Dynamic modelling and simulation of a slinky-coil horizontal ground heat exchanger using Modelica

Ground source heat pumps are attractive alternatives for both conventional heating and cooling systems because of their higher energy efficiencies. A ground source heat pump system consists of a conventional heat pump coupled with a ground heat exchanger where water or a water-antifreeze mixture exc...

Full description

Saved in:
Bibliographic Details
Published in:Journal of Building Engineering Vol. 16; pp. 159 - 168
Main Authors: Sangi, Roozbeh, Müller, Dirk
Format: Journal Article
Language:English
Published: Elsevier Ltd 01.03.2018
Subjects:
ISSN:2352-7102, 2352-7102
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Ground source heat pumps are attractive alternatives for both conventional heating and cooling systems because of their higher energy efficiencies. A ground source heat pump system consists of a conventional heat pump coupled with a ground heat exchanger where water or a water-antifreeze mixture exchanges heat with the ground. Several major design options are available for ground heat exchangers, which are classified by layout to open and closed loops. Closed loop tubing can be installed horizontally as a loop field in trenches or vertically as a series of long U-shapes in wells. Slinky-coil horizontal ground heat exchangers are a compromise between vertical ground heat exchangers and conventional horizontal ground heat exchangers. They combine the relatively small installation cost of conventional horizontal ground heat exchangers and the high heat exchange capacity of vertical ground heat exchangers. These traits make a slinky-coil horizontal ground heat exchanger a suitable alternative for space heating in areas with limitations on land space usage. However, caused by a lack of appropriate dimensioning tools, these systems are often undersized or overdesigned. In this research, the feasibility of modelling and simulation of slinky-coil geothermal heat exchangers in the modelling language Modelica has been demonstrated. A model of a slinky-coil horizontal ground heat exchanger has been developed to simulate the performance of such systems. The model includes a ground heat exchanger and a soil cell. The ground heat exchanger has been modelled in two levels of detail, one with coil-like pipes and one with thin plates instead of pipes. In order to be able to assess the validity of the model, it has been developed based on a field test in Japan, and simulated under the same conditions. Reasonably good agreement has been obtained between the numerical predictions and published experimental measurements, which demonstrates the reliability and accuracy of the model.
ISSN:2352-7102
2352-7102
DOI:10.1016/j.jobe.2018.01.005