Dermal exposure and surface contamination associated with the use of a cobalt-chrome alloy during additive manufacturing

Amidst the rapidly emerging additive manufacturing (AM) industry, not enough attention has been given to dermal exposure, with only one previous study that assessed dermal exposure to metals. Our study aimed to characterise a cobalt (Co)-chrome (Cr) alloy feedstock powder (CO-538) in terms of partic...

Full description

Saved in:
Bibliographic Details
Published in:Annals of work exposures and health Vol. 69; no. 5; p. 486
Main Authors: Paulse, Lynicka, du Preez, Sonette, Franken, Anja, du Plessis, Johan
Format: Journal Article
Language:English
Published: England 30.06.2025
Subjects:
ISSN:2398-7316, 2398-7316
Online Access:Get more information
Tags: Add Tag
No Tags, Be the first to tag this record!
Abstract Amidst the rapidly emerging additive manufacturing (AM) industry, not enough attention has been given to dermal exposure, with only one previous study that assessed dermal exposure to metals. Our study aimed to characterise a cobalt (Co)-chrome (Cr) alloy feedstock powder (CO-538) in terms of particle size, shape, and elemental composition, and assess dermal exposure and workplace surface contamination during powder bed fusion AM. Particle size distribution (PSD) and shape of the virgin and used feedstock powder were determined using static image and scanning electron microscopy analyses. The elemental composition of powders was established using inductively coupled plasma-optical emission spectrometry. A removal wipe sampling method using Ghostwipes was performed on AM operators' skin at various locations (index finger, palm, wrist, back of the hand, and neck), before and after each AM processing phase. Workplace surfaces (both AM and non-AM areas) were also sampled before and after each shift using a removal wipe method to measure surface contamination. PSD analysis revealed a significant difference (P ≤ 0.05) in median size, with used powder exhibiting smaller particles than virgin, where 10% of particles were smaller than the given diameter. Additionally, significant differences (P ≤ 0.05) were noted in the mean circularity and convexity between virgin and used powders, indicating that used powder particles were more irregular and rougher compared to virgin. The CO-538 feedstock powder contained Co, Cr, molybdenum (Mo), aluminium (Al), iron (Fe), and Ni. These metals were also detected on the skin of AM operators and on surfaces within the AM and non-AM areas of the facility. Dermal exposure occurred on all of the anatomical areas, with the highest total metal concentration detected on the index finger during the post-processing phase of AM. The highest full-shift geometric mean GM concentration of each metal was detected on the finger and followed a trend of Co > Cr > Fe > Al > Mo > Ni. Surface contamination occurred on all AM and non-AM sampling areas after a full shift. Dermal exposure to all CO-538 alloy metal constituents occurred on all sampled anatomical areas during all three processing phases. Measurable concentrations of metals that were detected on all sampled surfaces indicate that cross-contamination between AM and non-AM areas occurs and that these surfaces may act as a secondary source of exposure. There is thus a need for control measures to be implemented in AM facilities to eliminate or reduce surface metal contamination and dermal exposure.
AbstractList Amidst the rapidly emerging additive manufacturing (AM) industry, not enough attention has been given to dermal exposure, with only one previous study that assessed dermal exposure to metals. Our study aimed to characterise a cobalt (Co)-chrome (Cr) alloy feedstock powder (CO-538) in terms of particle size, shape, and elemental composition, and assess dermal exposure and workplace surface contamination during powder bed fusion AM.BACKGROUNDAmidst the rapidly emerging additive manufacturing (AM) industry, not enough attention has been given to dermal exposure, with only one previous study that assessed dermal exposure to metals. Our study aimed to characterise a cobalt (Co)-chrome (Cr) alloy feedstock powder (CO-538) in terms of particle size, shape, and elemental composition, and assess dermal exposure and workplace surface contamination during powder bed fusion AM.Particle size distribution (PSD) and shape of the virgin and used feedstock powder were determined using static image and scanning electron microscopy analyses. The elemental composition of powders was established using inductively coupled plasma-optical emission spectrometry. A removal wipe sampling method using Ghostwipes was performed on AM operators' skin at various locations (index finger, palm, wrist, back of the hand, and neck), before and after each AM processing phase. Workplace surfaces (both AM and non-AM areas) were also sampled before and after each shift using a removal wipe method to measure surface contamination.METHODSParticle size distribution (PSD) and shape of the virgin and used feedstock powder were determined using static image and scanning electron microscopy analyses. The elemental composition of powders was established using inductively coupled plasma-optical emission spectrometry. A removal wipe sampling method using Ghostwipes was performed on AM operators' skin at various locations (index finger, palm, wrist, back of the hand, and neck), before and after each AM processing phase. Workplace surfaces (both AM and non-AM areas) were also sampled before and after each shift using a removal wipe method to measure surface contamination.PSD analysis revealed a significant difference (P ≤ 0.05) in median size, with used powder exhibiting smaller particles than virgin, where 10% of particles were smaller than the given diameter. Additionally, significant differences (P ≤ 0.05) were noted in the mean circularity and convexity between virgin and used powders, indicating that used powder particles were more irregular and rougher compared to virgin. The CO-538 feedstock powder contained Co, Cr, molybdenum (Mo), aluminium (Al), iron (Fe), and Ni. These metals were also detected on the skin of AM operators and on surfaces within the AM and non-AM areas of the facility. Dermal exposure occurred on all of the anatomical areas, with the highest total metal concentration detected on the index finger during the post-processing phase of AM. The highest full-shift geometric mean GM concentration of each metal was detected on the finger and followed a trend of Co > Cr > Fe > Al > Mo > Ni. Surface contamination occurred on all AM and non-AM sampling areas after a full shift.RESULTSPSD analysis revealed a significant difference (P ≤ 0.05) in median size, with used powder exhibiting smaller particles than virgin, where 10% of particles were smaller than the given diameter. Additionally, significant differences (P ≤ 0.05) were noted in the mean circularity and convexity between virgin and used powders, indicating that used powder particles were more irregular and rougher compared to virgin. The CO-538 feedstock powder contained Co, Cr, molybdenum (Mo), aluminium (Al), iron (Fe), and Ni. These metals were also detected on the skin of AM operators and on surfaces within the AM and non-AM areas of the facility. Dermal exposure occurred on all of the anatomical areas, with the highest total metal concentration detected on the index finger during the post-processing phase of AM. The highest full-shift geometric mean GM concentration of each metal was detected on the finger and followed a trend of Co > Cr > Fe > Al > Mo > Ni. Surface contamination occurred on all AM and non-AM sampling areas after a full shift.Dermal exposure to all CO-538 alloy metal constituents occurred on all sampled anatomical areas during all three processing phases. Measurable concentrations of metals that were detected on all sampled surfaces indicate that cross-contamination between AM and non-AM areas occurs and that these surfaces may act as a secondary source of exposure. There is thus a need for control measures to be implemented in AM facilities to eliminate or reduce surface metal contamination and dermal exposure.CONCLUSIONSDermal exposure to all CO-538 alloy metal constituents occurred on all sampled anatomical areas during all three processing phases. Measurable concentrations of metals that were detected on all sampled surfaces indicate that cross-contamination between AM and non-AM areas occurs and that these surfaces may act as a secondary source of exposure. There is thus a need for control measures to be implemented in AM facilities to eliminate or reduce surface metal contamination and dermal exposure.
Amidst the rapidly emerging additive manufacturing (AM) industry, not enough attention has been given to dermal exposure, with only one previous study that assessed dermal exposure to metals. Our study aimed to characterise a cobalt (Co)-chrome (Cr) alloy feedstock powder (CO-538) in terms of particle size, shape, and elemental composition, and assess dermal exposure and workplace surface contamination during powder bed fusion AM. Particle size distribution (PSD) and shape of the virgin and used feedstock powder were determined using static image and scanning electron microscopy analyses. The elemental composition of powders was established using inductively coupled plasma-optical emission spectrometry. A removal wipe sampling method using Ghostwipes was performed on AM operators' skin at various locations (index finger, palm, wrist, back of the hand, and neck), before and after each AM processing phase. Workplace surfaces (both AM and non-AM areas) were also sampled before and after each shift using a removal wipe method to measure surface contamination. PSD analysis revealed a significant difference (P ≤ 0.05) in median size, with used powder exhibiting smaller particles than virgin, where 10% of particles were smaller than the given diameter. Additionally, significant differences (P ≤ 0.05) were noted in the mean circularity and convexity between virgin and used powders, indicating that used powder particles were more irregular and rougher compared to virgin. The CO-538 feedstock powder contained Co, Cr, molybdenum (Mo), aluminium (Al), iron (Fe), and Ni. These metals were also detected on the skin of AM operators and on surfaces within the AM and non-AM areas of the facility. Dermal exposure occurred on all of the anatomical areas, with the highest total metal concentration detected on the index finger during the post-processing phase of AM. The highest full-shift geometric mean GM concentration of each metal was detected on the finger and followed a trend of Co > Cr > Fe > Al > Mo > Ni. Surface contamination occurred on all AM and non-AM sampling areas after a full shift. Dermal exposure to all CO-538 alloy metal constituents occurred on all sampled anatomical areas during all three processing phases. Measurable concentrations of metals that were detected on all sampled surfaces indicate that cross-contamination between AM and non-AM areas occurs and that these surfaces may act as a secondary source of exposure. There is thus a need for control measures to be implemented in AM facilities to eliminate or reduce surface metal contamination and dermal exposure.
Author Franken, Anja
Paulse, Lynicka
du Preez, Sonette
du Plessis, Johan
Author_xml – sequence: 1
  givenname: Lynicka
  surname: Paulse
  fullname: Paulse, Lynicka
  organization: Occupational Hygiene and Health Research Initiative (OHHRI), North-West University, Potchefstroom Campus, Private Bag X6001, Potchefstroom 2520, South Africa
– sequence: 2
  givenname: Sonette
  orcidid: 0000-0002-7468-3874
  surname: du Preez
  fullname: du Preez, Sonette
  organization: Occupational Hygiene and Health Research Initiative (OHHRI), North-West University, Potchefstroom Campus, Private Bag X6001, Potchefstroom 2520, South Africa
– sequence: 3
  givenname: Anja
  orcidid: 0000-0001-9774-4759
  surname: Franken
  fullname: Franken, Anja
  organization: Occupational Hygiene and Health Research Initiative (OHHRI), North-West University, Potchefstroom Campus, Private Bag X6001, Potchefstroom 2520, South Africa
– sequence: 4
  givenname: Johan
  orcidid: 0000-0001-5122-8492
  surname: du Plessis
  fullname: du Plessis, Johan
  organization: Occupational Hygiene and Health Research Initiative (OHHRI), North-West University, Potchefstroom Campus, Private Bag X6001, Potchefstroom 2520, South Africa
BackLink https://www.ncbi.nlm.nih.gov/pubmed/40407035$$D View this record in MEDLINE/PubMed
BookMark eNpNkDtPwzAUhS1UREvpyog8soT6kcTJiMpTqsQCc3Rj31CjxC6xQ9t_TwRFYjpHR5--4ZyTifMOCbnk7IazUi7BuR1ulrs9NIyXJ2QmZFkkSvJ88q9PySKED8YYV1kqZX5GpilLmWIym5H9HfYdtBT3Wx-GHik4Q8fSgEaqvYvQWQfRekchBK8tRDR0Z-OGxg3SISD1DYURraGNid70vhslbesP1Ay9de8UjLHRfiHtwA2jN_7MF-S0gTbg4phz8vZw_7p6StYvj8-r23WiRSZiglwiqNqYFHQGeS5UnWGtSkTOZG6KJi0ZNFjyTOQFV8iLRipRcsikhrwsxJxc_3q3vf8cMMSqs0Fj24JDP4RKCjZixSge0asjOtQdmmrb2w76Q_X3lvgGByFyWQ
ContentType Journal Article
Copyright The Author(s) 2025. Published by Oxford University Press on behalf of the British Occupational Hygiene Society. All rights reserved. For commercial re-use, please contact reprints@oup.com for reprints and translation rights for reprints. All other permissions can be obtained through our RightsLink service via the Permissions link on the article page on our site—for further information please contact journals.permissions@oup.com.
Copyright_xml – notice: The Author(s) 2025. Published by Oxford University Press on behalf of the British Occupational Hygiene Society. All rights reserved. For commercial re-use, please contact reprints@oup.com for reprints and translation rights for reprints. All other permissions can be obtained through our RightsLink service via the Permissions link on the article page on our site—for further information please contact journals.permissions@oup.com.
DBID CGR
CUY
CVF
ECM
EIF
NPM
7X8
DOI 10.1093/annweh/wxaf019
DatabaseName Medline
MEDLINE
MEDLINE (Ovid)
MEDLINE
MEDLINE
PubMed
MEDLINE - Academic
DatabaseTitle MEDLINE
Medline Complete
MEDLINE with Full Text
PubMed
MEDLINE (Ovid)
MEDLINE - Academic
DatabaseTitleList MEDLINE - Academic
MEDLINE
Database_xml – sequence: 1
  dbid: NPM
  name: PubMed
  url: http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed
  sourceTypes: Index Database
– sequence: 2
  dbid: 7X8
  name: MEDLINE - Academic
  url: https://search.proquest.com/medline
  sourceTypes: Aggregation Database
DeliveryMethod no_fulltext_linktorsrc
Discipline Medicine
EISSN 2398-7316
ExternalDocumentID 40407035
Genre Journal Article
GrantInformation_xml – fundername: South African Department of Science and Innovation
GroupedDBID 04C
0R~
48X
53G
5WD
AABZA
AACZT
AAFWJ
AAIMJ
AAPQZ
AAPXW
AARHZ
AAUAY
AAVAP
ABDFA
ABEJV
ABGNP
ABJNI
ABMNT
ABNHQ
ABPQP
ABPTD
ABVGC
ABWST
ABXVV
ABXZS
ACUFI
ADBBV
ADEZT
ADGKP
ADGZP
ADHKW
ADIPN
ADNBA
ADQBN
ADRTK
ADVEK
ADYVW
AEKSI
AELWJ
AEMDU
AENZO
AETBJ
AEWNT
AFFZL
AFGWE
AFOFC
AGINJ
AGORE
AGQXC
AHGBF
AHMMS
AJBYB
AJEEA
AJNCP
ALMA_UNASSIGNED_HOLDINGS
ALXQX
APIBT
APWMN
ARIXL
ATGXG
BAYMD
BCRHZ
BMSDO
BSWAC
BTRTY
CDBKE
CGR
CUY
CVF
EBS
ECM
EIF
FHSFR
FLUFQ
FOEOM
FOTVD
GAUVT
H13
JXSIZ
KOP
KSI
KSN
NLBLG
NOMLY
NOYVH
NPM
O9-
OBOKY
OCZFY
ODMLO
OJZSN
OPAEJ
OVD
PAFKI
PEELM
ROL
ROX
RUSNO
TJX
TLC
YAYTL
YKOAZ
YXANX
7X8
I-F
ID FETCH-LOGICAL-c252t-e13ea7bdd4ac5a6627b5eb79ee1036d8f490afe91526817e18f37291a53ca6982
IEDL.DBID 7X8
ISICitedReferencesCount 0
ISICitedReferencesURI http://www.webofscience.com/api/gateway?GWVersion=2&SrcApp=Summon&SrcAuth=ProQuest&DestLinkType=CitingArticles&DestApp=WOS_CPL&KeyUT=001493936800001&url=https%3A%2F%2Fcvtisr.summon.serialssolutions.com%2F%23%21%2Fsearch%3Fho%3Df%26include.ft.matches%3Dt%26l%3Dnull%26q%3D
ISSN 2398-7316
IngestDate Thu Oct 02 22:46:32 EDT 2025
Thu Jul 03 03:58:33 EDT 2025
IsPeerReviewed true
IsScholarly true
Issue 5
Keywords skin
powder bed fusion
CO-538
Ghostwipes
3D printing
molybdenum
Language English
License The Author(s) 2025. Published by Oxford University Press on behalf of the British Occupational Hygiene Society. All rights reserved. For commercial re-use, please contact reprints@oup.com for reprints and translation rights for reprints. All other permissions can be obtained through our RightsLink service via the Permissions link on the article page on our site—for further information please contact journals.permissions@oup.com.
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-c252t-e13ea7bdd4ac5a6627b5eb79ee1036d8f490afe91526817e18f37291a53ca6982
Notes ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ORCID 0000-0002-7468-3874
0000-0001-9774-4759
0000-0001-5122-8492
PMID 40407035
PQID 3206988627
PQPubID 23479
ParticipantIDs proquest_miscellaneous_3206988627
pubmed_primary_40407035
PublicationCentury 2000
PublicationDate 2025-Jun-30
PublicationDateYYYYMMDD 2025-06-30
PublicationDate_xml – month: 06
  year: 2025
  text: 2025-Jun-30
  day: 30
PublicationDecade 2020
PublicationPlace England
PublicationPlace_xml – name: England
PublicationTitle Annals of work exposures and health
PublicationTitleAlternate Ann Work Expo Health
PublicationYear 2025
SSID ssj0001754336
Score 2.29651
Snippet Amidst the rapidly emerging additive manufacturing (AM) industry, not enough attention has been given to dermal exposure, with only one previous study that...
SourceID proquest
pubmed
SourceType Aggregation Database
Index Database
StartPage 486
SubjectTerms Alloys
Chromium - analysis
Chromium Alloys - adverse effects
Chromium Alloys - analysis
Cobalt - analysis
Humans
Microscopy, Electron, Scanning
Occupational Exposure - analysis
Particle Size
Powders
Skin - chemistry
Surface Properties
Title Dermal exposure and surface contamination associated with the use of a cobalt-chrome alloy during additive manufacturing
URI https://www.ncbi.nlm.nih.gov/pubmed/40407035
https://www.proquest.com/docview/3206988627
Volume 69
WOSCitedRecordID wos001493936800001&url=https%3A%2F%2Fcvtisr.summon.serialssolutions.com%2F%23%21%2Fsearch%3Fho%3Df%26include.ft.matches%3Dt%26l%3Dnull%26q%3D
hasFullText
inHoldings 1
isFullTextHit
isPrint
link http://cvtisr.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwpV1LS8NAEF7Uinjx_agvVvC6NMkm2eQkohYvLT0o9BYmm1kq1KSa1tZ_706S2pMgeAkhJBB2JjNfZma_j7GbAB0FRnvCk1IKXxkQFmWgMBpDYzMShJBWYhOq34-Gw3jQFNzKZqxyGROrQJ0VmmrkHek5YRxZ_K1uJ--CVKOou9pIaKyzlrRQhrxaDaNVjUUFvpS1vhzRZko3_OFtlKTzMsdRZ74AUxHt_IYwq0zT3f3vO-6xnQZj8rvaKfbZGuYHbKvXdNEP2eKBwvGY42JSUIGQQ55xe2JAI6fZdaD5GLIYh8Z6mHGq2HILF_msRF4YDvbWFMZToUdEecCpg__F622PnMaUKJDyN8hntHmiunzEXrqPz_dPolFgENoLvKlAVyKoNMt80AEQV3waYKpiRNdmviwyfuyAwdgl0hhXoRsZagO6EEgNdim8Y7aRFzmeMh4Tj42jtcU_6AeOSY1xUof0sDT9g0KbXS_XNLEeTm0LyLGYlclqVdvspDZMMqmpOBLfxiAbs4KzPzx9zrY9Eu-thv0uWMvY7xsv2ab-nL6WH1eV69hjf9D7Bm7_0ZY
linkProvider ProQuest
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Dermal+exposure+and+surface+contamination+associated+with+the+use+of+a+cobalt-chrome+alloy+during+additive+manufacturing&rft.jtitle=Annals+of+work+exposures+and+health&rft.au=Paulse%2C+Lynicka&rft.au=du+Preez%2C+Sonette&rft.au=Franken%2C+Anja&rft.au=du+Plessis%2C+Johan&rft.date=2025-06-30&rft.eissn=2398-7316&rft.volume=69&rft.issue=5&rft.spage=486&rft_id=info:doi/10.1093%2Fannweh%2Fwxaf019&rft_id=info%3Apmid%2F40407035&rft_id=info%3Apmid%2F40407035&rft.externalDocID=40407035
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=2398-7316&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=2398-7316&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=2398-7316&client=summon