Artificial neural network algorithm for online glucose prediction from continuous glucose monitoring

Continuous glucose monitoring (CGM) devices could be useful for real-time management of diabetes therapy. In particular, CGM information could be used in real time to predict future glucose levels in order to prevent hypo-/hyperglycemic events. This article proposes a new online method for predictin...

Celý popis

Uložené v:
Podrobná bibliografia
Vydané v:Diabetes technology & therapeutics Ročník 12; číslo 1; s. 81
Hlavní autori: Pérez-Gandía, C, Facchinetti, A, Sparacino, G, Cobelli, C, Gómez, E J, Rigla, M, de Leiva, A, Hernando, M E
Médium: Journal Article
Jazyk:English
Vydavateľské údaje: United States 01.01.2010
Predmet:
ISSN:1557-8593, 1557-8593
On-line prístup:Zistit podrobnosti o prístupe
Tagy: Pridať tag
Žiadne tagy, Buďte prvý, kto otaguje tento záznam!
Popis
Shrnutí:Continuous glucose monitoring (CGM) devices could be useful for real-time management of diabetes therapy. In particular, CGM information could be used in real time to predict future glucose levels in order to prevent hypo-/hyperglycemic events. This article proposes a new online method for predicting future glucose concentration levels from CGM data. The predictor is implemented with an artificial neural network model (NNM). The inputs of the NNM are the values provided by the CGM sensor during the preceding 20 min, while the output is the prediction of glucose concentration at the chosen prediction horizon (PH) time. The method performance is assessed using datasets from two different CGM systems (nine subjects using the Medtronic [Northridge, CA] Guardian and six subjects using the Abbott [Abbott Park, IL] Navigator. Three different PHs are used: 15, 30, and 45 min. The NNM accuracy has been estimated by using the root mean square error (RMSE) and prediction delay. The RMSE is around 10, 18, and 27 mg/dL for 15, 30, and 45 min of PH, respectively. The prediction delay is around 4, 9, and 14 min for upward trends and 5, 15, and 26 min for downward trends, respectively. A comparison with a previously published technique, based on an autoregressive model (ARM), has been performed. The comparison shows that the proposed NNM is more accurate than the ARM, with no significant deterioration in the prediction delay. The proposed NNM is a reliable solution for the online prediction of future glucose concentrations from CGM data.
Bibliografia:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1557-8593
1557-8593
DOI:10.1089/dia.2009.0076