The Impact of Coronal Plane Alignment on Polyethylene Wear and Damage in Total Knee Arthroplasty: A Retrieval Study

Coronal plane alignment is one of the contributing factors to polyethylene wear in total knee arthroplasty. Based on 95 retrieved polyethylene inserts, wear and damage patterns were analyzed in relationship to the overall mechanical alignment and to the position of the tibial component. A progressio...

Celý popis

Uložené v:
Podrobná bibliografia
Vydané v:The Journal of arthroplasty Ročník 32; číslo 6; s. 2012 - 2016
Hlavní autori: Vandekerckhove, Pieter-Jan T.K., Teeter, Matthew G., Naudie, Douglas D.R., Howard, James L., MacDonald, Steven J., Lanting, Brent A.
Médium: Journal Article
Jazyk:English
Vydavateľské údaje: United States Elsevier Inc 01.06.2017
Predmet:
ISSN:0883-5403, 1532-8406, 1532-8406
On-line prístup:Získať plný text
Tagy: Pridať tag
Žiadne tagy, Buďte prvý, kto otaguje tento záznam!
Popis
Shrnutí:Coronal plane alignment is one of the contributing factors to polyethylene wear in total knee arthroplasty. Based on 95 retrieved polyethylene inserts, wear and damage patterns were analyzed in relationship to the overall mechanical alignment and to the position of the tibial component. A progression of wear was observed with progressively mechanical varus alignment. However, there was significantly more damage in the lateral compartment in the mild and moderate varus group compared to the valgus group. No difference in damage was seen between all groups for tibial component positioning in valgus or varus. Progressive wear was observed with progressively varus alignment with more damage at the lateral side. This observation is unique and might be explained by lateral condylar lift-off inducing impact and shear loading in the varus group.
Bibliografia:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0883-5403
1532-8406
1532-8406
DOI:10.1016/j.arth.2016.12.048