Evaluation of a photodiode array detector for the verification of peak-homogeneity in high-performance liquid chromatography

Photodiode array liquid chromatography detectors are claimed to have the ability of evaluating the homogeneity of chromatographic peaks and this could provide a very powerful tool in support of method development. However, in pharmaceutical analysis, for this to be of practical value it must be capa...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of pharmaceutical and biomedical analysis Jg. 8; H. 3; S. 271
Hauptverfasser: Chan, H K, Carr, G P
Format: Journal Article
Sprache:Englisch
Veröffentlicht: England 1990
Schlagworte:
ISSN:0731-7085
Online-Zugang:Weitere Angaben
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Abstract Photodiode array liquid chromatography detectors are claimed to have the ability of evaluating the homogeneity of chromatographic peaks and this could provide a very powerful tool in support of method development. However, in pharmaceutical analysis, for this to be of practical value it must be capable of detecting inhomogeneities at low levels. In this paper, a test has been devised to challenge the sensitivity of instruments to this application. The test makes use of mixtures of the similar benzodiazepines temazepam and lormetazepam in a chromatographic system which does not separate them. One instrument has demonstrated the ability to detect levels of just 0.5% w/w of one benzodiazepine in the other. Statistical F-tests and t-tests have been used to demonstrate that non-homogeneities have been detected with a high level of confidence. It is concluded that photodiode array detectors have the potential to evaluate the homogeneity of chromatographic peaks with a high degree of sensitivity. However, most instruments do not realize this potential because their software does not make proper use of all the data available.
AbstractList Photodiode array liquid chromatography detectors are claimed to have the ability of evaluating the homogeneity of chromatographic peaks and this could provide a very powerful tool in support of method development. However, in pharmaceutical analysis, for this to be of practical value it must be capable of detecting inhomogeneities at low levels. In this paper, a test has been devised to challenge the sensitivity of instruments to this application. The test makes use of mixtures of the similar benzodiazepines temazepam and lormetazepam in a chromatographic system which does not separate them. One instrument has demonstrated the ability to detect levels of just 0.5% w/w of one benzodiazepine in the other. Statistical F-tests and t-tests have been used to demonstrate that non-homogeneities have been detected with a high level of confidence. It is concluded that photodiode array detectors have the potential to evaluate the homogeneity of chromatographic peaks with a high degree of sensitivity. However, most instruments do not realize this potential because their software does not make proper use of all the data available.Photodiode array liquid chromatography detectors are claimed to have the ability of evaluating the homogeneity of chromatographic peaks and this could provide a very powerful tool in support of method development. However, in pharmaceutical analysis, for this to be of practical value it must be capable of detecting inhomogeneities at low levels. In this paper, a test has been devised to challenge the sensitivity of instruments to this application. The test makes use of mixtures of the similar benzodiazepines temazepam and lormetazepam in a chromatographic system which does not separate them. One instrument has demonstrated the ability to detect levels of just 0.5% w/w of one benzodiazepine in the other. Statistical F-tests and t-tests have been used to demonstrate that non-homogeneities have been detected with a high level of confidence. It is concluded that photodiode array detectors have the potential to evaluate the homogeneity of chromatographic peaks with a high degree of sensitivity. However, most instruments do not realize this potential because their software does not make proper use of all the data available.
Photodiode array liquid chromatography detectors are claimed to have the ability of evaluating the homogeneity of chromatographic peaks and this could provide a very powerful tool in support of method development. However, in pharmaceutical analysis, for this to be of practical value it must be capable of detecting inhomogeneities at low levels. In this paper, a test has been devised to challenge the sensitivity of instruments to this application. The test makes use of mixtures of the similar benzodiazepines temazepam and lormetazepam in a chromatographic system which does not separate them. One instrument has demonstrated the ability to detect levels of just 0.5% w/w of one benzodiazepine in the other. Statistical F-tests and t-tests have been used to demonstrate that non-homogeneities have been detected with a high level of confidence. It is concluded that photodiode array detectors have the potential to evaluate the homogeneity of chromatographic peaks with a high degree of sensitivity. However, most instruments do not realize this potential because their software does not make proper use of all the data available.
Author Carr, G P
Chan, H K
Author_xml – sequence: 1
  givenname: H K
  surname: Chan
  fullname: Chan, H K
  organization: Wyeth Research, Maidenhead, Berkshire, UK
– sequence: 2
  givenname: G P
  surname: Carr
  fullname: Carr, G P
BackLink https://www.ncbi.nlm.nih.gov/pubmed/2094426$$D View this record in MEDLINE/PubMed
BookMark eNo9kM9LwzAcxXOYzG36HyjkJHqoJm3SJkeR-QMGu-i5fJd-u0bbpkvTQcE_3oJjh8eDx-e9w1uSWetaJOSGs0fOePrEsoRHGVPyXrMHxViSRtsZWZzjS7Ls-2_GmORazMk8ZlqIOF2Q3_UR6gGCdS11JQXaVS64wroCKXgPIy0woAnO03JSqJAe0dvSmnOnQ_iJKte4PbZow0htSyu7r6IO_dRpoDVIa3sYbEFN5V0Dwe09dNV4RS5KqHu8PvmKfL2uP1_eo8327ePleROZRGUh0hK4BNRlIkUmE2mUEsrIrESpNNMA2qQxN-WkTJZSK2Z4KmO9EwVLd1LGK3L3v9t5dxiwD3lje4N1DS26oc8VSwQXWTqBtydw2DVY5J23DfgxP90V_wEgUW8D
CitedBy_id crossref_primary_10_3390_pr12122887
crossref_primary_10_1016_0021_9673_94_00979_J
crossref_primary_10_1016_0731_7085_90_80156_J
crossref_primary_10_1016_S0021_9673_94_89096_X
crossref_primary_10_1016_0731_7085_93_80143_O
crossref_primary_10_1016_j_jpba_2023_115358
crossref_primary_10_1016_j_ijcas_2013_04_001
crossref_primary_10_1016_0021_9673_92_85336_R
ContentType Journal Article
DBID CGR
CUY
CVF
ECM
EIF
NPM
7X8
DOI 10.1016/0731-7085(90)80036-O
DatabaseName Medline
MEDLINE
MEDLINE (Ovid)
MEDLINE
MEDLINE
PubMed
MEDLINE - Academic
DatabaseTitle MEDLINE
Medline Complete
MEDLINE with Full Text
PubMed
MEDLINE (Ovid)
MEDLINE - Academic
DatabaseTitleList MEDLINE - Academic
MEDLINE
Database_xml – sequence: 1
  dbid: NPM
  name: PubMed
  url: http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed
  sourceTypes: Index Database
– sequence: 2
  dbid: 7X8
  name: MEDLINE - Academic
  url: https://search.proquest.com/medline
  sourceTypes: Aggregation Database
DeliveryMethod no_fulltext_linktorsrc
Discipline Pharmacy, Therapeutics, & Pharmacology
ExternalDocumentID 2094426
Genre Journal Article
GroupedDBID ---
--K
--M
.~1
0R~
1B1
1RT
1~.
1~5
29L
4.4
457
4G.
53G
5GY
5VS
7-5
71M
8P~
9JM
9JN
AABNK
AACTN
AAEDT
AAEDW
AAIKJ
AAKOC
AALRI
AAOAW
AAQFI
AAQXK
AARLI
AAXKI
AAXUO
ABFNM
ABFRF
ABJNI
ABMAC
ABWVN
ABXDB
ABZDS
ACDAQ
ACGFO
ACGFS
ACIUM
ACNNM
ACRLP
ACRPL
ADBBV
ADECG
ADEZE
ADMUD
ADNMO
AEBSH
AEFWE
AEIPS
AEKER
AENEX
AFJKZ
AFKWA
AFTJW
AFXIZ
AFZHZ
AGHFR
AGUBO
AGYEJ
AHHHB
AIEXJ
AIKHN
AITUG
AJOXV
AJQLL
AJSZI
AKRWK
ALCLG
ALMA_UNASSIGNED_HOLDINGS
AMFUW
AMRAJ
ANKPU
ASPBG
AVWKF
AXJTR
AZFZN
BKOJK
BLXMC
C45
CGR
CS3
CUY
CVF
DU5
EBS
ECM
EFJIC
EIF
EJD
EO8
EO9
EP2
EP3
F5P
FDB
FEDTE
FGOYB
FIRID
FLBIZ
FNPLU
FYGXN
G-2
G-Q
GBLVA
HMT
HMU
HVGLF
HZ~
IHE
J1W
KOM
M34
M36
M41
MO0
N9A
NPM
O-L
O9-
OAUVE
OGGZJ
OVD
OZT
P-8
P-9
P2P
PC.
Q38
R2-
RIG
RNS
ROL
RPZ
SCB
SCC
SCH
SDF
SDG
SDP
SES
SEW
SPC
SPCBC
SPT
SSK
SSP
SSZ
T5K
TEORI
WUQ
XPP
YK3
~G-
7X8
AAYWO
AGQPQ
~HD
ID FETCH-LOGICAL-c387t-95a15ae9f3547535c8848c57fe58909aa9c621cf21c75f5980c16529b4d06b552
IEDL.DBID 7X8
ISICitedReferencesCount 11
ISICitedReferencesURI http://www.webofscience.com/api/gateway?GWVersion=2&SrcApp=Summon&SrcAuth=ProQuest&DestLinkType=CitingArticles&DestApp=WOS_CPL&KeyUT=073170859080036O&url=https%3A%2F%2Fcvtisr.summon.serialssolutions.com%2F%23%21%2Fsearch%3Fho%3Df%26include.ft.matches%3Dt%26l%3Dnull%26q%3D
ISSN 0731-7085
IngestDate Mon Sep 29 06:33:13 EDT 2025
Wed Feb 19 02:36:52 EST 2025
IsPeerReviewed true
IsScholarly true
Issue 3
Language English
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-c387t-95a15ae9f3547535c8848c57fe58909aa9c621cf21c75f5980c16529b4d06b552
Notes ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
PMID 2094426
PQID 80341476
PQPubID 23479
ParticipantIDs proquest_miscellaneous_80341476
pubmed_primary_2094426
PublicationCentury 1900
PublicationDate 1990-00-00
19900101
PublicationDateYYYYMMDD 1990-01-01
PublicationDate_xml – year: 1990
  text: 1990-00-00
PublicationDecade 1990
PublicationPlace England
PublicationPlace_xml – name: England
PublicationTitle Journal of pharmaceutical and biomedical analysis
PublicationTitleAlternate J Pharm Biomed Anal
PublicationYear 1990
SSID ssj0005194
Score 1.396253
Snippet Photodiode array liquid chromatography detectors are claimed to have the ability of evaluating the homogeneity of chromatographic peaks and this could provide...
SourceID proquest
pubmed
SourceType Aggregation Database
Index Database
StartPage 271
SubjectTerms Chromatography, High Pressure Liquid
Spectrophotometry, Ultraviolet
Title Evaluation of a photodiode array detector for the verification of peak-homogeneity in high-performance liquid chromatography
URI https://www.ncbi.nlm.nih.gov/pubmed/2094426
https://www.proquest.com/docview/80341476
Volume 8
WOSCitedRecordID wos073170859080036O&url=https%3A%2F%2Fcvtisr.summon.serialssolutions.com%2F%23%21%2Fsearch%3Fho%3Df%26include.ft.matches%3Dt%26l%3Dnull%26q%3D
hasFullText
inHoldings 1
isFullTextHit
isPrint
link http://cvtisr.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwpV3NS-QwFA_j6sGL6yfqrrvvIKJgsGmbNoGFRWTEi8McFOY2pEnKFLXpfCgM-Mf70k5nTuLBQ3MohIb0ffzeS97vEXJqbIZOKjQ04UbQWEYJzbjAwDW2NsitCQNu6mYTaa8nBgPZ75B_bS2Mv1bZ2sTaUBunfY78SgRob-M0-V-Nqe8Z5c9WFw001sh6hEDGq2U6WHGFIzapyaPSiNEUkUVbOMeSq-W7cxlciJqU130OMWtXc_vze4vcJlsLiAnXjUzskI4td8lZv-Gonl_Cw6rkanoJZ9BfsVfP98h7d8n_DS4HBdXIzZwpnLGgJhM1B2NndaofEO8C4kdAbfAXjpZzKque6Mi9OBROiygfihI8LTKtVlUK8FyMXwsDejRxCJoXxNn75PG2-3BzRxctGqiORDqjkivGlZV5xGMMfLgWIhaap7nlQgZSKamTkOkcn5TnXIpAs4SHMotNkKCUhAfkR-lKe0ggs1nClM4MkyY2zCjFBH6EKc8XE2b5Efnb7vkQVcCfa6jSutfpsN31I3LQ_LZh1TB1DEMMXhGCHH859RfZZOiXm9zKb7Keo-7bE7Kh32bFdPKnFiwce_37D2SA2qU
linkProvider ProQuest
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Evaluation+of+a+photodiode+array+detector+for+the+verification+of+peak-homogeneity+in+high-performance+liquid+chromatography&rft.jtitle=Journal+of+pharmaceutical+and+biomedical+analysis&rft.au=Chan%2C+H+K&rft.au=Carr%2C+G+P&rft.date=1990-01-01&rft.issn=0731-7085&rft.volume=8&rft.issue=3&rft.spage=271&rft_id=info:doi/10.1016%2F0731-7085%2890%2980036-O&rft_id=info%3Apmid%2F2094426&rft_id=info%3Apmid%2F2094426&rft.externalDocID=2094426
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0731-7085&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0731-7085&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0731-7085&client=summon