Simultaneous detection of glucose, uric acid and cholesterol using flexible microneedle electrode array-based biosensor and multi-channel portable electrochemical analyzer

[Display omitted] •A flexible microneedle electrode array-based biosensor (MEAB) was fabricated.•A homemade multi-channel portable electrochemical analyzer (MPEA) was developed.•Simultaneous detection of glucose, uric acid and cholesterol was achieved by using MPEA and MEAB. The development of versa...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Sensors and actuators. B, Chemical Jg. 287; S. 102 - 110
Hauptverfasser: Gao, Jie, Huang, Wenzheng, Chen, Zhipeng, Yi, Changqing, Jiang, Lelun
Format: Journal Article
Sprache:Englisch
Veröffentlicht: Lausanne Elsevier B.V 15.05.2019
Elsevier Science Ltd
Schlagworte:
ISSN:0925-4005, 1873-3077
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:[Display omitted] •A flexible microneedle electrode array-based biosensor (MEAB) was fabricated.•A homemade multi-channel portable electrochemical analyzer (MPEA) was developed.•Simultaneous detection of glucose, uric acid and cholesterol was achieved by using MPEA and MEAB. The development of versatile and low-cost biosensor system for rapid and simultaneous detection of multiple blood metabolites is highly demanded for home healthcare. We developed a flexible microneedle electrode array-based biosensor (MEAB) and a multi-channel portable electrochemical analyzer (MPEA) for the simultaneous detection of glucose, uric acid, and cholesterol. Microneedle electrode array (MEA) was fabricated on the flexible substrate using magnetorheological drawing lithography, followed by sputter coated with Au/Ti film. Then, through biofunctionalized with glucose oxidase, uricase and cholesterol oxidase, MEA was conditioned as a biosensor for simultaneous detection of glucose, uric acid and cholesterol. MEAB demonstrated excellent sensing performance with a wide linear range (glucose, 2–12 mM; uric acid, 0.1–1.2 mM; cholesterol, 1–12 mM), low detection limit (glucose, 260 μM; uric acid, 4 μM; cholesterol, 440 μM), and rapid response time (∼4 s). MPEA, a homemade ARM STM32 microcontroller-based electrochemical analyzer, was validated to be comparable to that of the commercial electrochemical workstation. MPEA integrated with flexible MEAB could accurately and simultaneously detect glucose, uric acid, and cholesterol levels in serum, and the results were consistent with the portable electrochemical device. The ease-of-use of the reported biosensor system will facilitate effective monitoring of blood metabolites at home.
Bibliographie:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
ISSN:0925-4005
1873-3077
DOI:10.1016/j.snb.2019.02.020