Accelerated 3D multi‐channel B1+ mapping at 7 T for the brain and heart
PurposeTo acquire accurate volumetric multi‐channel B1+$$ {\mathrm{B}}_1^{+} $$ maps in under 14 s whole‐brain or 23 heartbeats whole‐heart for parallel transmit (pTx) applications at 7 T.Theory and MethodsWe evaluate the combination of three recently proposed techniques. The acquisition of multi‐ch...
Uloženo v:
| Vydáno v: | Magnetic resonance in medicine Ročník 92; číslo 5; s. 2007 - 2020 |
|---|---|
| Hlavní autoři: | , , , , , |
| Médium: | Journal Article |
| Jazyk: | angličtina |
| Vydáno: |
Hoboken
Wiley Subscription Services, Inc
01.11.2024
|
| Témata: | |
| ISSN: | 0740-3194, 1522-2594 |
| On-line přístup: | Získat plný text |
| Tagy: |
Přidat tag
Žádné tagy, Buďte první, kdo vytvoří štítek k tomuto záznamu!
|
| Shrnutí: | PurposeTo acquire accurate volumetric multi‐channel B1+$$ {\mathrm{B}}_1^{+} $$ maps in under 14 s whole‐brain or 23 heartbeats whole‐heart for parallel transmit (pTx) applications at 7 T.Theory and MethodsWe evaluate the combination of three recently proposed techniques. The acquisition of multi‐channel transmit array B1+$$ {\mathrm{B}}_1^{+} $$ maps is accelerated using transmit low rank (TxLR) with absolute B1+$$ {\mathrm{B}}_1^{+} $$ mapping (Sandwich) acquired in a B1+$$ {\mathrm{B}}_1^{+} $$ time‐interleaved acquisition of modes (B1TIAMO) fashion. Simulations using synthetic body images derived from Sim4Life were used to test the achievable acceleration for small scan matrices of 24 × 24. Next, we evaluated the method by retrospectively undersampling a fully sampled B1+$$ {\mathrm{B}}_1^{+} $$ library of nine subjects in the brain. Finally, Cartesian undersampled phantom and in vivo images were acquired in both the brain of three subjects (8Tx/32 receive [Rx]) and the heart of another three subjects (8Tx/8Rx) at 7 T.ResultsSimulation and in vivo results show that volumetric multi‐channel B1+$$ {\mathrm{B}}_1^{+} $$ maps can be acquired using acceleration factors of 4 in the body, reducing the acquisition time to within 23 heartbeats, which was previously not possible. In silico heart simulations demonstrated a RMS error to the fully sampled native resolution ground truth of 4.2° when combined in first‐order circularly polarized mode (mean flip angle 66°) at an acceleration factor of 4. The 14 s 3D B1+$$ {\mathrm{B}}_1^{+} $$ maps acquired in the brain have a RMS error of 1.9° to the fully sampled (mean flip angle 86°).ConclusionThe proposed method is demonstrated as a fast pTx calibration technique in the brain and a promising method for pTx calibration in the body. |
|---|---|
| Bibliografie: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 14 |
| ISSN: | 0740-3194 1522-2594 |
| DOI: | 10.1002/mrm.30201 |