Use of computer tomography imaging for analyzing bone remodeling around a percutaneous osseointegrated implant

Osseointegration (OI) is being used for the direct skeletal attachment of prosthetic limbs using an intramedullary stem that extends percutaneously from the subject's residual limb. For this technology to be successful, bone ingrowth and remodeling around the implant must occur. Physicians need...

Celý popis

Uložené v:
Podrobná bibliografia
Vydané v:Journal of orthopaedic research Ročník 40; číslo 9; s. 2065 - 2075
Hlavní autori: Wankier, Zakary, Taylor, Carolyn, Drew, Alex, Kubiak, Erik, Agarwal, Jayant, Sinclair, Sarina
Médium: Journal Article
Jazyk:English
Vydavateľské údaje: United States 01.09.2022
Predmet:
ISSN:0736-0266, 1554-527X, 1554-527X
On-line prístup:Získať plný text
Tagy: Pridať tag
Žiadne tagy, Buďte prvý, kto otaguje tento záznam!
Popis
Shrnutí:Osseointegration (OI) is being used for the direct skeletal attachment of prosthetic limbs using an intramedullary stem that extends percutaneously from the subject's residual limb. For this technology to be successful, bone ingrowth and remodeling around the implant must occur. Physicians need an effective way to assess bone remodeling to make informed treatment and rehabilitation decisions. Previous studies utilizing two‐dimensional imaging X‐ray as a tool to monitor bone‐remodeling around OI devices have limitations. This study describes methodology that was developed utilizing computed tomography (CT) imaging as a tool for analyzing bone remodeling around a percutaneous OI implant. Six transfemoral amputees implanted with a percutaneous osseointegrated prosthesis (POP) had CT scans taken of their residual femur at 6 and 52 weeks postoperatively. Three‐dimensional femoral models were processed using custom MATLAB script to collect cortical and medullary morphology measurements. Morphology data from 6‐ and 52‐week scans were compared to quantify bone remodeling around the POP implant. Fifty‐two weeks after implantation of the POP device, increases in cortical bone area and thickness were observed around the porous‐coated stem. Minimal changes were observed in the medullary canal parameters within the periprosthetic regions. This study successfully utilized CT imaging and three‐dimensional modeling techniques to analyze longitudinal data of bone remodeling around a transfemoral percutaneous implant. These methods have the potential to be used as a clinical tool for evaluating orthopedic implants in vivo. Data collected suggests that the POP device achieved the desired bone remodeling around the porous‐coated region of the implanted stem.
Bibliografia:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0736-0266
1554-527X
1554-527X
DOI:10.1002/jor.25247