Saliva-based point-of-care assay to measure the concentration of pyrazinamide using a mobile UV spectrophotometer
Pyrazinamide, one of the first-line antituberculosis drugs, displays variability in drug exposure that is associated with treatment response. A simple, low-cost assay may be helpful to optimize treatment. This study aimed to develop and validate a point-of-care assay to quantify the concentration of...
Uložené v:
| Vydané v: | Journal of antimicrobial chemotherapy Ročník 80; číslo 1; s. 254 |
|---|---|
| Hlavní autori: | , , , , |
| Médium: | Journal Article |
| Jazyk: | English |
| Vydavateľské údaje: |
England
03.01.2025
|
| Predmet: | |
| ISSN: | 1460-2091, 1460-2091 |
| On-line prístup: | Zistit podrobnosti o prístupe |
| Tagy: |
Pridať tag
Žiadne tagy, Buďte prvý, kto otaguje tento záznam!
|
| Shrnutí: | Pyrazinamide, one of the first-line antituberculosis drugs, displays variability in drug exposure that is associated with treatment response. A simple, low-cost assay may be helpful to optimize treatment. This study aimed to develop and validate a point-of-care assay to quantify the concentration of pyrazinamide in saliva.
All measurements were conducted using the nano-volume drop function on the mobile ultraviolet (UV) spectrophotometer (NP80, Implen, Germany). Assay development involved applying second derivative spectroscopy in combination with the Savitzky-Golay filter between wavelengths of 200-300 nm to increase spectral resolution. Assay validation included assessing selectivity, linearity, accuracy, precision, carry-over and matrix effects. Specificity was also analysed by evaluating the impact of co-administered medications on pyrazinamide results. Sample stability was measured at various temperatures up to 40°C.
The calibration curve (7.5-200 mg/L) was linear (R2 = 0.9991). The overall accuracy (bias%) and precision (CV%) ranged from -0.66% to 5.15%, and 0.56% to 4.95%, respectively. Carry-over and matrix effects were both acceptable with a bias% of <±4% and CV% of <7.5%. Commonly co-administered medications displayed negligible interferences. Levofloxacin displayed analytical interference (bias% = -10.21%) at pyrazinamide concentrations < 25 mg/L, but this will have little clinical implications. Pyrazinamide was considered stable in saliva after 7 days in all storage conditions with a CV% of <6.5% and bias% of <±10.5% for both low- and high-quality control concentrations.
A saliva-based assay for pyrazinamide has been successfully developed and validated using the mobile UV spectrophotometer. |
|---|---|