Demagnetization Faults Robust Detection Method Based on an Adaptive Sliding Mode Observer for PMSM

To detect demagnetization faults in real time based on an adaptive sliding mode observer, we used a permanent-magnet synchronous motor (PMSM). Demagnetization faults are first modeled for the PMSM using coordinates oriented to the magnetic field. To solve demagnetization faults problems as multiple...

Celý popis

Uložené v:
Podrobná bibliografia
Vydané v:Journal of advanced computational intelligence and intelligent informatics Ročník 20; číslo 7; s. 1127 - 1134
Hlavní autori: Zhang, Changfan, Zhang, Miaoying, He, Jing, Shao, Rui, Luo, Lixiang
Médium: Journal Article
Jazyk:English
Japanese
Vydavateľské údaje: 20.12.2016
ISSN:1343-0130, 1883-8014
On-line prístup:Získať plný text
Tagy: Pridať tag
Žiadne tagy, Buďte prvý, kto otaguje tento záznam!
Popis
Shrnutí:To detect demagnetization faults in real time based on an adaptive sliding mode observer, we used a permanent-magnet synchronous motor (PMSM). Demagnetization faults are first modeled for the PMSM using coordinates oriented to the magnetic field. To solve demagnetization faults problems as multiple parameters change, we used adaptive and sliding mode variable structure control and designed an adaptive sliding mode observer. The adaptive estimation algorithm of the permanent magnet flux is given and the observer’s stability is proven by Lyapunov stability theory. Simulation and experimental results demonstrate the feasibility and effectiveness of our proposal.
ISSN:1343-0130
1883-8014
DOI:10.20965/jaciii.2016.p1127