Interventional 4-D C-Arm CT Perfusion Imaging Using Interleaved Scanning and Partial Reconstruction Interpolation

Tissue perfusion measurement during catheter-guided stroke treatment in the interventional suite is currently not possible. In this work, we present a novel approach that uses a C-arm angiography system capable of computed tomography (CT)-like imaging (C-arm CT) for this purpose. With C-arm CT one r...

Celý popis

Uložené v:
Podrobná bibliografia
Vydané v:IEEE transactions on medical imaging Ročník 31; číslo 4; s. 892 - 906
Hlavní autori: Fieselmann, A., Ganguly, A., Deuerling-Zheng, Y., Zellerhoff, M., Rohkohl, C., Boese, J., Hornegger, J., Fahrig, R.
Médium: Journal Article
Jazyk:English
Vydavateľské údaje: United States IEEE 01.04.2012
Predmet:
ISSN:0278-0062, 1558-254X, 1558-254X
On-line prístup:Získať plný text
Tagy: Pridať tag
Žiadne tagy, Buďte prvý, kto otaguje tento záznam!
Abstract Tissue perfusion measurement during catheter-guided stroke treatment in the interventional suite is currently not possible. In this work, we present a novel approach that uses a C-arm angiography system capable of computed tomography (CT)-like imaging (C-arm CT) for this purpose. With C-arm CT one reconstructed volume can be obtained every 4-6 s which makes it challenging to measure the flow of an injected contrast bolus. We have developed an interleaved scanning (IS) protocol that uses several scan sequences to increase temporal sampling. Using a dedicated 4-D reconstruction approach based on partial reconstruction interpolation (PRI) we can optimally process our data. We evaluated our combined approach (IS-PRI) with simulations and a study in five healthy pigs. In our simulations, the cerebral blood flow values (unit: ml/100 g/min) were 60 (healthy tissue) and 20 (pathological tissue). For one scan sequence the values were estimated with standard deviations of 14.3 and 2.9, respectively. For two interleaved sequences the standard deviations decreased to 3.6 and 1.5, respectively. We used perfusion CT to validate the in vivo results. With two interleaved sequences we achieved promising correlations ranging from r =0.63 to r =0.94. The results suggest that C-arm CT tissue perfusion imaging is feasible with two interleaved scan sequences.
AbstractList Tissue perfusion measurement during catheter-guided stroke treatment in the interventional suite is currently not possible. In this work, we present a novel approach that uses a C-arm angiography system capable of computed tomography (CT)-like imaging (C-arm CT) for this purpose. With C-arm CT one reconstructed volume can be obtained every 4-6 s which makes it challenging to measure the flow of an injected contrast bolus. We have developed an interleaved scanning (IS) protocol that uses several scan sequences to increase temporal sampling. Using a dedicated 4-D reconstruction approach based on partial reconstruction interpolation (PRI) we can optimally process our data. We evaluated our combined approach (IS-PRI) with simulations and a study in five healthy pigs. In our simulations, the cerebral blood flow values (unit: ml/100 g/min) were 60 (healthy tissue) and 20 (pathological tissue). For one scan sequence the values were estimated with standard deviations of 14.3 and 2.9, respectively. For two interleaved sequences the standard deviations decreased to 3.6 and 1.5, respectively. We used perfusion CT to validate the in vivo results. With two interleaved sequences we achieved promising correlations ranging from r=0.63 to r=0.94. The results suggest that C-arm CT tissue perfusion imaging is feasible with two interleaved scan sequences.Tissue perfusion measurement during catheter-guided stroke treatment in the interventional suite is currently not possible. In this work, we present a novel approach that uses a C-arm angiography system capable of computed tomography (CT)-like imaging (C-arm CT) for this purpose. With C-arm CT one reconstructed volume can be obtained every 4-6 s which makes it challenging to measure the flow of an injected contrast bolus. We have developed an interleaved scanning (IS) protocol that uses several scan sequences to increase temporal sampling. Using a dedicated 4-D reconstruction approach based on partial reconstruction interpolation (PRI) we can optimally process our data. We evaluated our combined approach (IS-PRI) with simulations and a study in five healthy pigs. In our simulations, the cerebral blood flow values (unit: ml/100 g/min) were 60 (healthy tissue) and 20 (pathological tissue). For one scan sequence the values were estimated with standard deviations of 14.3 and 2.9, respectively. For two interleaved sequences the standard deviations decreased to 3.6 and 1.5, respectively. We used perfusion CT to validate the in vivo results. With two interleaved sequences we achieved promising correlations ranging from r=0.63 to r=0.94. The results suggest that C-arm CT tissue perfusion imaging is feasible with two interleaved scan sequences.
Tissue perfusion measurement during catheter-guided stroke treatment in the interventional suite is currently not possible. In this work, we present a novel approach that uses a C-arm angiography system capable of computed tomography (CT)-like imaging (C-arm CT) for this purpose. With C-arm CT one reconstructed volume can be obtained every 4-6 s which makes it challenging to measure the flow of an injected contrast bolus. We have developed an interleaved scanning (IS) protocol that uses several scan sequences to increase temporal sampling. Using a dedicated 4-D reconstruction approach based on partial reconstruction interpolation (PRI) we can optimally process our data. We evaluated our combined approach (IS-PRI) with simulations and a study in five healthy pigs. In our simulations, the cerebral blood flow values (unit: ml/100 g/min) were 60 (healthy tissue) and 20 (pathological tissue). For one scan sequence the values were estimated with standard deviations of 14.3 and 2.9, respectively. For two interleaved sequences the standard deviations decreased to 3.6 and 1.5, respectively. We used perfusion CT to validate the in vivo results. With two interleaved sequences we achieved promising correlations ranging from r=0.63 to r=0.94. The results suggest that C-arm CT tissue perfusion imaging is feasible with two interleaved scan sequences.
Author Hornegger, J.
Fahrig, R.
Ganguly, A.
Rohkohl, C.
Deuerling-Zheng, Y.
Zellerhoff, M.
Fieselmann, A.
Boese, J.
Author_xml – sequence: 1
  givenname: A.
  surname: Fieselmann
  fullname: Fieselmann, A.
  email: andreas.fieselmann@informatik.uni-erlangen.de
  organization: Dept. of Comput. Sci., Friedrich-Alexander Univ. of Erlangen-Nuremberg, Erlangen, Germany
– sequence: 2
  givenname: A.
  surname: Ganguly
  fullname: Ganguly, A.
  organization: Dept. of Radiol., Stanford Univ., Palo Alto, CA, USA
– sequence: 3
  givenname: Y.
  surname: Deuerling-Zheng
  fullname: Deuerling-Zheng, Y.
  organization: Healthcare Sector, Siemens AG, Forchheim, Germany
– sequence: 4
  givenname: M.
  surname: Zellerhoff
  fullname: Zellerhoff, M.
  organization: Healthcare Sector, Siemens AG, Forchheim, Germany
– sequence: 5
  givenname: C.
  surname: Rohkohl
  fullname: Rohkohl, C.
  organization: Healthcare Sector, Siemens AG, Forchheim, Germany
– sequence: 6
  givenname: J.
  surname: Boese
  fullname: Boese, J.
  organization: Healthcare Sector, Siemens AG, Forchheim, Germany
– sequence: 7
  givenname: J.
  surname: Hornegger
  fullname: Hornegger, J.
  organization: Dept. of Comput. Sci., Friedrich-Alexander Univ. of Erlangen-Nuremberg, Erlangen, Germany
– sequence: 8
  givenname: R.
  surname: Fahrig
  fullname: Fahrig, R.
  organization: Dept. of Radiol., Stanford Univ., Palo Alto, CA, USA
BackLink https://www.ncbi.nlm.nih.gov/pubmed/22203707$$D View this record in MEDLINE/PubMed
BookMark eNp9kc1P2zAYh60JNEq3OxISym2nlPf1R2IfUbdBJSYQK9JukZu8QUGJU2wHaf_9krZw4DAfbNl-ntcfv1N25HpHjJ0hLBDBXK5_rRYcEBccNSqBn9gMldIpV_LPEZsBz3UKkPETdhrCMwBKBeYzO-Gcg8ghn7GXlYvkX8nFpne2TWT6PVmmV75Lluvknnw9hHEjWXX2qXFPyWOY-p3Tkn2lKvldWuemReuq5N762IxVHqjsXYh-KOPOnvht39pp9oUd17YN9PUwztnjzx_r5U16e3e9Wl7dpqVAHdOcSwSqUaFErUwJVWYy3ChSOVEuRW1A2ZyMRikkVRuAOqdNJaS2fLLEnH3b1936_mWgEIuuCSW1rXXUD6Ewhmuuxdjm7OJADpuOqmLrm876v8XbL40A7IHS9yF4qt8RhGIKohiDKKYgikMQo5J9UMom7t4fvW3a_4nne7EhovdzMsTxNkb8A2U5lFY
CODEN ITMID4
CitedBy_id crossref_primary_10_1002_mp_17870
crossref_primary_10_1088_0031_9155_57_22_7239
crossref_primary_10_1016_j_measen_2024_101211
crossref_primary_10_1007_s41365_021_00918_7
crossref_primary_10_1088_1361_6560_aac225
crossref_primary_10_1109_TMI_2019_2960720
crossref_primary_10_1002_mp_14514
crossref_primary_10_1007_s00234_019_02285_y
crossref_primary_10_1088_1361_6560_aab346
crossref_primary_10_1109_TMI_2013_2257178
crossref_primary_10_1177_1591019915622169
crossref_primary_10_1007_s00234_015_1545_1
crossref_primary_10_1097_MD_0000000000003529
crossref_primary_10_1118_1_4790467
crossref_primary_10_1088_0031_9155_59_16_4505
crossref_primary_10_1109_TMI_2012_2189153
crossref_primary_10_1118_1_4757910
Cites_doi 10.1088/0031-9155/55/8/014
10.1148/radiol.254082000
10.1118/1.3264619
10.3174/ajnr.A2518
10.1118/1.3589132
10.1007/s00330-008-1083-x
10.1117/12.844561
10.1118/1.3495818
10.1017/CBO9780511543241
10.1017/S1751731109004649
10.1136/neurintsurg-2011-010101
10.1002/mrm.22431
10.1007/978-0-387-92920-0_6
10.1155/2011/467563
10.1117/12.877658
10.1118/1.598939
10.1002/mrm.1910360510
10.1109/TMI.2006.876166
10.1118/1.2836423
10.1118/1.2746486
10.1118/1.2370508
10.1118/1.3180956
10.1109/TBME.2009.2013820
10.1137/0717021
10.1097/RLI.0b013e3181e1956f
10.1118/1.3130018
10.3174/ajnr.A0574
10.1109/ISBI.2010.5490417
10.1088/0031-9155/56/12/016
10.1118/1.3460318
10.1007/978-3-540-33125-4_3
10.1118/1.3560878
10.1364/JOSAA.1.000612
10.2174/157340510791268498
ContentType Journal Article
DBID 97E
RIA
RIE
AAYXX
CITATION
CGR
CUY
CVF
ECM
EIF
NPM
7X8
DOI 10.1109/TMI.2011.2181531
DatabaseName IEEE All-Society Periodicals Package (ASPP) 2005–Present
IEEE All-Society Periodicals Package (ASPP) 1998–Present
IEEE Electronic Library (IEL)
CrossRef
Medline
MEDLINE
MEDLINE (Ovid)
MEDLINE
MEDLINE
PubMed
MEDLINE - Academic
DatabaseTitle CrossRef
MEDLINE
Medline Complete
MEDLINE with Full Text
PubMed
MEDLINE (Ovid)
MEDLINE - Academic
DatabaseTitleList MEDLINE - Academic
MEDLINE

Database_xml – sequence: 1
  dbid: NPM
  name: PubMed
  url: http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed
  sourceTypes: Index Database
– sequence: 2
  dbid: RIE
  name: IEEE
  url: https://ieeexplore.ieee.org/
  sourceTypes: Publisher
– sequence: 3
  dbid: 7X8
  name: MEDLINE - Academic
  url: https://search.proquest.com/medline
  sourceTypes: Aggregation Database
DeliveryMethod fulltext_linktorsrc
Discipline Medicine
Engineering
EISSN 1558-254X
EndPage 906
ExternalDocumentID 22203707
10_1109_TMI_2011_2181531
6112229
Genre orig-research
Research Support, Non-U.S. Gov't
Journal Article
Research Support, N.I.H., Extramural
GrantInformation_xml – fundername: NIBIB NIH HHS
  grantid: 1K99EB007676
GroupedDBID ---
-DZ
-~X
.GJ
0R~
29I
4.4
53G
5GY
5RE
5VS
6IK
97E
AAJGR
AARMG
AASAJ
AAWTH
ABAZT
ABQJQ
ABVLG
ACGFO
ACGFS
ACIWK
ACNCT
ACPRK
AENEX
AETIX
AFRAH
AGQYO
AGSQL
AHBIQ
AI.
AIBXA
AKJIK
AKQYR
ALLEH
ALMA_UNASSIGNED_HOLDINGS
ASUFR
ATWAV
BEFXN
BFFAM
BGNUA
BKEBE
BPEOZ
CS3
DU5
EBS
EJD
F5P
HZ~
H~9
IBMZZ
ICLAB
IFIPE
IFJZH
IPLJI
JAVBF
LAI
M43
MS~
O9-
OCL
P2P
PQQKQ
RIA
RIE
RNS
RXW
TAE
TN5
VH1
AAYXX
CITATION
AAYOK
CGR
CUY
CVF
ECM
EIF
NPM
RIG
7X8
ID FETCH-LOGICAL-c318t-72410ef15141859c0d6961b5e57ee743f905a7e981434edb00f7ebd348a2f1513
IEDL.DBID RIE
ISICitedReferencesCount 31
ISICitedReferencesURI http://www.webofscience.com/api/gateway?GWVersion=2&SrcApp=Summon&SrcAuth=ProQuest&DestLinkType=CitingArticles&DestApp=WOS_CPL&KeyUT=000302547400005&url=https%3A%2F%2Fcvtisr.summon.serialssolutions.com%2F%23%21%2Fsearch%3Fho%3Df%26include.ft.matches%3Dt%26l%3Dnull%26q%3D
ISSN 0278-0062
1558-254X
IngestDate Sat Sep 27 18:05:08 EDT 2025
Thu Apr 03 07:08:48 EDT 2025
Tue Nov 18 22:35:36 EST 2025
Sat Nov 29 05:13:26 EST 2025
Tue Aug 26 17:19:20 EDT 2025
IsPeerReviewed false
IsScholarly true
Issue 4
Language English
License https://ieeexplore.ieee.org/Xplorehelp/downloads/license-information/IEEE.html
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-c318t-72410ef15141859c0d6961b5e57ee743f905a7e981434edb00f7ebd348a2f1513
Notes ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
PMID 22203707
PQID 992828333
PQPubID 23479
PageCount 15
ParticipantIDs crossref_primary_10_1109_TMI_2011_2181531
ieee_primary_6112229
pubmed_primary_22203707
crossref_citationtrail_10_1109_TMI_2011_2181531
proquest_miscellaneous_992828333
PublicationCentury 2000
PublicationDate 2012-April
2012-4-00
2012-Apr
20120401
PublicationDateYYYYMMDD 2012-04-01
PublicationDate_xml – month: 04
  year: 2012
  text: 2012-April
PublicationDecade 2010
PublicationPlace United States
PublicationPlace_xml – name: United States
PublicationTitle IEEE transactions on medical imaging
PublicationTitleAbbrev TMI
PublicationTitleAlternate IEEE Trans Med Imaging
PublicationYear 2012
Publisher IEEE
Publisher_xml – name: IEEE
References ref13
ref34
ref12
ref37
ref15
ref36
ref14
ref31
ref30
ref33
ref32
ref10
(ref1) 2006
ref39
ref38
ref16
ref19
maa (ref42) 2011; 7961
ref18
kudo (ref27) 2003; 24
ref24
ref26
ref25
chen (ref35) 2008; 6856
ref20
ref41
ref22
ref21
ref28
fieselmann (ref23) 2011
ref29
ref8
ref7
ref9
ref4
ref3
fieselmann (ref2) 2011
ref6
ref5
ref40
press (ref17) 2007
wintermark (ref11) 2004; 25
References_xml – ident: ref39
  doi: 10.1088/0031-9155/55/8/014
– ident: ref25
  doi: 10.1148/radiol.254082000
– year: 2011
  ident: ref2
  publication-title: Interventional perfusion imaging using C-arm computed tomography Algorithms and clinical evaluation
– ident: ref15
  doi: 10.1118/1.3264619
– volume: 24
  start-page: 419
  year: 2003
  ident: ref27
  article-title: Quantitative cerebral blood flow measurement with dynamic perfusion CT using the vascular-pixel elimination method: Comparison with <formula formulatype="inline"><tex Notation="TeX">${\rm H}_{2}^{15} {\rm O}$</tex></formula> positron emission tomography
  publication-title: Am J Neuroradiol
– ident: ref9
  doi: 10.3174/ajnr.A2518
– ident: ref33
  doi: 10.1118/1.3589132
– volume: 6856
  start-page: 685618
  year: 2008
  ident: ref35
  article-title: Prior image constrained compressed sensing (PICCS)
  publication-title: Proc SPIE Photons Plus Ultrasound Imag Sens
– ident: ref12
  doi: 10.1007/s00330-008-1083-x
– year: 2006
  ident: ref1
  publication-title: Acute Ischemic Stroke
– year: 2011
  ident: ref23
  publication-title: DIPPOA digital brain perfusion phantom
– ident: ref32
  doi: 10.1117/12.844561
– ident: ref4
  doi: 10.1118/1.3495818
– ident: ref19
  doi: 10.1017/CBO9780511543241
– ident: ref28
  doi: 10.1017/S1751731109004649
– ident: ref29
  doi: 10.1136/neurintsurg-2011-010101
– ident: ref22
  doi: 10.1002/mrm.22431
– ident: ref34
  doi: 10.1007/978-0-387-92920-0_6
– ident: ref13
  doi: 10.1155/2011/467563
– ident: ref24
  doi: 10.1117/12.877658
– year: 2007
  ident: ref17
  publication-title: Numerical Recipes
– ident: ref16
  doi: 10.1118/1.598939
– ident: ref20
  doi: 10.1002/mrm.1910360510
– ident: ref10
  doi: 10.1109/TMI.2006.876166
– ident: ref36
  doi: 10.1118/1.2836423
– ident: ref7
  doi: 10.1118/1.2746486
– ident: ref31
  doi: 10.1118/1.2370508
– ident: ref6
  doi: 10.1118/1.3180956
– ident: ref26
  doi: 10.1109/TBME.2009.2013820
– ident: ref18
  doi: 10.1137/0717021
– ident: ref30
  doi: 10.1097/RLI.0b013e3181e1956f
– ident: ref40
  doi: 10.1118/1.3130018
– volume: 25
  start-page: 720
  year: 2004
  ident: ref11
  article-title: Dynamic perfusion CT: Optimizing the temporal resolution and contrast volume for calculation of perfusion CT parameters in stroke patients
  publication-title: Am J Neuroradiol
– ident: ref21
  doi: 10.3174/ajnr.A0574
– ident: ref8
  doi: 10.1109/ISBI.2010.5490417
– ident: ref14
  doi: 10.1088/0031-9155/56/12/016
– ident: ref41
  doi: 10.1118/1.3460318
– ident: ref3
  doi: 10.1007/978-3-540-33125-4_3
– volume: 7961
  start-page: 79 611m1
  year: 2011
  ident: ref42
  article-title: Quantification of temporal resolution and its reliability in the context of TRI-PICCS and dual source CT
  publication-title: Proc SPIE Med Imag 2011 Phys Med Imag
– ident: ref38
  doi: 10.1118/1.3560878
– ident: ref5
  doi: 10.1364/JOSAA.1.000612
– ident: ref37
  doi: 10.2174/157340510791268498
SSID ssj0014509
Score 2.2313986
Snippet Tissue perfusion measurement during catheter-guided stroke treatment in the interventional suite is currently not possible. In this work, we present a novel...
SourceID proquest
pubmed
crossref
ieee
SourceType Aggregation Database
Index Database
Enrichment Source
Publisher
StartPage 892
SubjectTerms Angiography - methods
Animals
Brain - blood supply
Brain - diagnostic imaging
C-arm computed tomography (CT)
Cerebrovascular Circulation - physiology
Computed tomography
Computer Simulation
dynamic reconstruction
Image reconstruction
Interpolation
Legged locomotion
Models, Biological
perfusion imaging
Perfusion Imaging - methods
Phantoms, Imaging
Protocols
Radiographic Image Enhancement - methods
Reconstruction algorithms
Reproducibility of Results
stroke treatment
Swine
Tomography, X-Ray Computed - methods
Title Interventional 4-D C-Arm CT Perfusion Imaging Using Interleaved Scanning and Partial Reconstruction Interpolation
URI https://ieeexplore.ieee.org/document/6112229
https://www.ncbi.nlm.nih.gov/pubmed/22203707
https://www.proquest.com/docview/992828333
Volume 31
WOSCitedRecordID wos000302547400005&url=https%3A%2F%2Fcvtisr.summon.serialssolutions.com%2F%23%21%2Fsearch%3Fho%3Df%26include.ft.matches%3Dt%26l%3Dnull%26q%3D
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
journalDatabaseRights – providerCode: PRVIEE
  databaseName: IEEE
  customDbUrl:
  eissn: 1558-254X
  dateEnd: 99991231
  omitProxy: false
  ssIdentifier: ssj0014509
  issn: 0278-0062
  databaseCode: RIE
  dateStart: 19820101
  isFulltext: true
  titleUrlDefault: https://ieeexplore.ieee.org/
  providerName: IEEE
link http://cvtisr.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwlV1RT9swED4BmqbtgW3AtjKG_LCXScsaHCe2H1EBUWmgSuukvkWJfZGQIGW05ffvzk6zPgykveXB50T57nRn3913AF8wq5Rxlu0bTaLwxCXGOJlgYZWvjffOhUbhH_r62sxmdrIF3_peGEQMxWf4nR9DLt_P3YqvyoYFBQdS2m3Y1lrHXq0-Y6DyWM4hmTE2LeQ6JZna4fRqHLk62Z2RzjEBsJRppnmG7IY3CuNVno40g8e5ePN_3_oWdrvIUpxGVXgHW9juwesNvsE9eHnVZdL34fd4o9iRxFRyJkYJwS5GUzHBh2bF12hifBemGIlQWSCCzC1Wj-jFTxenHYmq9WLCCki78GH2LyVtXH8_j-V2B_Dr4nw6uky68QuJI0NfJpqce4oNhQRMcGNd6gtbnNQ55hqRAo_Gpnml0RoKuRR6st9GY-0zZSrJUtl72GnnLX4EITnXL2VN8RCqxkvrjUubXNdaYV35YgDDNQyl67jJeUTGbRnOKKktCcOSMSw7DAfwtZe4j7wcz6zdZ3z6dR00AxBrpEuyKU6UVC3OV4vSWj6IZlk2gA9RA3rZteIc_nvPT_CK3ixjac8R7NAPx8_wwj0ubxYPx6S3M3Mc9PYPZV3mbw
linkProvider IEEE
linkToHtml http://cvtisr.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwlV1Lb9swDCa6bljbw_pIH-nWVYddBtSNI8u2dCyyFQ2WBAGWAb0ZtkQDBVqnjyS_v6LkuDl0BXrzQRQEfyRIieRHgB8Y5UJqRfaNMhDY1YGUmgeYKGEKaYzWrlF4kI5G8vpajdfgrOmFQURXfIbn9Oly-Waq5_RU1klscMC5-gAfYyF413drNTkDEfuCDk6csWHCl0nJUHUmw75n6ySHZrWOKIA5D6OUpsiu-CM3YOX_sabzOZfb7zvtDnypY0t24ZVhF9aw2oOtFcbBPfg8rHPpLXjor5Q7WjER_GK9wALPehM2xsdyTg9prH_n5hgxV1vAnMwt5gs07K_2845YXhk2JhW0u9B19oWU1q-_n_qCu334d_l70rsK6gEMgbamPgtS695DLG1QQBQ3SocmUUm3iDFOEW3oUaowzlNU0gZdAo214DLFwkRC5pykogNYr6YVHgHjlO3nvLAREYrScGWkDss4LVKBRW6SNnSWMGS6ZienIRm3mbulhCqzGGaEYVZj2IafjcS9Z-Z4Y22L8GnW1dC0gS2RzqxVUaokr3A6f8qUoqtoFEVtOPQa0MguFef49T1PYeNqMhxkg_7oz1fYtKfgvtDnG6zbn48n8EkvZjdPj9-d9j4DG23ozg
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Interventional+4-D+C-Arm+CT+Perfusion+Imaging+Using+Interleaved+Scanning+and+Partial+Reconstruction+Interpolation&rft.jtitle=IEEE+transactions+on+medical+imaging&rft.au=Fieselmann%2C+Andreas&rft.au=Ganguly%2C+Arundhuti&rft.au=Deuerling-Zheng%2C+Yu&rft.au=Zellerhoff%2C+Michael&rft.date=2012-04-01&rft.issn=0278-0062&rft.eissn=1558-254X&rft.volume=31&rft.issue=4&rft.spage=892&rft.epage=906&rft_id=info:doi/10.1109%2FTMI.2011.2181531&rft.externalDBID=n%2Fa&rft.externalDocID=10_1109_TMI_2011_2181531
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0278-0062&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0278-0062&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0278-0062&client=summon