PCA-Based Multi-Wavelength Photoplethysmography Algorithm for Cuffless Blood Pressure Measurement on Elderly Subjects

The prevalence of hypertension has made blood pressure (BP) measurement one of the most wanted functions in wearable devices for convenient and frequent self-assessment of health conditions. The widely adopted principle for cuffless BP monitoring is based on arterial pulse transit time (PTT), which...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE journal of biomedical and health informatics Jg. 25; H. 3; S. 663 - 673
Hauptverfasser: Liu, Jing, Qiu, Shirong, Luo, Ningqi, Lau, Sze-Kei, Yu, Hui, Kwok, Timothy, Zhang, Yuan-Ting, Zhao, Ni
Format: Journal Article
Sprache:Englisch
Veröffentlicht: United States IEEE 01.03.2021
The Institute of Electrical and Electronics Engineers, Inc. (IEEE)
Schlagworte:
ISSN:2168-2194, 2168-2208, 2168-2208
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Abstract The prevalence of hypertension has made blood pressure (BP) measurement one of the most wanted functions in wearable devices for convenient and frequent self-assessment of health conditions. The widely adopted principle for cuffless BP monitoring is based on arterial pulse transit time (PTT), which is measured with electrocardiography and photoplethysmography (PPG). To achieve cuffless BP monitoring with more compact wearable electronics, we have previously conceived a multi-wavelength PPG (MWPPG) strategy to perform BP estimation from arteriolar PTT, requiring only a single sensing node. However, challenges remain in decoding the compounded MWPPG signals consisting of both heterogeneous physiological information and motion artifact (MA). In this work, we proposed an improved MWPPG algorithm based on principal component analysis (PCA) which matches the statistical decomposition results with the arterial pulse and capillary pulse. The arteriolar PTT is calculated accordingly as the phase shift based on the entire waveforms, instead of local peak lag time, to enhance the feature robustness. Meanwhile, the PCA-derived MA component is employed to identify and exclude the MA-contaminated segments. To evaluate the new algorithm, we performed a comparative experiment (N = 22) with a cuffless MWPPG measurement device and used double-tube auscultatory BP measurement as a reference. The results demonstrate the accuracy improvement enabled by the PCA-based operations on MWPPG signals, yielding errors of 1.44 ± 6.89 mmHg for systolic blood pressure and −1.00 ± 6.71 mm Hg for diastolic blood pressure. In conclusion, the proposed PCA-based method can improve the performance of MWPPG in wearable medical devices for cuffless BP measurement.
AbstractList The prevalence of hypertension has made blood pressure (BP) measurement one of the most wanted functions in wearable devices for convenient and frequent self-assessment of health conditions. The widely adopted principle for cuffless BP monitoring is based on arterial pulse transit time (PTT), which is measured with electrocardiography and photoplethysmography (PPG). To achieve cuffless BP monitoring with more compact wearable electronics, we have previously conceived a multi-wavelength PPG (MWPPG) strategy to perform BP estimation from arteriolar PTT, requiring only a single sensing node. However, challenges remain in decoding the compounded MWPPG signals consisting of both heterogeneous physiological information and motion artifact (MA). In this work, we proposed an improved MWPPG algorithm based on principal component analysis (PCA) which matches the statistical decomposition results with the arterial pulse and capillary pulse. The arteriolar PTT is calculated accordingly as the phase shift based on the entire waveforms, instead of local peak lag time, to enhance the feature robustness. Meanwhile, the PCA-derived MA component is employed to identify and exclude the MA-contaminated segments. To evaluate the new algorithm, we performed a comparative experiment (N = 22) with a cuffless MWPPG measurement device and used double-tube auscultatory BP measurement as a reference. The results demonstrate the accuracy improvement enabled by the PCA-based operations on MWPPG signals, yielding errors of 1.44 ± 6.89 mmHg for systolic blood pressure and −1.00 ± 6.71 mm Hg for diastolic blood pressure. In conclusion, the proposed PCA-based method can improve the performance of MWPPG in wearable medical devices for cuffless BP measurement.
The prevalence of hypertension has made blood pressure (BP) measurement one of the most wanted functions in wearable devices for convenient and frequent self-assessment of health conditions. The widely adopted principle for cuffless BP monitoring is based on arterial pulse transit time (PTT), which is measured with electrocardiography and photoplethysmography (PPG). To achieve cuffless BP monitoring with more compact wearable electronics, we have previously conceived a multi-wavelength PPG (MWPPG) strategy to perform BP estimation from arteriolar PTT, requiring only a single sensing node. However, challenges remain in decoding the compounded MWPPG signals consisting of both heterogeneous physiological information and motion artifact (MA). In this work, we proposed an improved MWPPG algorithm based on principal component analysis (PCA) which matches the statistical decomposition results with the arterial pulse and capillary pulse. The arteriolar PTT is calculated accordingly as the phase shift based on the entire waveforms, instead of local peak lag time, to enhance the feature robustness. Meanwhile, the PCA-derived MA component is employed to identify and exclude the MA-contaminated segments. To evaluate the new algorithm, we performed a comparative experiment (N = 22) with a cuffless MWPPG measurement device and used double-tube auscultatory BP measurement as a reference. The results demonstrate the accuracy improvement enabled by the PCA-based operations on MWPPG signals, yielding errors of 1.44 ± 6.89 mmHg for systolic blood pressure and -1.00 ± 6.71 mm Hg for diastolic blood pressure. In conclusion, the proposed PCA-based method can improve the performance of MWPPG in wearable medical devices for cuffless BP measurement.
The prevalence of hypertension has made blood pressure (BP) measurement one of the most wanted functions in wearable devices for convenient and frequent self-assessment of health conditions. The widely adopted principle for cuffless BP monitoring is based on arterial pulse transit time (PTT), which is measured with electrocardiography and photoplethysmography (PPG). To achieve cuffless BP monitoring with more compact wearable electronics, we have previously conceived a multi-wavelength PPG (MWPPG) strategy to perform BP estimation from arteriolar PTT, requiring only a single sensing node. However, challenges remain in decoding the compounded MWPPG signals consisting of both heterogeneous physiological information and motion artifact (MA). In this work, we proposed an improved MWPPG algorithm based on principal component analysis (PCA) which matches the statistical decomposition results with the arterial pulse and capillary pulse. The arteriolar PTT is calculated accordingly as the phase shift based on the entire waveforms, instead of local peak lag time, to enhance the feature robustness. Meanwhile, the PCA-derived MA component is employed to identify and exclude the MA-contaminated segments. To evaluate the new algorithm, we performed a comparative experiment (N = 22) with a cuffless MWPPG measurement device and used double-tube auscultatory BP measurement as a reference. The results demonstrate the accuracy improvement enabled by the PCA-based operations on MWPPG signals, yielding errors of 1.44 ± 6.89 mmHg for systolic blood pressure and -1.00 ± 6.71 mm Hg for diastolic blood pressure. In conclusion, the proposed PCA-based method can improve the performance of MWPPG in wearable medical devices for cuffless BP measurement.The prevalence of hypertension has made blood pressure (BP) measurement one of the most wanted functions in wearable devices for convenient and frequent self-assessment of health conditions. The widely adopted principle for cuffless BP monitoring is based on arterial pulse transit time (PTT), which is measured with electrocardiography and photoplethysmography (PPG). To achieve cuffless BP monitoring with more compact wearable electronics, we have previously conceived a multi-wavelength PPG (MWPPG) strategy to perform BP estimation from arteriolar PTT, requiring only a single sensing node. However, challenges remain in decoding the compounded MWPPG signals consisting of both heterogeneous physiological information and motion artifact (MA). In this work, we proposed an improved MWPPG algorithm based on principal component analysis (PCA) which matches the statistical decomposition results with the arterial pulse and capillary pulse. The arteriolar PTT is calculated accordingly as the phase shift based on the entire waveforms, instead of local peak lag time, to enhance the feature robustness. Meanwhile, the PCA-derived MA component is employed to identify and exclude the MA-contaminated segments. To evaluate the new algorithm, we performed a comparative experiment (N = 22) with a cuffless MWPPG measurement device and used double-tube auscultatory BP measurement as a reference. The results demonstrate the accuracy improvement enabled by the PCA-based operations on MWPPG signals, yielding errors of 1.44 ± 6.89 mmHg for systolic blood pressure and -1.00 ± 6.71 mm Hg for diastolic blood pressure. In conclusion, the proposed PCA-based method can improve the performance of MWPPG in wearable medical devices for cuffless BP measurement.
Author Yu, Hui
Zhao, Ni
Liu, Jing
Luo, Ningqi
Kwok, Timothy
Lau, Sze-Kei
Zhang, Yuan-Ting
Qiu, Shirong
Author_xml – sequence: 1
  givenname: Jing
  orcidid: 0000-0003-3088-1673
  surname: Liu
  fullname: Liu, Jing
  email: 93liujing@gmail.com
  organization: Department of Electronic Engineering, The Chinese University of Hong Kong, Hong Kong, China
– sequence: 2
  givenname: Shirong
  surname: Qiu
  fullname: Qiu, Shirong
  email: srqiu@link.cuhk.edu.hk
  organization: Department of Electronic Engineering, The Chinese University of Hong Kong, Hong Kong, China
– sequence: 3
  givenname: Ningqi
  surname: Luo
  fullname: Luo, Ningqi
  email: nqluo@cuhk.edu.hk
  organization: Department of Electronic Engineering, The Chinese University of Hong Kong, Hong Kong, China
– sequence: 4
  givenname: Sze-Kei
  surname: Lau
  fullname: Lau, Sze-Kei
  email: jessicalau@cuhk.edu.hk
  organization: Department of Electronic Engineering, The Chinese University of Hong Kong, Hong Kong, China
– sequence: 5
  givenname: Hui
  surname: Yu
  fullname: Yu, Hui
  email: yuhui861202@gmail.com
  organization: Department of Electronic Engineering, The Chinese University of Hong Kong, Hong Kong, China
– sequence: 6
  givenname: Timothy
  surname: Kwok
  fullname: Kwok, Timothy
  email: tkwok@cuhk.edu.hk
  organization: Department of Medicine and Therapeutics, The Chinese University of Hong Kong, Hong Kong, China
– sequence: 7
  givenname: Yuan-Ting
  orcidid: 0000-0003-4150-5470
  surname: Zhang
  fullname: Zhang, Yuan-Ting
  email: yt.zhang@cityu.edu.hk
  organization: Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
– sequence: 8
  givenname: Ni
  orcidid: 0000-0002-1536-8516
  surname: Zhao
  fullname: Zhao, Ni
  email: nzhao@cuhk.edu.hk
  organization: Department of Electronic Engineering, The Chinese University of Hong Kong, Hong Kong, China
BackLink https://www.ncbi.nlm.nih.gov/pubmed/32750946$$D View this record in MEDLINE/PubMed
BookMark eNp9kcFq3DAQhkVJadI0D1AKRdBLLt5Ksi1Lx90laVISutCWHoUsj9deZGsryYV9-8rsbg85dC4zDN8_zMz_Fl2MbgSE3lOyoJTIz19XD48LRhhZ5IQUJGev0BWjXGSMEXFxrqksLtFNCDuSQqSW5G_QZc6qksiCX6Fps15mKx2gwc-TjX32S_8BC-M2dnjTuej2FmJ3CIPber3vDnhpt873sRtw6zxeT21rIQS8ss41eONTPXnAz6DnPMAYsRvxnW3A2wP-PtU7MDG8Q69bbQPcnPI1-nl_92P9kD19-_K4Xj5lpqBlzEReCTDSGM5lWecN5byoja6FELIUBdct1ISUpSm11gVwbuZ_tNowLXkLNL9Gt8e5e-9-TxCiGvpgwFo9gpuCYkVOOGesLBP66QW6c5Mf03aJkkJUVUFm6uOJmuoBGrX3_aD9QZ0fmoDqCBjvQvDQKtNHHXs3Rq97qyhRs3tqdk_N26qTe0lJXyjPw_-n-XDU9ADwj5c0XZST_C8XgKTk
CODEN IJBHA9
CitedBy_id crossref_primary_10_1016_j_mrl_2025_200241
crossref_primary_10_1109_JSEN_2024_3438773
crossref_primary_10_1109_RBME_2021_3121476
crossref_primary_10_1109_JBHI_2022_3220967
crossref_primary_10_1109_JBHI_2023_3266349
crossref_primary_10_1007_s13246_023_01293_w
crossref_primary_10_1109_JBHI_2023_3265857
crossref_primary_10_1002_btm2_10359
crossref_primary_10_1016_j_saa_2023_123181
crossref_primary_10_1109_TCE_2023_3316514
crossref_primary_10_1109_TIM_2021_3122182
crossref_primary_10_3390_bioengineering11040306
crossref_primary_10_1002_advs_202310022
crossref_primary_10_1016_j_bspc_2022_103616
crossref_primary_10_32604_cmc_2022_020493
crossref_primary_10_1109_JBHI_2022_3167059
crossref_primary_10_1109_JBHI_2024_3499834
crossref_primary_10_3390_electronics12132923
crossref_primary_10_1016_j_measurement_2024_115446
crossref_primary_10_3390_s21217207
crossref_primary_10_1007_s10462_022_10353_8
crossref_primary_10_3390_app15137609
crossref_primary_10_1002_btm2_10502
crossref_primary_10_1088_1361_6579_ac7841
crossref_primary_10_1088_1361_6579_adae50
crossref_primary_10_1007_s11760_025_04353_8
crossref_primary_10_1021_acs_chemrev_4c00763
crossref_primary_10_1088_1361_6579_acead2
crossref_primary_10_1109_JBHI_2021_3061793
crossref_primary_10_1002_advs_202415215
crossref_primary_10_1109_TBME_2024_3434344
crossref_primary_10_1145_3731600
crossref_primary_10_1016_j_asr_2023_10_024
crossref_primary_10_1109_ACCESS_2024_3488595
crossref_primary_10_3389_fnins_2022_1047070
crossref_primary_10_1109_TIM_2023_3279448
crossref_primary_10_1038_s41551_023_01098_y
crossref_primary_10_1038_s44222_024_00175_4
crossref_primary_10_3390_s23156947
Cites_doi 10.1364/BOE.7.004313
10.1145/3130905
10.1109/IEMBS.2003.1280811
10.1038/s41598-017-11507-3
10.1109/TBME.2015.2441951
10.1109/EMBC.2016.7590777
10.1007/978-1-4020-8486-7
10.1016/j.sder.2008.08.003
10.1007/s10103-017-2317-4
10.1109/JBHI.2016.2620995
10.1016/j.jash.2015.09.011
10.1161/01.CIR.36.6.805
10.1016/S0140-6736(12)61766-8
10.1109/TBME.2018.2874957
ContentType Journal Article
Copyright Copyright The Institute of Electrical and Electronics Engineers, Inc. (IEEE) 2021
Copyright_xml – notice: Copyright The Institute of Electrical and Electronics Engineers, Inc. (IEEE) 2021
DBID 97E
RIA
RIE
AAYXX
CITATION
NPM
7QF
7QO
7QQ
7SC
7SE
7SP
7SR
7TA
7TB
7U5
8BQ
8FD
F28
FR3
H8D
JG9
JQ2
K9.
KR7
L7M
L~C
L~D
NAPCQ
P64
7X8
DOI 10.1109/JBHI.2020.3004032
DatabaseName IEEE Xplore (IEEE)
IEEE All-Society Periodicals Package (ASPP) 1998–Present
IEEE Electronic Library (IEL)
CrossRef
PubMed
Aluminium Industry Abstracts
Biotechnology Research Abstracts
Ceramic Abstracts
Computer and Information Systems Abstracts
Corrosion Abstracts
Electronics & Communications Abstracts
Engineered Materials Abstracts
Materials Business File
Mechanical & Transportation Engineering Abstracts
Solid State and Superconductivity Abstracts
METADEX
Technology Research Database
ANTE: Abstracts in New Technology & Engineering
Engineering Research Database
Aerospace Database
Materials Research Database
ProQuest Computer Science Collection
ProQuest Health & Medical Complete (Alumni)
Civil Engineering Abstracts
Advanced Technologies Database with Aerospace
Computer and Information Systems Abstracts – Academic
Computer and Information Systems Abstracts Professional
Nursing & Allied Health Premium
Biotechnology and BioEngineering Abstracts
MEDLINE - Academic
DatabaseTitle CrossRef
PubMed
Materials Research Database
Civil Engineering Abstracts
Aluminium Industry Abstracts
Technology Research Database
Computer and Information Systems Abstracts – Academic
Mechanical & Transportation Engineering Abstracts
Electronics & Communications Abstracts
ProQuest Computer Science Collection
Computer and Information Systems Abstracts
ProQuest Health & Medical Complete (Alumni)
Ceramic Abstracts
Materials Business File
METADEX
Biotechnology and BioEngineering Abstracts
Computer and Information Systems Abstracts Professional
Aerospace Database
Nursing & Allied Health Premium
Engineered Materials Abstracts
Biotechnology Research Abstracts
Solid State and Superconductivity Abstracts
Engineering Research Database
Corrosion Abstracts
Advanced Technologies Database with Aerospace
ANTE: Abstracts in New Technology & Engineering
MEDLINE - Academic
DatabaseTitleList
PubMed
MEDLINE - Academic
Materials Research Database
Database_xml – sequence: 1
  dbid: NPM
  name: PubMed
  url: http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed
  sourceTypes: Index Database
– sequence: 2
  dbid: RIE
  name: IEEE Electronic Library (IEL)
  url: https://ieeexplore.ieee.org/
  sourceTypes: Publisher
– sequence: 3
  dbid: 7X8
  name: MEDLINE - Academic
  url: https://search.proquest.com/medline
  sourceTypes: Aggregation Database
DeliveryMethod fulltext_linktorsrc
Discipline Medicine
EISSN 2168-2208
EndPage 673
ExternalDocumentID 32750946
10_1109_JBHI_2020_3004032
9122530
Genre orig-research
Journal Article
GrantInformation_xml – fundername: Innovation and Technology Commission
  funderid: 10.13039/501100003452
– fundername: Midstream Research Programme for Universities
  grantid: MRP/056/17X
GroupedDBID 0R~
4.4
6IF
6IH
6IK
97E
AAJGR
AARMG
AASAJ
AAWTH
ABAZT
ABQJQ
ABVLG
ACIWK
ACPRK
AENEX
AFRAH
AGQYO
AGSQL
AHBIQ
AKJIK
AKQYR
ALMA_UNASSIGNED_HOLDINGS
BEFXN
BFFAM
BGNUA
BKEBE
BPEOZ
EBS
EJD
HZ~
IFIPE
IPLJI
JAVBF
M43
O9-
OCL
PQQKQ
RIA
RIE
RNS
AAYXX
CITATION
NPM
RIG
7QF
7QO
7QQ
7SC
7SE
7SP
7SR
7TA
7TB
7U5
8BQ
8FD
F28
FR3
H8D
JG9
JQ2
K9.
KR7
L7M
L~C
L~D
NAPCQ
P64
7X8
ID FETCH-LOGICAL-c415t-8378ec9cc6695b3d1664bcab88895846afeb0055c5aaa4e66c2020fac2a96fe13
IEDL.DBID RIE
ISICitedReferencesCount 46
ISICitedReferencesURI http://www.webofscience.com/api/gateway?GWVersion=2&SrcApp=Summon&SrcAuth=ProQuest&DestLinkType=CitingArticles&DestApp=WOS_CPL&KeyUT=000626521100006&url=https%3A%2F%2Fcvtisr.summon.serialssolutions.com%2F%23%21%2Fsearch%3Fho%3Df%26include.ft.matches%3Dt%26l%3Dnull%26q%3D
ISSN 2168-2194
2168-2208
IngestDate Thu Oct 02 04:52:10 EDT 2025
Sun Nov 09 05:59:13 EST 2025
Thu Apr 03 06:57:31 EDT 2025
Tue Nov 18 20:55:37 EST 2025
Sat Nov 29 04:18:16 EST 2025
Wed Aug 27 02:48:57 EDT 2025
IsPeerReviewed true
IsScholarly true
Issue 3
Language English
License https://ieeexplore.ieee.org/Xplorehelp/downloads/license-information/IEEE.html
https://doi.org/10.15223/policy-029
https://doi.org/10.15223/policy-037
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-c415t-8378ec9cc6695b3d1664bcab88895846afeb0055c5aaa4e66c2020fac2a96fe13
Notes ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
ORCID 0000-0002-1536-8516
0000-0003-4150-5470
0000-0003-3088-1673
PMID 32750946
PQID 2498877405
PQPubID 85417
PageCount 11
ParticipantIDs proquest_journals_2498877405
pubmed_primary_32750946
crossref_citationtrail_10_1109_JBHI_2020_3004032
ieee_primary_9122530
proquest_miscellaneous_2430662255
crossref_primary_10_1109_JBHI_2020_3004032
PublicationCentury 2000
PublicationDate 2021-03-01
PublicationDateYYYYMMDD 2021-03-01
PublicationDate_xml – month: 03
  year: 2021
  text: 2021-03-01
  day: 01
PublicationDecade 2020
PublicationPlace United States
PublicationPlace_xml – name: United States
– name: Piscataway
PublicationTitle IEEE journal of biomedical and health informatics
PublicationTitleAbbrev JBHI
PublicationTitleAlternate IEEE J Biomed Health Inform
PublicationYear 2021
Publisher IEEE
The Institute of Electrical and Electronics Engineers, Inc. (IEEE)
Publisher_xml – name: IEEE
– name: The Institute of Electrical and Electronics Engineers, Inc. (IEEE)
References fodor (ref12) 2010
golub (ref23) 2012; 3
ref11
ref10
ref2
ref16
härdle (ref13) 2007; 22007
ref19
sedlá?ek (ref18) 2003
sedlacek (ref17) 2005; 12
poon (ref4) 2006
association (ref24) 2014
ref25
avci (ref14) 0
ref22
ref21
alwan (ref1) 2011
(ref20) 2014
ref8
chang (ref15) 2015
ref7
ref9
ref3
ref6
ref5
References_xml – year: 0
  ident: ref14
  article-title: Low-level laser (light) therapy (LLLT) in skin: Stimulating, healing, restoring
  publication-title: Seminars in Cutaneous Medicine and Surgery
– ident: ref6
  doi: 10.1364/BOE.7.004313
– ident: ref5
  doi: 10.1145/3130905
– year: 2011
  ident: ref1
  publication-title: Global Status Report on Noncommunicable Diseases 2010
– ident: ref10
  doi: 10.1109/IEMBS.2003.1280811
– ident: ref25
  doi: 10.1038/s41598-017-11507-3
– ident: ref9
  doi: 10.1109/TBME.2015.2441951
– ident: ref7
  doi: 10.1109/EMBC.2016.7590777
– year: 2010
  ident: ref12
  publication-title: Aesthetic Applications of Intense Pulsed Light
– ident: ref19
  doi: 10.1007/978-1-4020-8486-7
– start-page: 394
  year: 2015
  ident: ref15
  article-title: Evaluation of absorbed light dose in human skin tissue during light therapy by 630 nm LED light
  publication-title: Proc IEEE 12th Int Conf Networ Sens Control
– ident: ref16
  doi: 10.1016/j.sder.2008.08.003
– year: 2014
  ident: ref20
  article-title: ANSI/AAMI/ISO 81060-2: 2013 Noninvasive sphygmomanometers-Part 2: Clinical investigation of automated measurement type. 2013. Association for the Advancement of Medical Instrumentation. Arlington, VA. 2013
– ident: ref11
  doi: 10.1007/s10103-017-2317-4
– ident: ref3
  doi: 10.1109/JBHI.2016.2620995
– volume: 3
  year: 2012
  ident: ref23
  publication-title: Matrix Computations
– volume: 12
  start-page: 427
  year: 2005
  ident: ref17
  article-title: Digital measurement of phase difference-a comparative study of DSP algorithms
  publication-title: Metrol Meas Syst
– year: 2014
  ident: ref24
  article-title: IEEE standard for wearable cuffless blood pressure measuring devices
– ident: ref22
  doi: 10.1016/j.jash.2015.09.011
– ident: ref21
  doi: 10.1161/01.CIR.36.6.805
– ident: ref2
  doi: 10.1016/S0140-6736(12)61766-8
– ident: ref8
  doi: 10.1109/TBME.2018.2874957
– start-page: 639
  year: 2003
  ident: ref18
  article-title: Digital measurement of phase difference of LF signals-a comparison of DSP algorithms
  publication-title: Proc IMEKO XVII World Congr (CD)
– volume: 22007
  year: 2007
  ident: ref13
  publication-title: Applied multivariate statistical analysis
– start-page: 1
  year: 2006
  ident: ref4
  article-title: M-health: The development of cuff-less and wearable blood pressure meters for use in body sensor networks
  publication-title: Proc IEEE/NLM Life Sci Syst Appl Workshop
SSID ssj0000816896
Score 2.4959075
Snippet The prevalence of hypertension has made blood pressure (BP) measurement one of the most wanted functions in wearable devices for convenient and frequent...
SourceID proquest
pubmed
crossref
ieee
SourceType Aggregation Database
Index Database
Enrichment Source
Publisher
StartPage 663
SubjectTerms Algorithms
Biomedical monitoring
Blood
Blood pressure
cuffless blood pressure measurement
EKG
Electrocardiography
Hypertension
Lag time
Medical equipment
multi-wavelength photoplethysmography
Older people
Pressure measurement
Principal component analysis
Principal components analysis
Reactive power
Self-assessment
Sensors
Skin
Statistical analysis
Telemedicine
Transit time
Waveforms
Wavelength
Wearable technology
Title PCA-Based Multi-Wavelength Photoplethysmography Algorithm for Cuffless Blood Pressure Measurement on Elderly Subjects
URI https://ieeexplore.ieee.org/document/9122530
https://www.ncbi.nlm.nih.gov/pubmed/32750946
https://www.proquest.com/docview/2498877405
https://www.proquest.com/docview/2430662255
Volume 25
WOSCitedRecordID wos000626521100006&url=https%3A%2F%2Fcvtisr.summon.serialssolutions.com%2F%23%21%2Fsearch%3Fho%3Df%26include.ft.matches%3Dt%26l%3Dnull%26q%3D
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
journalDatabaseRights – providerCode: PRVIEE
  databaseName: IEEE Electronic Library (IEL)
  customDbUrl:
  eissn: 2168-2208
  dateEnd: 99991231
  omitProxy: false
  ssIdentifier: ssj0000816896
  issn: 2168-2194
  databaseCode: RIE
  dateStart: 20130101
  isFulltext: true
  titleUrlDefault: https://ieeexplore.ieee.org/
  providerName: IEEE
link http://cvtisr.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwlV1La9wwEB7SUEov6SN9uE2CCj2VqrFXtrw67i4JaWnCHvrYm5FkORvY2GHXDuTfd0bWuj00hd4ElmWjGY3m_QG8NyqVmXWax7IccwLb5kqojOdGGNQfnFG-bu3H1_ziYrxYqPkOfBxqYZxzPvnMfaKhj-WXje3IVXasEuQ-gQb6gzyXfa3W4E_xABIejmuEA44HMQ1BzCRWx1-mZ5_RGByhjUpsKwjERlBrc0Wa7x83kodYuV_b9LfO6ZP_-9-nsBe0Szbp2eEZ7Lj6OTw6D_Hzfejmswmf4sVVMl95y39qAp6oL9slmy-blrLJiXLXoZE1m6wum_VVu7xmqNyyWVdVKxSNbErp7qwvLVw7dv7b0ciamp0Q8vfqjqFQIi_P5gV8Pz35NjvjAXiBW7zPW05N5p1V1kqpMiPKRMrUWG3QWlaksOiKEIeyzGZa69RJaWlrK21HWsnKJeIl7NZN7V4DM5UUpU7QaNRx6lCkSYcqTmyU1igJyjKCeLv5hQ1dyQkcY1V46yRWBZGuoPWLQLoIPgyv3PQtOf41eZ_oMkwMJIngYEvhIhzaTYGWKIrcHFXYCN4Nj_G4UQxF167paI6gnvloiEXwqueMYe0tQ735-zffwuMRJcT4BLYD2G3XnTuEh_a2vdqsj5CnF-Mjz9O_AKoo77c
linkProvider IEEE
linkToHtml http://cvtisr.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwlV3Nb9MwFH-aBgIuDBgfgQFG4oTwlsSJOx_balMHbdXDgN0i23HWSV2C2gSJ_573nDTjsCFxsxTHifyen9_3D-CjUYlMrdM8lPkxJ7BtroRK-cAIg_qDM8rXrX2fDubz44sLtdiBz30tjHPOJ5-5Qxr6WH5e2YZcZUcqQu4TaKDfS5MkDttqrd6j4iEkPCBXjAOORzHpwphRqI6-jCZnaA7GaKUS4wqCsRHU3FyR7vvXneRBVu7WN_29c7r3f3_8BB53-iUbtgzxFHZc-QwezLoI-j40i_GQj_DqypmvveU_NEFPlJf1ki2WVU355ES7666VNRuuLqv1Vb28ZqjesnFTFCsUjmxECe-sLS5cOza7cTWyqmQnhP29-s1QLJGfZ_Mcvp2enI8nvINe4BZv9JpTm3lnlbVSqtSIPJIyMVYbtJcVqSy6IMyhNLWp1jpxUlra2kLbWCtZuEi8gN2yKt0rYKaQItcRmo06TBwKNelQyQmN0hplQZ4HEG43P7NdX3KCx1hl3j4JVUaky2j9rCNdAJ_6V362TTn-NXmf6NJP7EgSwMGWwll3bDcZ2qIodAeoxAbwoX-MB46iKLp0VUNzBHXNR1MsgJctZ_Rrbxnq9e3ffA8PJ-ezaTY9m399A49iSo_x6WwHsFuvG_cW7ttf9dVm_c5z9h-f4PIW
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=PCA-Based+Multi-Wavelength+Photoplethysmography+Algorithm+for+Cuffless+Blood+Pressure+Measurement+on+Elderly+Subjects&rft.jtitle=IEEE+journal+of+biomedical+and+health+informatics&rft.au=Liu%2C+Jing&rft.au=Qiu%2C+Shirong&rft.au=Luo%2C+Ningqi&rft.au=Lau%2C+Sze-Kei&rft.date=2021-03-01&rft.issn=2168-2194&rft.eissn=2168-2208&rft.volume=25&rft.issue=3&rft.spage=663&rft.epage=673&rft_id=info:doi/10.1109%2FJBHI.2020.3004032&rft.externalDBID=n%2Fa&rft.externalDocID=10_1109_JBHI_2020_3004032
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=2168-2194&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=2168-2194&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=2168-2194&client=summon