Enhanced Ion Transmission Efficiency up to m/ z 24 000 for MALDI Protein Imaging Mass Spectrometry

The molecular identification of species of interest is an important part of an imaging mass spectrometry (IMS) experiment. The high resolution accurate mass capabilities of Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) have recently been shown to facilitate the identificati...

Celý popis

Uloženo v:
Podrobná bibliografie
Vydáno v:Analytical chemistry (Washington) Ročník 90; číslo 8; s. 5090
Hlavní autoři: Prentice, Boone M, Ryan, Daniel J, Van de Plas, Raf, Caprioli, Richard M, Spraggins, Jeffrey M
Médium: Journal Article
Jazyk:angličtina
Vydáno: United States 17.04.2018
Témata:
ISSN:1520-6882, 1520-6882
On-line přístup:Zjistit podrobnosti o přístupu
Tagy: Přidat tag
Žádné tagy, Buďte první, kdo vytvoří štítek k tomuto záznamu!
Abstract The molecular identification of species of interest is an important part of an imaging mass spectrometry (IMS) experiment. The high resolution accurate mass capabilities of Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) have recently been shown to facilitate the identification of proteins in matrix-assisted laser desorption/ionization (MALDI) IMS. However, these experiments are typically limited to proteins giving rise to ions of relatively low m/ z due to difficulties transmitting and measuring large molecular weight ions of low charge states. Herein we have modified the source gas manifold of a commercial MALDI FT-ICR MS to regulate the gas flow and pressure to maximize the transmission of large m/ z protein ions through the ion funnel region of the instrument. By minimizing the contribution of off-axis gas disruption to ion focusing and maximizing the effective potential wall confining the ions through pressure optimization, the signal-to-noise ratios (S/N) of most protein species were improved by roughly 1 order of magnitude compared to normal source conditions. These modifications enabled the detection of protein standards up to m/ z 24 000 and the detection of proteins from tissue up to m/ z 22 000 with good S/N, roughly doubling the mass range for which high quality protein ion images from rat brain and kidney tissue could be produced. Due to the long time-domain transients (>4 s) required to isotopically resolve high m/ z proteins, we have used these data as part of an FT-ICR IMS-microscopy data-driven image fusion workflow to produce estimated protein images with both high mass and high spatial resolutions.
AbstractList The molecular identification of species of interest is an important part of an imaging mass spectrometry (IMS) experiment. The high resolution accurate mass capabilities of Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) have recently been shown to facilitate the identification of proteins in matrix-assisted laser desorption/ionization (MALDI) IMS. However, these experiments are typically limited to proteins giving rise to ions of relatively low m/ z due to difficulties transmitting and measuring large molecular weight ions of low charge states. Herein we have modified the source gas manifold of a commercial MALDI FT-ICR MS to regulate the gas flow and pressure to maximize the transmission of large m/ z protein ions through the ion funnel region of the instrument. By minimizing the contribution of off-axis gas disruption to ion focusing and maximizing the effective potential wall confining the ions through pressure optimization, the signal-to-noise ratios (S/N) of most protein species were improved by roughly 1 order of magnitude compared to normal source conditions. These modifications enabled the detection of protein standards up to m/ z 24 000 and the detection of proteins from tissue up to m/ z 22 000 with good S/N, roughly doubling the mass range for which high quality protein ion images from rat brain and kidney tissue could be produced. Due to the long time-domain transients (>4 s) required to isotopically resolve high m/ z proteins, we have used these data as part of an FT-ICR IMS-microscopy data-driven image fusion workflow to produce estimated protein images with both high mass and high spatial resolutions.
The molecular identification of species of interest is an important part of an imaging mass spectrometry (IMS) experiment. The high resolution accurate mass capabilities of Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) have recently been shown to facilitate the identification of proteins in matrix-assisted laser desorption/ionization (MALDI) IMS. However, these experiments are typically limited to proteins giving rise to ions of relatively low m/ z due to difficulties transmitting and measuring large molecular weight ions of low charge states. Herein we have modified the source gas manifold of a commercial MALDI FT-ICR MS to regulate the gas flow and pressure to maximize the transmission of large m/ z protein ions through the ion funnel region of the instrument. By minimizing the contribution of off-axis gas disruption to ion focusing and maximizing the effective potential wall confining the ions through pressure optimization, the signal-to-noise ratios (S/N) of most protein species were improved by roughly 1 order of magnitude compared to normal source conditions. These modifications enabled the detection of protein standards up to m/ z 24 000 and the detection of proteins from tissue up to m/ z 22 000 with good S/N, roughly doubling the mass range for which high quality protein ion images from rat brain and kidney tissue could be produced. Due to the long time-domain transients (>4 s) required to isotopically resolve high m/ z proteins, we have used these data as part of an FT-ICR IMS-microscopy data-driven image fusion workflow to produce estimated protein images with both high mass and high spatial resolutions.The molecular identification of species of interest is an important part of an imaging mass spectrometry (IMS) experiment. The high resolution accurate mass capabilities of Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) have recently been shown to facilitate the identification of proteins in matrix-assisted laser desorption/ionization (MALDI) IMS. However, these experiments are typically limited to proteins giving rise to ions of relatively low m/ z due to difficulties transmitting and measuring large molecular weight ions of low charge states. Herein we have modified the source gas manifold of a commercial MALDI FT-ICR MS to regulate the gas flow and pressure to maximize the transmission of large m/ z protein ions through the ion funnel region of the instrument. By minimizing the contribution of off-axis gas disruption to ion focusing and maximizing the effective potential wall confining the ions through pressure optimization, the signal-to-noise ratios (S/N) of most protein species were improved by roughly 1 order of magnitude compared to normal source conditions. These modifications enabled the detection of protein standards up to m/ z 24 000 and the detection of proteins from tissue up to m/ z 22 000 with good S/N, roughly doubling the mass range for which high quality protein ion images from rat brain and kidney tissue could be produced. Due to the long time-domain transients (>4 s) required to isotopically resolve high m/ z proteins, we have used these data as part of an FT-ICR IMS-microscopy data-driven image fusion workflow to produce estimated protein images with both high mass and high spatial resolutions.
Author Ryan, Daniel J
Prentice, Boone M
Caprioli, Richard M
Van de Plas, Raf
Spraggins, Jeffrey M
Author_xml – sequence: 1
  givenname: Boone M
  orcidid: 0000-0002-1927-9457
  surname: Prentice
  fullname: Prentice, Boone M
– sequence: 2
  givenname: Daniel J
  orcidid: 0000-0001-8201-1472
  surname: Ryan
  fullname: Ryan, Daniel J
– sequence: 3
  givenname: Raf
  orcidid: 0000-0002-2232-7130
  surname: Van de Plas
  fullname: Van de Plas, Raf
  organization: Delft Center for Systems and Control , Delft University of Technology , Delft 2628 CD , The Netherlands
– sequence: 4
  givenname: Richard M
  orcidid: 0000-0001-5859-3310
  surname: Caprioli
  fullname: Caprioli, Richard M
– sequence: 5
  givenname: Jeffrey M
  orcidid: 0000-0001-9198-5498
  surname: Spraggins
  fullname: Spraggins, Jeffrey M
BackLink https://www.ncbi.nlm.nih.gov/pubmed/29444410$$D View this record in MEDLINE/PubMed
BookMark eNpNUM1OwzAYi9AQ-4E3QChHLt2-pGnaHqcxoNImkBjnKknTrahNStIexok34p14EooACV9sS5Yle4pGxhqN0CWBOQFKFkL5uTCiVgfdzGMJEYHoBE1IRCHgSUJH__QYTb1_ASAECD9DY5qyAQQmqFibgzBKFzizBu-cML6pvK8Gsy7LSlXaqCPuW9xZ3CzwG6bs8_0DAHBpHd4uNzcZfnS205XBWSP2ldnjrfAeP7Vadc42unPHc3Raitrri1-eoefb9W51H2we7rLVchMIlpIoCJmUjHCQoU5UzDgFoCBAxVHJWRGnLOZSgubAZMK1SIfBURHKMlQJKQsq6Qxd__S2zr722nf5sEXpuhZG297n34UsYYzyIXr1G-1lo4u8dVUj3DH_e4Z-AaAUaIk
CitedBy_id crossref_primary_10_1016_j_exer_2020_108134
crossref_primary_10_1002_anie_202200721
crossref_primary_10_1002_cne_24571
crossref_primary_10_1016_j_aca_2025_343998
crossref_primary_10_1016_j_trac_2023_117095
crossref_primary_10_1002_mas_21725
crossref_primary_10_1021_jasms_1c00213
crossref_primary_10_1016_j_chembiol_2022_05_004
crossref_primary_10_1186_s12014_025_09531_x
crossref_primary_10_1016_j_cbpa_2018_10_023
crossref_primary_10_1002_mas_21661
crossref_primary_10_1021_acs_analchem_5c00157
crossref_primary_10_1016_j_molliq_2019_111307
crossref_primary_10_1016_j_trac_2023_117257
crossref_primary_10_1002_rcm_8703
crossref_primary_10_1007_s11101_023_09898_5
crossref_primary_10_1016_j_aca_2021_339084
crossref_primary_10_1042_EBC20220191
crossref_primary_10_1016_j_molstruc_2022_132701
crossref_primary_10_1002_ange_202200721
crossref_primary_10_1021_jasms_3c00180
crossref_primary_10_1002_jms_4473
crossref_primary_10_3389_fchem_2022_904688
crossref_primary_10_1016_j_scitotenv_2022_160463
crossref_primary_10_1002_mas_21790
crossref_primary_10_1111_jnc_14559
crossref_primary_10_1146_annurev_anchem_083023_024546
ContentType Journal Article
DBID CGR
CUY
CVF
ECM
EIF
NPM
7X8
DOI 10.1021/acs.analchem.7b05105
DatabaseName Medline
MEDLINE
MEDLINE (Ovid)
MEDLINE
MEDLINE
PubMed
MEDLINE - Academic
DatabaseTitle MEDLINE
Medline Complete
MEDLINE with Full Text
PubMed
MEDLINE (Ovid)
MEDLINE - Academic
DatabaseTitleList MEDLINE
MEDLINE - Academic
Database_xml – sequence: 1
  dbid: NPM
  name: PubMed
  url: http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed
  sourceTypes: Index Database
– sequence: 2
  dbid: 7X8
  name: MEDLINE - Academic
  url: https://search.proquest.com/medline
  sourceTypes: Aggregation Database
DeliveryMethod no_fulltext_linktorsrc
Discipline Engineering
Chemistry
EISSN 1520-6882
ExternalDocumentID 29444410
Genre Journal Article
Research Support, N.I.H., Extramural
GrantInformation_xml – fundername: NIH HHS
  grantid: S10 OD012359
– fundername: NIGMS NIH HHS
  grantid: P41 GM103391
GroupedDBID ---
-DZ
-~X
.DC
.K2
23M
4.4
53G
55A
5GY
5RE
5VS
6J9
7~N
85S
AABXI
AAHBH
ABHFT
ABHMW
ABJNI
ABMVS
ABOCM
ABPPZ
ABQRX
ABUCX
ACBEA
ACGFO
ACGFS
ACGOD
ACIWK
ACJ
ACKOT
ACNCT
ACPRK
ACS
ADHLV
AEESW
AENEX
AFEFF
AFRAH
AGXLV
AHGAQ
ALMA_UNASSIGNED_HOLDINGS
AQSVZ
BAANH
BKOMP
CGR
CS3
CUPRZ
CUY
CVF
D0L
EBS
ECM
ED~
EIF
EJD
F5P
GGK
GNL
IH9
IHE
JG~
KZ1
LMP
NPM
P2P
PQQKQ
ROL
RXW
TAE
TN5
UHB
UI2
UKR
VF5
VG9
W1F
WH7
X6Y
XSW
YZZ
ZCA
~02
7X8
ABBLG
ABLBI
ABUFD
ID FETCH-LOGICAL-a4915-34bb4160b3e8c74620020a0c75f64d79476bb0e604b86ea91055d3bf3c81fd2b2
IEDL.DBID 7X8
ISSN 1520-6882
IngestDate Sun Nov 09 09:12:35 EST 2025
Thu Apr 03 06:57:43 EDT 2025
IsDoiOpenAccess false
IsOpenAccess true
IsPeerReviewed true
IsScholarly true
Issue 8
Language English
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-a4915-34bb4160b3e8c74620020a0c75f64d79476bb0e604b86ea91055d3bf3c81fd2b2
Notes ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ORCID 0000-0001-8201-1472
0000-0002-2232-7130
0000-0002-1927-9457
0000-0001-5859-3310
0000-0001-9198-5498
OpenAccessLink https://www.ncbi.nlm.nih.gov/pmc/articles/6905630
PMID 29444410
PQID 2002484426
PQPubID 23479
ParticipantIDs proquest_miscellaneous_2002484426
pubmed_primary_29444410
PublicationCentury 2000
PublicationDate 2018-04-17
PublicationDateYYYYMMDD 2018-04-17
PublicationDate_xml – month: 04
  year: 2018
  text: 2018-04-17
  day: 17
PublicationDecade 2010
PublicationPlace United States
PublicationPlace_xml – name: United States
PublicationTitle Analytical chemistry (Washington)
PublicationTitleAlternate Anal Chem
PublicationYear 2018
SSID ssj0011016
Score 2.4296925
Snippet The molecular identification of species of interest is an important part of an imaging mass spectrometry (IMS) experiment. The high resolution accurate mass...
SourceID proquest
pubmed
SourceType Aggregation Database
Index Database
StartPage 5090
SubjectTerms Animals
Apoproteins - chemistry
Brain - metabolism
Ions - chemistry
Kidney - metabolism
Molecular Weight
Myoglobin - chemistry
Proteins - chemistry
Rats
Signal-To-Noise Ratio
Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization - methods
Ubiquitin - chemistry
Title Enhanced Ion Transmission Efficiency up to m/ z 24 000 for MALDI Protein Imaging Mass Spectrometry
URI https://www.ncbi.nlm.nih.gov/pubmed/29444410
https://www.proquest.com/docview/2002484426
Volume 90
hasFullText
inHoldings 1
isFullTextHit
isPrint
link http://cvtisr.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwpV07T8MwELaAIgEDj_IqLxmJNa2TOK8JVaUVlWjVAaRukR07okOTQloGJv4R_4lfwp2bqCxISGTIlCixfb77fGd_HyE3rqc0Oj0LiVMszqVnhVIKC4KzFi5YkPKEEZsIhsNwPI5GZcKtKLdVVj7ROGqVJ5gjbzmGfYtDQLmdvVioGoXV1VJCY53UXIAyaNXBeFVFwJWp4UvFJRJAyeronGO3RFI0BQwV9My0GUg0Te93kGmCTW_vv7-5T3ZLmEnbS7s4IGs6q5OtTqXuVic7P4gID4nqZs9mKwDt5xk18QsexEQa7RqOCTygSRczOs_ptEXfqcO_Pj7Bz1HAvHTQfrjr0xEyPkwy2p8a4SM6AFhOUd5-jowI8NEj8tTrPnburVJ_wRI8sj0YPikBrzHp6jAJuI9tY4IlgZf6XMFEDnwpmfYZl6GvRYRam8qVqZuEdqoc6RyTjSzP9CmhHlOh7Qk3kXaE4VACLA0jhynt20masga5rrozhvZh0UJkOl8U8apDG-RkOSbxbEnEETsRh8tmZ394-5xsA9YJsRBkBxeklsLs1pdkM3mbT4rXK2M4cB-OBt_9ysvx
linkProvider ProQuest
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Enhanced+Ion+Transmission+Efficiency+up+to+m%2F+z+24%E2%80%AF000+for+MALDI+Protein+Imaging+Mass+Spectrometry&rft.jtitle=Analytical+chemistry+%28Washington%29&rft.au=Prentice%2C+Boone+M&rft.au=Ryan%2C+Daniel+J&rft.au=Van+de+Plas%2C+Raf&rft.au=Caprioli%2C+Richard+M&rft.date=2018-04-17&rft.eissn=1520-6882&rft.volume=90&rft.issue=8&rft.spage=5090&rft_id=info:doi/10.1021%2Facs.analchem.7b05105&rft_id=info%3Apmid%2F29444410&rft_id=info%3Apmid%2F29444410&rft.externalDocID=29444410
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1520-6882&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1520-6882&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1520-6882&client=summon