Real-time, precise, rapid and objective visual acuity assessment by self-adaptive step SSVEPs

. This study aimed to explore an online, real-time, and precise method to assess steady-state visual evoked potential (SSVEP)-based visual acuity more rapidly and objectively with self-adaptive spatial frequency steps. . Taking the vertical sinusoidal reversal gratings with different spatial frequen...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of neural engineering Jg. 18; H. 4
Hauptverfasser: Zheng, Xiaowei, Xu, Guanghua, Du, Chenghang, Yan, Wenqiang, Tian, Peiyuan, Zhang, Kai, Liang, Renghao, Han, Chengcheng, Zhang, Sicong
Format: Journal Article
Sprache:Englisch
Veröffentlicht: England 01.08.2021
Schlagworte:
ISSN:1741-2552, 1741-2552
Online-Zugang:Weitere Angaben
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:. This study aimed to explore an online, real-time, and precise method to assess steady-state visual evoked potential (SSVEP)-based visual acuity more rapidly and objectively with self-adaptive spatial frequency steps. . Taking the vertical sinusoidal reversal gratings with different spatial frequencies and temporal frequencies as the visual stimuli, according to the psychometric function for visual acuity assessment, a self-adaptive procedure, the best parameter estimation by sequential testing algorithm, was used to calculate the spatial frequency sequence based on all the previous spatial frequencies and their significance of the SSVEP response. Simultaneously, the canonical correlation analysis (CCA) method with a signal-to-noise ratio (SNR) significance detection criterion was used to judge the significance of the SSVEP response. After 18 iterative trails, the spatial frequency to be presented converged to a value, which was exactly defined as the SSVEP visual acuity threshold. Our results indicated that this SSVEP acuity had a good agreement and correlation with subjective Freiburg Visual Acuity and Contrast Test acuity, and the test-retest repeatability was also good. . The self-adaptive step SSVEP procedure combined with the CCA method and SNR significance detection criterion appears to be an alternative method in the real-time SSVEP acuity test to obtain objective visual acuity more rapidly and precisely.
Bibliographie:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1741-2552
1741-2552
DOI:10.1088/1741-2552/abfaab