An overlapping peaks separation algorithm for ion mobility spectrometry based on second‐order differentiation and dynamic inertia weight particle swarm optimization algorithm

Rationale Ion mobility spectrometry (IMS) is a powerful analytical tool extensively applied in numerous domains. However, there still exists the phenomenon of peaks overlapping in the analysis of isomers with similar structures due to the limited resolution of IMS. In this paper, a dynamic inertia w...

Celý popis

Uloženo v:
Podrobná bibliografie
Vydáno v:Rapid communications in mass spectrometry Ročník 36; číslo 2; s. e9220 - n/a
Hlavní autoři: Gao, Ren, Li, Junhui, Gao, Wenqing, Li, Lei, Wang, Xinkai, Wu, Bing, Wu, Yong, Yu, Jiancheng
Médium: Journal Article
Jazyk:angličtina
Vydáno: England 30.01.2022
ISSN:0951-4198, 1097-0231, 1097-0231
On-line přístup:Získat plný text
Tagy: Přidat tag
Žádné tagy, Buďte první, kdo vytvoří štítek k tomuto záznamu!
Popis
Shrnutí:Rationale Ion mobility spectrometry (IMS) is a powerful analytical tool extensively applied in numerous domains. However, there still exists the phenomenon of peaks overlapping in the analysis of isomers with similar structures due to the limited resolution of IMS. In this paper, a dynamic inertia weight particle swarm optimization (DIWPSO) algorithm combined with second‐order differentiation is proposed to separate the IMS overlapping peaks efficiently and precisely. Methods It can identify the component number of overlapping peaks and limit those parameters (ion mobility, intensity, and full‐width at half maximum of each single peak) of the peak model in a small range using second‐order differentiation. Based on this, DIWPSO that has been set the best operating parameters is capable of accurately separating IMS overlapping peaks to identify the compound within a short time. Results A comparison between the performance of DIWPSO and the improved particle swarm optimization (IPSO) found that DIWPSO with separation errors less than 2.34% overall outperforms IPSO whose maximum error is up to 5.58%. Moreover, the running time of DIWPSO is 30–80 times less than that of IPSO, and DIWPSO exhibits stronger robustness. Conclusions This method can automatically identify the component number of IMS overlapping peaks and resolve them with muticomponents and different overlapped degrees rapidly and accurately, which further improves the structural resolution of IMS.
Bibliografie:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0951-4198
1097-0231
1097-0231
DOI:10.1002/rcm.9220