Verification and Establishment of Reference Intervals for Prothrombin Time and Activated Partial Thromboplastin Time for Children in a Clinical Laboratory
Prothrombin time (PT) and activated partial thromboplastin time (aPTT) are routine coagulation tests. The absence of age-dependent reference interval (RI) may lead to abnormal results in children. In this study, we aimed to verify adult-based RIs in children and establish pediatric RIs for PT and aP...
Uloženo v:
| Vydáno v: | Clinical laboratory (Heidelberg) Ročník 68; číslo 2 |
|---|---|
| Hlavní autoři: | , , , |
| Médium: | Journal Article |
| Jazyk: | angličtina |
| Vydáno: |
Germany
01.01.2022
|
| Témata: | |
| ISSN: | 1433-6510 |
| On-line přístup: | Zjistit podrobnosti o přístupu |
| Tagy: |
Přidat tag
Žádné tagy, Buďte první, kdo vytvoří štítek k tomuto záznamu!
|
| Shrnutí: | Prothrombin time (PT) and activated partial thromboplastin time (aPTT) are routine coagulation tests. The absence of age-dependent reference interval (RI) may lead to abnormal results in children. In this study, we aimed to verify adult-based RIs in children and establish pediatric RIs for PT and aPTT.
We analyzed PT and aPTT results. Samples from inpatients and outpatients aged 1 - 18 years, considered healthy subjects, were divided into six groups by age. Verification and establishment of RIs were conducted.
Applying adult-based RIs to pediatrics was statistically invalid for individuals aged 10 - 18 years for PT and invalid throughout childhood for aPTT. The new RI of PT for individuals aged 10 - 18 years was 11.1 - 14.1 seconds and that of aPTT for individuals aged 1 - 9 years was 28.2 - 46.0 seconds.
Pediatric RIs were higher than adult-based RIs. Using pediatric RI can save time, labor, and costs to make clinical decision. |
|---|---|
| Bibliografie: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
| ISSN: | 1433-6510 |
| DOI: | 10.7754/Clin.Lab.2021.210539 |