Automatic Tracking of Surgical Instruments with a Continuum Laparoscope Using Data‐Driven Control in Robotic Surgery

In existing surgery process, surgeons need to manually adjust the laparoscopes to provide a better field of view (FOV) during operation, which may distract surgeons and slow down the surgery process. Herein, a data‐driven control method that uses a continuum laparoscope to adjust the FOV by tracking...

Celý popis

Uložené v:
Podrobná bibliografia
Vydané v:Advanced intelligent systems Ročník 5; číslo 2
Hlavní autori: Kong, Xiaowen, Mo, Hangjie, Dong, Erbao, Liu, Yunhui, Sun, Dong
Médium: Journal Article
Jazyk:English
Vydavateľské údaje: Weinheim John Wiley & Sons, Inc 01.02.2023
Wiley
Predmet:
ISSN:2640-4567, 2640-4567
On-line prístup:Získať plný text
Tagy: Pridať tag
Žiadne tagy, Buďte prvý, kto otaguje tento záznam!
Popis
Shrnutí:In existing surgery process, surgeons need to manually adjust the laparoscopes to provide a better field of view (FOV) during operation, which may distract surgeons and slow down the surgery process. Herein, a data‐driven control method that uses a continuum laparoscope to adjust the FOV by tracking the surgical instruments is presented. A Koopman‐based system identification method is first applied to linearize the nonlinear system. Shifted Chebyshev polynomials are used to construct observation functions that transfer low‐dimension observations to high‐dimension ones. The Koopman operator is approximated using a finite‐dimensional estimation method. An optimal controller is further developed according to the trained linear dynamic model. Furthermore, a learning‐based pose estimation framework is designed to detect keypoints on surgical instruments and provides visual feedback for the control system. Compared with other detection methods, the proposed scheme achieves a higher detection precision and provides more optional keypoints for tracking. Simulation and experiments validate the feasibility of the proposed control method. Experimental results show that the proposed method can automatically adjust the field of continuum laparoscope by tracking surgical instruments in real time and satisfy the clinical requirements. Herein, a data‐driven control method for a continuum laparoscope system to automatically adjust the field of view in robotic surgery is presented. Detection‐based pose estimation method provides higher accuracy for visual feedback. Experimental results show the feasibility of the proposed data‐driven control method to adjust the field of continuum laparoscope automatically and can also satisfy the clinical requirements.
Bibliografia:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
ISSN:2640-4567
2640-4567
DOI:10.1002/aisy.202200188