Effect of Acetabular Position on Polyethylene Liner Wear Measured Using Simultaneous Biplanar Acquisition

Studies that have previously examined the relationship between acetabular component inclination angle and polyethylene wear have shown increased wear of conventional polyethylene with high inclination angles. To date, there are no long-term in vivo studies examining the correlation between cup posit...

Full description

Saved in:
Bibliographic Details
Published in:The Journal of arthroplasty Vol. 32; no. 5; pp. 1670 - 1674
Main Authors: Goyal, Prateek, Howard, James L., Yuan, Xunhua, Teeter, Matthew G., Lanting, Brent A.
Format: Journal Article
Language:English
Published: United States Elsevier Inc 01.05.2017
Subjects:
ISSN:0883-5403, 1532-8406, 1532-8406
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Studies that have previously examined the relationship between acetabular component inclination angle and polyethylene wear have shown increased wear of conventional polyethylene with high inclination angles. To date, there are no long-term in vivo studies examining the correlation between cup position and polyethylene wear with highly crosslinked polyethylene. An institutional arthroplasty database was used to identify patients who had metal-on-highly crosslinked polyethylene primary total hip arthroplasty using the same component design with a minimum follow-up of 10 years. A modified radiostereometric analysis examination setup was utilized, recreating standard anteroposterior and cross-table lateral examinations in a single stereo radiostereometric analysis acquisition. The same radiographs were used to measure inclination angle and anteversion. A total of 43 hips were included for analysis in this study. Average follow-up was 12.3 ± 1.2 years. The average linear wear rate was calculated to be 0.066 ± 0.066 mm/y. Inclination angle was not correlated with polyethylene wear rate (P = .82). Anteversion was also not correlated with polyethylene wear rate (P = .11). At long-term follow-up of >10 years, highly crosslinked polyethylene has a very low wear rate. This excellent tribology is independent of acetabular position. The low wear rate highlights the excellent results of metal on highly crosslinked polyethylene, and supports its use in total hip arthroplasty.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0883-5403
1532-8406
1532-8406
DOI:10.1016/j.arth.2016.11.057