Investigation of the Different Regimes Associated with the Growth of an Interface at the Exit of a Capillary Tube into a Reservoir: Analytical Solutions and CFD Validation

The emergence of a droplet from a capillary tube opening into a reservoir is an important phenomenon in several applications. In this work, we are particularly interested in this phenomenon in an attempt to highlight the physics behind droplet appearance. The emergence of a droplet from a tube openi...

Celý popis

Uloženo v:
Podrobná bibliografie
Vydáno v:Langmuir Ročník 38; číslo 33; s. 10274
Hlavní autoři: Salama, Amgad, Van Geel, Paul J, Kou, Jisheng, Husein, Maen M
Médium: Journal Article
Jazyk:angličtina
Vydáno: 23.08.2022
ISSN:1520-5827, 1520-5827
On-line přístup:Zjistit podrobnosti o přístupu
Tagy: Přidat tag
Žádné tagy, Buďte první, kdo vytvoří štítek k tomuto záznamu!
Abstract The emergence of a droplet from a capillary tube opening into a reservoir is an important phenomenon in several applications. In this work, we are particularly interested in this phenomenon in an attempt to highlight the physics behind droplet appearance. The emergence of a droplet from a tube opening into a reservoir under quasi-static conditions passes through three stages. The first stage starts when the meniscus in the tube reaches the exit. At this moment, the meniscus intersects the wall of the tube at the equilibrium contact angle. The interface then develops until its radius of curvature becomes equal to the tube radius. During this stage, the capillary pressure increases. In the second stage, the interface continues to evolve with its radius of curvature increasing until the static contact angle with respect to the surface of the reservoir is achieved. This marks the end of the second stage and the start of the third in which the contact line (CL) starts to depart the tube opening along the reservoir surface and the contact angle remains constant. Analytical models for the three stages have been derived based on the law of conservation of linear momentum. The models account for pressure, gravitational, capillary, and viscous forces, while inertia force is ignored. The model can predict the profiles of the mean velocity in the tube, the capillary pressure, and the evolution of the contact angle. In addition, a computational fluid dynamics (CFD) simulation has been conducted to provide a framework for validation and verification of the developed model. The CFD simulation shows qualitative behavior in terms of snapshots of the emerging droplet with time similar to that speculated by the analytical model. In addition, quantitative comparisons with respect to velocity, pressure, and volume profiles of the droplet show very good agreement, which builds confidence in the modeling approach.The emergence of a droplet from a capillary tube opening into a reservoir is an important phenomenon in several applications. In this work, we are particularly interested in this phenomenon in an attempt to highlight the physics behind droplet appearance. The emergence of a droplet from a tube opening into a reservoir under quasi-static conditions passes through three stages. The first stage starts when the meniscus in the tube reaches the exit. At this moment, the meniscus intersects the wall of the tube at the equilibrium contact angle. The interface then develops until its radius of curvature becomes equal to the tube radius. During this stage, the capillary pressure increases. In the second stage, the interface continues to evolve with its radius of curvature increasing until the static contact angle with respect to the surface of the reservoir is achieved. This marks the end of the second stage and the start of the third in which the contact line (CL) starts to depart the tube opening along the reservoir surface and the contact angle remains constant. Analytical models for the three stages have been derived based on the law of conservation of linear momentum. The models account for pressure, gravitational, capillary, and viscous forces, while inertia force is ignored. The model can predict the profiles of the mean velocity in the tube, the capillary pressure, and the evolution of the contact angle. In addition, a computational fluid dynamics (CFD) simulation has been conducted to provide a framework for validation and verification of the developed model. The CFD simulation shows qualitative behavior in terms of snapshots of the emerging droplet with time similar to that speculated by the analytical model. In addition, quantitative comparisons with respect to velocity, pressure, and volume profiles of the droplet show very good agreement, which builds confidence in the modeling approach.
AbstractList The emergence of a droplet from a capillary tube opening into a reservoir is an important phenomenon in several applications. In this work, we are particularly interested in this phenomenon in an attempt to highlight the physics behind droplet appearance. The emergence of a droplet from a tube opening into a reservoir under quasi-static conditions passes through three stages. The first stage starts when the meniscus in the tube reaches the exit. At this moment, the meniscus intersects the wall of the tube at the equilibrium contact angle. The interface then develops until its radius of curvature becomes equal to the tube radius. During this stage, the capillary pressure increases. In the second stage, the interface continues to evolve with its radius of curvature increasing until the static contact angle with respect to the surface of the reservoir is achieved. This marks the end of the second stage and the start of the third in which the contact line (CL) starts to depart the tube opening along the reservoir surface and the contact angle remains constant. Analytical models for the three stages have been derived based on the law of conservation of linear momentum. The models account for pressure, gravitational, capillary, and viscous forces, while inertia force is ignored. The model can predict the profiles of the mean velocity in the tube, the capillary pressure, and the evolution of the contact angle. In addition, a computational fluid dynamics (CFD) simulation has been conducted to provide a framework for validation and verification of the developed model. The CFD simulation shows qualitative behavior in terms of snapshots of the emerging droplet with time similar to that speculated by the analytical model. In addition, quantitative comparisons with respect to velocity, pressure, and volume profiles of the droplet show very good agreement, which builds confidence in the modeling approach.The emergence of a droplet from a capillary tube opening into a reservoir is an important phenomenon in several applications. In this work, we are particularly interested in this phenomenon in an attempt to highlight the physics behind droplet appearance. The emergence of a droplet from a tube opening into a reservoir under quasi-static conditions passes through three stages. The first stage starts when the meniscus in the tube reaches the exit. At this moment, the meniscus intersects the wall of the tube at the equilibrium contact angle. The interface then develops until its radius of curvature becomes equal to the tube radius. During this stage, the capillary pressure increases. In the second stage, the interface continues to evolve with its radius of curvature increasing until the static contact angle with respect to the surface of the reservoir is achieved. This marks the end of the second stage and the start of the third in which the contact line (CL) starts to depart the tube opening along the reservoir surface and the contact angle remains constant. Analytical models for the three stages have been derived based on the law of conservation of linear momentum. The models account for pressure, gravitational, capillary, and viscous forces, while inertia force is ignored. The model can predict the profiles of the mean velocity in the tube, the capillary pressure, and the evolution of the contact angle. In addition, a computational fluid dynamics (CFD) simulation has been conducted to provide a framework for validation and verification of the developed model. The CFD simulation shows qualitative behavior in terms of snapshots of the emerging droplet with time similar to that speculated by the analytical model. In addition, quantitative comparisons with respect to velocity, pressure, and volume profiles of the droplet show very good agreement, which builds confidence in the modeling approach.
Author Salama, Amgad
Kou, Jisheng
Husein, Maen M
Van Geel, Paul J
Author_xml – sequence: 1
  givenname: Amgad
  surname: Salama
  fullname: Salama, Amgad
– sequence: 2
  givenname: Paul J
  surname: Van Geel
  fullname: Van Geel, Paul J
– sequence: 3
  givenname: Jisheng
  surname: Kou
  fullname: Kou, Jisheng
– sequence: 4
  givenname: Maen M
  surname: Husein
  fullname: Husein, Maen M
BookMark eNpNUE1PAjEUbAwmAvoPPPToZbEt7G7xRviShMQE0St5tG-hZmmx7Yr8Jv-k6-rB05vMvDeZeR3Sss4iIbec9TgT_B5U6JVgd4fK-J5QjGeCXZA2TwVLUiny1j98RTohvDHGhv3BsE2-FvYDQzQ7iMZZ6goa90gnpijQo410hTtzwEBHIThlIKKmJxP3zdbcu1MN6xuwdGEj-gIUUoiNOv00sdHoGI6mLMGf6braIjU2uppdYUD_4Yx_oCML5TkaBSV9dmX1kyTUnpqOZxP6CqXRTbprcllAGfDmb3bJy2y6Hj8my6f5YjxaJiCkjAmkOQwyuZV6y3KupJBDBOC5kLkSQ1SYSZ2lPC8yrbQoBjlAX0utcMtlWrOiS-5-fY_evVf1dzYHExTWFSy6KmxEzlg26AvZF9_nq3jw
CitedBy_id crossref_primary_10_1016_j_ijthermalsci_2023_108622
crossref_primary_10_1007_s11242_024_02114_8
crossref_primary_10_1016_j_ijmultiphaseflow_2024_105010
crossref_primary_10_1016_j_colsurfa_2023_131151
crossref_primary_10_1007_s11012_025_01978_4
ContentType Journal Article
DBID 7X8
DOI 10.1021/acs.langmuir.2c01620
DatabaseName MEDLINE - Academic
DatabaseTitle MEDLINE - Academic
DatabaseTitleList MEDLINE - Academic
Database_xml – sequence: 1
  dbid: 7X8
  name: MEDLINE - Academic
  url: https://search.proquest.com/medline
  sourceTypes: Aggregation Database
DeliveryMethod no_fulltext_linktorsrc
Discipline Chemistry
EISSN 1520-5827
GroupedDBID ---
-~X
.K2
4.4
53G
55A
5GY
5VS
7X8
7~N
AABXI
AAHBH
ABBLG
ABJNI
ABLBI
ABMVS
ABQRX
ABUCX
ACGFS
ACJ
ACNCT
ACS
ADHLV
AEESW
AENEX
AFEFF
AGXLV
AHGAQ
ALMA_UNASSIGNED_HOLDINGS
AQSVZ
BAANH
CS3
CUPRZ
DU5
EBS
ED~
F5P
GGK
GNL
IH9
IHE
JG~
RNS
ROL
TN5
UI2
UPT
VF5
VG9
W1F
YQT
~02
ID FETCH-LOGICAL-a288t-a57a468b8db071c8289eaa17287c29ece68d6517f6dcd2f47aa3d8dceb1857f62
IEDL.DBID 7X8
ISICitedReferencesCount 6
ISICitedReferencesURI http://www.webofscience.com/api/gateway?GWVersion=2&SrcApp=Summon&SrcAuth=ProQuest&DestLinkType=CitingArticles&DestApp=WOS_CPL&KeyUT=000846757900001&url=https%3A%2F%2Fcvtisr.summon.serialssolutions.com%2F%23%21%2Fsearch%3Fho%3Df%26include.ft.matches%3Dt%26l%3Dnull%26q%3D
ISSN 1520-5827
IngestDate Fri Jul 11 08:19:16 EDT 2025
IsPeerReviewed true
IsScholarly true
Issue 33
Language English
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-a288t-a57a468b8db071c8289eaa17287c29ece68d6517f6dcd2f47aa3d8dceb1857f62
Notes ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
PQID 2700643283
PQPubID 23479
ParticipantIDs proquest_miscellaneous_2700643283
PublicationCentury 2000
PublicationDate 2022-08-23
PublicationDateYYYYMMDD 2022-08-23
PublicationDate_xml – month: 08
  year: 2022
  text: 2022-08-23
  day: 23
PublicationDecade 2020
PublicationTitle Langmuir
PublicationYear 2022
SSID ssj0009349
Score 2.4342499
Snippet The emergence of a droplet from a capillary tube opening into a reservoir is an important phenomenon in several applications. In this work, we are particularly...
SourceID proquest
SourceType Aggregation Database
StartPage 10274
Title Investigation of the Different Regimes Associated with the Growth of an Interface at the Exit of a Capillary Tube into a Reservoir: Analytical Solutions and CFD Validation
URI https://www.proquest.com/docview/2700643283
Volume 38
WOSCitedRecordID wos000846757900001&url=https%3A%2F%2Fcvtisr.summon.serialssolutions.com%2F%23%21%2Fsearch%3Fho%3Df%26include.ft.matches%3Dt%26l%3Dnull%26q%3D
hasFullText
inHoldings 1
isFullTextHit
isPrint
link http://cvtisr.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwpV1LS8QwEA6-QC--xTcjeK3WpG1SLyKrq6dFRGVvMpuk0oPt2u2K_ib_pJNsq4IXwVvJo5QknfnmSzIfY4cJQXolhA1CmVKAEhkZDAgnB4pnUSSkIpCMXmxC9nqq309vGsJt1ByrbG2iN9Sm1I4jP3YbpOQ9yRueDV8CpxrldlcbCY1pNisIyrgjXbL_nS08FR7-kosKg1hx2V6d4yfHqEdHjhF8HufVEdcEfHj4yxx7H9Nd-u_XLbPFBl3C-WQ5rLApW6yy-U4r6rbGPn7k1SgLKDMgAAgXjUpKDbf2yd0JgXbWrAHH1PpWVxSx0yP1wQI8k5ihtoC1r718y2tfBx0cOimj6h3uxgMLeVGXVOqO-FWvZV6dgk-E4jl0-GLl6J0GOt0LeKDAYKLztM7uu5d3neug0WsIkCtVBxhLjBI1UGZAwEW7WM4iOgEsqXlqtU2USeITmSVGG1oLElEYZTS5CxVTKd9gM0VZ2E0GIpYpmpA6h1EkkxhDkclUx4oQEhLi22IH7Tw80gi6TQ4sbDkePX7PxPYf2uywBe7uM4RkLsQum83on7d7bE6_1vmo2vfL6RP4wNZA
linkProvider ProQuest
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Investigation+of+the+Different+Regimes+Associated+with+the+Growth+of+an+Interface+at+the+Exit+of+a+Capillary+Tube+into+a+Reservoir%3A+Analytical+Solutions+and+CFD+Validation&rft.jtitle=Langmuir&rft.au=Salama%2C+Amgad&rft.au=Van+Geel%2C+Paul+J&rft.au=Kou%2C+Jisheng&rft.au=Husein%2C+Maen+M&rft.date=2022-08-23&rft.issn=1520-5827&rft.eissn=1520-5827&rft.volume=38&rft.issue=33&rft.spage=10274&rft_id=info:doi/10.1021%2Facs.langmuir.2c01620&rft.externalDBID=NO_FULL_TEXT
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1520-5827&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1520-5827&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1520-5827&client=summon