Disposable Nitrile Glove Resistance to Limonene: Dextrous Robot Hand Versus ASTM F739 Comparison
The current technique to assess glove resistance to chemicals for worker protection relies on challenging a flat, 2.54 cm diameter glove piece at or near room temperature. This does not simulate a donned whole glove near the skin temperature subjected to work activity forces. Four different types of...
Uloženo v:
| Vydáno v: | ACS Chemical Health & Safety. Ročník 31; číslo 3; s. 253 |
|---|---|
| Hlavní autoři: | , , |
| Médium: | Journal Article |
| Jazyk: | angličtina |
| Vydáno: |
United States
27.05.2024
|
| ISSN: | 1878-0504, 1878-0504 |
| On-line přístup: | Zjistit podrobnosti o přístupu |
| Tagy: |
Přidat tag
Žádné tagy, Buďte první, kdo vytvoří štítek k tomuto záznamu!
|
| Abstract | The current technique to assess glove resistance to chemicals for worker protection relies on challenging a flat, 2.54 cm diameter glove piece at or near room temperature. This does not simulate a donned whole glove near the skin temperature subjected to work activity forces. Four different types of disposable nonpowdered unlined/unsupported nitrile gloves in triplicate were measured for thickness, porosity, and for the acrylonitrile content (
) of the challenge and collection sides. Limonene permeation at 35 °C through a whole glove on a clenching and nonclenching dextrous robot hand and with the standard ASTM F739 technique were facilitated by taking samples from the collection sides for GC-MS analysis. The standardized breakthrough time (SBT) when permeation reached 100 ng/cm
/min and the steady state permeation rate (SSPR) depended on
, thickness, and porosity. Only the thinnest glove (Lavender) showed statistically significant (
≤ 0.05) increased average SSPR for the clenching hand relative to the nonclenching hand and for the ASTM technique. The ASTM test data for the three thickest gloves were not statistically different from those of the robot hand, but differed from the manufacturer's. More research with different chemicals and higher clenching forces is needed. Clenching forces can enhance the permeation. Workers wearing ultrathin disposable nitrile gloves have a higher potential for chemical penetration/permeation. Company glove permeation data obtained near room temperature may have a longer SBT and lower SSPR than in practice. Double gloving may be advisible in emergencies and for unknown chemicals when no appropriate thicker Chemical Protective glove is available. |
|---|---|
| AbstractList | The current technique to assess glove resistance to chemicals for worker protection relies on challenging a flat, 2.54 cm diameter glove piece at or near room temperature. This does not simulate a donned whole glove near the skin temperature subjected to work activity forces. Four different types of disposable nonpowdered unlined/unsupported nitrile gloves in triplicate were measured for thickness, porosity, and for the acrylonitrile content (
) of the challenge and collection sides. Limonene permeation at 35 °C through a whole glove on a clenching and nonclenching dextrous robot hand and with the standard ASTM F739 technique were facilitated by taking samples from the collection sides for GC-MS analysis. The standardized breakthrough time (SBT) when permeation reached 100 ng/cm
/min and the steady state permeation rate (SSPR) depended on
, thickness, and porosity. Only the thinnest glove (Lavender) showed statistically significant (
≤ 0.05) increased average SSPR for the clenching hand relative to the nonclenching hand and for the ASTM technique. The ASTM test data for the three thickest gloves were not statistically different from those of the robot hand, but differed from the manufacturer's. More research with different chemicals and higher clenching forces is needed. Clenching forces can enhance the permeation. Workers wearing ultrathin disposable nitrile gloves have a higher potential for chemical penetration/permeation. Company glove permeation data obtained near room temperature may have a longer SBT and lower SSPR than in practice. Double gloving may be advisible in emergencies and for unknown chemicals when no appropriate thicker Chemical Protective glove is available. The current technique to assess glove resistance to chemicals for worker protection relies on challenging a flat, 2.54 cm diameter glove piece at or near room temperature. This does not simulate a donned whole glove near the skin temperature subjected to work activity forces. Four different types of disposable nonpowdered unlined/unsupported nitrile gloves in triplicate were measured for thickness, porosity, and for the acrylonitrile content (A) of the challenge and collection sides. Limonene permeation at 35 °C through a whole glove on a clenching and nonclenching dextrous robot hand and with the standard ASTM F739 technique were facilitated by taking samples from the collection sides for GC-MS analysis. The standardized breakthrough time (SBT) when permeation reached 100 ng/cm2/min and the steady state permeation rate (SSPR) depended on A, thickness, and porosity. Only the thinnest glove (Lavender) showed statistically significant (p ≤ 0.05) increased average SSPR for the clenching hand relative to the nonclenching hand and for the ASTM technique. The ASTM test data for the three thickest gloves were not statistically different from those of the robot hand, but differed from the manufacturer's. More research with different chemicals and higher clenching forces is needed. Clenching forces can enhance the permeation. Workers wearing ultrathin disposable nitrile gloves have a higher potential for chemical penetration/permeation. Company glove permeation data obtained near room temperature may have a longer SBT and lower SSPR than in practice. Double gloving may be advisible in emergencies and for unknown chemicals when no appropriate thicker Chemical Protective glove is available.The current technique to assess glove resistance to chemicals for worker protection relies on challenging a flat, 2.54 cm diameter glove piece at or near room temperature. This does not simulate a donned whole glove near the skin temperature subjected to work activity forces. Four different types of disposable nonpowdered unlined/unsupported nitrile gloves in triplicate were measured for thickness, porosity, and for the acrylonitrile content (A) of the challenge and collection sides. Limonene permeation at 35 °C through a whole glove on a clenching and nonclenching dextrous robot hand and with the standard ASTM F739 technique were facilitated by taking samples from the collection sides for GC-MS analysis. The standardized breakthrough time (SBT) when permeation reached 100 ng/cm2/min and the steady state permeation rate (SSPR) depended on A, thickness, and porosity. Only the thinnest glove (Lavender) showed statistically significant (p ≤ 0.05) increased average SSPR for the clenching hand relative to the nonclenching hand and for the ASTM technique. The ASTM test data for the three thickest gloves were not statistically different from those of the robot hand, but differed from the manufacturer's. More research with different chemicals and higher clenching forces is needed. Clenching forces can enhance the permeation. Workers wearing ultrathin disposable nitrile gloves have a higher potential for chemical penetration/permeation. Company glove permeation data obtained near room temperature may have a longer SBT and lower SSPR than in practice. Double gloving may be advisible in emergencies and for unknown chemicals when no appropriate thicker Chemical Protective glove is available. |
| Author | Banaee, Sean Mathews, Airek Que Hee, Shane |
| Author_xml | – sequence: 1 givenname: Sean surname: Banaee fullname: Banaee, Sean organization: Department of Environmental Health Sciences and UCLA Center for Occupational & Environmental Health, Fielding School of Public Health, University of California Los Angeles, 650 Charles E Young Jr Drive South, Los Angeles, California 90095-1772, United States – sequence: 2 givenname: Airek surname: Mathews fullname: Mathews, Airek organization: Department of Environmental Health Sciences and UCLA Center for Occupational & Environmental Health, Fielding School of Public Health, University of California Los Angeles, 650 Charles E Young Jr Drive South, Los Angeles, California 90095-1772, United States – sequence: 3 givenname: Shane orcidid: 0000-0001-6885-879X surname: Que Hee fullname: Que Hee, Shane organization: Department of Environmental Health Sciences and UCLA Center for Occupational & Environmental Health, Fielding School of Public Health, University of California Los Angeles, 650 Charles E Young Jr Drive South, Los Angeles, California 90095-1772, United States |
| BackLink | https://www.ncbi.nlm.nih.gov/pubmed/38818310$$D View this record in MEDLINE/PubMed |
| BookMark | eNpNUEtLw0AYXKRia-3dk-zRS-q-s_FW-hSqQq1e42bzBVeSbMymov_egBU8zTAMM8Oco0Hta0DokpIpJYzeGBum9s2EKbeEUBqfoBHVsY6IJGLwjw_RJIR3QgjjlAuZnKEh15pqTskIvS5caHwwWQn4wXWt63Fd-k_AOwgudKa2gDuPt67q22u4xQv46lp_CHjnM9_hjalz_AJt6JXZ0_4er2Ke4LmvGtO64OsLdFqYMsDkiGP0vFru55to-7i-m8-2kRFcdJFkQBlRhVFMEw2FpCqRHIArK2UGeWJpxpQWgpksL1QMmcxNYaEADnlsBBuj69_cpvUfBwhdWrlgoSxNDf3alBPFhSKU0N56dbQesgrytGldZdrv9O8V9gNIL2fC |
| CitedBy_id | crossref_primary_10_1021_acs_chas_5c00032 crossref_primary_10_1080_15459624_2025_2537391 |
| ContentType | Journal Article |
| Copyright | 2024 The Authors. Published by American Chemical Society. |
| Copyright_xml | – notice: 2024 The Authors. Published by American Chemical Society. |
| DBID | NPM 7X8 |
| DOI | 10.1021/acs.chas.3c00117 |
| DatabaseName | PubMed MEDLINE - Academic |
| DatabaseTitle | PubMed MEDLINE - Academic |
| DatabaseTitleList | PubMed MEDLINE - Academic |
| Database_xml | – sequence: 1 dbid: NPM name: PubMed url: http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed sourceTypes: Index Database – sequence: 2 dbid: 7X8 name: MEDLINE - Academic url: https://search.proquest.com/medline sourceTypes: Aggregation Database |
| DeliveryMethod | no_fulltext_linktorsrc |
| Discipline | Medicine |
| EISSN | 1878-0504 |
| ExternalDocumentID | 38818310 |
| Genre | Journal Article |
| GrantInformation_xml | – fundername: NIOSH CDC HHS grantid: T42 OH008412 |
| GroupedDBID | --K --M .~1 0R~ 1B1 1~. 1~5 4.4 457 4G. 53G 7-5 71M 8P~ AACTN AAEDT AAIKJ AAKOC AALRI AAOAW AARLI ABJNI ABNUV ABQRX ACDAQ ACGFS ACS ADBBV ADECG ADEWK ADEZE AEKER AFTJW AGHFR AGUBO AGYEJ AHGAQ ALMA_UNASSIGNED_HOLDINGS BAANH BLXMC CS3 CUPRZ DU5 EBS ENUVR EO8 EO9 EP2 EP3 FDB FEDTE FLBIZ FNPLU G-Q GBLVA GGK HVGLF IHE J1W MO0 N9A NPM O-L O9- OAUVE OZT P-8 P-9 P2P PC. Q38 RPZ SDF SES SEW SSZ VF5 VG9 ~G- 7X8 ABBLG ABLBI ~HD |
| ID | FETCH-LOGICAL-a434t-52e1206fa62808ef516953ee36c55bed9c1b268442abdf67eb5dafcefe3ed7a42 |
| IEDL.DBID | 7X8 |
| ISICitedReferencesCount | 2 |
| ISICitedReferencesURI | http://www.webofscience.com/api/gateway?GWVersion=2&SrcApp=Summon&SrcAuth=ProQuest&DestLinkType=CitingArticles&DestApp=WOS_CPL&KeyUT=001189143700001&url=https%3A%2F%2Fcvtisr.summon.serialssolutions.com%2F%23%21%2Fsearch%3Fho%3Df%26include.ft.matches%3Dt%26l%3Dnull%26q%3D |
| ISSN | 1878-0504 |
| IngestDate | Mon Sep 29 03:50:48 EDT 2025 Thu Apr 03 07:01:07 EDT 2025 |
| IsDoiOpenAccess | false |
| IsOpenAccess | true |
| IsPeerReviewed | true |
| IsScholarly | true |
| Issue | 3 |
| Language | English |
| License | 2024 The Authors. Published by American Chemical Society. |
| LinkModel | DirectLink |
| MergedId | FETCHMERGED-LOGICAL-a434t-52e1206fa62808ef516953ee36c55bed9c1b268442abdf67eb5dafcefe3ed7a42 |
| Notes | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
| ORCID | 0000-0001-6885-879X |
| OpenAccessLink | https://pubmed.ncbi.nlm.nih.gov/PMC11134495 |
| PMID | 38818310 |
| PQID | 3063460101 |
| PQPubID | 23479 |
| ParticipantIDs | proquest_miscellaneous_3063460101 pubmed_primary_38818310 |
| PublicationCentury | 2000 |
| PublicationDate | 2024-05-27 |
| PublicationDateYYYYMMDD | 2024-05-27 |
| PublicationDate_xml | – month: 05 year: 2024 text: 2024-05-27 day: 27 |
| PublicationDecade | 2020 |
| PublicationPlace | United States |
| PublicationPlace_xml | – name: United States |
| PublicationTitle | ACS Chemical Health & Safety. |
| PublicationTitleAlternate | J Chem Health Saf |
| PublicationYear | 2024 |
| SSID | ssj0002313459 |
| Score | 2.30859 |
| Snippet | The current technique to assess glove resistance to chemicals for worker protection relies on challenging a flat, 2.54 cm diameter glove piece at or near room... |
| SourceID | proquest pubmed |
| SourceType | Aggregation Database Index Database |
| StartPage | 253 |
| Title | Disposable Nitrile Glove Resistance to Limonene: Dextrous Robot Hand Versus ASTM F739 Comparison |
| URI | https://www.ncbi.nlm.nih.gov/pubmed/38818310 https://www.proquest.com/docview/3063460101 |
| Volume | 31 |
| WOSCitedRecordID | wos001189143700001&url=https%3A%2F%2Fcvtisr.summon.serialssolutions.com%2F%23%21%2Fsearch%3Fho%3Df%26include.ft.matches%3Dt%26l%3Dnull%26q%3D |
| hasFullText | |
| inHoldings | 1 |
| isFullTextHit | |
| isPrint | |
| link | http://cvtisr.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwpV1LT8MwDI6AIcSF92O8FCSuZW2TtikXNG1MO7BqGkPabaSJI3Zpx1r4_ThdN05ISFx6qNQqjV37sz_HJuROuqEyhkeOQu_noL81jgCtHFAgYqVSrn1VDZuIkkRMJvGwTrgVdVnlyiZWhlrnyubIWwhtGbfRg_c4_3Ds1CjLrtYjNDZJgyGUsVodTcQ6x4LYhfFqXponbCPZwOU1U4merSUVSvVdFvdMVZ3RfseYla_p7f93lQdkr0aZtL1Ui0OyAdkR2RnUPPoxeevObLmWPTZFk1m5QNNAq2pOOoLCIkpUBVrm9BklmaE1fKBdNOKL_LOgozzNS9qXmaY214Z32i_jAe1FLKad9VDDE_Laexp3-k49a8GRnPES41HwfDc0MvSFK8BY-ixgACxUQZCCjpWX2sYw3JepNmEEaaClUWCAgY4k90_JVoYrOic0xTfgBqQuhipcMyOjkOuYBQa4ER6DJrld7d0UddkSFDID_ILpz-41ydlSANP5sunGlAmEFohFL_7w9CXZ9RF7WJLfj65Iw-CfDNdkW32Vs2JxUykJXpPh4BuVVsdN |
| linkProvider | ProQuest |
| openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Disposable+Nitrile+Glove+Resistance+to+Limonene%3A+Dextrous+Robot+Hand+Versus+ASTM+F739+Comparison&rft.jtitle=ACS+Chemical+Health+%26+Safety.&rft.au=Banaee%2C+Sean&rft.au=Mathews%2C+Airek&rft.au=Que+Hee%2C+Shane&rft.date=2024-05-27&rft.issn=1878-0504&rft.eissn=1878-0504&rft.volume=31&rft.issue=3&rft.spage=253&rft_id=info:doi/10.1021%2Facs.chas.3c00117&rft.externalDBID=NO_FULL_TEXT |
| thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1878-0504&client=summon |
| thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1878-0504&client=summon |
| thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1878-0504&client=summon |