A New On-Line Visual Ferrograph

An on-line visual ferrograph (OLVF) characterized by direct reading and on-line analysis was developed based on magnetic deposition and image analysis. A digital sensor was integrated with a CMOS image sensor to obtain images of deposited wear debris under illumination conditions. An electromagnetic...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Tribology transactions Jg. 52; H. 5; S. 623 - 631
Hauptverfasser: WU, T. H., MAO, J. H., WANG, J. T., WU, J. Y., XIE, Y. B.
Format: Journal Article
Sprache:Englisch
Veröffentlicht: Philadelphia, PA Taylor & Francis Group 01.09.2009
Taylor & Francis
Taylor & Francis Inc
Schlagworte:
ISSN:1040-2004, 1547-397X
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:An on-line visual ferrograph (OLVF) characterized by direct reading and on-line analysis was developed based on magnetic deposition and image analysis. A digital sensor was integrated with a CMOS image sensor to obtain images of deposited wear debris under illumination conditions. An electromagnetic instrument was designed to deposit the wear debris flowing through an oil flow channel. The oil flow channel, fixed on the electromagnet, was arranged parallel to the magnetic flux in the air gap between two electromagnet poles. The deposition effect on wear debris was analyzed theoretically. The result shows that the wear debris in different sizes can be deposited in the same zone by controlling the oil flow rate and magnet field intensity. Corresponding application software for image sampling and processing was developed. An index of relative wear debris concentration, IPCA (Index of Particle Coverage Area), is given as an output in addition to wear debris images. Finally, two kinds of experiments were specified to assess the effect and validity of the OLVF. The results show that the OLVF has effective deposition and identification for both relatively large and small wear debris with rational control parameters. The validity examinations with the commercial particle quantifier (PQ) and direct reading ferrograph (DR) show that the OLVF has an approaching trend to the reference instruments in both heavily and lightly contaminated oil.
Bibliographie:SourceType-Scholarly Journals-1
ObjectType-Feature-1
content type line 14
ObjectType-Article-2
content type line 23
ISSN:1040-2004
1547-397X
DOI:10.1080/10402000902825762