Surface determination algorithm for accurate XCT bidirectional length measurements
Surface determination plays an important role in XCT bi-directional length measurement, however, its effect on the measurement results is often overlooked or hidden by other error sources. Most of the published research in dimensional field used the Canny algorithm or the surface determination modul...
Uloženo v:
| Vydáno v: | Precision engineering Ročník 85; s. 40 - 47 |
|---|---|
| Hlavní autoři: | , , |
| Médium: | Journal Article |
| Jazyk: | angličtina |
| Vydáno: |
Elsevier Inc
01.01.2024
|
| ISSN: | 0141-6359, 1873-2372 |
| On-line přístup: | Získat plný text |
| Tagy: |
Přidat tag
Žádné tagy, Buďte první, kdo vytvoří štítek k tomuto záznamu!
|
| Abstract | Surface determination plays an important role in XCT bi-directional length measurement, however, its effect on the measurement results is often overlooked or hidden by other error sources. Most of the published research in dimensional field used the Canny algorithm or the surface determination module in VGStudio. Both of them require input from the operator that can also affect the accuracy of the measurements. Alternatively, the marker-controlled watershed (MCW) algorithm has been proven to avoid the latter issue, however, there is no systematic study that evaluated the surface determination algorithm's effect on the accuracy of bi-directional length measurements. In this study a two-sphere reference sample was measured using an XCT scanner and, with the aid of simulations, the effect of the three surface determination methods on bi-directional length measurements was comprehensively studied.
The results show that in the presence of ‘streak’ artefacts, a beam hardening error, if the operator does not set parameters appropriately, Canny and VGStudio implementations lead to either loss of surface or large errors, whereas MCW avoids this issue demonstrating its process automation ability. Nevertheless, with voxel calibration, beam hardening correction and data manipulation, MCW and Canny algorithms enable accurate sphere radius measurements (bi-directional measurements), comparable to the accuracy of an industrial tactile coordinate measuring machine.
•MCW evaluated as an automated surface determination algorithm for XCT 3D dimensional measurements.•SD-s such Canny and VGStudio require optimisation of the user inputs.•With appropriate voxel calibration and beam hardening correction, MCW and Canny enable sub-micron XCT dimensional accuracy. |
|---|---|
| AbstractList | Surface determination plays an important role in XCT bi-directional length measurement, however, its effect on the measurement results is often overlooked or hidden by other error sources. Most of the published research in dimensional field used the Canny algorithm or the surface determination module in VGStudio. Both of them require input from the operator that can also affect the accuracy of the measurements. Alternatively, the marker-controlled watershed (MCW) algorithm has been proven to avoid the latter issue, however, there is no systematic study that evaluated the surface determination algorithm's effect on the accuracy of bi-directional length measurements. In this study a two-sphere reference sample was measured using an XCT scanner and, with the aid of simulations, the effect of the three surface determination methods on bi-directional length measurements was comprehensively studied.
The results show that in the presence of ‘streak’ artefacts, a beam hardening error, if the operator does not set parameters appropriately, Canny and VGStudio implementations lead to either loss of surface or large errors, whereas MCW avoids this issue demonstrating its process automation ability. Nevertheless, with voxel calibration, beam hardening correction and data manipulation, MCW and Canny algorithms enable accurate sphere radius measurements (bi-directional measurements), comparable to the accuracy of an industrial tactile coordinate measuring machine.
•MCW evaluated as an automated surface determination algorithm for XCT 3D dimensional measurements.•SD-s such Canny and VGStudio require optimisation of the user inputs.•With appropriate voxel calibration and beam hardening correction, MCW and Canny enable sub-micron XCT dimensional accuracy. |
| Author | Sun, Wenjuan Yang, Xiuyuan Giusca, Claudiu L. |
| Author_xml | – sequence: 1 givenname: Xiuyuan orcidid: 0000-0002-2136-5821 surname: Yang fullname: Yang, Xiuyuan organization: Surface Engineering and Precision Centre, Cranfield University, Cranfield, Bedfordshire MK430AL, United Kingdom – sequence: 2 givenname: Wenjuan surname: Sun fullname: Sun, Wenjuan email: wenjuan.sun@npl.co.uk organization: Engineering Department, National Physical Laboratory, Hampton Road, Teddington TW11 0LW, United Kingdom – sequence: 3 givenname: Claudiu L. orcidid: 0000-0003-3765-5660 surname: Giusca fullname: Giusca, Claudiu L. email: c.giusca@cranfield.ac.uk organization: Surface Engineering and Precision Centre, Cranfield University, Cranfield, Bedfordshire MK430AL, United Kingdom |
| BookMark | eNqNkMtKAzEUhoNUsK2-Q3A_Yy4zkxlXSr1CQdAK7kImOWlT5lKSjODbO7UuxFVXBw7n_37ON0OTru8AoUtKUkpocbVNdx60C25cd-uUEcZTUqWE8BM0paXgCeOCTdCU0IwmBc-rMzQLYUsIESXJpuj1bfBWacAGIvjWdSqOLKyade9d3LTY9h4rrQevIuCPxQrXzrixc3-mGtyMtXGDW1Bh8NBCF8M5OrWqCXDxO-fo_eF-tXhKli-Pz4vbZaKzjMXEFCB4zfNa6cJopjjPKc0ty43JgNYio7QEgJwbwbQpS5uLCoqCWlZWXCnB5-j6wNW-D8GDlTvvWuW_JCVyb0du5V87cm9HkkqOdsbwzb-wdvHn9-iVa45D3B0QMD756cDLoB10Gg5-pOndMZhv02uPTw |
| CitedBy_id | crossref_primary_10_1007_s41871_024_00239_4 crossref_primary_10_3390_ma17246172 crossref_primary_10_1016_j_measurement_2025_118439 crossref_primary_10_1007_s10921_025_01223_8 crossref_primary_10_1016_j_est_2025_117835 crossref_primary_10_20965_ijat_2024_p0659 |
| Cites_doi | 10.1088/1361-6633/ac43f6 10.1016/j.precisioneng.2022.05.005 10.1016/j.cirp.2017.04.075 10.1118/1.3577758 10.1088/0957-0233/27/8/085004 10.1016/j.precisioneng.2020.03.004 10.1109/2945.817348 10.1016/j.nima.2015.05.015 10.1088/0031-9155/24/1/008 10.1016/j.precisioneng.2020.08.004 10.1016/j.precisioneng.2020.08.014 10.1016/j.cirp.2017.04.074 10.1088/2051-672X/3/2/024002 10.1515/teme-2019-0116 10.1088/0957-0233/25/6/064014 10.1088/1361-6501/aab1a1 10.1016/j.precisioneng.2019.06.007 10.1016/j.precisioneng.2016.12.008 10.1016/j.precisioneng.2022.05.003 10.1016/j.precisioneng.2016.06.001 10.1016/j.cirp.2015.05.010 10.1088/0957-0233/27/1/015007 10.1016/j.ndteint.2022.102697 10.1016/j.precisioneng.2022.10.001 10.1016/j.precisioneng.2019.02.004 10.1016/j.powtec.2019.08.028 10.3390/s21020591 10.1021/ac101522q 10.1088/0957-0233/27/7/072001 10.1016/j.procir.2016.02.123 10.1023/B:METE.0000043654.30424.3f 10.1016/j.precisioneng.2019.10.004 10.1016/j.precisioneng.2018.02.009 10.1007/s00170-018-1950-9 10.1088/0957-0233/20/8/084021 10.1016/j.cirp.2011.05.006 10.1016/j.matdes.2019.108385 10.1088/1361-6501/aa85b7 10.3233/XST-140471 10.1088/0957-0233/23/8/085404 10.1016/j.csndt.2016.05.005 10.1088/1361-6501/aa80b2 10.1016/j.cirp.2012.03.013 10.1016/j.procir.2016.02.018 10.1016/j.cirp.2013.03.016 |
| ContentType | Journal Article |
| Copyright | 2023 |
| Copyright_xml | – notice: 2023 |
| DBID | 6I. AAFTH AAYXX CITATION |
| DOI | 10.1016/j.precisioneng.2023.09.003 |
| DatabaseName | ScienceDirect Open Access Titles Elsevier:ScienceDirect:Open Access CrossRef |
| DatabaseTitle | CrossRef |
| DatabaseTitleList | |
| DeliveryMethod | fulltext_linktorsrc |
| Discipline | Engineering |
| EISSN | 1873-2372 |
| EndPage | 47 |
| ExternalDocumentID | 10_1016_j_precisioneng_2023_09_003 S0141635923001599 |
| GroupedDBID | --K --M .~1 0R~ 123 1B1 1~. 1~5 29O 4.4 457 4G. 5VS 6I. 7-5 71M 8P~ 9JN AABXZ AACTN AAEDT AAEDW AAEPC AAFTH AAIAV AAIKJ AAKOC AALRI AAOAW AAQFI AAQXK AAXUO ABFNM ABJNI ABMAC ABXDB ABXRA ABYKQ ACDAQ ACGFS ACNNM ACRLP ADBBV ADEZE ADMUD ADTZH AEBSH AECPX AEKER AEZYN AFKWA AFRZQ AFTJW AGHFR AGUBO AGYEJ AHHHB AHJVU AIEXJ AIKHN AITUG AJBFU AJOXV ALMA_UNASSIGNED_HOLDINGS AMFUW AMRAJ ASPBG AVWKF AXJTR AZFZN BJAXD BKOJK BLXMC CS3 EBS EFJIC EFLBG EJD EO8 EO9 EP2 EP3 FDB FEDTE FGOYB FIRID FNPLU FYGXN G-2 G-Q GBLVA HVGLF HZ~ IHE J1W JJJVA KOM LY7 M41 MAGPM MO0 N9A O-L O9- OAUVE OZT P-8 P-9 P2P PC. Q38 R2- RIG RNS ROL RPZ SDF SDG SDP SES SET SEW SPC SPCBC SSM SST SSZ T5K TN5 UHS WH7 WUQ XPP ZMT ~G- 9DU AATTM AAXKI AAYWO AAYXX ABWVN ACLOT ACRPL ADNMO AEIPS AFJKZ AGQPQ AIIUN ANKPU APXCP CITATION EFKBS ~HD |
| ID | FETCH-LOGICAL-c442t-d6e73b35bac6dc2a335115f25dd4e1b74118eee53d72cd88f579e661f2893aa73 |
| ISICitedReferencesCount | 7 |
| ISICitedReferencesURI | http://www.webofscience.com/api/gateway?GWVersion=2&SrcApp=Summon&SrcAuth=ProQuest&DestLinkType=CitingArticles&DestApp=WOS_CPL&KeyUT=001084462900001&url=https%3A%2F%2Fcvtisr.summon.serialssolutions.com%2F%23%21%2Fsearch%3Fho%3Df%26include.ft.matches%3Dt%26l%3Dnull%26q%3D |
| ISSN | 0141-6359 |
| IngestDate | Tue Nov 18 22:01:51 EST 2025 Sat Nov 29 07:29:02 EST 2025 Fri Feb 23 02:38:07 EST 2024 |
| IsDoiOpenAccess | true |
| IsOpenAccess | true |
| IsPeerReviewed | true |
| IsScholarly | true |
| Language | English |
| License | This is an open access article under the CC BY license. |
| LinkModel | OpenURL |
| MergedId | FETCHMERGED-LOGICAL-c442t-d6e73b35bac6dc2a335115f25dd4e1b74118eee53d72cd88f579e661f2893aa73 |
| ORCID | 0000-0003-3765-5660 0000-0002-2136-5821 |
| OpenAccessLink | https://dx.doi.org/10.1016/j.precisioneng.2023.09.003 |
| PageCount | 8 |
| ParticipantIDs | crossref_primary_10_1016_j_precisioneng_2023_09_003 crossref_citationtrail_10_1016_j_precisioneng_2023_09_003 elsevier_sciencedirect_doi_10_1016_j_precisioneng_2023_09_003 |
| PublicationCentury | 2000 |
| PublicationDate | January 2024 2024-01-00 |
| PublicationDateYYYYMMDD | 2024-01-01 |
| PublicationDate_xml | – month: 01 year: 2024 text: January 2024 |
| PublicationDecade | 2020 |
| PublicationTitle | Precision engineering |
| PublicationYear | 2024 |
| Publisher | Elsevier Inc |
| Publisher_xml | – name: Elsevier Inc |
| References | Rasoulpour, Kamali-Asl, Hemmati (bib38) 2015; 794 Townsend, Racasan, Leach, Senin, Thompson, Ramsey (bib16) 2018; 23 Zanini, Carmignato, Savio, Affatato (bib2) 2018; 52 Flay, Brown, Sun, Blumensath, Su (bib18) 2020; 66 Townsend, Pagani, Scott, Blunt (bib25) 2017; 48 Aloisi, Carmignato (bib32) 2016; 6 Sun, Giusca, Lou, Yang, Chen, Fry (bib7) 2022; 50 Zanini, Carmignato (bib5) 2022; 77 Müller, Butzhammer, Wohlgemuth, Hausotte (bib50) 2020; 87 Schwaninger, Hadjis (bib60) 1998 Kiekens (bib63) 2017 Villarraga-Gómez, Morse, Smith (bib3) 2023; 79 Levine, Blattner, Peskin, Pintar (bib53) 2019 Lohvithee, Sun, Chretien, Soleimani (bib19) 2021; 21 Hiller, Maisl, Reindl (bib62) 2012; 23 Ametova, Ferrucci, Chilingaryan, Dewulf (bib51) 2018; 29 Zwanenburg, Williams, Warnett (bib4) 2022; 77 Sun, Zheng, Li (bib48) 2019; 356 Sun, Brown, Woolliams, McCarthy, White, Attallah (bib17) 2016 Van Gompel, Van Slambrouck, Defrise, Batenburg, de Mey, Sijbers (bib35) 2011; 38 Kraemer, Lanza (bib39) 2016; 43 Carmignato, Dreossi, Mancini, Marinello, Tromba, Savio (bib30) 2009; 20 Nathanael (bib43) 2020 Fei, Dantan, Baudouin, Du (bib54) 2019; 57 Staude (bib47) 2012 Thompson, Maskery, Leach, Thompson, Maskery, Leach (bib8) 2016; 27 Reinhart, Weg (bib44) 2008 Patterson, Hamilton (bib46) 2010; 82 Sun, Brown, Flay, McCarthy, McBride (bib20) 2016; 27 Villarraga-Gómez, Thousand, Smith (bib13) 2020; 64 Zanini (bib52) 2017; 28 Lifton, Malcolm, McBride (bib33) 2015; 23 Müller (bib45) 2010 Thompson, Senin, Giusca, Leach (bib58) 2017; 66 Graphics (bib68) 2016 du Plessis, Yadroitsava, Yadroitsev (bib10) 2020; 187 Torralba, Jiménez, Yagüe-Fabra, Ontiveros, Tosello (bib55) 2018; 97 Sun, Symes, Brenner, Böhnel, Brown, Mavrogordato (bib14) 2022; 85 Lifton, Liu (bib57) 2020; 61 Flay, Sun, Brown, Leach, Blumensath (bib70) 2015 Müller, Hiller, Cantatore, De Chiffre (bib31) 2011 Fleßner, Müller, Helmecke, Hausotte (bib49) 2015 Kruth, Bartscher, Carmignato, Schmitt, De Chiffre, Weckenmann (bib1) 2011; 60 Villarraga-Gómez, Herazo, Smith (bib6) 2019; 60 Angel, De Chiffre (bib26) 2013 Lifton (bib42) 2015 Lifton, Malcolm, McBride (bib69) 2016; 27 Kumar, Prajapati, Singh (bib61) 2011; 2 Lifton, Carmignato (bib29) 2017; 28 Bellon, Jaenisch (bib64) 2007 Romanov (bib71) 2004; 47 Yagüe-Fabra, Ontiveros, Jiménez, Chitchian, Tosello, Carmignato (bib66) 2013; 62 Sun, Brown, Leach (bib41) 2012 Jennings (bib67) 2022 Leach, Haitjema, Su, Thompson (bib11) 2020; 32 Carmignato, Pierobon, Savio (bib15) 2012 Leach, Giusca, Haitjema, Evans, Jiang (bib22) 2015; 64 Triantaphyllou, Giusca, Macaulay, Roerig, Hoebel, Leach (bib23) 2015; 3 Herman (bib34) 1979; 24 Rodríguez-Sánchez, Thompson, Körner, Brierley, Leach (bib12) 2020; 66 Tan, Kiekens, Welkenhuyzen, Angel, De Chiffre, Kruth (bib72) 2014; 25 Townsend, Senin, Blunt, Leach, Taylor (bib9) 2016; 46 Stolfi, De Chiffre (bib27) 2016 Yang, Sun, Giusca (bib28) 2022; 131 Leach (bib21) 2001 Townsend, Pagani, Blunt, Scott, Jiang (bib24) 2017; 66 Tan, Kiekens, Welkenhuyzen, Kruth, Dewulf (bib37) 2012 Steinbeiß (bib56) 2005 Mangan, Whitaker (bib65) 1999; 5 Kathryn, Chiffre, Stolfi, Kathryn Thompson, Carli, De Chiffre (bib40) 2016; 43 Dewulf, Tan, Kiekens (bib36) 2012; 61 Mistree, Lautenschlager, Erikstad, Allen (bib59) 1993 Flay (10.1016/j.precisioneng.2023.09.003_bib70) 2015 Carmignato (10.1016/j.precisioneng.2023.09.003_bib15) 2012 Zanini (10.1016/j.precisioneng.2023.09.003_bib2) 2018; 52 Kumar (10.1016/j.precisioneng.2023.09.003_bib61) 2011; 2 Sun (10.1016/j.precisioneng.2023.09.003_bib48) 2019; 356 Tan (10.1016/j.precisioneng.2023.09.003_bib72) 2014; 25 Villarraga-Gómez (10.1016/j.precisioneng.2023.09.003_bib13) 2020; 64 Zanini (10.1016/j.precisioneng.2023.09.003_bib5) 2022; 77 Romanov (10.1016/j.precisioneng.2023.09.003_bib71) 2004; 47 Torralba (10.1016/j.precisioneng.2023.09.003_bib55) 2018; 97 Schwaninger (10.1016/j.precisioneng.2023.09.003_bib60) 1998 Lifton (10.1016/j.precisioneng.2023.09.003_bib29) 2017; 28 Sun (10.1016/j.precisioneng.2023.09.003_bib17) 2016 Townsend (10.1016/j.precisioneng.2023.09.003_bib25) 2017; 48 Zanini (10.1016/j.precisioneng.2023.09.003_bib52) 2017; 28 Nathanael (10.1016/j.precisioneng.2023.09.003_bib43) 2020 Lifton (10.1016/j.precisioneng.2023.09.003_bib57) 2020; 61 Leach (10.1016/j.precisioneng.2023.09.003_bib21) 2001 Thompson (10.1016/j.precisioneng.2023.09.003_bib8) 2016; 27 Dewulf (10.1016/j.precisioneng.2023.09.003_bib36) 2012; 61 du Plessis (10.1016/j.precisioneng.2023.09.003_bib10) 2020; 187 Mangan (10.1016/j.precisioneng.2023.09.003_bib65) 1999; 5 Fleßner (10.1016/j.precisioneng.2023.09.003_bib49) 2015 Stolfi (10.1016/j.precisioneng.2023.09.003_bib27) 2016 Patterson (10.1016/j.precisioneng.2023.09.003_bib46) 2010; 82 Reinhart (10.1016/j.precisioneng.2023.09.003_bib44) 2008 Rodríguez-Sánchez (10.1016/j.precisioneng.2023.09.003_bib12) 2020; 66 Staude (10.1016/j.precisioneng.2023.09.003_bib47) 2012 Kraemer (10.1016/j.precisioneng.2023.09.003_bib39) 2016; 43 Aloisi (10.1016/j.precisioneng.2023.09.003_bib32) 2016; 6 Müller (10.1016/j.precisioneng.2023.09.003_bib50) 2020; 87 Van Gompel (10.1016/j.precisioneng.2023.09.003_bib35) 2011; 38 Townsend (10.1016/j.precisioneng.2023.09.003_bib9) 2016; 46 Müller (10.1016/j.precisioneng.2023.09.003_bib45) 2010 Jennings (10.1016/j.precisioneng.2023.09.003_bib67) 2022 Villarraga-Gómez (10.1016/j.precisioneng.2023.09.003_bib6) 2019; 60 Townsend (10.1016/j.precisioneng.2023.09.003_bib16) 2018; 23 Hiller (10.1016/j.precisioneng.2023.09.003_bib62) 2012; 23 Graphics (10.1016/j.precisioneng.2023.09.003_bib68) 2016 Lifton (10.1016/j.precisioneng.2023.09.003_bib69) 2016; 27 Yagüe-Fabra (10.1016/j.precisioneng.2023.09.003_bib66) 2013; 62 Sun (10.1016/j.precisioneng.2023.09.003_bib41) 2012 Herman (10.1016/j.precisioneng.2023.09.003_bib34) 1979; 24 Carmignato (10.1016/j.precisioneng.2023.09.003_bib30) 2009; 20 Kiekens (10.1016/j.precisioneng.2023.09.003_bib63) 2017 Yang (10.1016/j.precisioneng.2023.09.003_bib28) 2022; 131 Bellon (10.1016/j.precisioneng.2023.09.003_bib64) 2007 Sun (10.1016/j.precisioneng.2023.09.003_bib20) 2016; 27 Rasoulpour (10.1016/j.precisioneng.2023.09.003_bib38) 2015; 794 Ametova (10.1016/j.precisioneng.2023.09.003_bib51) 2018; 29 Mistree (10.1016/j.precisioneng.2023.09.003_bib59) 1993 Sun (10.1016/j.precisioneng.2023.09.003_bib14) 2022; 85 Müller (10.1016/j.precisioneng.2023.09.003_bib31) 2011 Kruth (10.1016/j.precisioneng.2023.09.003_bib1) 2011; 60 Angel (10.1016/j.precisioneng.2023.09.003_bib26) 2013 Steinbeiß (10.1016/j.precisioneng.2023.09.003_bib56) 2005 Zwanenburg (10.1016/j.precisioneng.2023.09.003_bib4) 2022; 77 Leach (10.1016/j.precisioneng.2023.09.003_bib22) 2015; 64 Lifton (10.1016/j.precisioneng.2023.09.003_bib33) 2015; 23 Leach (10.1016/j.precisioneng.2023.09.003_bib11) 2020; 32 Lifton (10.1016/j.precisioneng.2023.09.003_bib42) 2015 Villarraga-Gómez (10.1016/j.precisioneng.2023.09.003_bib3) 2023; 79 Flay (10.1016/j.precisioneng.2023.09.003_bib18) 2020; 66 Triantaphyllou (10.1016/j.precisioneng.2023.09.003_bib23) 2015; 3 Townsend (10.1016/j.precisioneng.2023.09.003_bib24) 2017; 66 Levine (10.1016/j.precisioneng.2023.09.003_bib53) 2019 Tan (10.1016/j.precisioneng.2023.09.003_bib37) 2012 Kathryn (10.1016/j.precisioneng.2023.09.003_bib40) 2016; 43 Sun (10.1016/j.precisioneng.2023.09.003_bib7) 2022; 50 Lohvithee (10.1016/j.precisioneng.2023.09.003_bib19) 2021; 21 Thompson (10.1016/j.precisioneng.2023.09.003_bib58) 2017; 66 Fei (10.1016/j.precisioneng.2023.09.003_bib54) 2019; 57 |
| References_xml | – volume: 28 year: 2017 ident: bib52 article-title: Two-spheres method for evaluating the metrological structural resolution in dimensional computed tomography publication-title: Meas Sci Technol – year: 2008 ident: bib44 article-title: Industrial computer tomography - a universal inspection tool. 17th world conference on nondestructive testing – volume: 23 year: 2012 ident: bib62 article-title: Physical characterization and performance evaluation of an x-ray micro-computed tomography system for dimensional metrology applications publication-title: Meas Sci Technol – start-page: 337 year: 2016 end-page: 345 ident: bib17 article-title: Applications and systematic errors of X-ray computed tomography associated with dimensional metrology publication-title: 55th annual conference of the British institute of non-destructive testing, NDT 2016 – year: 2016 ident: bib68 article-title: VGStudio MAX 3.0 publication-title: Reference Manual – volume: 27 year: 2016 ident: bib20 article-title: A reference sample for investigating the stability of the imaging system of x-ray computed tomography publication-title: Meas Sci Technol – volume: 23 start-page: 65 year: 2015 end-page: 82 ident: bib33 article-title: A simulation-based study on the influence of beam hardening in X-ray computed tomography for dimensional metrology publication-title: J X Ray Sci Technol – volume: 28 year: 2017 ident: bib29 article-title: Simulating the influence of scatter and beam hardening in dimensional computed tomography publication-title: Meas Sci Technol – volume: 2 start-page: 1 year: 2011 end-page: 14 ident: bib61 article-title: Implementation of Taguchi methodology for defect reduction in manufacturing industry "A case study" publication-title: Int J Ind Eng Res Dev – volume: 187 year: 2020 ident: bib10 article-title: Effects of defects on mechanical properties in metal additive manufacturing: a review focusing on X-ray tomography insights publication-title: Mater Des – volume: 61 start-page: 495 year: 2012 end-page: 498 ident: bib36 article-title: Sense and non-sense of beam hardening correction in CT metrology publication-title: CIRP Annals – volume: 47 start-page: 670 year: 2004 end-page: 674 ident: bib71 article-title: Measurement of the parameters of the focal spot of an x-ray tube using kumakhov optics publication-title: Meas Tech – year: 2013 ident: bib26 article-title: Inter laboratory comparison on industrial computed tomography – volume: 87 start-page: 111 year: 2020 end-page: 121 ident: bib50 article-title: Automated evaluation of the surface point quality in dimensional X-ray computed tomography publication-title: TM - Tech Mess – volume: 29 year: 2018 ident: bib51 article-title: A computationally inexpensive model for estimating dimensional measurement uncertainty due to X-ray computed tomography instrument misalignments publication-title: Meas Sci Technol – volume: 52 start-page: 477 year: 2018 end-page: 483 ident: bib2 article-title: Uncertainty determination for X-ray computed tomography wear assessment of polyethylene hip joint prostheses publication-title: Precis Eng – volume: 46 start-page: 34 year: 2016 end-page: 47 ident: bib9 article-title: Surface texture metrology for metal additive manufacturing: a review publication-title: Precis Eng – year: 2010 ident: bib45 article-title: Use of reference objects for correction of measuring errors in X-ray computed tomography – volume: 23 start-page: 422 year: 2018 end-page: 432 ident: bib16 article-title: An interlaboratory comparison of X-ray computed tomography measurement for texture and dimensional characterisation of additively manufactured parts publication-title: Addit Manuf – volume: 60 start-page: 821 year: 2011 end-page: 842 ident: bib1 article-title: Computed tomography for dimensional metrology publication-title: CIRP Annals – volume: 50 year: 2022 ident: bib7 article-title: Establishment of X-ray computed tomography traceability for additively manufactured surface texture evaluation publication-title: Addit Manuf – volume: 62 start-page: 531 year: 2013 end-page: 534 ident: bib66 article-title: A 3D edge detection technique for surface extraction in computed tomography for dimensional metrology applications publication-title: CIRP Annals – volume: 20 year: 2009 ident: bib30 article-title: Testing of x-ray microtomography systems using a traceable geometrical standard publication-title: Meas Sci Technol – volume: 794 start-page: 177 year: 2015 end-page: 184 ident: bib38 article-title: A new approach for beam hardening correction based on the local spectrum distributions publication-title: Nucl Instrum Methods Phys Res Sect A Accel Spectrom Detect Assoc Equip – year: 1993 ident: bib59 article-title: Simulation reduction using the Taguchi method. Integrated realization of engineered materials, products, and associated manufacturing processes – volume: 77 start-page: 179 year: 2022 end-page: 193 ident: bib4 article-title: Performance testing of dimensional X-ray computed tomography systems publication-title: Precis Eng – year: 2012 ident: bib15 article-title: CT audit–interlaboratory comparison of computed tomography systems for dimensional metrology. Final Report – year: 2015 ident: bib42 article-title: The influence of scatter and beam hardening in X-ray computed tomography for dimensional metrology – volume: 66 start-page: 543 year: 2017 end-page: 546 ident: bib58 article-title: Topography of selectively laser melted surfaces: a comparison of different measurement methods publication-title: CIRP Annals – volume: 131 year: 2022 ident: bib28 article-title: An automated surface determination approach for computed tomography publication-title: NDT E Int – volume: 3 year: 2015 ident: bib23 article-title: Surface texture measurement for additive manufacturing publication-title: Surf Topogr Metrol Prop – volume: 24 start-page: 81 year: 1979 end-page: 106 ident: bib34 article-title: Correction for beam hardening in computed tomography publication-title: Phys Med Biol – start-page: 1 year: 2015 end-page: 8 ident: bib49 article-title: Automated detection of artefacts for computed tomography in dimensional metrology publication-title: Digital Industr. Radiol. Comput. Tomogr. – year: 2020 ident: bib43 article-title: Erosion and dilation of edges in dimensional X-ray computed tomography images – start-page: 1 year: 1998 end-page: 13 ident: bib60 article-title: Model building and validation: contributions of the Taguchi method. International System dynamics conference: international System dynamics conference – volume: 5 start-page: 308 year: 1999 end-page: 321 ident: bib65 article-title: Partitioning 3D surface meshes using watershed segmentation publication-title: IEEE Trans Visual Comput Graph – volume: 356 start-page: 295 year: 2019 end-page: 303 ident: bib48 article-title: Improved watershed analysis for segmenting contacting particles of coarse granular soils in volumetric images publication-title: Powder Technol – year: 2022 ident: bib67 article-title: Sphere fit (least squared) MATLAB central file exchange – year: 2001 ident: bib21 article-title: The measurement of surface texture using stylus instruments. Measurement good practice guide no. 37 – year: 2017 ident: bib63 article-title: Contributions to performance verification and uncertainty determination of industrial computed tomography for dimensional metrology – year: 2005 ident: bib56 article-title: Dimensionelles Messen mit Mikro-Computertomographie – start-page: 124 year: 2019 ident: bib53 article-title: Scatter corrections in X-ray computed tomography: a physics-based analysis – start-page: 31 year: 2011 end-page: 42 ident: bib31 article-title: Investigation of measuring strategies in computed tomography – volume: 43 start-page: 362 year: 2016 end-page: 367 ident: bib39 article-title: Assessment of the measurement procedure for dimensional metrology with X-ray computed tomography publication-title: Procedia CIRP – volume: 82 start-page: 8537 year: 2010 end-page: 8543 ident: bib46 article-title: Dimensional standard for micro X-ray computed tomography publication-title: Anal Chem – year: 2015 ident: bib70 article-title: Investigation of the focal spot drift in industrial cone-beam X-ray computed tomography. Digital industrial radiology and computed tomography – volume: 32 year: 2020 ident: bib11 article-title: Metrological characteristics for the calibration of surface topography measuring instruments: a review publication-title: Meas Sci Technol – volume: 27 year: 2016 ident: bib69 article-title: An experimental study on the influence of scatter and beam hardening in x-ray CT for dimensional metrology publication-title: Meas Sci Technol – volume: 77 start-page: 33 year: 2022 end-page: 39 ident: bib5 article-title: Reference object for traceability establishment in X-ray computed tomography measurements of fiber length in fiber-reinforced polymeric materials publication-title: Precis Eng – volume: 57 start-page: 16 year: 2019 end-page: 29 ident: bib54 article-title: Calibration and uncertainty estimation of non-contact coordinate measurement systems based on Kriging models publication-title: Precis Eng – volume: 60 start-page: 544 year: 2019 end-page: 569 ident: bib6 article-title: X-ray computed tomography: from medical imaging to dimensional metrology publication-title: Precis Eng – volume: 64 start-page: 249 year: 2020 end-page: 268 ident: bib13 article-title: Empirical approaches to uncertainty analysis of X-ray computed tomography measurements: a review with examples publication-title: Precis Eng – volume: 61 start-page: 82 year: 2020 end-page: 92 ident: bib57 article-title: Evaluation of the standard measurement uncertainty due to the ISO50 surface determination method for dimensional computed tomography publication-title: Precis Eng – year: 2012 ident: bib37 article-title: Beam hardening correction and its influence on the measurement accuracy and repeatability for CT dimensional metrology applications publication-title: Conf. On industrial computed tomography – volume: 66 start-page: 382 year: 2020 end-page: 391 ident: bib12 article-title: Review of the influence of noise in X-ray computed tomography measurement uncertainty publication-title: Precis Eng – volume: 64 start-page: 797 year: 2015 end-page: 813 ident: bib22 article-title: Calibration and verification of areal surface texture measuring instruments publication-title: CIRP Annals – year: 2012 ident: bib41 article-title: An overview of industrial X-ray computed tomography – volume: 66 start-page: 472 year: 2020 end-page: 481 ident: bib18 article-title: Effects of off-focal radiation on dimensional measurements in industrial cone-beam micro-focus X-ray computed tomography systems publication-title: Precis Eng – year: 2012 ident: bib47 article-title: The influence of data filtering on dimensional measurements with CT – volume: 27 year: 2016 ident: bib8 article-title: X-ray computed tomography for additive manufacturing: a review publication-title: Meas Sci Technol – year: 2016 ident: bib27 article-title: InteraqCT comparison on assemblies-final report – volume: 6 start-page: 104 year: 2016 end-page: 110 ident: bib32 article-title: Influence of surface roughness on X-ray computed tomography dimensional measurements of additive manufactured parts publication-title: Case Studies in Nondestructive Testing and Evaluation – year: 2007 ident: bib64 article-title: aRTist – analytical RT inspection simulation tool publication-title: International symposium on digital industrial radiology and computed tomography – volume: 79 start-page: 146 year: 2023 end-page: 163 ident: bib3 article-title: Assessing the effect of penetration length variations on dimensional measurements with X-ray computed tomography publication-title: Precis Eng – volume: 43 start-page: 297 year: 2016 end-page: 302 ident: bib40 article-title: Quantifying the contribution of post-processing in computed tomography measurement uncertainty publication-title: Procedia CIRP – volume: 21 start-page: 591 year: 2021 ident: bib19 article-title: Ant colony-based hyperparameter optimisation in total variation reconstruction in X-ray computed tomography publication-title: Sensors – volume: 25 year: 2014 ident: bib72 article-title: Simulation-aided investigation of beam hardening induced errors in CT dimensional metrology publication-title: Meas Sci Technol – volume: 97 start-page: 441 year: 2018 end-page: 453 ident: bib55 article-title: Comparison of surface extraction techniques performance in computed tomography for 3D complex micro-geometry dimensional measurements publication-title: Int J Adv Des Manuf Technol – volume: 85 year: 2022 ident: bib14 article-title: Review of high energy x-ray computed tomography for non-destructive dimensional metrology of large metallic advanced manufactured components publication-title: Rep Prog Phys – volume: 66 start-page: 547 year: 2017 end-page: 550 ident: bib24 article-title: Factors affecting the accuracy of areal surface texture data extraction from X-ray CT publication-title: CIRP Annals – volume: 48 start-page: 254 year: 2017 end-page: 264 ident: bib25 article-title: Areal surface texture data extraction from X-ray computed tomography reconstructions of metal additively manufactured parts publication-title: Precis Eng – volume: 38 start-page: S36 year: 2011 end-page: S49 ident: bib35 article-title: Iterative correction of beam hardening artifacts in CT publication-title: Med Phys – volume: 85 year: 2022 ident: 10.1016/j.precisioneng.2023.09.003_bib14 article-title: Review of high energy x-ray computed tomography for non-destructive dimensional metrology of large metallic advanced manufactured components publication-title: Rep Prog Phys doi: 10.1088/1361-6633/ac43f6 – volume: 77 start-page: 179 year: 2022 ident: 10.1016/j.precisioneng.2023.09.003_bib4 article-title: Performance testing of dimensional X-ray computed tomography systems publication-title: Precis Eng doi: 10.1016/j.precisioneng.2022.05.005 – volume: 66 start-page: 543 year: 2017 ident: 10.1016/j.precisioneng.2023.09.003_bib58 article-title: Topography of selectively laser melted surfaces: a comparison of different measurement methods publication-title: CIRP Annals doi: 10.1016/j.cirp.2017.04.075 – volume: 2 start-page: 1 year: 2011 ident: 10.1016/j.precisioneng.2023.09.003_bib61 article-title: Implementation of Taguchi methodology for defect reduction in manufacturing industry "A case study" publication-title: Int J Ind Eng Res Dev – year: 2008 ident: 10.1016/j.precisioneng.2023.09.003_bib44 – year: 2010 ident: 10.1016/j.precisioneng.2023.09.003_bib45 – volume: 38 start-page: S36 year: 2011 ident: 10.1016/j.precisioneng.2023.09.003_bib35 article-title: Iterative correction of beam hardening artifacts in CT publication-title: Med Phys doi: 10.1118/1.3577758 – volume: 27 year: 2016 ident: 10.1016/j.precisioneng.2023.09.003_bib20 article-title: A reference sample for investigating the stability of the imaging system of x-ray computed tomography publication-title: Meas Sci Technol doi: 10.1088/0957-0233/27/8/085004 – volume: 64 start-page: 249 year: 2020 ident: 10.1016/j.precisioneng.2023.09.003_bib13 article-title: Empirical approaches to uncertainty analysis of X-ray computed tomography measurements: a review with examples publication-title: Precis Eng doi: 10.1016/j.precisioneng.2020.03.004 – volume: 5 start-page: 308 year: 1999 ident: 10.1016/j.precisioneng.2023.09.003_bib65 article-title: Partitioning 3D surface meshes using watershed segmentation publication-title: IEEE Trans Visual Comput Graph doi: 10.1109/2945.817348 – volume: 794 start-page: 177 year: 2015 ident: 10.1016/j.precisioneng.2023.09.003_bib38 article-title: A new approach for beam hardening correction based on the local spectrum distributions publication-title: Nucl Instrum Methods Phys Res Sect A Accel Spectrom Detect Assoc Equip doi: 10.1016/j.nima.2015.05.015 – volume: 23 start-page: 422 year: 2018 ident: 10.1016/j.precisioneng.2023.09.003_bib16 article-title: An interlaboratory comparison of X-ray computed tomography measurement for texture and dimensional characterisation of additively manufactured parts publication-title: Addit Manuf – volume: 24 start-page: 81 year: 1979 ident: 10.1016/j.precisioneng.2023.09.003_bib34 article-title: Correction for beam hardening in computed tomography publication-title: Phys Med Biol doi: 10.1088/0031-9155/24/1/008 – volume: 66 start-page: 382 year: 2020 ident: 10.1016/j.precisioneng.2023.09.003_bib12 article-title: Review of the influence of noise in X-ray computed tomography measurement uncertainty publication-title: Precis Eng doi: 10.1016/j.precisioneng.2020.08.004 – year: 2013 ident: 10.1016/j.precisioneng.2023.09.003_bib26 – year: 2015 ident: 10.1016/j.precisioneng.2023.09.003_bib70 – volume: 66 start-page: 472 year: 2020 ident: 10.1016/j.precisioneng.2023.09.003_bib18 article-title: Effects of off-focal radiation on dimensional measurements in industrial cone-beam micro-focus X-ray computed tomography systems publication-title: Precis Eng doi: 10.1016/j.precisioneng.2020.08.014 – volume: 66 start-page: 547 year: 2017 ident: 10.1016/j.precisioneng.2023.09.003_bib24 article-title: Factors affecting the accuracy of areal surface texture data extraction from X-ray CT publication-title: CIRP Annals doi: 10.1016/j.cirp.2017.04.074 – volume: 3 year: 2015 ident: 10.1016/j.precisioneng.2023.09.003_bib23 article-title: Surface texture measurement for additive manufacturing publication-title: Surf Topogr Metrol Prop doi: 10.1088/2051-672X/3/2/024002 – volume: 87 start-page: 111 year: 2020 ident: 10.1016/j.precisioneng.2023.09.003_bib50 article-title: Automated evaluation of the surface point quality in dimensional X-ray computed tomography publication-title: TM - Tech Mess doi: 10.1515/teme-2019-0116 – volume: 32 year: 2020 ident: 10.1016/j.precisioneng.2023.09.003_bib11 article-title: Metrological characteristics for the calibration of surface topography measuring instruments: a review publication-title: Meas Sci Technol – volume: 25 year: 2014 ident: 10.1016/j.precisioneng.2023.09.003_bib72 article-title: Simulation-aided investigation of beam hardening induced errors in CT dimensional metrology publication-title: Meas Sci Technol doi: 10.1088/0957-0233/25/6/064014 – volume: 50 year: 2022 ident: 10.1016/j.precisioneng.2023.09.003_bib7 article-title: Establishment of X-ray computed tomography traceability for additively manufactured surface texture evaluation publication-title: Addit Manuf – volume: 29 year: 2018 ident: 10.1016/j.precisioneng.2023.09.003_bib51 article-title: A computationally inexpensive model for estimating dimensional measurement uncertainty due to X-ray computed tomography instrument misalignments publication-title: Meas Sci Technol doi: 10.1088/1361-6501/aab1a1 – year: 2020 ident: 10.1016/j.precisioneng.2023.09.003_bib43 – start-page: 337 year: 2016 ident: 10.1016/j.precisioneng.2023.09.003_bib17 article-title: Applications and systematic errors of X-ray computed tomography associated with dimensional metrology – volume: 60 start-page: 544 year: 2019 ident: 10.1016/j.precisioneng.2023.09.003_bib6 article-title: X-ray computed tomography: from medical imaging to dimensional metrology publication-title: Precis Eng doi: 10.1016/j.precisioneng.2019.06.007 – volume: 48 start-page: 254 year: 2017 ident: 10.1016/j.precisioneng.2023.09.003_bib25 article-title: Areal surface texture data extraction from X-ray computed tomography reconstructions of metal additively manufactured parts publication-title: Precis Eng doi: 10.1016/j.precisioneng.2016.12.008 – volume: 77 start-page: 33 year: 2022 ident: 10.1016/j.precisioneng.2023.09.003_bib5 article-title: Reference object for traceability establishment in X-ray computed tomography measurements of fiber length in fiber-reinforced polymeric materials publication-title: Precis Eng doi: 10.1016/j.precisioneng.2022.05.003 – year: 2012 ident: 10.1016/j.precisioneng.2023.09.003_bib41 – start-page: 1 year: 2015 ident: 10.1016/j.precisioneng.2023.09.003_bib49 article-title: Automated detection of artefacts for computed tomography in dimensional metrology publication-title: Digital Industr. Radiol. Comput. Tomogr. – year: 2016 ident: 10.1016/j.precisioneng.2023.09.003_bib27 – volume: 46 start-page: 34 year: 2016 ident: 10.1016/j.precisioneng.2023.09.003_bib9 article-title: Surface texture metrology for metal additive manufacturing: a review publication-title: Precis Eng doi: 10.1016/j.precisioneng.2016.06.001 – volume: 64 start-page: 797 year: 2015 ident: 10.1016/j.precisioneng.2023.09.003_bib22 article-title: Calibration and verification of areal surface texture measuring instruments publication-title: CIRP Annals doi: 10.1016/j.cirp.2015.05.010 – year: 2007 ident: 10.1016/j.precisioneng.2023.09.003_bib64 article-title: aRTist – analytical RT inspection simulation tool – start-page: 1 year: 1998 ident: 10.1016/j.precisioneng.2023.09.003_bib60 – volume: 27 year: 2016 ident: 10.1016/j.precisioneng.2023.09.003_bib69 article-title: An experimental study on the influence of scatter and beam hardening in x-ray CT for dimensional metrology publication-title: Meas Sci Technol doi: 10.1088/0957-0233/27/1/015007 – volume: 131 year: 2022 ident: 10.1016/j.precisioneng.2023.09.003_bib28 article-title: An automated surface determination approach for computed tomography publication-title: NDT E Int doi: 10.1016/j.ndteint.2022.102697 – volume: 79 start-page: 146 year: 2023 ident: 10.1016/j.precisioneng.2023.09.003_bib3 article-title: Assessing the effect of penetration length variations on dimensional measurements with X-ray computed tomography publication-title: Precis Eng doi: 10.1016/j.precisioneng.2022.10.001 – year: 2012 ident: 10.1016/j.precisioneng.2023.09.003_bib15 – volume: 57 start-page: 16 year: 2019 ident: 10.1016/j.precisioneng.2023.09.003_bib54 article-title: Calibration and uncertainty estimation of non-contact coordinate measurement systems based on Kriging models publication-title: Precis Eng doi: 10.1016/j.precisioneng.2019.02.004 – year: 2016 ident: 10.1016/j.precisioneng.2023.09.003_bib68 article-title: VGStudio MAX 3.0 publication-title: Reference Manual – volume: 356 start-page: 295 year: 2019 ident: 10.1016/j.precisioneng.2023.09.003_bib48 article-title: Improved watershed analysis for segmenting contacting particles of coarse granular soils in volumetric images publication-title: Powder Technol doi: 10.1016/j.powtec.2019.08.028 – start-page: 31 year: 2011 ident: 10.1016/j.precisioneng.2023.09.003_bib31 – year: 2012 ident: 10.1016/j.precisioneng.2023.09.003_bib37 article-title: Beam hardening correction and its influence on the measurement accuracy and repeatability for CT dimensional metrology applications – year: 2015 ident: 10.1016/j.precisioneng.2023.09.003_bib42 – year: 2005 ident: 10.1016/j.precisioneng.2023.09.003_bib56 – volume: 21 start-page: 591 year: 2021 ident: 10.1016/j.precisioneng.2023.09.003_bib19 article-title: Ant colony-based hyperparameter optimisation in total variation reconstruction in X-ray computed tomography publication-title: Sensors doi: 10.3390/s21020591 – volume: 82 start-page: 8537 year: 2010 ident: 10.1016/j.precisioneng.2023.09.003_bib46 article-title: Dimensional standard for micro X-ray computed tomography publication-title: Anal Chem doi: 10.1021/ac101522q – volume: 27 year: 2016 ident: 10.1016/j.precisioneng.2023.09.003_bib8 article-title: X-ray computed tomography for additive manufacturing: a review publication-title: Meas Sci Technol doi: 10.1088/0957-0233/27/7/072001 – volume: 43 start-page: 297 year: 2016 ident: 10.1016/j.precisioneng.2023.09.003_bib40 article-title: Quantifying the contribution of post-processing in computed tomography measurement uncertainty publication-title: Procedia CIRP doi: 10.1016/j.procir.2016.02.123 – volume: 47 start-page: 670 year: 2004 ident: 10.1016/j.precisioneng.2023.09.003_bib71 article-title: Measurement of the parameters of the focal spot of an x-ray tube using kumakhov optics publication-title: Meas Tech doi: 10.1023/B:METE.0000043654.30424.3f – volume: 61 start-page: 82 year: 2020 ident: 10.1016/j.precisioneng.2023.09.003_bib57 article-title: Evaluation of the standard measurement uncertainty due to the ISO50 surface determination method for dimensional computed tomography publication-title: Precis Eng doi: 10.1016/j.precisioneng.2019.10.004 – volume: 52 start-page: 477 year: 2018 ident: 10.1016/j.precisioneng.2023.09.003_bib2 article-title: Uncertainty determination for X-ray computed tomography wear assessment of polyethylene hip joint prostheses publication-title: Precis Eng doi: 10.1016/j.precisioneng.2018.02.009 – volume: 97 start-page: 441 year: 2018 ident: 10.1016/j.precisioneng.2023.09.003_bib55 article-title: Comparison of surface extraction techniques performance in computed tomography for 3D complex micro-geometry dimensional measurements publication-title: Int J Adv Des Manuf Technol doi: 10.1007/s00170-018-1950-9 – volume: 20 year: 2009 ident: 10.1016/j.precisioneng.2023.09.003_bib30 article-title: Testing of x-ray microtomography systems using a traceable geometrical standard publication-title: Meas Sci Technol doi: 10.1088/0957-0233/20/8/084021 – volume: 60 start-page: 821 year: 2011 ident: 10.1016/j.precisioneng.2023.09.003_bib1 article-title: Computed tomography for dimensional metrology publication-title: CIRP Annals doi: 10.1016/j.cirp.2011.05.006 – year: 2012 ident: 10.1016/j.precisioneng.2023.09.003_bib47 – volume: 187 year: 2020 ident: 10.1016/j.precisioneng.2023.09.003_bib10 article-title: Effects of defects on mechanical properties in metal additive manufacturing: a review focusing on X-ray tomography insights publication-title: Mater Des doi: 10.1016/j.matdes.2019.108385 – volume: 28 year: 2017 ident: 10.1016/j.precisioneng.2023.09.003_bib52 article-title: Two-spheres method for evaluating the metrological structural resolution in dimensional computed tomography publication-title: Meas Sci Technol doi: 10.1088/1361-6501/aa85b7 – year: 2022 ident: 10.1016/j.precisioneng.2023.09.003_bib67 – year: 1993 ident: 10.1016/j.precisioneng.2023.09.003_bib59 – volume: 23 start-page: 65 year: 2015 ident: 10.1016/j.precisioneng.2023.09.003_bib33 article-title: A simulation-based study on the influence of beam hardening in X-ray computed tomography for dimensional metrology publication-title: J X Ray Sci Technol doi: 10.3233/XST-140471 – start-page: 124 year: 2019 ident: 10.1016/j.precisioneng.2023.09.003_bib53 – volume: 23 year: 2012 ident: 10.1016/j.precisioneng.2023.09.003_bib62 article-title: Physical characterization and performance evaluation of an x-ray micro-computed tomography system for dimensional metrology applications publication-title: Meas Sci Technol doi: 10.1088/0957-0233/23/8/085404 – volume: 6 start-page: 104 year: 2016 ident: 10.1016/j.precisioneng.2023.09.003_bib32 article-title: Influence of surface roughness on X-ray computed tomography dimensional measurements of additive manufactured parts publication-title: Case Studies in Nondestructive Testing and Evaluation doi: 10.1016/j.csndt.2016.05.005 – volume: 28 year: 2017 ident: 10.1016/j.precisioneng.2023.09.003_bib29 article-title: Simulating the influence of scatter and beam hardening in dimensional computed tomography publication-title: Meas Sci Technol doi: 10.1088/1361-6501/aa80b2 – volume: 61 start-page: 495 year: 2012 ident: 10.1016/j.precisioneng.2023.09.003_bib36 article-title: Sense and non-sense of beam hardening correction in CT metrology publication-title: CIRP Annals doi: 10.1016/j.cirp.2012.03.013 – year: 2001 ident: 10.1016/j.precisioneng.2023.09.003_bib21 – volume: 43 start-page: 362 year: 2016 ident: 10.1016/j.precisioneng.2023.09.003_bib39 article-title: Assessment of the measurement procedure for dimensional metrology with X-ray computed tomography publication-title: Procedia CIRP doi: 10.1016/j.procir.2016.02.018 – year: 2017 ident: 10.1016/j.precisioneng.2023.09.003_bib63 – volume: 62 start-page: 531 year: 2013 ident: 10.1016/j.precisioneng.2023.09.003_bib66 article-title: A 3D edge detection technique for surface extraction in computed tomography for dimensional metrology applications publication-title: CIRP Annals doi: 10.1016/j.cirp.2013.03.016 |
| SSID | ssj0007804 |
| Score | 2.411214 |
| Snippet | Surface determination plays an important role in XCT bi-directional length measurement, however, its effect on the measurement results is often overlooked or... |
| SourceID | crossref elsevier |
| SourceType | Enrichment Source Index Database Publisher |
| StartPage | 40 |
| Title | Surface determination algorithm for accurate XCT bidirectional length measurements |
| URI | https://dx.doi.org/10.1016/j.precisioneng.2023.09.003 |
| Volume | 85 |
| WOSCitedRecordID | wos001084462900001&url=https%3A%2F%2Fcvtisr.summon.serialssolutions.com%2F%23%21%2Fsearch%3Fho%3Df%26include.ft.matches%3Dt%26l%3Dnull%26q%3D |
| hasFullText | 1 |
| inHoldings | 1 |
| isFullTextHit | |
| isPrint | |
| journalDatabaseRights | – providerCode: PRVESC databaseName: Elsevier SD Freedom Collection Journals 2021 customDbUrl: eissn: 1873-2372 dateEnd: 99991231 omitProxy: false ssIdentifier: ssj0007804 issn: 0141-6359 databaseCode: AIEXJ dateStart: 19950101 isFulltext: true titleUrlDefault: https://www.sciencedirect.com providerName: Elsevier |
| link | http://cvtisr.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwtV1La9wwEBZL0kN7KH3S9IUOvRkHr2VZ9qGHsKQvSgjNlvpmZFlOvGzcxWuH9N93ZEm20gfdFnoRi1hpbc23M6PR6BuEXpUBA6ciFX7EWACNCPyijBNf8qiaE3DQYyqGYhPs5CTJsvR0NtvYuzBXa9Y0yfV1uvmvooY-ELa6OvsX4h4nhQ74DEKHFsQO7U6CP-vbigt1Hcokuuha4Ovzr23dXVzqtEkhesUR4WWLpVfU2q7poKCqrNJdeJdT7HDrOrCnrSnK48mJyXBUHSb4nNX9t36C3Vk_qLYvslk5vW_rfisG13Wx5n1Z997HQzcGEUZODMKGJec-uC6pq1cT6ihGzclkTKzm2PxJees4wgpMhy0v1JwfqvLuAxNtQCaTZY_pf7BkY36hTV1b5e5cuZorD9J8oIfdDxlNQQ_uH70_zj6M1lsRMum0V_1Glqh2yAn83ZP92qlxHJXlPXTX7DDwkUbGfTSTzQN0x-GdfIg-GYzgGxjBI0YwYARbjGDACL6BEawxgl2MPEKf3xwvF-98U1zDF1EUdn4ZS0YKQgsu4lKEnKgTZVqFtCwjOS_A0ZwnUkpKShaKMkkqylIJzlwFO3TCOSOP0V4DC_EEYR7B11mU8DCuoiSmoBYIE0TCZjktOA0PUGpXJxeGeV4VQFnnf5bTASLj2I3mX9lp1GsrhNx4knqVcsDaDuOf_tOvPkO3pz_Hc7TXtb18gW6Jq67eti8N0L4DpEOhYg |
| linkProvider | Elsevier |
| openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Surface+determination+algorithm+for+accurate+XCT+bidirectional+length+measurements&rft.jtitle=Precision+engineering&rft.au=Yang%2C+Xiuyuan&rft.au=Sun%2C+Wenjuan&rft.au=Giusca%2C+Claudiu+L.&rft.date=2024-01-01&rft.issn=0141-6359&rft.volume=85&rft.spage=40&rft.epage=47&rft_id=info:doi/10.1016%2Fj.precisioneng.2023.09.003&rft.externalDBID=n%2Fa&rft.externalDocID=10_1016_j_precisioneng_2023_09_003 |
| thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0141-6359&client=summon |
| thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0141-6359&client=summon |
| thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0141-6359&client=summon |