Optimization of monitoring systems power cable lines

RELEVANCE. The length and complexity of the geography of medium voltage cable lines is at a high level. Such lines extend underground, on supports in the air. In order to constantly maintain the reliability of city power supply at a high level, any interruptions and accidents should be promptly corr...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Izvestiâ vysših učebnyh zavedenij. Problemy ènergetiki Jg. 26; H. 4; S. 89 - 99
Hauptverfasser: Balobanov, R. N., Bulatova, V. M., Kryuchkov, N. S., Shafikov, I. I.
Format: Journal Article
Sprache:Englisch
Veröffentlicht: Kazan State Power Engineering University 23.09.2024
Schlagworte:
ISSN:1998-9903, 2658-5456
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Abstract RELEVANCE. The length and complexity of the geography of medium voltage cable lines is at a high level. Such lines extend underground, on supports in the air. In order to constantly maintain the reliability of city power supply at a high level, any interruptions and accidents should be promptly corrected. TARGET. The main goal of the work is to develop the theory of medium voltage CL research, to practically and theoretically substantiate the search for the most convenient and effective installation for CL diagnostics, to study and develop possible modifications of CL diagnostic installations. METHODS. A variant of CL diagnostics based on the CPDA-60 installation is proposed, which makes it possible to find and localize the places where defects occur in the insulation based on the measurement and analysis of partial discharges (PD). Suitable for insulation monitoring in all types of high voltage cables. The CPDA installation can be used when testing new cable lines being put into operation, and to analyze the condition of old cables in operation. RESULTS. Cable lines require an integrated approach to diagnostics and monitoring, since the reliability of modern authentication systems for the generation and distribution of electricity is largely determined by the electrical reliability of electrical equipment. Technical diagnostics of equipment is a key link, the quality of which determines the efficiency of the processes of organizing production activities, strategic planning and renovation of electric grid assets. CONCLUSION. The study and analysis of the presented data and research allows us to form a conclusion regarding the method of measuring and localizing partial discharges (PD) in power cable lines (CL) using the Online Wire Testing System (OWTS) diagnostic system. The OWTS system allows real-time measurements without interrupting cable lines, making it especially valuable to the energy industry. Thanks to the introduction of advanced technologies and signal processing algorithms, the method has high accuracy and sensitivity to minimal manifestations of private discharges, which allows not only to detect, but also to accurately localize the location of defects in the insulation. The use of this method can significantly increase the service life of power cables, reduce the likelihood of sudden accidents and, as a result, reduce the cost of repair and maintenance of electrical power equipment. Ultimately, improvements in diagnostic and monitoring techniques, including the method of measuring and localizing PD in power lines using OWTS, represent a significant step towards improving the reliability and safety of electrical power systems. This will not only reduce operating costs, but also ensure uninterrupted and high-quality power supply to consumers.
AbstractList RELEVANCE. The length and complexity of the geography of medium voltage cable lines is at a high level. Such lines extend underground, on supports in the air. In order to constantly maintain the reliability of city power supply at a high level, any interruptions and accidents should be promptly corrected.TARGET. The main goal of the work is to develop the theory of medium voltage CL research, to practically and theoretically substantiate the search for the most convenient and effective installation for CL diagnostics, to study and develop possible modifications of CL diagnostic installations.METHODS. A variant of CL diagnostics based on the CPDA-60 installation is proposed, which makes it possible to find and localize the places where defects occur in the insulation based on the measurement and analysis of partial discharges (PD). Suitable for insulation monitoring in all types of high voltage cables. The CPDA installation can be used when testing new cable lines being put into operation, and to analyze the condition of old cables in operation.RESULTS. Cable lines require an integrated approach to diagnostics and monitoring, since the reliability of modern authentication systems for the generation and distribution of electricity is largely determined by the electrical reliability of electrical equipment. Technical diagnostics of equipment is a key link, the quality of which determines the efficiency of the processes of organizing production activities, strategic planning and renovation of electric grid assets.CONCLUSION. The study and analysis of the presented data and research allows us to form a conclusion regarding the method of measuring and localizing partial discharges (PD) in power cable lines (CL) using the Online Wire Testing System (OWTS) diagnostic system. The OWTS system allows real-time measurements without interrupting cable lines, making it especially valuable to the energy industry. Thanks to the introduction of advanced technologies and signal processing algorithms, the method has high accuracy and sensitivity to minimal manifestations of private discharges, which allows not only to detect, but also to accurately localize the location of defects in the insulation. The use of this method can significantly increase the service life of power cables, reduce the likelihood of sudden accidents and, as a result, reduce the cost of repair and maintenance of electrical power equipment. Ultimately, improvements in diagnostic and monitoring techniques, including the method of measuring and localizing PD in power lines using OWTS, represent a significant step towards improving the reliability and safety of electrical power systems. This will not only reduce operating costs, but also ensure uninterrupted and high-quality power supply to consumers.
RELEVANCE. The length and complexity of the geography of medium voltage cable lines is at a high level. Such lines extend underground, on supports in the air. In order to constantly maintain the reliability of city power supply at a high level, any interruptions and accidents should be promptly corrected. TARGET. The main goal of the work is to develop the theory of medium voltage CL research, to practically and theoretically substantiate the search for the most convenient and effective installation for CL diagnostics, to study and develop possible modifications of CL diagnostic installations. METHODS. A variant of CL diagnostics based on the CPDA-60 installation is proposed, which makes it possible to find and localize the places where defects occur in the insulation based on the measurement and analysis of partial discharges (PD). Suitable for insulation monitoring in all types of high voltage cables. The CPDA installation can be used when testing new cable lines being put into operation, and to analyze the condition of old cables in operation. RESULTS. Cable lines require an integrated approach to diagnostics and monitoring, since the reliability of modern authentication systems for the generation and distribution of electricity is largely determined by the electrical reliability of electrical equipment. Technical diagnostics of equipment is a key link, the quality of which determines the efficiency of the processes of organizing production activities, strategic planning and renovation of electric grid assets. CONCLUSION. The study and analysis of the presented data and research allows us to form a conclusion regarding the method of measuring and localizing partial discharges (PD) in power cable lines (CL) using the Online Wire Testing System (OWTS) diagnostic system. The OWTS system allows real-time measurements without interrupting cable lines, making it especially valuable to the energy industry. Thanks to the introduction of advanced technologies and signal processing algorithms, the method has high accuracy and sensitivity to minimal manifestations of private discharges, which allows not only to detect, but also to accurately localize the location of defects in the insulation. The use of this method can significantly increase the service life of power cables, reduce the likelihood of sudden accidents and, as a result, reduce the cost of repair and maintenance of electrical power equipment. Ultimately, improvements in diagnostic and monitoring techniques, including the method of measuring and localizing PD in power lines using OWTS, represent a significant step towards improving the reliability and safety of electrical power systems. This will not only reduce operating costs, but also ensure uninterrupted and high-quality power supply to consumers.
Author Balobanov, R. N.
Shafikov, I. I.
Bulatova, V. M.
Kryuchkov, N. S.
Author_xml – sequence: 1
  givenname: R. N.
  surname: Balobanov
  fullname: Balobanov, R. N.
  organization: Kazan State Power Engineering University
– sequence: 2
  givenname: V. M.
  surname: Bulatova
  fullname: Bulatova, V. M.
  organization: Kazan State Power Engineering University
– sequence: 3
  givenname: N. S.
  surname: Kryuchkov
  fullname: Kryuchkov, N. S.
  organization: Kazan State Power Engineering University
– sequence: 4
  givenname: I. I.
  surname: Shafikov
  fullname: Shafikov, I. I.
  organization: Kazan State Power Engineering University
BookMark eNo9kEtLAzEURoNUsNb-h8F9NI-bzMSdFB-FQje6Dpk8SsrMpCQDUn-9nVa6unC4HD7OPZoNafAIPVLyxEnN4Jkq1WClCMeMMMBMYsCNOpEbNGdSNFiAkDM0v_7doWUpe0IIa2qgop4j2B7G2MdfM8Y0VClUfRrimHIcdlU5ltH3pTqkH58ra9rOV10cfHlAt8F0xS__7wJ9v799rT7xZvuxXr1usKVSKeyoV0K0vg2BQ-2dEg6sl4ZNe6yDxjvDCDFS2gYc5URJb0kwDACIM44v0Pridcns9SHH3uSjTibqM0h5p00eo-28bgUnvKYOICiwRBjDgqxr4NQaaII_uV4uLptTKdmHq48Sfc6pp1l6yqSnnJpJDbpRJ8L_AAiuapU
Cites_doi 10.1016/j.measurement.2023.112882
10.1016/j.epsr.2023.109452
10.1007/s00202-023-01935-y
10.25206/1813-8225-2020-174-63-68
10.14529/power230401
10.18799/24131830/2024/3/4209
10.3390/s24082660
10.3390/en17051142
ContentType Journal Article
DBID AAYXX
CITATION
DOA
DOI 10.30724/1998-9903-2024-26-4-89-99
DatabaseName CrossRef
DOAJ Directory of Open Access Journals
DatabaseTitle CrossRef
DatabaseTitleList
CrossRef
Database_xml – sequence: 1
  dbid: DOA
  name: DOAJ Directory of Open Access Journals
  url: https://www.doaj.org/
  sourceTypes: Open Website
DeliveryMethod fulltext_linktorsrc
Discipline Engineering
EISSN 2658-5456
EndPage 99
ExternalDocumentID oai_doaj_org_article_b530371d44f94c05aa2f677431ca48fe
10_30724_1998_9903_2024_26_4_89_99
GroupedDBID AAYXX
ALMA_UNASSIGNED_HOLDINGS
CITATION
GROUPED_DOAJ
ID FETCH-LOGICAL-c1699-d1e955bebff347ed95d4ce6a21998cd48eda200a66c84d13096ec0fa24440dad3
IEDL.DBID DOA
ISSN 1998-9903
IngestDate Fri Oct 03 12:39:57 EDT 2025
Sat Nov 29 04:03:36 EST 2025
IsDoiOpenAccess true
IsOpenAccess true
IsPeerReviewed true
IsScholarly true
Issue 4
Language English
License https://www.energyret.ru/jour/about/editorialPolicies#openAccessPolicy
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-c1699-d1e955bebff347ed95d4ce6a21998cd48eda200a66c84d13096ec0fa24440dad3
OpenAccessLink https://doaj.org/article/b530371d44f94c05aa2f677431ca48fe
PageCount 11
ParticipantIDs doaj_primary_oai_doaj_org_article_b530371d44f94c05aa2f677431ca48fe
crossref_primary_10_30724_1998_9903_2024_26_4_89_99
PublicationCentury 2000
PublicationDate 2024-09-23
PublicationDateYYYYMMDD 2024-09-23
PublicationDate_xml – month: 09
  year: 2024
  text: 2024-09-23
  day: 23
PublicationDecade 2020
PublicationTitle Izvestiâ vysših učebnyh zavedenij. Problemy ènergetiki
PublicationYear 2024
Publisher Kazan State Power Engineering University
Publisher_xml – name: Kazan State Power Engineering University
References ref13
ref12
ref15
ref14
ref20
ref11
ref10
ref2
ref1
ref17
ref16
ref19
ref18
ref8
ref7
ref9
ref4
ref3
ref6
ref5
References_xml – ident: ref2
– ident: ref3
– ident: ref20
  doi: 10.1016/j.measurement.2023.112882
– ident: ref5
– ident: ref6
– ident: ref13
  doi: 10.1016/j.epsr.2023.109452
– ident: ref16
  doi: 10.1007/s00202-023-01935-y
– ident: ref4
  doi: 10.25206/1813-8225-2020-174-63-68
– ident: ref1
  doi: 10.14529/power230401
– ident: ref7
  doi: 10.18799/24131830/2024/3/4209
– ident: ref19
  doi: 10.3390/s24082660
– ident: ref9
– ident: ref8
– ident: ref18
– ident: ref14
  doi: 10.3390/en17051142
– ident: ref10
– ident: ref17
– ident: ref11
  doi: 10.1016/j.measurement.2023.112882
– ident: ref12
– ident: ref15
SSID ssj0002874157
Score 2.268536
Snippet RELEVANCE. The length and complexity of the geography of medium voltage cable lines is at a high level. Such lines extend underground, on supports in the air....
RELEVANCE. The length and complexity of the geography of medium voltage cable lines is at a high level. Such lines extend underground, on supports in the air....
SourceID doaj
crossref
SourceType Open Website
Index Database
StartPage 89
SubjectTerms cable line
diagnostics
insulation
partial discharges
power industry
testing
Title Optimization of monitoring systems power cable lines
URI https://doaj.org/article/b530371d44f94c05aa2f677431ca48fe
Volume 26
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
journalDatabaseRights – providerCode: PRVAON
  databaseName: DOAJ Directory of Open Access Journals
  customDbUrl:
  eissn: 2658-5456
  dateEnd: 20241231
  omitProxy: false
  ssIdentifier: ssj0002874157
  issn: 1998-9903
  databaseCode: DOA
  dateStart: 20150101
  isFulltext: true
  titleUrlDefault: https://www.doaj.org/
  providerName: Directory of Open Access Journals
link http://cvtisr.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwrV07T8MwELZQxQAD4inKSx5YrSbx2bFHQFRMhQGkbpbjhwRSH2oLvx-fE0o2FlZHcey7831nO_cdIbelCMnpScE0cMnA-ZppLRSLspZOqhBFU-RiE_VkoqZT_dIr9YX_hLX0wK3gRo3gyCrnAaIGVwhrq9QP4h7ycceA3jdFPb3N1Ec-MkKkzJVVMIcsuVzeMo4mk65gtG1MRlIBq9IomdIsE8D-olOPxD-jzfiQHHRhIr1rh3dEdsL8mOz3yANPCDyn1T7r0ijpItJZXp74kLb8zGu6xBpo1GF6FMV4cn1K3saPrw9PrKuBwFwptWa-DFqIJjQxcqiD18KDC9JWOAXnQQVvk6FbKZ0CnwBJy-CKaBNqQ-Gt52dkMF_MwzmhtW9soaCyurRgi7rREqlipGvwcjXyIeE_czfLlurCpC1ClpjBzxmUmEGJmUoaMEqnliG5RzFt30C66tyQlGg6JZq_lHjxH51ckr2sTbwy4ldksFl9hmuy67427-vVTbaPbzK6uPM
linkProvider Directory of Open Access Journals
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Optimization+of+monitoring+systems+power+cable+lines&rft.jtitle=Izvesti%C3%A2+vys%C5%A1ih+u%C4%8Debnyh+zavedenij.+Problemy+%C3%A8nergetiki&rft.au=R.+N.+Balobanov&rft.au=V.+M.+Bulatova&rft.au=N.+S.+Kryuchkov&rft.au=I.+I.+Shafikov&rft.date=2024-09-23&rft.pub=Kazan+State+Power+Engineering+University&rft.issn=1998-9903&rft.volume=26&rft.issue=4&rft.spage=89&rft.epage=99&rft_id=info:doi/10.30724%2F1998-9903-2024-26-4-89-99&rft.externalDBID=DOA&rft.externalDocID=oai_doaj_org_article_b530371d44f94c05aa2f677431ca48fe
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1998-9903&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1998-9903&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1998-9903&client=summon