Verification results of jet resonance-enhanced multiphoton ionization as a real-time PCDD/F emission monitor
A jet resonance-enhanced multiphoton ionization (REMPI) monitor was tested on a hazardous-waste-fired boiler for its ability to determine concentrations of polychlorinated dibenzodioxins and dibenzofurans (PCDDs/Fs). Jet REMPI is a real-time instrument capable of highly selective and sensitive (from...
Uložené v:
| Vydané v: | Journal of material cycles and waste management Ročník 10; číslo 1; s. 32 - 37 |
|---|---|
| Hlavní autori: | , , , , |
| Médium: | Journal Article |
| Jazyk: | English |
| Vydavateľské údaje: |
Tokyo
Springer Japan
01.03.2008
Springer Nature B.V |
| Predmet: | |
| ISSN: | 1438-4957, 1611-8227 |
| On-line prístup: | Získať plný text |
| Tagy: |
Pridať tag
Žiadne tagy, Buďte prvý, kto otaguje tento záznam!
|
| Shrnutí: | A jet resonance-enhanced multiphoton ionization (REMPI) monitor was tested on a hazardous-waste-fired boiler for its ability to determine concentrations of polychlorinated dibenzodioxins and dibenzofurans (PCDDs/Fs). Jet REMPI is a real-time instrument capable of highly selective and sensitive (from parts per billion to parts per trillion) detection of a broad range of aromatic compounds, including a number of air toxic compounds. The PCDD/F toxic equivalency (TEQ) value was derived from a predetermined correlation (
R
2
= 0.74) with monochlorobenzene (MClBz). This relationship was applied to nine subsequent jet REMPI on-line measurements of MClBz and parallel, standard extractive sampling for PCDD/F TEQ. For high waste-firing rates, with a range of PCDD/F TEQ values between 3.9 and 6.0 ng TEQ/m
3
, the TEQ values predicted by jet REMPI had a relative difference of 26% with the standard EPA Method 23 results. At low waste-firing rates (0.9–1.6 ng TEQ/m
3
), the relative difference increased to 219%. This limited testing shows that jet REMPI has promise as an on-line diagnostic monitor, providing feedback on the effects on PCDD/F emissions of operating parameter changes such as fuel feed interruptions or air pollution control failures. |
|---|---|
| Bibliografia: | SourceType-Scholarly Journals-1 ObjectType-Feature-1 content type line 14 ObjectType-Article-2 content type line 23 |
| ISSN: | 1438-4957 1611-8227 |
| DOI: | 10.1007/s10163-007-0195-8 |