Signal detection algorithms for interferometric sensors with harmonic phase modulation: miscalibration of modulation parameters
In the current paper, we have developed an analytical apparatus that allows us to calculate the phase error produced by miscalibration of modulation parameters. The case of harmonic modulation is considered, and the analysis is performed for cases of miscalibration for two parameters: amplitude and...
Uloženo v:
| Vydáno v: | Applied optics. Optical technology and biomedical optics Ročník 57; číslo 25; s. 7127 |
|---|---|
| Hlavní autoři: | , , , |
| Médium: | Journal Article |
| Jazyk: | angličtina |
| Vydáno: |
United States
01.09.2018
|
| ISSN: | 1539-4522, 2155-3165, 1539-4522 |
| On-line přístup: | Zjistit podrobnosti o přístupu |
| Tagy: |
Přidat tag
Žádné tagy, Buďte první, kdo vytvoří štítek k tomuto záznamu!
|
| Shrnutí: | In the current paper, we have developed an analytical apparatus that allows us to calculate the phase error produced by miscalibration of modulation parameters. The case of harmonic modulation is considered, and the analysis is performed for cases of miscalibration for two parameters: amplitude and start phase. Two demodulation algorithms are considered: a conventional 4-point algorithm, based on an ordinary least-squares approach, and a previously developed 4+1 algorithm with high immunity to phase error, induced by change of target phase on the demodulation interval. Predictions, given by developed analytical equations, are verified by means of numeric modeling. |
|---|---|
| Bibliografie: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
| ISSN: | 1539-4522 2155-3165 1539-4522 |
| DOI: | 10.1364/AO.57.007127 |