Optic Nerve Topography in Multiple Sclerosis Diagnosis: The Utility of Visual Evoked Potentials

To assess the added value of the optic nerve region (by using visual evoked potentials [VEPs]) to the current diagnostic criteria. From the Barcelona clinically isolated syndrome (CIS) cohort, patients with complete information to assess dissemination in space (DIS), the optic nerve region, and diss...

Celý popis

Uloženo v:
Podrobná bibliografie
Vydáno v:Neurology Ročník 96; číslo 4; s. e482
Hlavní autoři: Vidal-Jordana, Angela, Rovira, Alex, Arrambide, Georgina, Otero-Romero, Susana, Río, Jordi, Comabella, Manuel, Nos, Carlos, Castilló, Joaquin, Galan, Ingrid, Cabello, Sergio, Moncho, Dulce, Rahnama, Kimia, Thonon, Vanessa, Rodríguez-Acevedo, Breogan, Zabalza, Ana, Midaglia, Luciana, Auger, Cristina, Sastre-Garriga, Jaume, Montalban, Xavier, Tintoré, Mar
Médium: Journal Article
Jazyk:angličtina
Vydáno: United States 26.01.2021
Témata:
ISSN:1526-632X, 1526-632X
On-line přístup:Zjistit podrobnosti o přístupu
Tagy: Přidat tag
Žádné tagy, Buďte první, kdo vytvoří štítek k tomuto záznamu!
Popis
Shrnutí:To assess the added value of the optic nerve region (by using visual evoked potentials [VEPs]) to the current diagnostic criteria. From the Barcelona clinically isolated syndrome (CIS) cohort, patients with complete information to assess dissemination in space (DIS), the optic nerve region, and dissemination in time at baseline (n = 388) were selected. Modified DIS (modDIS) criteria were constructed by adding the optic nerve to the current DIS regions. The DIS and modDIS criteria were evaluated with univariable Cox proportional hazard regression analyses with the time to the second attack as the outcome. A subset of these patients who had at least 10 years of follow-up or a second attack occurring within 10 years (n = 151) were selected to assess the diagnostic performance. The analyses were also performed according to CIS topography (optic neuritis vs non-optic neuritis). The addition of the optic nerve as a fifth region improved the diagnostic performance by slightly increasing the accuracy (2017 DIS 75.5%, modDIS 78.1%) and the sensitivity (2017 DIS 79.2%, modDIS 82.3%) without lowering the specificity (2017 DIS 52.4%, modDIS 52.4%). When the analysis was conducted according to CIS topography, the modDIS criteria performed similarly in both optic neuritis and non-optic neuritis CIS. The addition of the optic nerve, assessed by VEP, as a fifth region in the current DIS criteria slightly improves the diagnostic performance because it increases sensitivity without losing specificity.
Bibliografie:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ObjectType-Undefined-3
ISSN:1526-632X
1526-632X
DOI:10.1212/WNL.0000000000011339