Performance characteristics of respirable parallel particle impactors (PPI)

Parallel Particle Impactors (PPIs) for respirable aerosols were introduced by SKC Inc. approximately 10 years ago and have been applied in the field; however, their collection efficiency curves have not yet been published. PPI consists of four impactors with different 50% cutoff sizes (d ) arranged...

Full description

Saved in:
Bibliographic Details
Published in:Journal of occupational and environmental hygiene pp. 1 - 18
Main Authors: Mainelis, Gediminas, Han, Taewon T.
Format: Journal Article
Language:English
Published: England 18.07.2025
Subjects:
ISSN:1545-9624, 1545-9632, 1545-9632
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Abstract Parallel Particle Impactors (PPIs) for respirable aerosols were introduced by SKC Inc. approximately 10 years ago and have been applied in the field; however, their collection efficiency curves have not yet been published. PPI consists of four impactors with different 50% cutoff sizes (d ) arranged in parallel, and their resulting performance is designed to follow the convention for respiratory aerosol sampling. This study investigated the collection efficiency curves and d values of disposable and reusable PPI models designed to operate at flow rates of 2, 4, and 8 L/min. The samplers were challenged with polydisperse sodium chloride (NaCl) particles and select sizes of polystyrene latex (PSL) particles. Bias maps and Bias Performance Criterion (BPC) values were calculated for challenge aerosols with mass median aerodynamic diameters (MMADs) ranging from 1 to 25 µm and geometric standard deviations (GSDs) ranging from 1.75 to 3.5. Results showed that 2, 4, and 8 L/min disposable PPI models had d values close to 4 µm, with minimal bias compared to an ideal respirable sampler, and an average BPC exceeding 95%. The reusable 2 L/min model also closely followed the respirable convention, with a d of 4.07 µm and a BPC of 100%. However, the d for the reusable 4 L/min and 8 L/min units was slightly higher, at 4.27 µm. ∼7% increase in the sampling flow rate to 4.3 L/min resulted in the d of ∼4 µm, with a BPC of 100%. Overall, the respirable PPI samplers, particularly their disposable models, show excellent adherence to the respirable aerosol sampling convention and contribute to the arsenal of tools for estimating exposures to respirable particles. The availability of PPI samplers operating at different flow rates offers flexibility in selecting a suitable sampler model based on available personal sampling pumps, anticipated concentrations of the respirable aerosol fraction, and desired sampling times.
AbstractList Parallel Particle Impactors (PPIs) for respirable aerosols were introduced by SKC Inc. approximately 10 years ago and have been applied in the field; however, their collection efficiency curves have not yet been published. PPI consists of four impactors with different 50% cutoff sizes (d ) arranged in parallel, and their resulting performance is designed to follow the convention for respiratory aerosol sampling. This study investigated the collection efficiency curves and d values of disposable and reusable PPI models designed to operate at flow rates of 2, 4, and 8 L/min. The samplers were challenged with polydisperse sodium chloride (NaCl) particles and select sizes of polystyrene latex (PSL) particles. Bias maps and Bias Performance Criterion (BPC) values were calculated for challenge aerosols with mass median aerodynamic diameters (MMADs) ranging from 1 to 25 µm and geometric standard deviations (GSDs) ranging from 1.75 to 3.5. Results showed that 2, 4, and 8 L/min disposable PPI models had d values close to 4 µm, with minimal bias compared to an ideal respirable sampler, and an average BPC exceeding 95%. The reusable 2 L/min model also closely followed the respirable convention, with a d of 4.07 µm and a BPC of 100%. However, the d for the reusable 4 L/min and 8 L/min units was slightly higher, at 4.27 µm. ∼7% increase in the sampling flow rate to 4.3 L/min resulted in the d of ∼4 µm, with a BPC of 100%. Overall, the respirable PPI samplers, particularly their disposable models, show excellent adherence to the respirable aerosol sampling convention and contribute to the arsenal of tools for estimating exposures to respirable particles. The availability of PPI samplers operating at different flow rates offers flexibility in selecting a suitable sampler model based on available personal sampling pumps, anticipated concentrations of the respirable aerosol fraction, and desired sampling times.
Parallel Particle Impactors (PPIs) for respirable aerosols were introduced by SKC Inc. approximately 10 years ago and have been applied in the field; however, their collection efficiency curves have not yet been published. PPI consists of four impactors with different 50% cutoff sizes (d50) arranged in parallel, and their resulting performance is designed to follow the convention for respiratory aerosol sampling. This study investigated the collection efficiency curves and d50 values of disposable and reusable PPI models designed to operate at flow rates of 2, 4, and 8 L/min. The samplers were challenged with polydisperse sodium chloride (NaCl) particles and select sizes of polystyrene latex (PSL) particles. Bias maps and Bias Performance Criterion (BPC) values were calculated for challenge aerosols with mass median aerodynamic diameters (MMADs) ranging from 1 to 25 µm and geometric standard deviations (GSDs) ranging from 1.75 to 3.5. Results showed that 2, 4, and 8 L/min disposable PPI models had d50 values close to 4 µm, with minimal bias compared to an ideal respirable sampler, and an average BPC exceeding 95%. The reusable 2 L/min model also closely followed the respirable convention, with a d50 of 4.07 µm and a BPC of 100%. However, the d50 for the reusable 4 L/min and 8 L/min units was slightly higher, at 4.27 µm. A ∼7% increase in the sampling flow rate to 4.3 L/min resulted in the d50 of ∼4 µm, with a BPC of 100%. Overall, the respirable PPI samplers, particularly their disposable models, show excellent adherence to the respirable aerosol sampling convention and contribute to the arsenal of tools for estimating exposures to respirable particles. The availability of PPI samplers operating at different flow rates offers flexibility in selecting a suitable sampler model based on available personal sampling pumps, anticipated concentrations of the respirable aerosol fraction, and desired sampling times.Parallel Particle Impactors (PPIs) for respirable aerosols were introduced by SKC Inc. approximately 10 years ago and have been applied in the field; however, their collection efficiency curves have not yet been published. PPI consists of four impactors with different 50% cutoff sizes (d50) arranged in parallel, and their resulting performance is designed to follow the convention for respiratory aerosol sampling. This study investigated the collection efficiency curves and d50 values of disposable and reusable PPI models designed to operate at flow rates of 2, 4, and 8 L/min. The samplers were challenged with polydisperse sodium chloride (NaCl) particles and select sizes of polystyrene latex (PSL) particles. Bias maps and Bias Performance Criterion (BPC) values were calculated for challenge aerosols with mass median aerodynamic diameters (MMADs) ranging from 1 to 25 µm and geometric standard deviations (GSDs) ranging from 1.75 to 3.5. Results showed that 2, 4, and 8 L/min disposable PPI models had d50 values close to 4 µm, with minimal bias compared to an ideal respirable sampler, and an average BPC exceeding 95%. The reusable 2 L/min model also closely followed the respirable convention, with a d50 of 4.07 µm and a BPC of 100%. However, the d50 for the reusable 4 L/min and 8 L/min units was slightly higher, at 4.27 µm. A ∼7% increase in the sampling flow rate to 4.3 L/min resulted in the d50 of ∼4 µm, with a BPC of 100%. Overall, the respirable PPI samplers, particularly their disposable models, show excellent adherence to the respirable aerosol sampling convention and contribute to the arsenal of tools for estimating exposures to respirable particles. The availability of PPI samplers operating at different flow rates offers flexibility in selecting a suitable sampler model based on available personal sampling pumps, anticipated concentrations of the respirable aerosol fraction, and desired sampling times.
Author Han, Taewon T.
Mainelis, Gediminas
Author_xml – sequence: 1
  givenname: Gediminas
  surname: Mainelis
  fullname: Mainelis, Gediminas
– sequence: 2
  givenname: Taewon T.
  surname: Han
  fullname: Han, Taewon T.
BackLink https://www.ncbi.nlm.nih.gov/pubmed/40680244$$D View this record in MEDLINE/PubMed
BookMark eNo9kMtOwzAQRS0Eog_4BFCWZZHid-IlqnhUVKILWFuuMxFBThzsdMHf46iP1VzNPRqNzgxddr4DhO4IXhJc4kciuFCS8iXFVCypICUuyAWajvtcSUYvz5nyCZrF-IMxlYTJazThWJaYcj5F71sItQ-t6Sxk9tsEYwcITRwaGzNfZwFi3wSzc5D1qXQO3BhSnTZN2yfch5gtttv1ww26qo2LcHucc_T18vy5ess3H6_r1dMmt1SoIaeV4JYzqbAiXNSCsJLXWGAlypKxwhpj2M4KI6uiqpSVRXoaGAbOFQFVMzZHi8PdPvjfPcRBt0204JzpwO-jZpQRQQkRZULvj-h-10Kl-9C0Jvzpk4AEiANgg48xQH1GCNajaH0SrUfR-iia_QOeH25H
Cites_doi 10.1088/1742-6596/151/1/012060
10.1080/08828032.1986.10390497
10.1186/1743-8977-10-12
10.1093/annhyg/meq050
10.1177/14680874241274039
10.3390/ijerph18136819
10.1080/15459624.2020.1868481
10.1080/00028899908984479
10.1080/15428119891010938
10.1080/15459620701763723
10.1016/S0003-4878(98)00031-3
10.1016/j.envsci.2024.103715
10.1016/0021-8502(94)00131-H
10.1080/15298668391405940
10.1016/j.scitotenv.2021.152657
10.1002/ajim.23451
10.1201/9781003069867-4
10.3390/ijerph17061923
10.1093/annweh/wxx057
10.3390/ijerph20032429
10.1093/annhyg/mev097
10.1093/annweh/wxad012
10.1186/s12940-023-01036-0
10.3390/ijerph17186820
10.1016/0021-8502(78)90072-1
10.1016/s0003-4878(00)00014-4
ContentType Journal Article
DBID AAYXX
CITATION
NPM
7X8
DOI 10.1080/15459624.2025.2518071
DatabaseName CrossRef
PubMed
MEDLINE - Academic
DatabaseTitle CrossRef
PubMed
MEDLINE - Academic
DatabaseTitleList PubMed
MEDLINE - Academic
Database_xml – sequence: 1
  dbid: NPM
  name: PubMed
  url: http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed
  sourceTypes: Index Database
– sequence: 2
  dbid: 7X8
  name: MEDLINE - Academic
  url: https://search.proquest.com/medline
  sourceTypes: Aggregation Database
DeliveryMethod fulltext_linktorsrc
Discipline Medicine
EISSN 1545-9632
EndPage 18
ExternalDocumentID 40680244
10_1080_15459624_2025_2518071
Genre Journal Article
GroupedDBID ---
-~X
.7F
.QJ
04C
0BK
0R~
29L
30N
36B
4.4
5GY
5RE
5VS
6PF
85S
AAENE
AAGDL
AAHIA
AAJMT
AALDU
AAMIU
AAPUL
AAQRR
AAWTL
AAYXX
ABCCY
ABFIM
ABLIJ
ABPAQ
ABPEM
ABTAI
ABXUL
ABXYU
ACGEJ
ACGFS
ACGOD
ACIWK
ACPRK
ACTIO
ADBBV
ADCVX
ADGTB
ADOJX
ADXPE
AEISY
AENEX
AEOZL
AEPSL
AEYOC
AFRAH
AFRVT
AGDLA
AGMYJ
AHDZW
AHMBA
AIJEM
AIYEW
AJWEG
AKBVH
AKOOK
ALMA_UNASSIGNED_HOLDINGS
ALQZU
AQRUH
AVBZW
AWYRJ
BLEHA
BMSDO
CCCUG
CE4
CITATION
CS3
DGEBU
DKSSO
DU5
EBS
ECT
EDH
E~A
E~B
F5P
GTTXZ
H13
HF~
HZ~
H~P
IPNFZ
J.P
KYCEM
LJTGL
M4Z
NA5
O9-
PQQKQ
RIG
RNANH
ROSJB
RTWRZ
S-T
SNACF
TASJS
TBQAZ
TDBHL
TEI
TEN
TFL
TFT
TFW
TQWBC
TTHFI
TUROJ
TWF
TWQ
UT3
UT5
UU3
ZGOLN
~S~
ADYSH
AFOSN
NPM
7X8
ID FETCH-LOGICAL-c259t-2d54c436909145f51384f0509588337caaa3bc5a6d7dd9c67613e30e4491e9f33
ISICitedReferencesCount 0
ISICitedReferencesURI http://www.webofscience.com/api/gateway?GWVersion=2&SrcApp=Summon&SrcAuth=ProQuest&DestLinkType=CitingArticles&DestApp=WOS_CPL&KeyUT=001531040000001&url=https%3A%2F%2Fcvtisr.summon.serialssolutions.com%2F%23%21%2Fsearch%3Fho%3Df%26include.ft.matches%3Dt%26l%3Dnull%26q%3D
ISSN 1545-9624
1545-9632
IngestDate Fri Sep 05 15:41:51 EDT 2025
Sun Jul 20 01:30:48 EDT 2025
Sat Nov 29 07:44:33 EST 2025
IsPeerReviewed true
IsScholarly true
Keywords bias map
50% cutoff diameter
collection efficiency
chamber study
respirable sampler
Aerosol sampling
Language English
LinkModel OpenURL
MergedId FETCHMERGED-LOGICAL-c259t-2d54c436909145f51384f0509588337caaa3bc5a6d7dd9c67613e30e4491e9f33
Notes ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
PMID 40680244
PQID 3231521158
PQPubID 23479
PageCount 18
ParticipantIDs proquest_miscellaneous_3231521158
pubmed_primary_40680244
crossref_primary_10_1080_15459624_2025_2518071
PublicationCentury 2000
PublicationDate 2025-Jul-18
PublicationDateYYYYMMDD 2025-07-18
PublicationDate_xml – month: 07
  year: 2025
  text: 2025-Jul-18
  day: 18
PublicationDecade 2020
PublicationPlace England
PublicationPlace_xml – name: England
PublicationTitle Journal of occupational and environmental hygiene
PublicationTitleAlternate J Occup Environ Hyg
PublicationYear 2025
References ACGIH (e_1_3_4_2_1) 2001
e_1_3_4_4_1
Görner P (e_1_3_4_11_1) 1996; 3
e_1_3_4_9_1
Lidén G (e_1_3_4_21_1) 1992; 36
e_1_3_4_8_1
e_1_3_4_7_1
e_1_3_4_6_1
e_1_3_4_5_1
e_1_3_4_23_1
e_1_3_4_24_1
e_1_3_4_22_1
e_1_3_4_27_1
e_1_3_4_28_1
e_1_3_4_25_1
e_1_3_4_26_1
ASTM International (e_1_3_4_3_1) 2012
e_1_3_4_29_1
Courbon, P, Wrobel R, Fabries J-F. (e_1_3_4_10_1) 1988; 32
Stacey P (e_1_3_4_32_1) 2010
e_1_3_4_31_1
e_1_3_4_30_1
e_1_3_4_12_1
e_1_3_4_35_1
e_1_3_4_13_1
e_1_3_4_34_1
e_1_3_4_33_1
e_1_3_4_16_1
Hinds WC. (e_1_3_4_17_1) 1999
e_1_3_4_14_1
e_1_3_4_37_1
e_1_3_4_15_1
Jones WG. (e_1_3_4_18_1) 1987
e_1_3_4_36_1
Leidel NA. (e_1_3_4_20_1) 1977
e_1_3_4_19_1
References_xml – ident: e_1_3_4_35_1
  doi: 10.1088/1742-6596/151/1/012060
– ident: e_1_3_4_34_1
  doi: 10.1080/08828032.1986.10390497
– volume: 36
  start-page: 1
  issue: 1
  year: 1992
  ident: e_1_3_4_21_1
  article-title: The performance of respirable dust samplers: Sampler bias, precision and inaccuracy
  publication-title: Ann Occup Hyg
– volume-title: Testing of high flow rate respirable samplers to assess the technical feasibility of measuring 0.05 mg m-1 respirable crystalline silica
  year: 2010
  ident: e_1_3_4_32_1
– ident: e_1_3_4_5_1
  doi: 10.1186/1743-8977-10-12
– ident: e_1_3_4_19_1
  doi: 10.1093/annhyg/meq050
– start-page: 77
  volume-title: Occupational exposure sampling strategy manual
  year: 1977
  ident: e_1_3_4_20_1
– volume-title: Air sampling instruments for evaluation of atmospheric contaminants
  year: 2001
  ident: e_1_3_4_2_1
– ident: e_1_3_4_14_1
  doi: 10.1177/14680874241274039
– ident: e_1_3_4_15_1
  doi: 10.3390/ijerph18136819
– ident: e_1_3_4_8_1
  doi: 10.1080/15459624.2020.1868481
– ident: e_1_3_4_6_1
  doi: 10.1080/00028899908984479
– ident: e_1_3_4_7_1
  doi: 10.1080/15428119891010938
– volume-title: Aerosol technology: properties, behavior, and measurement of airborne particles
  year: 1999
  ident: e_1_3_4_17_1
– volume-title: Design and calibration of a multi-purpose aerosol sampler
  year: 1987
  ident: e_1_3_4_18_1
– ident: e_1_3_4_22_1
  doi: 10.1080/15459620701763723
– ident: e_1_3_4_4_1
  doi: 10.1016/S0003-4878(98)00031-3
– volume: 3
  start-page: 361
  issue: 6
  year: 1996
  ident: e_1_3_4_11_1
  article-title: Industrial aerosol measurement according to the new sampling conventions
  publication-title: Occup Hyg
– ident: e_1_3_4_23_1
  doi: 10.1016/j.envsci.2024.103715
– ident: e_1_3_4_26_1
  doi: 10.1016/0021-8502(94)00131-H
– ident: e_1_3_4_25_1
  doi: 10.1080/15298668391405940
– ident: e_1_3_4_29_1
– volume: 32
  start-page: 129
  issue: 1
  year: 1988
  ident: e_1_3_4_10_1
  article-title: A new individual respirable dust sampler: The CIP 10
  publication-title: Ann Occup Hyg
– ident: e_1_3_4_31_1
  doi: 10.1016/j.scitotenv.2021.152657
– ident: e_1_3_4_27_1
  doi: 10.1002/ajim.23451
– ident: e_1_3_4_36_1
  doi: 10.1201/9781003069867-4
– ident: e_1_3_4_28_1
  doi: 10.3390/ijerph17061923
– ident: e_1_3_4_12_1
  doi: 10.1093/annweh/wxx057
– ident: e_1_3_4_37_1
  doi: 10.3390/ijerph20032429
– start-page: 9
  volume-title: Standard practice for evaluating the performance of respirable aerosol samplers
  year: 2012
  ident: e_1_3_4_3_1
– ident: e_1_3_4_33_1
  doi: 10.1093/annhyg/mev097
– ident: e_1_3_4_9_1
  doi: 10.1093/annweh/wxad012
– ident: e_1_3_4_30_1
  doi: 10.1186/s12940-023-01036-0
– ident: e_1_3_4_16_1
  doi: 10.3390/ijerph17186820
– ident: e_1_3_4_24_1
  doi: 10.1016/0021-8502(78)90072-1
– ident: e_1_3_4_13_1
  doi: 10.1016/s0003-4878(00)00014-4
SSID ssj0026136
Score 2.384499
SecondaryResourceType online_first
Snippet Parallel Particle Impactors (PPIs) for respirable aerosols were introduced by SKC Inc. approximately 10 years ago and have been applied in the field; however,...
SourceID proquest
pubmed
crossref
SourceType Aggregation Database
Index Database
StartPage 1
Title Performance characteristics of respirable parallel particle impactors (PPI)
URI https://www.ncbi.nlm.nih.gov/pubmed/40680244
https://www.proquest.com/docview/3231521158
WOSCitedRecordID wos001531040000001&url=https%3A%2F%2Fcvtisr.summon.serialssolutions.com%2F%23%21%2Fsearch%3Fho%3Df%26include.ft.matches%3Dt%26l%3Dnull%26q%3D
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
journalDatabaseRights – providerCode: PRVAWR
  databaseName: Taylor & Francis Journals
  customDbUrl:
  eissn: 1545-9632
  dateEnd: 99991231
  omitProxy: false
  ssIdentifier: ssj0026136
  issn: 1545-9624
  databaseCode: TFW
  dateStart: 20040101
  isFulltext: true
  titleUrlDefault: https://www.tandfonline.com
  providerName: Taylor & Francis
link http://cvtisr.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwtV1Lj9MwEB51F4S4IN6Ux8pIHOCQkIcdx0eEWJCA1R4K9Ba5trNCqtKq7S7Lv2cmjtNsFxB7QJWiyFImqWc08814HgAvklqjEdImyqQVEVcJj7R26KXUVua2djZtA25fP8mjo3I6Vcej0TLUwpzNZdOU5-dq-V9ZjWvIbCqdvQK7e6K4gPfIdLwi2_H6T4w_HpQCmJ12zIgMV_5snQqmqO33fO7mdNOS6Womaf4OAk_0-EOc4DJ6XQy7E1PwfVAxR-WVP09QZwzyahHMdpPX36O5pPyb9Vb5-QnJ2v1AUZzEw0BEJijCeVF3chGpwpdEx2641oUwvY5MB8bWP39Jjfu8R3qY6MX0thiBWJnIdGu3wln9jjnrkwzTrvtpIFMRmaojswfXMikU6cHJ4bfeRUdw09ajhb8Sar7K5PVvv-YimvmDi9JClcltuNVxib3xTL0DI9fchRufuyyKe_BxICJsR0TYomZbEWFBRFgQEdaLCHuJAvLqPnw5fDd5-yHqhmpEBj3dTZRZwQ3PC4VAkYtapHnJa2oCJGjstDRa63xmhC6stFaZQhYUJ08c5yp1qs7zB7DfLBr3CJi1Nkf8WWepSTifoaeBvxk1jENYbRM3hjhsTrX0vVOqvzJlDM_DFlao5ejoSjducbqucnRDEGimohzDQ7-3PUlO42MQpT6-6uuewM2tHD-F_c3q1D2D6-Zs8329OoA9OS0PWvH4BWYUdqg
linkProvider Taylor & Francis
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Performance+characteristics+of+respirable+parallel+particle+impactors+%28PPI%29&rft.jtitle=Journal+of+occupational+and+environmental+hygiene&rft.au=Mainelis%2C+Gediminas&rft.au=Han%2C+Taewon+T.&rft.date=2025-07-18&rft.issn=1545-9624&rft.eissn=1545-9632&rft.spage=1&rft.epage=18&rft_id=info:doi/10.1080%2F15459624.2025.2518071&rft.externalDBID=n%2Fa&rft.externalDocID=10_1080_15459624_2025_2518071
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1545-9624&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1545-9624&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1545-9624&client=summon