Sealing Behavior in Transcatheter Bicuspid and Tricuspid Aortic Valves Replacement Through Patient-Specific Computational Modeling

Background: Patient-specific computer simulation of transcatheter aortic valve replacement (TAVR) can provide unique insights in device-patient interaction. Aims: This study was to compare transcatheter aortic valve sealing behavior in patients with bicuspid aortic valves (BAV) and tricuspid aortic...

Full description

Saved in:
Bibliographic Details
Published in:Frontiers in cardiovascular medicine Vol. 8; p. 732784
Main Authors: Liu, Xianbao, Fan, Jiaqi, Mortier, Peter, He, Yuxin, Zhu, Qifeng, Guo, Yuchao, Lin, Xinping, Li, Huajun, Jiang, Jubo, Rocatello, Giorgia, Oliveira, Vanda, Dezutter, Tim, Sondergaard, Lars, Wang, Jian'an
Format: Journal Article
Language:English
Published: Frontiers Media S.A 11.10.2021
Subjects:
ISSN:2297-055X, 2297-055X
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Background: Patient-specific computer simulation of transcatheter aortic valve replacement (TAVR) can provide unique insights in device-patient interaction. Aims: This study was to compare transcatheter aortic valve sealing behavior in patients with bicuspid aortic valves (BAV) and tricuspid aortic valves (TAV) through patient-specific computational modeling. Methods: Patient-specific computer simulation was retrospectively performed with FEops HEARTguide for TAVR patients. Simulation output was compared with postprocedural computed tomography and echocardiography to validate the accuracy. Skirt malapposition was defined by a distance larger than 1 mm based on the predicted device-patient interaction by quantifying the distance between the transcatheter heart valve (THV) skirt and the surrounding anatomical regions. Results: In total, 43 patients were included in the study. Predicted and observed THV frame deformation showed good correlation ( R 2 ≥ 0.90) for all analyzed measurements (maximum diameter, minimum diameter, area, and perimeter). The amount of predicted THV skirt malapposition was strongly linked with the echocardiographic grading of paravalvular leakage (PVL). More THV skirt malapposition was observed for BAV cases when compared to TAV cases (22.7 vs. 15.5%, p < 0.05). A detailed analysis of skirt malapposition showed a higher degree of malapposition in the interleaflet triangles section for BAV cases as compared to TAV patients (11.1 vs. 5.8%, p < 0.05). Conclusions: Patient-specific computer simulation of TAVR can accurately predict the behavior of the Venus A-valve. BAV patients are associated with more malapposition of the THV skirt as compared to TAV patients, and this is mainly driven by more malapposition in the interleaflet triangle region.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
Edited by: Peter Zilla, University of Cape Town, South Africa
Reviewed by: Huseyin Cagatay Yalcin, Qatar University, Qatar; Philippe Sucosky, Kennesaw State University, United States
These authors have contributed equally to this work
This article was submitted to Heart Valve Disease, a section of the journal Frontiers in Cardiovascular Medicine
ISSN:2297-055X
2297-055X
DOI:10.3389/fcvm.2021.732784