The Impact of Coronal Plane Alignment on Polyethylene Wear and Damage in Total Knee Arthroplasty: A Retrieval Study

Coronal plane alignment is one of the contributing factors to polyethylene wear in total knee arthroplasty. Based on 95 retrieved polyethylene inserts, wear and damage patterns were analyzed in relationship to the overall mechanical alignment and to the position of the tibial component. A progressio...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Journal of arthroplasty Jg. 32; H. 6; S. 2012 - 2016
Hauptverfasser: Vandekerckhove, Pieter-Jan T.K., Teeter, Matthew G., Naudie, Douglas D.R., Howard, James L., MacDonald, Steven J., Lanting, Brent A.
Format: Journal Article
Sprache:Englisch
Veröffentlicht: United States Elsevier Inc 01.06.2017
Schlagworte:
ISSN:0883-5403, 1532-8406, 1532-8406
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Abstract Coronal plane alignment is one of the contributing factors to polyethylene wear in total knee arthroplasty. Based on 95 retrieved polyethylene inserts, wear and damage patterns were analyzed in relationship to the overall mechanical alignment and to the position of the tibial component. A progression of wear was observed with progressively mechanical varus alignment. However, there was significantly more damage in the lateral compartment in the mild and moderate varus group compared to the valgus group. No difference in damage was seen between all groups for tibial component positioning in valgus or varus. Progressive wear was observed with progressively varus alignment with more damage at the lateral side. This observation is unique and might be explained by lateral condylar lift-off inducing impact and shear loading in the varus group.
AbstractList Coronal plane alignment is one of the contributing factors to polyethylene wear in total knee arthroplasty. Based on 95 retrieved polyethylene inserts, wear and damage patterns were analyzed in relationship to the overall mechanical alignment and to the position of the tibial component. A progression of wear was observed with progressively mechanical varus alignment. However, there was significantly more damage in the lateral compartment in the mild and moderate varus group compared to the valgus group. No difference in damage was seen between all groups for tibial component positioning in valgus or varus. Progressive wear was observed with progressively varus alignment with more damage at the lateral side. This observation is unique and might be explained by lateral condylar lift-off inducing impact and shear loading in the varus group.
Coronal plane alignment is one of the contributing factors to polyethylene wear in total knee arthroplasty.BACKGROUNDCoronal plane alignment is one of the contributing factors to polyethylene wear in total knee arthroplasty.Based on 95 retrieved polyethylene inserts, wear and damage patterns were analyzed in relationship to the overall mechanical alignment and to the position of the tibial component.METHODSBased on 95 retrieved polyethylene inserts, wear and damage patterns were analyzed in relationship to the overall mechanical alignment and to the position of the tibial component.A progression of wear was observed with progressively mechanical varus alignment. However, there was significantly more damage in the lateral compartment in the mild and moderate varus group compared to the valgus group. No difference in damage was seen between all groups for tibial component positioning in valgus or varus.RESULTSA progression of wear was observed with progressively mechanical varus alignment. However, there was significantly more damage in the lateral compartment in the mild and moderate varus group compared to the valgus group. No difference in damage was seen between all groups for tibial component positioning in valgus or varus.Progressive wear was observed with progressively varus alignment with more damage at the lateral side. This observation is unique and might be explained by lateral condylar lift-off inducing impact and shear loading in the varus group.CONCLUSIONProgressive wear was observed with progressively varus alignment with more damage at the lateral side. This observation is unique and might be explained by lateral condylar lift-off inducing impact and shear loading in the varus group.
Abstract Background Coronal plane alignment is one of the contributing factors to polyethylene wear in total knee arthroplasty. Methods Based on 95 retrieved polyethylene inserts, wear and damage patterns were analyzed in relationship to the overall mechanical alignment and to the position of the tibial component. Results A progression of wear was observed with progressively mechanical varus alignment. However, there was significantly more damage in the lateral compartment in the mild and moderate varus group compared to the valgus group. No difference in damage was seen between all groups for tibial component positioning in valgus or varus. Conclusion Progressive wear was observed with progressively varus alignment with more damage at the lateral side. This observation is unique and might be explained by lateral condylar lift-off inducing impact and shear loading in the varus group.
Author Naudie, Douglas D.R.
MacDonald, Steven J.
Teeter, Matthew G.
Lanting, Brent A.
Howard, James L.
Vandekerckhove, Pieter-Jan T.K.
Author_xml – sequence: 1
  givenname: Pieter-Jan T.K.
  orcidid: 0000-0002-0305-5280
  surname: Vandekerckhove
  fullname: Vandekerckhove, Pieter-Jan T.K.
  organization: Department of Orthopaedic Surgery, London Health Sciences Centre, London, Ontario, Canada
– sequence: 2
  givenname: Matthew G.
  surname: Teeter
  fullname: Teeter, Matthew G.
  organization: Department of Orthopaedic Surgery, London Health Sciences Centre, London, Ontario, Canada
– sequence: 3
  givenname: Douglas D.R.
  surname: Naudie
  fullname: Naudie, Douglas D.R.
  organization: Department of Orthopaedic Surgery, London Health Sciences Centre, London, Ontario, Canada
– sequence: 4
  givenname: James L.
  surname: Howard
  fullname: Howard, James L.
  organization: Department of Orthopaedic Surgery, London Health Sciences Centre, London, Ontario, Canada
– sequence: 5
  givenname: Steven J.
  surname: MacDonald
  fullname: MacDonald, Steven J.
  organization: Department of Orthopaedic Surgery, London Health Sciences Centre, London, Ontario, Canada
– sequence: 6
  givenname: Brent A.
  surname: Lanting
  fullname: Lanting, Brent A.
  organization: Department of Orthopaedic Surgery, London Health Sciences Centre, London, Ontario, Canada
BackLink https://www.ncbi.nlm.nih.gov/pubmed/28209278$$D View this record in MEDLINE/PubMed
BookMark eNqFkk9v3CAQxVGVqtmk_QI9VBx7WRewsXFUVVpt_0WN1KjZqkeE8TjLFsMW2Ej-9sXa5BKp6Qmkeb_HMG_O0InzDhB6TUlBCa3f7QoV0rZg-V5QVpBKPEMLyku2FBWpT9CCCFEueUXKU3QW444QSjmvXqBTJhhpWSMWKG62gC_HvdIJ-wGvffBOWXxtlQO8subWjeByyeFrbydI28lCrvwCFbByPf6oRnUL2Di88SmD3xxkLrcV_N6qmKYLvMI_IAUDd7l8kw799BI9H5SN8Or-PEc_P3_arL8ur75_uVyvrpa6qllaVm0Juhs4BU2hK6loKt0qXgroVaN4LbhgQFtO2aC6um_bgeqBN5RXipAOdHmO3h5998H_OUBMcjRRg53_5g9RUlG3bd2wss3SN_fSQzdCL_fBjCpM8mFQWSCOAh18jAEGqU1SyXiXgjJWUiLnTOROzpnIORNJmcyZZJQ9Qh_cn4TeHyHIA7ozEGTUBpyG3gTQSfbePI1_eIRra5zRyv6GCeLOH0KOOY9AxgzIm3lT5kWhdUnasmLZ4OLfBv97_S8KGc24
CitedBy_id crossref_primary_10_1016_j_arth_2018_07_020
crossref_primary_10_1016_j_knee_2018_08_019
crossref_primary_10_1007_s00167_018_4946_y
crossref_primary_10_1002_ksa_12731
crossref_primary_10_1007_s00167_020_05925_6
crossref_primary_10_1016_j_knee_2023_08_006
crossref_primary_10_2106_JBJS_CC_23_00378
crossref_primary_10_1016_j_arth_2018_04_010
crossref_primary_10_1016_j_medengphy_2017_10_003
crossref_primary_10_1016_j_jbiomech_2020_110042
crossref_primary_10_1302_0301_620X_102B1_BJJ_2019_0674_R2
crossref_primary_10_3389_fbioe_2021_673275
crossref_primary_10_1016_j_knee_2023_10_003
crossref_primary_10_1002_jor_25734
crossref_primary_10_1016_j_jmbbm_2019_103386
crossref_primary_10_1016_j_otsr_2017_11_015
crossref_primary_10_1016_j_arth_2017_06_037
crossref_primary_10_1097_CORR_0000000000000399
crossref_primary_10_1016_j_arth_2025_02_044
crossref_primary_10_1016_j_artd_2019_06_001
crossref_primary_10_1016_j_jmbbm_2021_104845
crossref_primary_10_1007_s00402_024_05743_2
crossref_primary_10_1016_j_artd_2024_101479
crossref_primary_10_1097_CORR_0000000000001202
Cites_doi 10.1016/S1063-4584(97)80030-1
10.1007/s00167-013-2481-4
10.1016/j.jbiomech.2004.02.024
10.1007/s11999-011-1988-6
10.1097/01.blo.0000148578.22729.0e
10.3928/0147-7447-19990301-06
10.1302/0301-620X.93B9.26573
10.1002/jor.22644
10.1007/s11999-009-1112-3
10.2106/00004623-200706000-00020
10.1243/09544119JEIM215
10.1016/j.arth.2013.02.038
10.3109/17453674.2014.913225
10.1016/j.knee.2010.04.012
10.1007/s11999-012-2613-z
10.1016/j.knee.2011.11.003
10.1016/S0883-5403(99)90078-5
10.1016/j.arth.2007.03.024
10.2106/00004623-199301000-00004
10.1016/j.arth.2009.04.034
10.1097/00003086-200111000-00015
10.1054/arth.2002.35796
10.1302/0301-620X.73B5.1894656
10.1002/jbm.820170510
10.2106/JBJS.J.00772
10.5435/00124635-200701000-00006
10.1016/j.arth.2013.05.029
10.2106/JBJS.I.01398
ContentType Journal Article
Copyright 2017 Elsevier Inc.
Elsevier Inc.
Copyright © 2017 Elsevier Inc. All rights reserved.
Copyright_xml – notice: 2017 Elsevier Inc.
– notice: Elsevier Inc.
– notice: Copyright © 2017 Elsevier Inc. All rights reserved.
DBID AAYXX
CITATION
CGR
CUY
CVF
ECM
EIF
NPM
7X8
DOI 10.1016/j.arth.2016.12.048
DatabaseName CrossRef
Medline
MEDLINE
MEDLINE (Ovid)
MEDLINE
MEDLINE
PubMed
MEDLINE - Academic
DatabaseTitle CrossRef
MEDLINE
Medline Complete
MEDLINE with Full Text
PubMed
MEDLINE (Ovid)
MEDLINE - Academic
DatabaseTitleList

MEDLINE
MEDLINE - Academic

Database_xml – sequence: 1
  dbid: NPM
  name: PubMed
  url: http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed
  sourceTypes: Index Database
– sequence: 2
  dbid: 7X8
  name: MEDLINE - Academic
  url: https://search.proquest.com/medline
  sourceTypes: Aggregation Database
DeliveryMethod fulltext_linktorsrc
EISSN 1532-8406
EndPage 2016
ExternalDocumentID 28209278
10_1016_j_arth_2016_12_048
S0883540316309342
1_s2_0_S0883540316309342
Genre Journal Article
GroupedDBID ---
--K
--M
.1-
.FO
.GJ
.~1
0R~
123
1B1
1P~
1RT
1~.
1~5
4.4
457
4G.
53G
5RE
5VS
7-5
71M
8P~
9JM
AABNK
AAEDT
AAEDW
AAIKJ
AAKOC
AALRI
AAOAW
AAQFI
AAQQT
AAQXK
AATTM
AAWTL
AAXKI
AAXUO
AAYWO
ABBQC
ABFNM
ABJNI
ABMAC
ABMZM
ABWVN
ABXDB
ACDAQ
ACGFO
ACGFS
ACIEU
ACLOT
ACRLP
ACRPL
ACVFH
ADBBV
ADCNI
ADEZE
ADMUD
ADNMO
AEBSH
AEIPS
AEKER
AENEX
AEUPX
AEVXI
AFJKZ
AFPUW
AFRHN
AFTJW
AFXIZ
AGHFR
AGQPQ
AGUBO
AGYEJ
AHHHB
AIEXJ
AIGII
AIIUN
AIKHN
AITUG
AJRQY
AJUYK
AKBMS
AKRWK
AKYEP
ALMA_UNASSIGNED_HOLDINGS
AMRAJ
ANKPU
ANZVX
APXCP
ASPBG
AVWKF
AXJTR
AZFZN
BKOJK
BLXMC
BNPGV
CAG
COF
CS3
DU5
EBS
EFJIC
EFKBS
EFLBG
EJD
EO8
EO9
EP2
EP3
F5P
FDB
FEDTE
FGOYB
FIRID
FNPLU
FYGXN
G-2
G-Q
GBLVA
HEB
HMK
HMO
HVGLF
HZ~
IHE
J1W
KOM
L7B
M29
M41
MO0
N9A
O-L
O9-
OAUVE
OF~
OR-
OZT
P-8
P-9
P2P
PC.
Q38
R2-
ROL
RPZ
SAE
SCC
SDF
SDG
SEL
SES
SEW
SJN
SPCBC
SSH
SSZ
T5K
UNMZH
UV1
WUQ
Z5R
ZGI
~G-
~HD
AACTN
AFCTW
AFKWA
AJOXV
AMFUW
RIG
AAIAV
ABLVK
ABYKQ
AJBFU
LCYCR
9DU
AAYXX
CITATION
CGR
CUY
CVF
ECM
EIF
NPM
7X8
ID FETCH-LOGICAL-c462t-493ecbf51ec1eb31874c9a538eda7a568582e19512fab6d99f1cf57154a00bec3
ISICitedReferencesCount 24
ISICitedReferencesURI http://www.webofscience.com/api/gateway?GWVersion=2&SrcApp=Summon&SrcAuth=ProQuest&DestLinkType=CitingArticles&DestApp=WOS_CPL&KeyUT=000402474300055&url=https%3A%2F%2Fcvtisr.summon.serialssolutions.com%2F%23%21%2Fsearch%3Fho%3Df%26include.ft.matches%3Dt%26l%3Dnull%26q%3D
ISSN 0883-5403
1532-8406
IngestDate Sat Oct 18 23:30:36 EDT 2025
Wed Feb 19 02:43:03 EST 2025
Tue Nov 18 22:19:35 EST 2025
Sat Nov 29 06:45:41 EST 2025
Fri Feb 23 02:16:58 EST 2024
Tue Feb 25 19:57:32 EST 2025
Tue Oct 14 19:35:30 EDT 2025
IsPeerReviewed true
IsScholarly true
Issue 6
Keywords coronal plane alignment
total knee arthroplasty
wear and damage
retrieval study
polyethylene wear
Language English
License Copyright © 2017 Elsevier Inc. All rights reserved.
LinkModel OpenURL
MergedId FETCHMERGED-LOGICAL-c462t-493ecbf51ec1eb31874c9a538eda7a568582e19512fab6d99f1cf57154a00bec3
Notes ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ORCID 0000-0002-0305-5280
PMID 28209278
PQID 1869967239
PQPubID 23479
PageCount 5
ParticipantIDs proquest_miscellaneous_1869967239
pubmed_primary_28209278
crossref_citationtrail_10_1016_j_arth_2016_12_048
crossref_primary_10_1016_j_arth_2016_12_048
elsevier_sciencedirect_doi_10_1016_j_arth_2016_12_048
elsevier_clinicalkeyesjournals_1_s2_0_S0883540316309342
elsevier_clinicalkey_doi_10_1016_j_arth_2016_12_048
PublicationCentury 2000
PublicationDate 2017-06-01
PublicationDateYYYYMMDD 2017-06-01
PublicationDate_xml – month: 06
  year: 2017
  text: 2017-06-01
  day: 01
PublicationDecade 2010
PublicationPlace United States
PublicationPlace_xml – name: United States
PublicationTitle The Journal of arthroplasty
PublicationTitleAlternate J Arthroplasty
PublicationYear 2017
Publisher Elsevier Inc
Publisher_xml – name: Elsevier Inc
References Estes, Schmidt, McLemore (bib4) 2013; 28
Cooke, Scudamore, Li (bib25) 1997; 5
Dennis, Komistek, Kim (bib33) 2010; 468
Werner, Ayers, Maletsky (bib14) 2005; 38
Fang, Ritter, Davis (bib16) 2009; 24
Matsuda, Whiteside, White (bib13) 1999; 22
Krushell, Fingeroth (bib6) 2007; 22
Cooke, Scudamore, Bryant (bib26) 1991; 73
Ritter, Davis, Meding (bib35) 2011; 93
Cooke, Sled, Scudamore (bib27) 2007; 34
Naudie, Ammeen, Engh (bib2) 2007; 15
D'Lima, Hermida, Chen (bib10) 2001
Miller, Pagnano, Kaufman (bib32) 2014; 32
Kilgus, Moreland, Finerman (bib1) 1991
Tsao, Mintz, McRae (bib3) 1993; 75
Magnussen, Weppe, Demey (bib21) 2011; 469
Lingaraj, Morris, Bartlett (bib29) 2011; 18
Hsu, Garg, Walker (bib12) 1989
Jonsson, Aström (bib20) 1988
Matsuda, Miura, Nagamine (bib7) 1999; 14
Howell, Howell, Kuznik (bib19) 2013; 471
Bonner, Eardley, Patterson (bib15) 2011; 93
Srivastava, Lee, Steklov (bib24) 2012; 19
Berend, Ritter, Meding (bib18) 2004; 428
Collier, Engh, McAuley (bib22) 2007; 89
Goldvasser, Hansen, Noz (bib28) 2014; 85
Hood, Wright, Burstein (bib30) 1983; 17
Green, Berend, Berend (bib11) 2002; 17
Bargren, Blaha, Freeman (bib9) 1983
Parratte, Pagnano, Trousdale (bib17) 2014; 92
Pang, Jamieson, Teeter (bib23) 2014; 29
Wasielewski, Galante, Leighty (bib8) 1994
Feng, Stulberg, Wixson (bib5) 1994
Jennings, Bell, Ingham (bib34) 2007; 221
Vanlommel, Vanlommel, Claes (bib31) 2013; 21
Howell (10.1016/j.arth.2016.12.048_bib19) 2013; 471
Parratte (10.1016/j.arth.2016.12.048_bib17) 2014; 92
Cooke (10.1016/j.arth.2016.12.048_bib26) 1991; 73
Feng (10.1016/j.arth.2016.12.048_bib5) 1994
Naudie (10.1016/j.arth.2016.12.048_bib2) 2007; 15
Magnussen (10.1016/j.arth.2016.12.048_bib21) 2011; 469
Matsuda (10.1016/j.arth.2016.12.048_bib7) 1999; 14
Srivastava (10.1016/j.arth.2016.12.048_bib24) 2012; 19
Werner (10.1016/j.arth.2016.12.048_bib14) 2005; 38
Pang (10.1016/j.arth.2016.12.048_bib23) 2014; 29
Hsu (10.1016/j.arth.2016.12.048_bib12) 1989
Hood (10.1016/j.arth.2016.12.048_bib30) 1983; 17
Wasielewski (10.1016/j.arth.2016.12.048_bib8) 1994
Estes (10.1016/j.arth.2016.12.048_bib4) 2013; 28
Bonner (10.1016/j.arth.2016.12.048_bib15) 2011; 93
Lingaraj (10.1016/j.arth.2016.12.048_bib29) 2011; 18
Fang (10.1016/j.arth.2016.12.048_bib16) 2009; 24
Dennis (10.1016/j.arth.2016.12.048_bib33) 2010; 468
Tsao (10.1016/j.arth.2016.12.048_bib3) 1993; 75
Jennings (10.1016/j.arth.2016.12.048_bib34) 2007; 221
Miller (10.1016/j.arth.2016.12.048_bib32) 2014; 32
Jonsson (10.1016/j.arth.2016.12.048_bib20) 1988
Goldvasser (10.1016/j.arth.2016.12.048_bib28) 2014; 85
Vanlommel (10.1016/j.arth.2016.12.048_bib31) 2013; 21
Cooke (10.1016/j.arth.2016.12.048_bib25) 1997; 5
Collier (10.1016/j.arth.2016.12.048_bib22) 2007; 89
Kilgus (10.1016/j.arth.2016.12.048_bib1) 1991
D'Lima (10.1016/j.arth.2016.12.048_bib10) 2001
Ritter (10.1016/j.arth.2016.12.048_bib35) 2011; 93
Krushell (10.1016/j.arth.2016.12.048_bib6) 2007; 22
Bargren (10.1016/j.arth.2016.12.048_bib9) 1983
Matsuda (10.1016/j.arth.2016.12.048_bib13) 1999; 22
Berend (10.1016/j.arth.2016.12.048_bib18) 2004; 428
Cooke (10.1016/j.arth.2016.12.048_bib27) 2007; 34
Green (10.1016/j.arth.2016.12.048_bib11) 2002; 17
References_xml – start-page: 124
  year: 1988
  ident: bib20
  article-title: Alignment and long-term clinical results of a semiconstrained knee prosthesis
  publication-title: Clin Orthop Relat Res
– volume: 221
  start-page: 305
  year: 2007
  ident: bib34
  article-title: The influence of femoral condylar lift-off on the wear of artificial knee joints
  publication-title: Proc Inst Mech Eng H
– volume: 22
  start-page: 77
  year: 2007
  ident: bib6
  article-title: Primary total knee arthroplasty in morbidly obese patients: a 5- to 14-year follow-up study
  publication-title: J Arthroplasty
– volume: 15
  start-page: 53
  year: 2007
  ident: bib2
  article-title: Wear and osteolysis around total knee arthroplasty
  publication-title: J Am Acad Orthop Surg
– volume: 93
  start-page: 1217
  year: 2011
  ident: bib15
  article-title: The effect of post-operative mechanical axis alignment on the survival of primary total knee replacements after a follow-up of 15 years
  publication-title: J Bone Joint Surg Br
– volume: 73
  start-page: 715
  year: 1991
  ident: bib26
  article-title: A quantitative approach to radiography of the lower limb. Principles and applications
  publication-title: J Bone Joint Surg Br
– volume: 29
  start-page: 365
  year: 2014
  ident: bib23
  article-title: Retrieval analysis of posterior stabilized polyethylene tibial inserts and its clinical relevance
  publication-title: J Arthroplasty
– volume: 468
  start-page: 102
  year: 2010
  ident: bib33
  article-title: Gap balancing versus measured resection technique for total knee arthroplasty
  publication-title: Clin Orthop Relat Res
– volume: 5
  start-page: 39
  year: 1997
  ident: bib25
  article-title: Axial lower-limb alignment: comparison of knee geometry in normal volunteers and osteoarthritis patients
  publication-title: Osteoarthritis Cartilage
– start-page: 135
  year: 1989
  ident: bib12
  article-title: Effect of knee component alignment on tibial load distribution with clinical correlation
  publication-title: Clin Orthop Relat Res
– start-page: 178
  year: 1983
  ident: bib9
  article-title: Alignment in total knee arthroplasty. Correlated biomechanical and clinical observations
  publication-title: Clin Orthop Relat Res
– volume: 17
  start-page: 829
  year: 1983
  ident: bib30
  article-title: Retrieval analysis of total knee prostheses: a method and its application to 48 total condylar prostheses
  publication-title: J Biomed Mater Res
– volume: 93
  start-page: 1588
  year: 2011
  ident: bib35
  article-title: The effect of alignment and BMI on failure of total knee replacement
  publication-title: J Bone Joint Surg Am
– start-page: 60
  year: 1994
  ident: bib5
  article-title: Progressive subluxation and polyethylene wear in total knee replacements with flat articular surfaces
  publication-title: Clin Orthop Relat Res
– volume: 21
  start-page: 2325
  year: 2013
  ident: bib31
  article-title: Slight undercorrection following total knee arthroplasty results in superior clinical outcomes in varus knees
  publication-title: Knee Surg Sports Traumatol Arthrosc
– volume: 28
  start-page: 101
  year: 2013
  ident: bib4
  article-title: Effect of body mass index on limb alignment after total knee arthroplasty
  publication-title: J Arthroplasty
– volume: 19
  start-page: 560
  year: 2012
  ident: bib24
  article-title: Effect of tibial component varus on wear in total knee arthroplasty
  publication-title: Knee
– volume: 38
  start-page: 349
  year: 2005
  ident: bib14
  article-title: The effect of valgus/varus malalignment on load distribution in total knee replacements
  publication-title: J Biomech
– volume: 92
  start-page: 2143
  year: 2014
  ident: bib17
  article-title: Effect of postoperative mechanical axis alignment on the fifteen-year survival of modern, cemented total knee replacements
  publication-title: J Bone Joint Surg Am
– volume: 85
  start-page: 271
  year: 2014
  ident: bib28
  article-title: In vivo and ex vivo measurement of polyethylene wear in total hip arthroplasty: comparison of measurements using a CT algorithm, a coordinate-measuring machine, and a micrometer
  publication-title: Acta Orthop
– volume: 14
  start-page: 566
  year: 1999
  ident: bib7
  article-title: Changes in knee alignment after total knee arthroplasty
  publication-title: J Arthroplasty
– volume: 471
  start-page: 1000
  year: 2013
  ident: bib19
  article-title: Does a kinematically aligned total knee arthroplasty restore function without failure regardless of alignment category?
  publication-title: Clin Orthop Relat Res
– volume: 18
  start-page: 165
  year: 2011
  ident: bib29
  article-title: Polyethylene thickness in unicompartmental knee arthroplasty
  publication-title: Knee
– volume: 34
  start-page: 1796
  year: 2007
  ident: bib27
  article-title: Frontal plane knee alignment: a call for standardized measurement
  publication-title: J Rheumatol
– volume: 32
  start-page: 1068
  year: 2014
  ident: bib32
  article-title: Tibiofemoral alignment in posterior stabilized total knee arthroplasty: static alignment does not predict dynamic tibial plateau loading
  publication-title: J Orthop Res
– start-page: 31
  year: 1994
  ident: bib8
  article-title: Wear patterns on retrieved polyethylene tibial inserts and their relationship to technical considerations during total knee arthroplasty
  publication-title: Clin Orthop Relat Res
– start-page: 124
  year: 2001
  ident: bib10
  article-title: Polyethylene wear and variations in knee kinematics
  publication-title: Clin Orthop Relat Res
– volume: 469
  start-page: 3443
  year: 2011
  ident: bib21
  article-title: Residual varus alignment does not compromise results of TKAs in patients with preoperative varus
  publication-title: Clin Orthop Relat Res
– volume: 89
  start-page: 1306
  year: 2007
  ident: bib22
  article-title: Factors associated with the loss of thickness of polyethylene tibial bearings after knee arthroplasty
  publication-title: J Bone Joint Surg Am
– volume: 17
  start-page: 1033
  year: 2002
  ident: bib11
  article-title: The effects of varus tibial alignment on proximal tibial surface strain in total knee arthroplasty: the posteromedial hot spot
  publication-title: J Arthroplasty
– volume: 75
  start-page: 19
  year: 1993
  ident: bib3
  article-title: Failure of the porous-coated anatomic prosthesis in total knee arthroplasty due to severe polyethylene wear
  publication-title: J Bone Joint Surg Am
– start-page: 223
  year: 1991
  ident: bib1
  article-title: Catastrophic wear of tibial polyethylene inserts
  publication-title: Clin Orthop Relat Res
– volume: 22
  start-page: 303
  year: 1999
  ident: bib13
  article-title: The effect of varus tilt on contact stresses in total knee arthroplasty: a biomechanical study
  publication-title: Orthopedics
– volume: 428
  start-page: 26
  year: 2004
  ident: bib18
  article-title: The Chetranjan Ranawat Award: tibial component failure mechanisms in total knee arthroplasty
  publication-title: Clin Orthop Relat Res
– volume: 24
  start-page: 39
  year: 2009
  ident: bib16
  article-title: Coronal alignment in total knee arthroplasty: just how important is it?
  publication-title: J Arthroplasty
– volume: 5
  start-page: 39
  year: 1997
  ident: 10.1016/j.arth.2016.12.048_bib25
  article-title: Axial lower-limb alignment: comparison of knee geometry in normal volunteers and osteoarthritis patients
  publication-title: Osteoarthritis Cartilage
  doi: 10.1016/S1063-4584(97)80030-1
– volume: 21
  start-page: 2325
  year: 2013
  ident: 10.1016/j.arth.2016.12.048_bib31
  article-title: Slight undercorrection following total knee arthroplasty results in superior clinical outcomes in varus knees
  publication-title: Knee Surg Sports Traumatol Arthrosc
  doi: 10.1007/s00167-013-2481-4
– volume: 38
  start-page: 349
  year: 2005
  ident: 10.1016/j.arth.2016.12.048_bib14
  article-title: The effect of valgus/varus malalignment on load distribution in total knee replacements
  publication-title: J Biomech
  doi: 10.1016/j.jbiomech.2004.02.024
– volume: 469
  start-page: 3443
  year: 2011
  ident: 10.1016/j.arth.2016.12.048_bib21
  article-title: Residual varus alignment does not compromise results of TKAs in patients with preoperative varus
  publication-title: Clin Orthop Relat Res
  doi: 10.1007/s11999-011-1988-6
– volume: 428
  start-page: 26
  year: 2004
  ident: 10.1016/j.arth.2016.12.048_bib18
  article-title: The Chetranjan Ranawat Award: tibial component failure mechanisms in total knee arthroplasty
  publication-title: Clin Orthop Relat Res
  doi: 10.1097/01.blo.0000148578.22729.0e
– volume: 22
  start-page: 303
  year: 1999
  ident: 10.1016/j.arth.2016.12.048_bib13
  article-title: The effect of varus tilt on contact stresses in total knee arthroplasty: a biomechanical study
  publication-title: Orthopedics
  doi: 10.3928/0147-7447-19990301-06
– volume: 93
  start-page: 1217
  year: 2011
  ident: 10.1016/j.arth.2016.12.048_bib15
  article-title: The effect of post-operative mechanical axis alignment on the survival of primary total knee replacements after a follow-up of 15 years
  publication-title: J Bone Joint Surg Br
  doi: 10.1302/0301-620X.93B9.26573
– volume: 32
  start-page: 1068
  year: 2014
  ident: 10.1016/j.arth.2016.12.048_bib32
  article-title: Tibiofemoral alignment in posterior stabilized total knee arthroplasty: static alignment does not predict dynamic tibial plateau loading
  publication-title: J Orthop Res
  doi: 10.1002/jor.22644
– volume: 468
  start-page: 102
  year: 2010
  ident: 10.1016/j.arth.2016.12.048_bib33
  article-title: Gap balancing versus measured resection technique for total knee arthroplasty
  publication-title: Clin Orthop Relat Res
  doi: 10.1007/s11999-009-1112-3
– volume: 89
  start-page: 1306
  year: 2007
  ident: 10.1016/j.arth.2016.12.048_bib22
  article-title: Factors associated with the loss of thickness of polyethylene tibial bearings after knee arthroplasty
  publication-title: J Bone Joint Surg Am
  doi: 10.2106/00004623-200706000-00020
– start-page: 223
  year: 1991
  ident: 10.1016/j.arth.2016.12.048_bib1
  article-title: Catastrophic wear of tibial polyethylene inserts
  publication-title: Clin Orthop Relat Res
– volume: 221
  start-page: 305
  year: 2007
  ident: 10.1016/j.arth.2016.12.048_bib34
  article-title: The influence of femoral condylar lift-off on the wear of artificial knee joints
  publication-title: Proc Inst Mech Eng H
  doi: 10.1243/09544119JEIM215
– volume: 28
  start-page: 101
  year: 2013
  ident: 10.1016/j.arth.2016.12.048_bib4
  article-title: Effect of body mass index on limb alignment after total knee arthroplasty
  publication-title: J Arthroplasty
  doi: 10.1016/j.arth.2013.02.038
– volume: 85
  start-page: 271
  year: 2014
  ident: 10.1016/j.arth.2016.12.048_bib28
  article-title: In vivo and ex vivo measurement of polyethylene wear in total hip arthroplasty: comparison of measurements using a CT algorithm, a coordinate-measuring machine, and a micrometer
  publication-title: Acta Orthop
  doi: 10.3109/17453674.2014.913225
– volume: 18
  start-page: 165
  year: 2011
  ident: 10.1016/j.arth.2016.12.048_bib29
  article-title: Polyethylene thickness in unicompartmental knee arthroplasty
  publication-title: Knee
  doi: 10.1016/j.knee.2010.04.012
– volume: 471
  start-page: 1000
  year: 2013
  ident: 10.1016/j.arth.2016.12.048_bib19
  article-title: Does a kinematically aligned total knee arthroplasty restore function without failure regardless of alignment category?
  publication-title: Clin Orthop Relat Res
  doi: 10.1007/s11999-012-2613-z
– volume: 19
  start-page: 560
  year: 2012
  ident: 10.1016/j.arth.2016.12.048_bib24
  article-title: Effect of tibial component varus on wear in total knee arthroplasty
  publication-title: Knee
  doi: 10.1016/j.knee.2011.11.003
– volume: 14
  start-page: 566
  year: 1999
  ident: 10.1016/j.arth.2016.12.048_bib7
  article-title: Changes in knee alignment after total knee arthroplasty
  publication-title: J Arthroplasty
  doi: 10.1016/S0883-5403(99)90078-5
– volume: 34
  start-page: 1796
  year: 2007
  ident: 10.1016/j.arth.2016.12.048_bib27
  article-title: Frontal plane knee alignment: a call for standardized measurement
  publication-title: J Rheumatol
– volume: 22
  start-page: 77
  year: 2007
  ident: 10.1016/j.arth.2016.12.048_bib6
  article-title: Primary total knee arthroplasty in morbidly obese patients: a 5- to 14-year follow-up study
  publication-title: J Arthroplasty
  doi: 10.1016/j.arth.2007.03.024
– volume: 75
  start-page: 19
  year: 1993
  ident: 10.1016/j.arth.2016.12.048_bib3
  article-title: Failure of the porous-coated anatomic prosthesis in total knee arthroplasty due to severe polyethylene wear
  publication-title: J Bone Joint Surg Am
  doi: 10.2106/00004623-199301000-00004
– volume: 24
  start-page: 39
  year: 2009
  ident: 10.1016/j.arth.2016.12.048_bib16
  article-title: Coronal alignment in total knee arthroplasty: just how important is it?
  publication-title: J Arthroplasty
  doi: 10.1016/j.arth.2009.04.034
– start-page: 124
  year: 2001
  ident: 10.1016/j.arth.2016.12.048_bib10
  article-title: Polyethylene wear and variations in knee kinematics
  publication-title: Clin Orthop Relat Res
  doi: 10.1097/00003086-200111000-00015
– volume: 17
  start-page: 1033
  year: 2002
  ident: 10.1016/j.arth.2016.12.048_bib11
  article-title: The effects of varus tibial alignment on proximal tibial surface strain in total knee arthroplasty: the posteromedial hot spot
  publication-title: J Arthroplasty
  doi: 10.1054/arth.2002.35796
– volume: 73
  start-page: 715
  year: 1991
  ident: 10.1016/j.arth.2016.12.048_bib26
  article-title: A quantitative approach to radiography of the lower limb. Principles and applications
  publication-title: J Bone Joint Surg Br
  doi: 10.1302/0301-620X.73B5.1894656
– volume: 17
  start-page: 829
  year: 1983
  ident: 10.1016/j.arth.2016.12.048_bib30
  article-title: Retrieval analysis of total knee prostheses: a method and its application to 48 total condylar prostheses
  publication-title: J Biomed Mater Res
  doi: 10.1002/jbm.820170510
– volume: 93
  start-page: 1588
  year: 2011
  ident: 10.1016/j.arth.2016.12.048_bib35
  article-title: The effect of alignment and BMI on failure of total knee replacement
  publication-title: J Bone Joint Surg Am
  doi: 10.2106/JBJS.J.00772
– start-page: 31
  year: 1994
  ident: 10.1016/j.arth.2016.12.048_bib8
  article-title: Wear patterns on retrieved polyethylene tibial inserts and their relationship to technical considerations during total knee arthroplasty
  publication-title: Clin Orthop Relat Res
– volume: 15
  start-page: 53
  year: 2007
  ident: 10.1016/j.arth.2016.12.048_bib2
  article-title: Wear and osteolysis around total knee arthroplasty
  publication-title: J Am Acad Orthop Surg
  doi: 10.5435/00124635-200701000-00006
– start-page: 135
  year: 1989
  ident: 10.1016/j.arth.2016.12.048_bib12
  article-title: Effect of knee component alignment on tibial load distribution with clinical correlation
  publication-title: Clin Orthop Relat Res
– start-page: 124
  year: 1988
  ident: 10.1016/j.arth.2016.12.048_bib20
  article-title: Alignment and long-term clinical results of a semiconstrained knee prosthesis
  publication-title: Clin Orthop Relat Res
– volume: 29
  start-page: 365
  year: 2014
  ident: 10.1016/j.arth.2016.12.048_bib23
  article-title: Retrieval analysis of posterior stabilized polyethylene tibial inserts and its clinical relevance
  publication-title: J Arthroplasty
  doi: 10.1016/j.arth.2013.05.029
– volume: 92
  start-page: 2143
  year: 2014
  ident: 10.1016/j.arth.2016.12.048_bib17
  article-title: Effect of postoperative mechanical axis alignment on the fifteen-year survival of modern, cemented total knee replacements
  publication-title: J Bone Joint Surg Am
  doi: 10.2106/JBJS.I.01398
– start-page: 178
  year: 1983
  ident: 10.1016/j.arth.2016.12.048_bib9
  article-title: Alignment in total knee arthroplasty. Correlated biomechanical and clinical observations
  publication-title: Clin Orthop Relat Res
– start-page: 60
  year: 1994
  ident: 10.1016/j.arth.2016.12.048_bib5
  article-title: Progressive subluxation and polyethylene wear in total knee replacements with flat articular surfaces
  publication-title: Clin Orthop Relat Res
SSID ssj0011554
Score 2.3255908
Snippet Coronal plane alignment is one of the contributing factors to polyethylene wear in total knee arthroplasty. Based on 95 retrieved polyethylene inserts, wear...
Abstract Background Coronal plane alignment is one of the contributing factors to polyethylene wear in total knee arthroplasty. Methods Based on 95 retrieved...
Coronal plane alignment is one of the contributing factors to polyethylene wear in total knee arthroplasty.BACKGROUNDCoronal plane alignment is one of the...
SourceID proquest
pubmed
crossref
elsevier
SourceType Aggregation Database
Index Database
Enrichment Source
Publisher
StartPage 2012
SubjectTerms Aged
Arthroplasty, Replacement, Knee - instrumentation
Arthroplasty, Replacement, Knee - methods
Body Mass Index
coronal plane alignment
Extremities
Female
Humans
Knee Prosthesis
Male
Middle Aged
Orthopedics
Polyethylene - chemistry
polyethylene wear
Prosthesis Failure
retrieval study
Tibia - surgery
total knee arthroplasty
wear and damage
Title The Impact of Coronal Plane Alignment on Polyethylene Wear and Damage in Total Knee Arthroplasty: A Retrieval Study
URI https://www.clinicalkey.com/#!/content/1-s2.0-S0883540316309342
https://www.clinicalkey.es/playcontent/1-s2.0-S0883540316309342
https://dx.doi.org/10.1016/j.arth.2016.12.048
https://www.ncbi.nlm.nih.gov/pubmed/28209278
https://www.proquest.com/docview/1869967239
Volume 32
WOSCitedRecordID wos000402474300055&url=https%3A%2F%2Fcvtisr.summon.serialssolutions.com%2F%23%21%2Fsearch%3Fho%3Df%26include.ft.matches%3Dt%26l%3Dnull%26q%3D
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
journalDatabaseRights – providerCode: PRVESC
  databaseName: Elsevier SD Freedom Collection Journals 2021
  customDbUrl:
  eissn: 1532-8406
  dateEnd: 99991231
  omitProxy: false
  ssIdentifier: ssj0011554
  issn: 0883-5403
  databaseCode: AIEXJ
  dateStart: 19951101
  isFulltext: true
  titleUrlDefault: https://www.sciencedirect.com
  providerName: Elsevier
link http://cvtisr.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwtV1Lb9NAEF6FlgMXBOIVHtUicbMc-W0vt6gU6EMRKqHktrKdMSQNdpWkUftH-T3MeNcbE9rykLhYie312jufZ2fH38ww9iqhrOkoTjsf-4EdiNy3RYoCcaIswNkS0qxOu3hyFA8GyWgkPnQ635tYmNUsLsvk4kKc_VdR4z4UNoXO_oW4zUVxB_5GoeMWxY7bPxb8vol93KUMBSgGKk4EVn82-aI__5dEfbsElBPOO2B9poQ-NS05_UY0nklpDSsKlDwsAciFT-UU0NJeXqpY9uO6EteKcomYBLXT9Q207Ny01bYR7wm5rk9hnp9-rVYqzGxCvBz7ANXNsHfYMw4FAF05RBcmt96ZY4OUKJCtVYD1pndsjio-sCECW0e9toPDjddELOV1ayJvfiKGonKsSR1KOUKjvFG7B07U1u5r7-mmqnY0fxuav9GVU4rybkx7NFpEBYxq97FKD7qRqvsj3RXdFBq5jvADNA22vTgUqG23-_t7owPzfYusOLW-UU-hw7kU83Czp-tMpuuWRLVpNLzH7mpZ877C4n3WgfIBWyAMuMIhrwqucchrHHKDQ16VvI1DTjjkiA6ucMgnJa9xyAmHvI3D17zPDQp5jcKH7NPbveHue1tX-LDzIPKWqBt8yLMidCF3IfOpPmQuUpyDYZzGaUi1ETxwcRHgFWkWjYUo3LwIYzT7U8dB7eM_YltlVcITxsF1I7xQ6IVBTJNSVgRhkWRovzsQjR3RZW4ziDLX6e-pCstMNjzHqaSBlzTw0vUkDnyXWabNmUr-cuPZfiMb2YQ140QsEUg3toqvagULrVIW0pULPFP-Aq4uC01LbS4rM_i3Pb5sgCNxLqEPhCj56hx7SiIhotjzcbQeK0SZ5_ZwqSC8OHn6j70-Y3fWL_dztrWcn8MLdjtfLSeL-Q67FY-SHf2W_AA97ffQ
linkProvider Elsevier
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=The+Impact+of+Coronal+Plane+Alignment+on+Polyethylene+Wear+and+Damage+in+Total+Knee+Arthroplasty%3A+A+Retrieval+Study&rft.jtitle=The+Journal+of+arthroplasty&rft.au=Vandekerckhove%2C+Pieter-Jan+T.K.&rft.au=Teeter%2C+Matthew+G.&rft.au=Naudie%2C+Douglas+D.R.&rft.au=Howard%2C+James+L.&rft.date=2017-06-01&rft.pub=Elsevier+Inc&rft.issn=0883-5403&rft.eissn=1532-8406&rft.volume=32&rft.issue=6&rft.spage=2012&rft.epage=2016&rft_id=info:doi/10.1016%2Fj.arth.2016.12.048&rft.externalDocID=S0883540316309342
thumbnail_m http://cvtisr.summon.serialssolutions.com/2.0.0/image/custom?url=https%3A%2F%2Fcdn.clinicalkey.com%2Fck-thumbnails%2F08835403%2FS0883540316X00186%2Fcov150h.gif