Post-fault prediction of transient instabilities using stacked sparse autoencoder

•A fast and robust method is proposed for transient stability assessment.•Stacked sparse autoencoder is used as a stability classification algorithm.•The measurements from the fault-on time period are adopted as inputs.•The method is tested on WSCC test system and on the Turkish power system.•The ro...

Celý popis

Uloženo v:
Podrobná bibliografie
Vydáno v:Electric power systems research Ročník 164; s. 243 - 252
Hlavní autoři: Mahdi, Mohammed, Genc, V.M. Istemihan
Médium: Journal Article
Jazyk:angličtina
Vydáno: Amsterdam Elsevier B.V 01.11.2018
Elsevier Science Ltd
Témata:
ISSN:0378-7796, 1873-2046
On-line přístup:Získat plný text
Tagy: Přidat tag
Žádné tagy, Buďte první, kdo vytvoří štítek k tomuto záznamu!
Popis
Shrnutí:•A fast and robust method is proposed for transient stability assessment.•Stacked sparse autoencoder is used as a stability classification algorithm.•The measurements from the fault-on time period are adopted as inputs.•The method is tested on WSCC test system and on the Turkish power system.•The robustness of the method is tested against different uncertainties. Post-fault prediction of transient stability of power systems has a great impact on the performance of wide area monitoring, protection and control systems. Situational awareness capabilities of a power system are improved by fast detection of instabilities after severe fault occurrences. This allows sufficient time to take necessary corrective control actions. In this paper, a novel method based on stacked sparse autoencoder is proposed to predict the post-fault transient stability status of the power system directly after clearing the fault. A dataset is generated off-line to train a stacked sparse autoencoder, and then the trained stacked sparse autoencoder is used in an online application of predicting any transient instability. The stacked sparse autoencoder is fed by the inputs, which are specific points extracted from the fault-on voltage magnitude measurements collected from the phasor measurement units. The effectiveness of the proposed method is demonstrated and compared with the conventional approaches that adopt multilayer perceptrons or post-fault measurements as it is applied to the 127-bus WSCC test system and to the Turkish power system.
Bibliografie:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
ISSN:0378-7796
1873-2046
DOI:10.1016/j.epsr.2018.08.009