Disposable ion-selective electrodes

In this paper we describe a low-cost ion-selective electrode in double matrix membrance technology. This sensor is prepared from filter paper with an evaporated silver conducting line on one side. For insulation the sensor is laminated with a preperforated heat-sealing film. A coated film sensor in...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Sensors and actuators. B, Chemical Jg. 25; H. 1; S. 721 - 723
Hauptverfasser: Borchardt, Michael, Dumschat, Christa, Cammann, karl, Knoll, Meinhard
Format: Journal Article Tagungsbericht
Sprache:Englisch
Veröffentlicht: Lausanne Elsevier B.V 01.04.1995
Amsterdam Elsevier
New York, NY
Schlagworte:
ISSN:0925-4005, 1873-3077
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Abstract In this paper we describe a low-cost ion-selective electrode in double matrix membrance technology. This sensor is prepared from filter paper with an evaporated silver conducting line on one side. For insulation the sensor is laminated with a preperforated heat-sealing film. A coated film sensor in double matrix membrane technology is produced by filling one hole with a defined volume of an ion-selective polymer matrix membrane cocktail. The double matrix membrane (DMM) is formed by the polymer matrix membrane and the additional microfibre matrix (MFM) of the filter paper. Such sensors can be produced in a batch process. Therefore mass-production of low-cost sensors is possible. The response behaviour of the low-cost ion-selective electrode is comparable to that of conventional macro ion-selective electrodes.
AbstractList In this paper we describe a low-cost ion-selective electrode in double matrix membrance technology. This sensor is prepared from filter paper with an evaporated silver conducting line on one side. For insulation the sensor is laminated with a preperforated heat-sealing film. A coated film sensor in double matrix membrane technology is produced by filling one hole with a defined volume of an ion-selective polymer matrix membrane cocktail. The double matrix membrane (DMM) is formed by the polymer matrix membrane and the additional microfibre matrix (MFM) of the filter paper. Such sensors can be produced in a batch process. Therefore mass-production of low-cost sensors is possible. The response behaviour of the low-cost ion-selective electrode is comparable to that of conventional macro ion-selective electrodes.
Author Cammann, karl
Knoll, Meinhard
Borchardt, Michael
Dumschat, Christa
Author_xml – sequence: 1
  givenname: Michael
  surname: Borchardt
  fullname: Borchardt, Michael
– sequence: 2
  givenname: Christa
  surname: Dumschat
  fullname: Dumschat, Christa
– sequence: 3
  givenname: karl
  surname: Cammann
  fullname: Cammann, karl
– sequence: 4
  givenname: Meinhard
  surname: Knoll
  fullname: Knoll, Meinhard
BackLink http://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=3635381$$DView record in Pascal Francis
BookMark eNqFkM1LxDAQxYOsYHf1P_CwoAc9RCdJ0zYeBFk_YcGLnkM-phCp7ZKUBf9726168KCnGZj3e8x7czJruxYJOWZwwYAVl6C4pDmAPFPyvJJMKir2SMaqUlABZTkj2Y_kgMxTegOAXBSQkZPbkDZdMrbBZehamrBB14ctLndL7DymQ7Jfmybh0ddckNf7u5fVI10_PzytbtbUCSF6KoEX3GNuOJccWekQFTrlubTOMiXLWpUMXQHWWuWFlVU1XAERpfEVFGJBTiffjUnONHU0rQtJb2J4N_FDi0JIUbFBdjXJXOxSilhrF3rTD9_30YRGM9BjK3qMrMfIWkm9a0WLAc5_wd_2_2DXE4ZD_m3AqJML2Dr0IQ41ad-Fvw0-AVMxeoI
CitedBy_id crossref_primary_10_1002__SICI_1521_4109_199910_11_14_1035__AID_ELAN1035_3_0_CO_2_I
crossref_primary_10_1023_A_1016635809428
crossref_primary_10_1016_S0956_5663_98_00103_1
crossref_primary_10_1016_j_bios_2019_111317
crossref_primary_10_1016_S0003_2670_01_00891_1
crossref_primary_10_1081_AL_120017261
crossref_primary_10_1016_j_trac_2020_116070
crossref_primary_10_1016_j_electacta_2011_02_053
crossref_primary_10_1016_j_snb_2021_129808
crossref_primary_10_1016_j_snb_2023_135190
crossref_primary_10_1016_j_snb_2018_06_127
crossref_primary_10_1016_S0925_4005_00_00410_X
Cites_doi 10.1016/0925-4005(95)85059-7
10.1016/0925-4005(95)85060-0
10.1007/BF00323930
10.1016/0172-2190(91)90248-4
10.1016/0925-4005(93)01164-Y
ContentType Journal Article
Conference Proceeding
Copyright 1995
1995 INIST-CNRS
Copyright_xml – notice: 1995
– notice: 1995 INIST-CNRS
DBID AAYXX
CITATION
IQODW
DOI 10.1016/0925-4005(95)85159-3
DatabaseName CrossRef
Pascal-Francis
DatabaseTitle CrossRef
DatabaseTitleList
DeliveryMethod fulltext_linktorsrc
Discipline Engineering
Chemistry
EISSN 1873-3077
EndPage 723
ExternalDocumentID 3635381
10_1016_0925_4005_95_85159_3
0925400595851593
GroupedDBID --K
--M
-~X
.~1
0R~
123
1B1
1RT
1~.
1~5
4.4
457
4G.
53G
5VS
7-5
71M
8P~
9JN
AABNK
AACTN
AAEDT
AAEDW
AAIAV
AAIKJ
AAKOC
AALRI
AAOAW
AAQFI
AAQXK
AARLI
AAXUO
ABFNM
ABMAC
ABXDB
ABYKQ
ACDAQ
ACGFS
ACNNM
ACRLP
ADBBV
ADECG
ADEZE
ADMUD
ADTZH
AEBSH
AECPX
AEKER
AFKWA
AFTJW
AFZHZ
AGHFR
AGUBO
AGYEJ
AHHHB
AHJVU
AIEXJ
AIKHN
AITUG
AJBFU
AJOXV
AJQLL
AJSZI
ALMA_UNASSIGNED_HOLDINGS
AMFUW
AMRAJ
ASPBG
AVWKF
AXJTR
AZFZN
BJAXD
BKOJK
BLXMC
CS3
EBS
EFJIC
EFLBG
EJD
EO8
EO9
EP2
EP3
F5P
FDB
FEDTE
FGOYB
FIRID
FLBIZ
FNPLU
FYGXN
G-Q
GBLVA
HMU
HVGLF
HZ~
IHE
J1W
JJJVA
KOM
M36
M41
MO0
N9A
O-L
O9-
OAUVE
OZT
P-8
P-9
PC.
Q38
R2-
RIG
RNS
ROL
RPZ
SCB
SCC
SCH
SDF
SDG
SDP
SES
SEW
SPC
SPCBC
SSK
SST
SSZ
T5K
TN5
WUQ
XFK
YK3
~G-
9DU
AATTM
AAXKI
AAYWO
AAYXX
ABWVN
ACLOT
ACRPL
ADNMO
AEIPS
AFJKZ
AGQPQ
AIIUN
ANKPU
APXCP
CITATION
EFKBS
~HD
AFXIZ
AGCQF
AGRNS
BNPGV
IQODW
SSH
ID FETCH-LOGICAL-c333t-50262de4a2252e17cee9ec9d25bcb1957f971ec60bbb9d3b588c9d0eee5ad8063
ISICitedReferencesCount 20
ISICitedReferencesURI http://www.webofscience.com/api/gateway?GWVersion=2&SrcApp=Summon&SrcAuth=ProQuest&DestLinkType=CitingArticles&DestApp=WOS_CPL&KeyUT=0925400595851593&url=https%3A%2F%2Fcvtisr.summon.serialssolutions.com%2F%23%21%2Fsearch%3Fho%3Df%26include.ft.matches%3Dt%26l%3Dnull%26q%3D
ISSN 0925-4005
IngestDate Mon Jul 21 09:14:01 EDT 2025
Sat Nov 29 02:51:18 EST 2025
Tue Nov 18 22:19:44 EST 2025
Fri Feb 23 02:23:10 EST 2024
IsPeerReviewed true
IsScholarly true
Issue 1
Keywords Ion-selective electrodes
Ion selective electrode
Disposable
Membrane electrode
Calibration
Preparation
Measurement sensor
Language English
License https://www.elsevier.com/tdm/userlicense/1.0
CC BY 4.0
LinkModel OpenURL
MeetingName International meeting on chemical sensors
MergedId FETCHMERGED-LOGICAL-c333t-50262de4a2252e17cee9ec9d25bcb1957f971ec60bbb9d3b588c9d0eee5ad8063
PageCount 3
ParticipantIDs pascalfrancis_primary_3635381
crossref_citationtrail_10_1016_0925_4005_95_85159_3
crossref_primary_10_1016_0925_4005_95_85159_3
elsevier_sciencedirect_doi_10_1016_0925_4005_95_85159_3
PublicationCentury 1900
PublicationDate 1995-04-01
PublicationDateYYYYMMDD 1995-04-01
PublicationDate_xml – month: 04
  year: 1995
  text: 1995-04-01
  day: 01
PublicationDecade 1990
PublicationPlace Lausanne
Amsterdam
New York, NY
PublicationPlace_xml – name: Amsterdam
– name: Lausanne
– name: New York, NY
PublicationTitle Sensors and actuators. B, Chemical
PublicationYear 1995
Publisher Elsevier B.V
Elsevier
Publisher_xml – name: Elsevier B.V
– name: Elsevier
References Dumschat, Borchardt, Diekmann, Cammann, Knoll (bib6) 1995; 24-25
Knoll, Cammann, Dumschat, Borchardt, Ho¨gg (bib3) 1994; 20
Dumschat, Borchardt, Diekmann, Hepke, Knoll (bib4) 1994; 348
M. Knoll, German Patent No. P41 37 261.1, (13 Nov. 1991)
Diekmann, Dumschat, Cammann, Knoll (bib7) 1995; 24-25
Cammann (bib1) 1979
(bib5) 1976; 48
Cammann (10.1016/0925-4005(95)85159-3_bib1) 1979
Diekmann (10.1016/0925-4005(95)85159-3_bib7) 1995; 24-25
Dumschat (10.1016/0925-4005(95)85159-3_bib6) 1995; 24-25
Dumschat (10.1016/0925-4005(95)85159-3_bib4) 1994; 348
(10.1016/0925-4005(95)85159-3_bib5) 1976; 48
Knoll (10.1016/0925-4005(95)85159-3_bib3) 1994; 20
10.1016/0925-4005(95)85159-3_bib2
References_xml – volume: 20
  start-page: 1
  year: 1994
  ident: bib3
  article-title: Microfibre matrix-supported ion-selective PVC-membranes
  publication-title: Sensors and Actuators B
– volume: 24-25
  start-page: 279
  year: 1995
  end-page: 281
  ident: bib6
  article-title: Potentiometric test strip
  publication-title: Sensors and Actuators B
– year: 1979
  ident: bib1
  publication-title: Working with Ion-selective Electrodes
– volume: 48
  start-page: 129
  year: 1976
  ident: bib5
  article-title: Recommendations for Nomenclature of Ion-Selective Electrodes
  publication-title: Pure Appl. Chem.
– volume: 24-25
  start-page: 276
  year: 1995
  end-page: 278
  ident: bib7
  article-title: Disposable reference electrode
  publication-title: Sensors and Actuators B
– reference: M. Knoll, German Patent No. P41 37 261.1, (13 Nov. 1991)
– volume: 348
  start-page: 553
  year: 1994
  ident: bib4
  article-title: Double matrix membranes for potentiometric cation sensitive sensors
  publication-title: Fresenius′ Z. Anal. Chem.
– volume: 24-25
  start-page: 276
  year: 1995
  ident: 10.1016/0925-4005(95)85159-3_bib7
  article-title: Disposable reference electrode
  publication-title: Sensors and Actuators B
  doi: 10.1016/0925-4005(95)85059-7
– year: 1979
  ident: 10.1016/0925-4005(95)85159-3_bib1
– volume: 24-25
  start-page: 279
  year: 1995
  ident: 10.1016/0925-4005(95)85159-3_bib6
  article-title: Potentiometric test strip
  publication-title: Sensors and Actuators B
  doi: 10.1016/0925-4005(95)85060-0
– volume: 348
  start-page: 553
  year: 1994
  ident: 10.1016/0925-4005(95)85159-3_bib4
  article-title: Double matrix membranes for potentiometric cation sensitive sensors
  publication-title: Fresenius′ Z. Anal. Chem.
  doi: 10.1007/BF00323930
– volume: 48
  start-page: 129
  year: 1976
  ident: 10.1016/0925-4005(95)85159-3_bib5
  article-title: Recommendations for Nomenclature of Ion-Selective Electrodes
  publication-title: Pure Appl. Chem.
– ident: 10.1016/0925-4005(95)85159-3_bib2
  doi: 10.1016/0172-2190(91)90248-4
– volume: 20
  start-page: 1
  year: 1994
  ident: 10.1016/0925-4005(95)85159-3_bib3
  article-title: Microfibre matrix-supported ion-selective PVC-membranes
  publication-title: Sensors and Actuators B
  doi: 10.1016/0925-4005(93)01164-Y
SSID ssj0004360
Score 1.5804225
Snippet In this paper we describe a low-cost ion-selective electrode in double matrix membrance technology. This sensor is prepared from filter paper with an...
SourceID pascalfrancis
crossref
elsevier
SourceType Index Database
Enrichment Source
Publisher
StartPage 721
SubjectTerms Chemistry
Electrochemistry
Electrodes: preparations and properties
Exact sciences and technology
General and physical chemistry
Ion selective electrodes
Title Disposable ion-selective electrodes
URI https://dx.doi.org/10.1016/0925-4005(95)85159-3
Volume 25
WOSCitedRecordID wos0925400595851593&url=https%3A%2F%2Fcvtisr.summon.serialssolutions.com%2F%23%21%2Fsearch%3Fho%3Df%26include.ft.matches%3Dt%26l%3Dnull%26q%3D
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
journalDatabaseRights – providerCode: PRVESC
  databaseName: Elsevier SD Freedom Collection Journals 2021
  customDbUrl:
  eissn: 1873-3077
  dateEnd: 99991231
  omitProxy: false
  ssIdentifier: ssj0004360
  issn: 0925-4005
  databaseCode: AIEXJ
  dateStart: 19950101
  isFulltext: true
  titleUrlDefault: https://www.sciencedirect.com
  providerName: Elsevier
link http://cvtisr.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwtV1LTxsxELYiqEQrDpRSlVcVqT20QqZZO16vjyGh6oMsCIKUU1frx0pIaIlIQPx8xmvvq4CiHnqIFXljO_I3sWcm880g9LmnQ2UCk2JpjML9VNgyL_0AE5XpTGrOUqWLYhM8jqPpVJx1On9KLsz9Nc_z6OFBzP4r1NAHYFvq7D_AXU0KHfAeQIcWYIf2KfDP3j8XYJraGjpFHlZLELEVdQ4Pjtzf6y5BQFNURlc2dqvgUMG3wvOiNI6NKPI1cnQdZ3h0aina56NJy5E6uhxfQPek5XUdDsbjQRy3XKm_49OTk3qo9vQ71ghSKVxg_r5u-hEJAyO0x5pHquMyl6KDaeOE5I4Q7S9b7sjGT85x51Ko5gZlW0AjIqt9-elaqbP_utKqQEMK-hS1zPxVQsMIjPPVwc_j6a-aOUsLHnm1UEmuDMJvVd8Xwb76hV9SXtZn6Rygy1wtlIaCMtlAWzV1s3tWCcVb1DH5JloblmX9NtGbRgbKd-hTjX23hX23xn4LXX4_ngx_YF83AytK6QIzsKuJNv0UzmpiAg5LCqOEJkwqGQjGM8EDo8KelFJoKlkUwdOeMYalOgKd9T1ayW9y8wF1M8UZCVMuCaV9A9ZERkQIL5NmWRRKvo1ouSGJ8knlbW2T66SMHrTbmNhtTARLim1M6DbC1aiZS6qy5PO83OvEK4ZO4UtAXpaM3G9BUy3nBWNnyfNd9Lr-FeyhlcXtndlHr9T94mp--9FL0yNw-YI-
linkProvider Elsevier
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=proceeding&rft.title=Sensors+and+actuators.+B%2C+Chemical&rft.atitle=Disposable+ion-selective+electrodes&rft.au=BORCHARDT%2C+M&rft.au=DUMSCHAT%2C+C&rft.au=CAMMANN%2C+K&rft.au=KNOLL%2C+M&rft.date=1995-04-01&rft.pub=Elsevier&rft.issn=0925-4005&rft.volume=25&rft.issue=1-3&rft.spage=721&rft.epage=723&rft_id=info:doi/10.1016%2F0925-4005%2895%2985159-3&rft.externalDBID=n%2Fa&rft.externalDocID=3635381
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0925-4005&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0925-4005&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0925-4005&client=summon