Automated assessment of drusen using three-dimensional spectral-domain optical coherence tomography

To compare automated assessment of macular drusen delineated by the authors' originally developed algorithm on three-dimensional (3D) spectral-domain optical coherence tomography (SD-OCT) with the assessment by certified graders on color fundus photographs in nonneovascular age-related macular...

Celý popis

Uloženo v:
Podrobná bibliografie
Vydáno v:Investigative ophthalmology & visual science Ročník 53; číslo 3; s. 1576
Hlavní autoři: Iwama, Daisuke, Hangai, Masanori, Ooto, Sotaro, Sakamoto, Atsushi, Nakanishi, Hideo, Fujimura, Takashi, Domalpally, Amitha, Danis, Ronald P, Yoshimura, Nagahisa
Médium: Journal Article
Jazyk:angličtina
japonština
Vydáno: United States 21.03.2012
Témata:
ISSN:1552-5783, 1552-5783
On-line přístup:Zjistit podrobnosti o přístupu
Tagy: Přidat tag
Žádné tagy, Buďte první, kdo vytvoří štítek k tomuto záznamu!
Popis
Shrnutí:To compare automated assessment of macular drusen delineated by the authors' originally developed algorithm on three-dimensional (3D) spectral-domain optical coherence tomography (SD-OCT) with the assessment by certified graders on color fundus photographs in nonneovascular age-related macular degeneration (AMD). Automated assessment of macular drusen was performed using raster scan by 3D OCT scans in 18 eyes with nonneovascular AMD with at least one large druse (≥125 μm) and predominantly soft indistinct drusen. Drusen was defined as the regions that have the distance between the retinal pigment epithelium and calculated Bruch's membrane lines > predefined threshold distances. The agreement was assessed on maximum drusen size and drusen area within grid between 3D SD-OCT and color fundus photographs, and false-negative and false-positive drusen at each threshold distance. There was agreement or agreement within one step in all eyes in maximum drusen size, and 15 (83.3%) of the eyes in the drusen area, except 6 pixels, regardless of threshold distances. However, the number of eyes with exact agreement in the drusen area increased when the threshold distances were smaller than 4 pixels. In the three cases with disagreement in the drusen area, false-negative drusen on 3D SD-OCT were characterized by being small in area and height. Automated assessment of drusen parameters based on the authors' algorithm on 3D SD-OCT, which was limited by the poor detection ability of small drusen, showed good agreement with the assessment by certified graders on color fundus photography in these subjects.
Bibliografie:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1552-5783
1552-5783
DOI:10.1167/iovs.11-8103