Comparison of various robust and efficient load-flow techniques based on Runge–Kutta formulas

•Runge–Kutta formula (RK4) and Adams–Bashfort’s methods have been proposed.•Numerical methods for solving the load flow problem has not been explored yet.•The proposed techniques are faster than RK4 and robust enough.•Medium and large-scale ill-conditioned power systems.•Lower order methods might be...

Celý popis

Uložené v:
Podrobná bibliografia
Vydané v:Electric power systems research Ročník 174; s. 105881
Hlavní autori: Tostado-Véliz, Marcos, Kamel, Salah, Jurado, Francisco
Médium: Journal Article
Jazyk:English
Vydavateľské údaje: Amsterdam Elsevier B.V 01.09.2019
Elsevier Science Ltd
Predmet:
ISSN:0378-7796, 1873-2046
On-line prístup:Získať plný text
Tagy: Pridať tag
Žiadne tagy, Buďte prvý, kto otaguje tento záznam!
Popis
Shrnutí:•Runge–Kutta formula (RK4) and Adams–Bashfort’s methods have been proposed.•Numerical methods for solving the load flow problem has not been explored yet.•The proposed techniques are faster than RK4 and robust enough.•Medium and large-scale ill-conditioned power systems.•Lower order methods might be as robust as higher order ones but more efficient. Based on Continuous Newton’s method, any well-assessed numerical scheme can be adapted for solving the Load-Flow (LF) problem. So far, LF techniques based on 4th order Runge–Kutta formula (RK4) and Adams–Bashfort’s methods (AB) have been proposed. However, there is a huge variety of numerical methods whose adequacy for solving the LF problem has not been explored yet. This paper tries to fill this gap by proposing several LF solvers based on Runge–Kutta (RK) formulas. Thus, several LF techniques based on Midpoint (MP), 3rd order Heun (H3), Simpson 3/8 (S3/8) and an accelerated 3rd order Runge–Kutta (ARK3) formulas are proposed. The performance of the proposed LF techniques is assessed using several medium and large-scale ill-conditioned power systems. The proposed techniques are compared with RK4, AB and other robust LF methods. In addition, their scalability and influence of the loading level are analyzed. The obtained results prove that the proposed LF techniques are faster than RK4 and robust enough to successfully tackle medium and large-scale ill-conditioned power systems. As main conclusion, it is proved that lower order methods might be as robust as higher order ones but more efficient. Therefore, its usage with respect higher order methods (e.g. 4th order ones), should be frequently preferable.
Bibliografia:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
ISSN:0378-7796
1873-2046