA6D0lM85V_andbe_jjBFGZ6WQgqtX6ISWpSiIYL-Onr2P0VmMtyQfQRgh9A065rzmUhFygv6stoAXrm0hwJCcSc4P2A142ZsN4GsfU7EL3kKMbthgMzSYL_ANWD_EFEY7yRdj2BfP70w3HgC-xXMTfHINvu7M7xEivgi-x1c3E2K-wguTDP7hx5DR79Dr1nQRzh7uU_Tz4nw1_1Zcfv-6nH-5LKwoZSq4FcAl5axpSWmZBQpVDWAqWCvBssbWlSCWNkwxqKQRtLXVWjUVBdHysuanaHngNt7c6l1wvQn32hunpw8fNtqE5GwHmpAGBFElZaUSsrFKWkYUVKRt1rWoq8z6fGDtxnUPjc3DC6Z7AX1ZGdxWb_ydVkRJLlkGfHwABL8fUNK9ixa6zgzgx6iZZFSSvCiRpR-eez2ZPG4xC6qDwAYfY4BWW5emTWRr12lK9D4yeoqM3kdGHyKTO-k_nY_w__f8BVXjxiE |
| CitedBy_id | crossref_primary_10_1038_s41598_021_93605_x crossref_primary_10_1080_23311916_2023_2178367 crossref_primary_10_1007_s12265_024_10534_6 crossref_primary_10_3390_diagnostics13030519 crossref_primary_10_3389_fneur_2023_1159288 |
| Cites_doi | 10.1371/journal.pone.0123031 10.1016/j.ijcard.2019.07.005 10.1159/000373918 10.1161/01.STR.0000199613.38911.b2 10.1016/j.jvs.2006.04.013 10.3174/ajnr.A3607 10.3174/ajnr.A3132 10.1161/CIR.0b013e31828124ad 10.1186/1475-925X-12-105 10.1007/s00330-008-0962-5 10.1148/radiol.2017170127 10.3174/ajnr.A3028 10.1161/STROKEAHA.108.538439 10.3174/ajnr.A0582 10.1120/jacmp.v13i5.3875 10.3174/ajnr.A2863 10.1161/JAHA.115.002012 10.12659/MSM.902995 10.1016/S0140-6736(12)61728-0 10.1161/STROKEAHA.114.007437 10.5551/jat.47449 10.1016/j.jvs.2018.11.050 10.1007/s10554-016-1055-1 10.1093/neuonc/nov029 |
| ContentType | Journal Article |
| Copyright | Copyright © 2021 Deng, Mu, Yang, Yi, Gu and Li. Copyright © 2021 Deng, Mu, Yang, Yi, Gu and Li. 2021 Deng, Mu, Yang, Yi, Gu and Li |
| Copyright_xml | – notice: Copyright © 2021 Deng, Mu, Yang, Yi, Gu and Li. – notice: Copyright © 2021 Deng, Mu, Yang, Yi, Gu and Li. 2021 Deng, Mu, Yang, Yi, Gu and Li |
| DBID | AAYXX CITATION NPM 7X8 5PM DOA |
| DOI | 10.3389/fphys.2021.645438 |
| DatabaseName | CrossRef PubMed MEDLINE - Academic PubMed Central (Full Participant titles) DOAJ Directory of Open Access Journals |
| DatabaseTitle | CrossRef PubMed MEDLINE - Academic |
| DatabaseTitleList | MEDLINE - Academic CrossRef PubMed |
| Database_xml | – sequence: 1 dbid: DOA name: Directory of Open Access Journals (DOAJ) url: https://www.doaj.org/ sourceTypes: Open Website – sequence: 2 dbid: NPM name: PubMed url: http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed sourceTypes: Index Database – sequence: 3 dbid: 7X8 name: MEDLINE - Academic url: https://search.proquest.com/medline sourceTypes: Aggregation Database |
| DeliveryMethod | fulltext_linktorsrc |
| Discipline | Anatomy & Physiology |
| EISSN | 1664-042X |
| ExternalDocumentID | oai_doaj_org_article_00de4086126845dc85c208e70fdb9497 PMC8085352 33935800 10_3389_fphys_2021_645438 |
| Genre | Journal Article |
| GrantInformation_xml | – fundername: Chongqing Health Joint Medical Research Project grantid: 2019ZDXM008 – fundername: Chongqing Technology Innovation and Application Development Special Project grantid: CSTC2020JSCX-SBW0024 – fundername: Basic Research and Frontier Exploration Project grantid: 20180107 – fundername: Chongqing Municipal People’s Hospital Science and Technology Innovation Project grantid: Y2019ZDXM01 |
| GroupedDBID | 53G 5VS 9T4 AAFWJ AAKDD AAYXX ACGFO ACGFS ADBBV ADRAZ AENEX AFPKN ALMA_UNASSIGNED_HOLDINGS AOIJS BCNDV CITATION DIK EMOBN F5P GROUPED_DOAJ GX1 HYE KQ8 M48 M~E O5R O5S OK1 PGMZT RNS RPM ACXDI IAO IEA IHR IHW IPNFZ ISR NPM RIG 7X8 5PM |
| ID | FETCH-LOGICAL-c465t-3c4e35132df06c2ce1e79eea7eb842c46c9740c1d282e75a41fc7b8d71e4f3693 |
| IEDL.DBID | DOA |
| ISICitedReferencesCount | 5 |
| ISICitedReferencesURI | http://www.webofscience.com/api/gateway?GWVersion=2&SrcApp=Summon&SrcAuth=ProQuest&DestLinkType=CitingArticles&DestApp=WOS_CPL&KeyUT=000645445000001&url=https%3A%2F%2Fcvtisr.summon.serialssolutions.com%2F%23%21%2Fsearch%3Fho%3Df%26include.ft.matches%3Dt%26l%3Dnull%26q%3D |
| ISSN | 1664-042X |
| IngestDate | Fri Oct 03 12:41:46 EDT 2025 Tue Sep 30 16:57:54 EDT 2025 Thu Sep 04 18:39:59 EDT 2025 Thu Jan 02 22:57:16 EST 2025 Tue Nov 18 22:26:26 EST 2025 Sat Nov 29 04:01:51 EST 2025 |
| IsDoiOpenAccess | true |
| IsOpenAccess | true |
| IsPeerReviewed | true |
| IsScholarly | true |
| Keywords | CT angiography computational fluid dynamic carotid plaque fluid-solid interaction MR angiography aneurysms |
| Language | English |
| License | Copyright © 2021 Deng, Mu, Yang, Yi, Gu and Li. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
| LinkModel | DirectLink |
| MergedId | FETCHMERGED-LOGICAL-c465t-3c4e35132df06c2ce1e79eea7eb842c46c9740c1d282e75a41fc7b8d71e4f3693 |
| Notes | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 Edited by: Dalin Tang, Worcester Polytechnic Institute, United States These authors have contributed equally to this work and share first authorship Reviewed by: Jixin Liu, Xidian University, China; Ruolin Du, Chongqing University, China This article was submitted to Computational Physiology and Medicine, a section of the journal Frontiers in Physiology |
| OpenAccessLink | https://doaj.org/article/00de4086126845dc85c208e70fdb9497 |
| PMID | 33935800 |
| PQID | 2521503394 |
| PQPubID | 23479 |
| ParticipantIDs | doaj_primary_oai_doaj_org_article_00de4086126845dc85c208e70fdb9497 pubmedcentral_primary_oai_pubmedcentral_nih_gov_8085352 proquest_miscellaneous_2521503394 pubmed_primary_33935800 crossref_citationtrail_10_3389_fphys_2021_645438 crossref_primary_10_3389_fphys_2021_645438 |
| PublicationCentury | 2000 |
| PublicationDate | 2021-04-16 |
| PublicationDateYYYYMMDD | 2021-04-16 |
| PublicationDate_xml | – month: 04 year: 2021 text: 2021-04-16 day: 16 |
| PublicationDecade | 2020 |
| PublicationPlace | Switzerland |
| PublicationPlace_xml | – name: Switzerland |
| PublicationTitle | Frontiers in physiology |
| PublicationTitleAlternate | Front Physiol |
| PublicationYear | 2021 |
| Publisher | Frontiers Media S.A |
| Publisher_xml | – name: Frontiers Media S.A |
| References | Gupta (ref8); 4 Lu (ref11) 2019; 26 Sheahan (ref16) 2018; 286 Chrencik (ref2) 2019; 70 Jia (ref9) 2017; 23 Lozano (ref10) 2012; 380 Tang (ref18) 2013; 12 Wang (ref21) 2019; 293 Qiao (ref13) 2012; 33 Takaya (ref17) 2006; 43 Go (ref6) 2013; 127 Seshadri (ref15) 2006; 37 Moussallem (ref500) 2012; 13 Eshtehardi (ref4) 2017; 33 Etesami (ref5) 2013; 34 Zhao (ref22) 2007; 28 Saba (ref14) 2008; 18 Stensjøen (ref600) 2015; 17 van’t Klooster (ref20) 2012; 33 Abbott (ref1) 2015; 46 Nieuwstadt (ref12) 2015; 10 Trelles (ref19) 2013; 34 De Weert (ref3) 2009; 40 Gupta (ref7); 39 |
| References_xml | – volume: 10 start-page: e0123031 year: 2015 ident: ref12 article-title: A computer-simulation study on the effects of MRI voxel dimensions on carotid plaque lipid-core and fibrous cap segmentation and stress modeling publication-title: PLoS One doi: 10.1371/journal.pone.0123031 – volume: 293 start-page: 266 year: 2019 ident: ref21 article-title: Combining morphological and biomechanical factors for optimal carotid plaque progression prediction: an MRI-based follow-up study using 3D thin-layer models publication-title: Int. J. Cardiol. doi: 10.1016/j.ijcard.2019.07.005 – volume: 39 start-page: 151 ident: ref7 article-title: Detection of symptomatic carotid plaque using source data from MR and CT angiography: a correlative study publication-title: Cerebrovasc. Dis. doi: 10.1159/000373918 – volume: 37 start-page: 345 year: 2006 ident: ref15 article-title: The lifetime risk of stroke: estimates from the Framingham study publication-title: Stroke doi: 10.1161/01.STR.0000199613.38911.b2 – volume: 43 start-page: 1077 year: 2006 ident: ref17 article-title: Association between carotid plaque characteristics and subsequent ischemic cerebrovascular events: a prospective assessment with MRI—initial results publication-title: J. Vasc. Surg. doi: 10.1016/j.jvs.2006.04.013 – volume: 34 start-page: 2331 year: 2013 ident: ref19 article-title: CTA for screening of complicated atherosclerotic ca rotid plaque—American Heart Association type VI lesions as defined by MRI publication-title: Am. J. Neuroradiol. doi: 10.3174/ajnr.A3607 – volume: 34 start-page: 177 year: 2013 ident: ref5 article-title: Comparison of carotid plaque ulcer detection using contrast-enhanced and time-of-flight MRA techniques publication-title: Am. J. Neuroradiol. doi: 10.3174/ajnr.A3132 – volume: 127 start-page: e6 year: 2013 ident: ref6 article-title: Heart disease and stroke statistics-2013 update: a report from the American Heart Association publication-title: Circulation doi: 10.1161/CIR.0b013e31828124ad – volume: 12 start-page: 105 year: 2013 ident: ref18 article-title: Correlations between carotid plaque progression and mechanical stresses change sign over time: a patient follow up study using MRI and 3D FSI models publication-title: Biomed. Eng. Online doi: 10.1186/1475-925X-12-105 – volume: 18 start-page: 1962 year: 2008 ident: ref14 article-title: Carotid artery wall thickness and ischemic symptoms: evaluation using multi-detector-row CT angiography publication-title: Eur. Radiol. doi: 10.1007/s00330-008-0962-5 – volume: 286 start-page: 622 year: 2018 ident: ref16 article-title: Atherosclerotic plaque tissue: noninvasive quantitative assessment of characteristics with software-aided measurements from conventional CT angiography publication-title: Radiology doi: 10.1148/radiol.2017170127 – volume: 33 start-page: 1621 year: 2012 ident: ref20 article-title: Automated versus manual in vivo segmentation of carotid plaque MRI publication-title: Am. J. Neuroradiol. doi: 10.3174/ajnr.A3028 – volume: 40 start-page: 1334 year: 2009 ident: ref3 article-title: Atherosclerotic plaque surface morphology in the carotid bifurcation assessed with multidetector computed tomography angiography publication-title: Stroke doi: 10.1161/STROKEAHA.108.538439 – volume: 28 start-page: 1470 year: 2007 ident: ref22 article-title: Regional cerebral blood flow using quantitative MR angiography publication-title: Am. J. Neuroradiol. doi: 10.3174/ajnr.A0582 – volume: 13 start-page: 236 year: 2012 ident: ref500 article-title: New strategy for automatic tumor segmentation by adaptive thresholding on PET/CT images publication-title: J. Appl. Clin. Med. Phys. doi: 10.1120/jacmp.v13i5.3875 – volume: 33 start-page: 755 year: 2012 ident: ref13 article-title: Carotid plaque neovascularization and hemorrhage detected by MR imaging are associated with recent cerebrovascular ischemic events publication-title: Am. J. Neuroradiol. doi: 10.3174/ajnr.A2863 – volume: 4 start-page: e002012 ident: ref8 article-title: Magnetic resonance angiography detection of abnormal carotid artery plaque in patients with cryptogenic stroke publication-title: J. Am. Heart Assoc. doi: 10.1161/JAHA.115.002012 – volume: 23 start-page: 479 year: 2017 ident: ref9 article-title: Combination of magnetic resonance angiography and computational fluid dynamics may predict the risk of stroke in patients with asymptomatic carotid plaques publication-title: Med. Sci. Monit. doi: 10.12659/MSM.902995 – volume: 380 start-page: 2095 year: 2012 ident: ref10 article-title: Global and regional mortality from 235 causes of death for 20 age groups in 1990 and 2010: a systematic analysis for the global burden of disease study 2010 publication-title: Lancet doi: 10.1016/S0140-6736(12)61728-0 – volume: 46 start-page: 7 year: 2015 ident: ref1 article-title: Improving outcomes in patients with carotid stenosis: call for better research opportunities and standards publication-title: Stroke doi: 10.1161/STROKEAHA.114.007437 – volume: 26 start-page: 720 year: 2019 ident: ref11 article-title: Shape and location of carotid atherosclerotic plaque and intraplaque hemorrhage: a high-resolution magnetic resonance imaging study publication-title: J. Atheroscler. Thromb. doi: 10.5551/jat.47449 – volume: 70 start-page: 858 year: 2019 ident: ref2 article-title: Quantitative assessment of carotid plaque morphology (geometry and tissue composition) using computed tomography angiography publication-title: J. Vasc. Surg. doi: 10.1016/j.jvs.2018.11.050 – volume: 33 start-page: 1089 year: 2017 ident: ref4 article-title: High wall shear stress and high-risk plaque: an emerging concept publication-title: Int. J. Card. Imaging doi: 10.1007/s10554-016-1055-1 – volume: 17 start-page: 1402 year: 2015 ident: ref600 article-title: Growth dynamics of untreated glioblastomas in vivo publication-title: NeuroOncology doi: 10.1093/neuonc/nov029 |
| SSID | ssj0000402001 |
| Score | 2.290447 |
| Snippet | Background:
Carotid plaque morphology and tissue composition help assess risk stratification of stroke events. Many post-processing image techniques based on... Carotid plaque morphology and tissue composition help assess risk stratification of stroke events. Many post-processing image techniques based on CT and MR... Background: Carotid plaque morphology and tissue composition help assess risk stratification of stroke events. Many post-processing image techniques based on... |
| SourceID | doaj pubmedcentral proquest pubmed crossref |
| SourceType | Open Website Open Access Repository Aggregation Database Index Database Enrichment Source |
| StartPage | 645438 |
| SubjectTerms | aneurysms carotid plaque computational fluid dynamic CT angiography fluid-solid interaction MR angiography Physiology |
| Title | The Differentiation in Image Post-processing and 3D Reconstruction During Evaluation of Carotid Plaques From MR and CT Data Sources |
| URI | https://www.ncbi.nlm.nih.gov/pubmed/33935800 https://www.proquest.com/docview/2521503394 https://pubmed.ncbi.nlm.nih.gov/PMC8085352 https://doaj.org/article/00de4086126845dc85c208e70fdb9497 |
| Volume | 12 |
| WOSCitedRecordID | wos000645445000001&url=https%3A%2F%2Fcvtisr.summon.serialssolutions.com%2F%23%21%2Fsearch%3Fho%3Df%26include.ft.matches%3Dt%26l%3Dnull%26q%3D |
| hasFullText | 1 |
| inHoldings | 1 |
| isFullTextHit | |
| isPrint | |
| journalDatabaseRights | – providerCode: PRVAON databaseName: Directory of Open Access Journals (DOAJ) customDbUrl: eissn: 1664-042X dateEnd: 99991231 omitProxy: false ssIdentifier: ssj0000402001 issn: 1664-042X databaseCode: DOA dateStart: 20100101 isFulltext: true titleUrlDefault: https://www.doaj.org/ providerName: Directory of Open Access Journals – providerCode: PRVHPJ databaseName: ROAD: Directory of Open Access Scholarly Resources customDbUrl: eissn: 1664-042X dateEnd: 99991231 omitProxy: false ssIdentifier: ssj0000402001 issn: 1664-042X databaseCode: M~E dateStart: 20100101 isFulltext: true titleUrlDefault: https://road.issn.org providerName: ISSN International Centre |
| link | http://cvtisr.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwrV1Lb9QwELag4sAFUcojlFaDhDgghTqJE9vHtrsrOLSqoEh7i7x-iJW62aoNSL1w4Y8zY6fbXYTgwiWHxI4tz9iezzP-hrE3pggSrSGfl0EjQHHO5LMmhFwEW0vBlQncxGQT8vRUTaf6bC3VF8WEJXrgNHAHnDuPdXAjbpSonVW1Lbnykgc300LHe-Rc6jUwFddggkW8SG5MRGH6INBJAeLBsnhPJFZ0H2VtI4p8_X8yMn-PlVzbfCaP2aPBaoTD1Nttds93T9jOYYeIeXEDbyHGccYD8h32EyUPoyHvSZ9GHuYdfFzg0gGUnDe_TLcDcNcC0zmoRkAo9I5LFkbx8iKMV1TgsAxAsSH93MHZhaHew-RquYCTT_EXx-cwMr2Bz9EXcP2UfZmMz48_5EOqhdyKpu7zygpf1YhMXeCNLa0vvNTeG-lnSpRYxiLu4LZwiNC8rI0ogpUz5WThRagaXT1jW92y8y8YoH3IudeIrBuP1o5Srna-5E4XQmpUiIzx23Fv7cBDTukwLlrEIySqNoqqJVG1SVQZe7eqcplIOP5W-IiEuSpI_NnxBWpVO2hV-y-tytjrW1Vocb6RE8V0fvkNW0J7h1y_WmTseVKNVVNVpJPjPGNyQ2k2-rL5pZt_jZzeCk1ftIVf_o_O77KHNB7k8yqaV2wLlcfvsQf2ez-_vtpn9-VU7cfpgs-TH-NfmPga4A |
| linkProvider | Directory of Open Access Journals |
| openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=The+Differentiation+in+Image+Post-processing+and+3D+Reconstruction+During+Evaluation+of+Carotid+Plaques+From+MR+and+CT+Data+Sources&rft.jtitle=Frontiers+in+physiology&rft.au=Fengbin+Deng&rft.au=Changping+Mu&rft.au=Ling+Yang&rft.au=Rongqi+Yi&rft.date=2021-04-16&rft.pub=Frontiers+Media+S.A&rft.eissn=1664-042X&rft.volume=12&rft_id=info:doi/10.3389%2Ffphys.2021.645438&rft.externalDBID=DOA&rft.externalDocID=oai_doaj_org_article_00de4086126845dc85c208e70fdb9497 |
| thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1664-042X&client=summon |
| thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1664-042X&client=summon |
| thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1664-042X&client=summon |