A novel multichannel sparse convolutional autoencoder for electrocardiogram signal compression
Electrocardiogram (ECG) signal compression is paramount in continuously monitoring cardiac patients, as it reduces data storage and transmission costs. Deep neural networks, particularly autoencoders, offer significant potential for compressing ECG signals by mapping them to lower-dimensional spaces...
Gespeichert in:
| Veröffentlicht in: | Journal of electrocardiology Jg. 93; S. 154125 |
|---|---|
| Hauptverfasser: | , , , |
| Format: | Journal Article |
| Sprache: | Englisch |
| Veröffentlicht: |
United States
Elsevier Inc
01.11.2025
|
| Schlagworte: | |
| ISSN: | 0022-0736, 1532-8430, 1532-8430 |
| Online-Zugang: | Volltext |
| Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
| Zusammenfassung: | Electrocardiogram (ECG) signal compression is paramount in continuously monitoring cardiac patients, as it reduces data storage and transmission costs. Deep neural networks, particularly autoencoders, offer significant potential for compressing ECG signals by mapping them to lower-dimensional spaces. This paper presents a novel multichannel convolutional autoencoder model designed to compress ECG signals efficiently. The proposed approach encodes the ECG signal into a four-channel lower-dimensional space using a convolutional encoder, which is subsequently reconstructed by a deconvolutional decoder. Unlike traditional autoencoder-based methods, the first channel in the model remains unconstrained, while increasing levels of sparsity constraints are imposed on the remaining channels. Different quantization levels are applied to each channel to optimize compression further, reflecting the varying numerical ranges caused by the sparsity constraints. The quantized channels are then encoded using Huffman coding, resulting in a higher compression ratio. The model’s effectiveness is evaluated on a popular benchmark dataset, using normalized percent root mean square difference (PRDN) error and compression ratio as performance metrics. The proposed method achieves an average compression ratio of 20.23:1, with an average PRDN error of 9.86%, demonstrating its capability to compress ECG signals efficiently while maintaining reconstruction accuracy.
•A novel multichannel CNN-autoencoder efficiently compresses ECG signals.•Channel-variant sparsity is introduced to boost data compression rates.•Channel-specific quantization and Huffman coding ensure high CR, minimal error.•Achieves 20.23:1 CR with 9.86% PRDN on benchmark ECG datasets. |
|---|---|
| Bibliographie: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
| ISSN: | 0022-0736 1532-8430 1532-8430 |
| DOI: | 10.1016/j.jelectrocard.2025.154125 |