Towards patient connected imaging with ACROBEAT: Adaptive CaRdiac cOne BEAm computed Tomography
Robotic C-arm cone beam computed tomography (CBCT) systems are playing an increasingly pivotal role in interventional cardiac procedures and high precision radiotherapy treatments. One of the main challenges in any form of cardiac imaging is mitigating the intrinsic motion of the heart, which causes...
Gespeichert in:
| Veröffentlicht in: | Physics in medicine & biology Jg. 64; H. 6; S. 065006 |
|---|---|
| Hauptverfasser: | , , , |
| Format: | Journal Article |
| Sprache: | Englisch |
| Veröffentlicht: |
England
11.03.2019
|
| Schlagworte: | |
| ISSN: | 1361-6560, 1361-6560 |
| Online-Zugang: | Weitere Angaben |
| Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
| Abstract | Robotic C-arm cone beam computed tomography (CBCT) systems are playing an increasingly pivotal role in interventional cardiac procedures and high precision radiotherapy treatments. One of the main challenges in any form of cardiac imaging is mitigating the intrinsic motion of the heart, which causes blurring and artefacts in the 3D reconstructed image. Most conventional 3D cardiac CBCT acquisition techniques attempt to combat heart motion through retrospective gating techniques, whereby acquired projections are sorted into the desired cardiac phase after the completion of the scan. However, this results in streaking artefacts and unnecessary radiation exposure to the patient. Here, we present our Adaptive CaRdiac cOne BEAm computed Tomography (ACROBEAT) acquisition protocol that uses the patient's electrocardiogram (ECG) signal to adaptively regulate the gantry velocity and projection time interval in real-time. It enables prospectively gated patient connected imaging in a single sweep of the gantry. The XCAT digital software phantom was used to complete a simulation study to compare ACROBEAT to a conventional multi-sweep retrospective ECG gated acquisition, under a variety of different acquisition conditions. The effect of location and length of the acquisition window and total number of projections acquired on image quality and total scan time were examined. Overall, ACROBEAT enables up to a 5 times average improvement in the contrast-to-noise ratio, a 40% reduction in edge response width and an 80% reduction in total projections acquired compared to conventional multi-sweep retrospective ECG gated acquisition. |
|---|---|
| AbstractList | Robotic C-arm cone beam computed tomography (CBCT) systems are playing an increasingly pivotal role in interventional cardiac procedures and high precision radiotherapy treatments. One of the main challenges in any form of cardiac imaging is mitigating the intrinsic motion of the heart, which causes blurring and artefacts in the 3D reconstructed image. Most conventional 3D cardiac CBCT acquisition techniques attempt to combat heart motion through retrospective gating techniques, whereby acquired projections are sorted into the desired cardiac phase after the completion of the scan. However, this results in streaking artefacts and unnecessary radiation exposure to the patient. Here, we present our Adaptive CaRdiac cOne BEAm computed Tomography (ACROBEAT) acquisition protocol that uses the patient's electrocardiogram (ECG) signal to adaptively regulate the gantry velocity and projection time interval in real-time. It enables prospectively gated patient connected imaging in a single sweep of the gantry. The XCAT digital software phantom was used to complete a simulation study to compare ACROBEAT to a conventional multi-sweep retrospective ECG gated acquisition, under a variety of different acquisition conditions. The effect of location and length of the acquisition window and total number of projections acquired on image quality and total scan time were examined. Overall, ACROBEAT enables up to a 5 times average improvement in the contrast-to-noise ratio, a 40% reduction in edge response width and an 80% reduction in total projections acquired compared to conventional multi-sweep retrospective ECG gated acquisition. Robotic C-arm cone beam computed tomography (CBCT) systems are playing an increasingly pivotal role in interventional cardiac procedures and high precision radiotherapy treatments. One of the main challenges in any form of cardiac imaging is mitigating the intrinsic motion of the heart, which causes blurring and artefacts in the 3D reconstructed image. Most conventional 3D cardiac CBCT acquisition techniques attempt to combat heart motion through retrospective gating techniques, whereby acquired projections are sorted into the desired cardiac phase after the completion of the scan. However, this results in streaking artefacts and unnecessary radiation exposure to the patient. Here, we present our Adaptive CaRdiac cOne BEAm computed Tomography (ACROBEAT) acquisition protocol that uses the patient's electrocardiogram (ECG) signal to adaptively regulate the gantry velocity and projection time interval in real-time. It enables prospectively gated patient connected imaging in a single sweep of the gantry. The XCAT digital software phantom was used to complete a simulation study to compare ACROBEAT to a conventional multi-sweep retrospective ECG gated acquisition, under a variety of different acquisition conditions. The effect of location and length of the acquisition window and total number of projections acquired on image quality and total scan time were examined. Overall, ACROBEAT enables up to a 5 times average improvement in the contrast-to-noise ratio, a 40% reduction in edge response width and an 80% reduction in total projections acquired compared to conventional multi-sweep retrospective ECG gated acquisition.Robotic C-arm cone beam computed tomography (CBCT) systems are playing an increasingly pivotal role in interventional cardiac procedures and high precision radiotherapy treatments. One of the main challenges in any form of cardiac imaging is mitigating the intrinsic motion of the heart, which causes blurring and artefacts in the 3D reconstructed image. Most conventional 3D cardiac CBCT acquisition techniques attempt to combat heart motion through retrospective gating techniques, whereby acquired projections are sorted into the desired cardiac phase after the completion of the scan. However, this results in streaking artefacts and unnecessary radiation exposure to the patient. Here, we present our Adaptive CaRdiac cOne BEAm computed Tomography (ACROBEAT) acquisition protocol that uses the patient's electrocardiogram (ECG) signal to adaptively regulate the gantry velocity and projection time interval in real-time. It enables prospectively gated patient connected imaging in a single sweep of the gantry. The XCAT digital software phantom was used to complete a simulation study to compare ACROBEAT to a conventional multi-sweep retrospective ECG gated acquisition, under a variety of different acquisition conditions. The effect of location and length of the acquisition window and total number of projections acquired on image quality and total scan time were examined. Overall, ACROBEAT enables up to a 5 times average improvement in the contrast-to-noise ratio, a 40% reduction in edge response width and an 80% reduction in total projections acquired compared to conventional multi-sweep retrospective ECG gated acquisition. |
| Author | Reynolds, Tess Keall, Paul J Shieh, Chun-Chien O'Brien, Ricky T |
| Author_xml | – sequence: 1 givenname: Tess surname: Reynolds fullname: Reynolds, Tess organization: Author to whom any correspondence should be addressed – sequence: 2 givenname: Chun-Chien surname: Shieh fullname: Shieh, Chun-Chien – sequence: 3 givenname: Paul J surname: Keall fullname: Keall, Paul J – sequence: 4 givenname: Ricky T surname: O'Brien fullname: O'Brien, Ricky T |
| BackLink | https://www.ncbi.nlm.nih.gov/pubmed/30708356$$D View this record in MEDLINE/PubMed |
| BookMark | eNpNkEtLw0AUhQep2IfuXcks3cTOZF4ZdzHUBxQKJa7DTWbajjSTmEdL_70Rq7g6h3u-c-HeKRr5yluEbil5oCSK5pRJGkghyRxywjb8Ak3-RqN_foymbftBCKVRyK_QmBFFIibkBGVpdYTGtLiGzlnf4aLy3hadNdiVsHV-i4-u2-E4Wa-eFnH6iGMDdecOFiewNg4KXKy8xUNWDt2y7r-raVVW2wbq3ekaXW5g39qbs87Q-_MiTV6D5erlLYmXQcGJ6gItQGgZgWBM5UpaJmhuNHAFG10oCmAtD2WUG5aHWksulMmlIJyHQKk2Ipyh-5-9dVN99rbtstK1hd3vwduqb7OQKi04GWRA785on5fWZHUzXNqcst-nhF_9-2RR |
| CitedBy_id | crossref_primary_10_1002_mp_14811 crossref_primary_10_1002_mp_13670 crossref_primary_10_1002_mp_14462 |
| ContentType | Journal Article |
| DBID | CGR CUY CVF ECM EIF NPM 7X8 |
| DOI | 10.1088/1361-6560/ab03f4 |
| DatabaseName | Medline MEDLINE MEDLINE (Ovid) MEDLINE MEDLINE PubMed MEDLINE - Academic |
| DatabaseTitle | MEDLINE Medline Complete MEDLINE with Full Text PubMed MEDLINE (Ovid) MEDLINE - Academic |
| DatabaseTitleList | MEDLINE MEDLINE - Academic |
| Database_xml | – sequence: 1 dbid: NPM name: PubMed url: http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed sourceTypes: Index Database – sequence: 2 dbid: 7X8 name: MEDLINE - Academic url: https://search.proquest.com/medline sourceTypes: Aggregation Database |
| DeliveryMethod | no_fulltext_linktorsrc |
| Discipline | Medicine Biology Physics |
| EISSN | 1361-6560 |
| ExternalDocumentID | 30708356 |
| Genre | Research Support, Non-U.S. Gov't Journal Article |
| GroupedDBID | --- -DZ -~X 123 1JI 4.4 5B3 5RE 5VS 5ZH 7.M 7.Q AAGCD AAJIO AAJKP AATNI ABCXL ABHWH ABJNI ABLJU ABQJV ABVAM ACAFW ACGFS ACHIP AEFHF AENEX AFYNE AKPSB ALMA_UNASSIGNED_HOLDINGS AOAED ASPBG ATQHT AVWKF AZFZN CBCFC CEBXE CGR CJUJL CRLBU CS3 CUY CVF DU5 EBS ECM EDWGO EIF EJD EMSAF EPQRW EQZZN F5P HAK IHE IJHAN IOP IZVLO KOT LAP M45 N5L N9A NPM P2P PJBAE R4D RIN RNS RO9 ROL RPA SY9 TN5 UCJ W28 XPP 7X8 ABUFD ADEQX AEINN |
| ID | FETCH-LOGICAL-c407t-95a5968a5337b76e351bd9a47af9c71aaee4268bd3b2996457db650442a119d52 |
| IEDL.DBID | 7X8 |
| ISICitedReferencesCount | 3 |
| ISICitedReferencesURI | http://www.webofscience.com/api/gateway?GWVersion=2&SrcApp=Summon&SrcAuth=ProQuest&DestLinkType=CitingArticles&DestApp=WOS_CPL&KeyUT=000460964400001&url=https%3A%2F%2Fcvtisr.summon.serialssolutions.com%2F%23%21%2Fsearch%3Fho%3Df%26include.ft.matches%3Dt%26l%3Dnull%26q%3D |
| ISSN | 1361-6560 |
| IngestDate | Sun Nov 09 09:14:13 EST 2025 Thu Jan 02 22:59:43 EST 2025 |
| IsPeerReviewed | true |
| IsScholarly | true |
| Issue | 6 |
| Language | English |
| LinkModel | DirectLink |
| MergedId | FETCHMERGED-LOGICAL-c407t-95a5968a5337b76e351bd9a47af9c71aaee4268bd3b2996457db650442a119d52 |
| Notes | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
| PMID | 30708356 |
| PQID | 2179540217 |
| PQPubID | 23479 |
| ParticipantIDs | proquest_miscellaneous_2179540217 pubmed_primary_30708356 |
| PublicationCentury | 2000 |
| PublicationDate | 2019-03-11 |
| PublicationDateYYYYMMDD | 2019-03-11 |
| PublicationDate_xml | – month: 03 year: 2019 text: 2019-03-11 day: 11 |
| PublicationDecade | 2010 |
| PublicationPlace | England |
| PublicationPlace_xml | – name: England |
| PublicationTitle | Physics in medicine & biology |
| PublicationTitleAlternate | Phys Med Biol |
| PublicationYear | 2019 |
| SSID | ssj0011824 |
| Score | 2.2930126 |
| Snippet | Robotic C-arm cone beam computed tomography (CBCT) systems are playing an increasingly pivotal role in interventional cardiac procedures and high precision... |
| SourceID | proquest pubmed |
| SourceType | Aggregation Database Index Database |
| StartPage | 065006 |
| SubjectTerms | Algorithms Cone-Beam Computed Tomography - methods Heart - diagnostic imaging Heart - physiology Humans Movement Phantoms, Imaging Retrospective Studies |
| Title | Towards patient connected imaging with ACROBEAT: Adaptive CaRdiac cOne BEAm computed Tomography |
| URI | https://www.ncbi.nlm.nih.gov/pubmed/30708356 https://www.proquest.com/docview/2179540217 |
| Volume | 64 |
| WOSCitedRecordID | wos000460964400001&url=https%3A%2F%2Fcvtisr.summon.serialssolutions.com%2F%23%21%2Fsearch%3Fho%3Df%26include.ft.matches%3Dt%26l%3Dnull%26q%3D |
| hasFullText | |
| inHoldings | 1 |
| isFullTextHit | |
| isPrint | |
| link | http://cvtisr.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwpV1LS8NAEB7UqnjxUV_1xQpeQ5smm2S9SCwtXvqgROgt7CvQQ5NqquC_dzbZ2pMgCCGBDQthd3bmy8638wE8UKUjYRg1lGfUwYgnnUhSc_SJZzzLpJadWmwiHI2i2YxN7IZbaWmVa59YOWpVSLNH3kbozBBd4ONp-eYY1SiTXbUSGtvQ8BDKGKsOZ5ssAmLnWtQ2cB1TZMamKXFhtX_a2lx0vMz_HWBWgWZw9N9PPIZDCzFJXNvECWzpvAl7tejkVxP2hzadjo0V_1OWp5AmFX22JLbOKpGGACMRjpL5ohIyImbHlsS96fi5HyePJFZ8aVwl6fEp2pgkcpxrgu8WRNZKEYokxcJWxD6D10E_6b04VnvBkfiLt3IY5ZQFEUc0GIow0B51hWLcxylkMnQ51xpjeySUJzCgBT4NlUCw5_td7rpM0e457ORFri-B8NATDC8_E6HPdcQDT1ERUYG9JIL7FtyvhzNF2zYJC57r4qNMNwPagot6TtJlXYQjNb4K0WNw9Yfe13CAOIcZ6pjr3kAjw5Wtb2FXfq7m5ftdZTR4H02G38WEyf0 |
| linkProvider | ProQuest |
| openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Towards+patient+connected+imaging+with+ACROBEAT%3A+Adaptive+CaRdiac+cOne+BEAm+computed+Tomography&rft.jtitle=Physics+in+medicine+%26+biology&rft.au=Reynolds%2C+Tess&rft.au=Shieh%2C+Chun-Chien&rft.au=Keall%2C+Paul+J&rft.au=O%27Brien%2C+Ricky+T&rft.date=2019-03-11&rft.eissn=1361-6560&rft.volume=64&rft.issue=6&rft.spage=065006&rft_id=info:doi/10.1088%2F1361-6560%2Fab03f4&rft_id=info%3Apmid%2F30708356&rft_id=info%3Apmid%2F30708356&rft.externalDocID=30708356 |
| thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1361-6560&client=summon |
| thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1361-6560&client=summon |
| thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1361-6560&client=summon |