Penetration depth of sodium hypochlorite into dentinal tubules influenced by different agitation systems

Objectives: To compare the effect of different agitation systems on the penetration depth of sodium hypochlorite into dentinal tubules: An in vitro study. Background: Studies have found the presence of bacteria in dentinal tubule up to 200 μ. Passive irrigation using NaOCl may not adequately elimina...

Full description

Saved in:
Bibliographic Details
Published in:Endodontology : journal of Indian Endodontic Society Vol. 33; no. 2; pp. 81 - 85
Main Authors: Karad, Keyur, Kolhe, Swapnil, Gulve, Meenal, Aher, Gayatri, Kolhe, Priyanka
Format: Journal Article
Language:English
Published: Wolters Kluwer - Medknow Publications 01.04.2021
Medknow Publications and Media Pvt. Ltd
Wolters Kluwer Medknow Publications
Subjects:
ISSN:0970-7212
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Objectives: To compare the effect of different agitation systems on the penetration depth of sodium hypochlorite into dentinal tubules: An in vitro study. Background: Studies have found the presence of bacteria in dentinal tubule up to 200 μ. Passive irrigation using NaOCl may not adequately eliminate these bacteria. Hence, it is mandatory to use agitation systems during irrigation and disinfection of root canal. Materials and Method: Eighty extracted teeth with single canals were used. Standardized access cavity preparation and working length determination were done using visual method. All canals were instrumented till #30, 6%. All samples were immersed in crystal violet dye. The samples were randomly divided into four groups depending on the type of agitation system used (n = 20): Group A: manual dynamic agitation (MDA), Group B: EndoActivator (EA), Group C: EndoUltra (EU), and Group D: EndoVac (EV). Each agitation system was used with 5 ml of 5.25% NaOCl, and each tooth was sectioned into two halves. These sections were analyzed under a stereomicroscope, and NaOCl penetration depth was measured at coronal, middle, and apical third levels. Statistical Analysis Used: Statistical analysis was performed using one-way ANOVA and Tukey's post hoc test. Results: At all levels of examination, EU significantly showed a maximum penetration depth of NaOCl throughout the length of root canal, followed by EA, MDA, and EV. Conclusion: Ultrasonic agitation using EU is the most effective method to disinfect the dentinal tubules throughout the length of root canal than EA and MDA. EV showed the least penetration depth of sodium hypochlorite.
ISSN:0970-7212
DOI:10.4103/endo.endo_39_21