Multi-mode optimal operation of advanced adiabatic compressed air energy storage: Explore its value with condenser operation

The weather-dependent renewable energy sources(RESs) and voltage stability performance associated with reactive power balance pose immense challenges to power systems' operation. Salt cavern advanced adiabatic compressed air energy storage(S-CAES) is one of the most promising options to cope wi...

Celý popis

Uloženo v:
Podrobná bibliografie
Vydáno v:Energy (Oxford) Ročník 248; s. 123600
Hlavní autoři: Li, Guangkuo, Chen, Laijun, Xue, Xiaodai, Guo, Zhongjie, Wang, Guohua, Xie, Ningning, Mei, Shengwei
Médium: Journal Article
Jazyk:angličtina
Vydáno: Oxford Elsevier Ltd 01.06.2022
Elsevier BV
Témata:
ISSN:0360-5442, 1873-6785
On-line přístup:Získat plný text
Tagy: Přidat tag
Žádné tagy, Buďte první, kdo vytvoří štítek k tomuto záznamu!
Popis
Shrnutí:The weather-dependent renewable energy sources(RESs) and voltage stability performance associated with reactive power balance pose immense challenges to power systems' operation. Salt cavern advanced adiabatic compressed air energy storage(S-CAES) is one of the most promising options to cope with the emerging issues. Though S-CAES has been extensively studied, limited attention focuses on the value of its reactive power ancillary service. This paper presents a novel S-CAES condenser operation mode that consumes little compressed air and less heat for synchronization and warm-keeping while releasing reactive power by the turbine-generator unit's excitation system for voltage regulation. The merits of condenser mode are highlighted, and the accurate thermodynamic model of S-CAES with multi-parameter coupled charging/discharging power functions is developed. Then, an optimal dispatch model linking the part-load characteristics and multiple service requirements is proposed and further formulated as a mixed-integer linear programming(MILP) problem. Numerical simulation results indicate that S-CAES operating in condenser mode contributes its application in ancillary services markets, and neglecting the part-load characteristics will lead to overly optimistic or even infeasible dispatch results. The breakeven point of the peak-valley ratio is 1.725, below which S-CAES will not participate in the energy market. Besides, sensitivity analysis provides a primary reference for S-CAES's heat supplement optimization and the design of condenser compensation mechanisms in the power system with a high proportion of RESs. •A novel condenser operation mode of S-CAES is proposed.•S-CAES operating in condenser mode consumes little compressed air and less heat, contributing to its application in ancillary services markets.•The multi-mode optimal operation model of S-CAES with condenser mode is proposed.•Dispatch results with and without considering the part-load characteristics are compared.•The heat supplement strategies and condenser compensation mechanism are investigated.
Bibliografie:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
ISSN:0360-5442
1873-6785
DOI:10.1016/j.energy.2022.123600