Výsledky vyhledávání - multi‐slice helical interpolation algorithms
-
1
Multi-slice helical CT: Scan and reconstruction
ISSN: 0094-2405, 2473-4209Vydáno: United States American Association of Physicists in Medicine 01.01.1999Vydáno v Medical physics (Lancaster) (01.01.1999)“… It also presents new challenges and new characteristics. In this paper, we study the scan and reconstruction principles of the multi-slice helical CT in general and the 4-slice helical CT in particular…”
Získat plný text
Journal Article -
2
Algorithm for image reconstruction in multi-slice helical CT
ISSN: 0094-2405, 2473-4209Vydáno: United States American Association of Physicists in Medicine 01.04.1998Vydáno v Medical physics (Lancaster) (01.04.1998)“… Two helical interpolation methods for single-slice CT, 360LI and 180LI, were used as starting points and extended to multi-slice CT…”
Získat plný text
Journal Article -
3
Analytical models for multi-slice helical CT performance parameters
ISSN: 0094-2405, 2473-4209Vydáno: United States American Association of Physicists in Medicine 01.02.2003Vydáno v Medical physics (Lancaster) (01.02.2003)“…) and noise performance. In this paper, we derive several closed-form expressions, for linear interpolation based helical reconstruction algorithms, to characterize these performance parameters under different detector…”
Získat plný text
Journal Article -
4
WE‐A‐301‐11: Low Dose Multi‐Slice Helical CT Reconstruction Using Tight Frame Regularization
ISSN: 0094-2405, 2473-4209Vydáno: American Association of Physicists in Medicine 01.06.2011Vydáno v Medical Physics (01.06.2011)“…Purpose: Multi‐slice helical CT has been widely used in CT diagnostic imaging due to its large coverage and short acquisition time…”
Získat plný text
Konferenční příspěvek Journal Article -
5
Metal artifact reduction from reformatted projections for hip prostheses in multislice helical computed tomography: techniques and initial clinical results
ISSN: 1536-0210, 1536-0210Vydáno: United States 01.11.2009Vydáno v Investigative radiology (01.11.2009)“… The purpose of this work was to develop a projection-based method for reducing metal artifacts caused by hip prostheses in multislice helical CT…”
Zjistit podrobnosti o přístupu
Journal Article -
6
WE‐D‐332‐07: Automatic Metal Artifact Reduction From Reformatted Projections in Multi‐Slice Helical CT
ISSN: 0094-2405, 2473-4209Vydáno: American Association of Physicists in Medicine 01.06.2008Vydáno v Medical Physics (01.06.2008)“…‐slice helical CT and to evaluate it using clinical data. Method and Materials: The proposed method uses reformatted projections created from helical projection data by combining data at the same angle view over the full longitudinal scan range…”
Získat plný text
Konferenční příspěvek Journal Article -
7
ECG-correlated image reconstruction from subsecond multi-slice spiral CT scans of the heart
ISSN: 0094-2405, 2473-4209Vydáno: United States American Association of Physicists in Medicine 01.08.2000Vydáno v Medical physics (Lancaster) (01.08.2000)“… for imaging the heart with subsecond multi-slice spiral CT utilizing electrocardiogram (ECG) information. The single-slice cardiac z-interpolation algorithms 180…”
Získat plný text
Journal Article -
8
Improvement of efficiency and flexibility in multi-slice helical CT
ISSN: 1007-1172, 1995-8188Vydáno: Heidelberg Shanghai Jiaotong University Press 01.08.2008Vydáno v Shanghai jiao tong da xue xue bao (01.08.2008)“… The combination of helical scanning with multi-slice CT is a promising approach. Image reconstruction in multi-slice CT becomes, therefore, the major challenge…”
Získat plný text
Journal Article -
9
The cause of the artifact in 4-slice helical computed tomography
ISSN: 0094-2405, 2473-4209Vydáno: United States American Association of Physicists in Medicine 01.07.2004Vydáno v Medical physics (Lancaster) (01.07.2004)“…) changeover in pairs of data used in z interpolation, (2) sampling interval in z, and (3) the cone angle. This study analyzes the first two causes of the artifact and describes how the current algorithm…”
Získat plný text
Journal Article -
10
Reproducibility of multi-slice spiral computed tomography scans:An experimental study
ISSN: 0094-2405, 2473-4209Vydáno: United States American Association of Physicists in Medicine 01.10.2004Vydáno v Medical physics (Lancaster) (01.10.2004)“…In multi-slice spiral computed tomography (CT) images interpolation artifacts are present…”
Získat plný text
Journal Article -
11
Multi-slice helical CT: principles, imaging characteristics, and performance
ISBN: 0780351649, 9780780351646ISSN: 1094-687X“… A 4-slice CT scanner has been developed. Here, the authors outline the principles of multi-slice helical CT in general and 4-slice helical CT in particular…”Vydáno: IEEE 1998
Získat plný text
Konferenční příspěvek -
12
FFT-based approach to longitudinal interpolation in single- and multi-slice helical CT
ISBN: 9780780356962, 0780356969ISSN: 1082-3654Vydáno: IEEE 1999Vydáno v 1999 IEEE Nuclear Science Symposium. Conference Record. 1999 Nuclear Science Symposium and Medical Imaging Conference (Cat. No.99CH37019) (1999)“…Presents an approach to single- and multi-slice helical computed tomography (CT) image reconstruction that exploits the fast Fourier transform (FFT…”
Získat plný text
Konferenční příspěvek -
13
A nonlinear helical reconstruction algorithm for multi-slice CT
ISBN: 9780780365032, 0780365038ISSN: 1082-3654“… In this paper, we propose a new helical reconstruction algorithm for multi-slice helical CT. To avoid discontinuity in the helical weighting function, a double cone shaped region is selected as the POR…”Vydáno: IEEE 2000
Získat plný text
Konferenční příspěvek -
14
A multi-slice helical CT reconstruction with generalized weighting
ISBN: 9780780373242, 0780373243ISSN: 1082-3654“…Multi-slice computed tomography (MCT) is one of the most recent technology advancements in CT…”Vydáno: IEEE 2001
Získat plný text
Konferenční příspěvek -
15
Reconstruction Algorithm with Improved Efficiency and Flexibility in Multi-Slice Spiral CT
ISBN: 0780387414, 9780780387416ISSN: 1094-687X, 1557-170X“… The combination of spiral scanning with multi-slice CT is a promising approach. The algorithm of image reconstruction for multi-slice spiral CT becomes, therefore, the main challenge…”Vydáno: United States IEEE 2005
Získat plný text
Konferenční příspěvek Journal Article -
16
A detector response adaptive helical reconstruction algorithm
ISBN: 9780780365032, 0780365038ISSN: 1082-3654“…With the recent introduction of multi-slice CT (MCT) by many CT manufactures, research on the subject of multi-slice helical reconstruction has gained significant interests…”Vydáno: IEEE 2000
Získat plný text
Konferenční příspěvek -
17
Feldkamp-type image reconstruction from equiangular data
ISSN: 0895-3996Vydáno: Netherlands 2001Vydáno v Journal of X-ray science and technology (2001)“… Previously, the traditional practical cone-beam reconstruction method, the Feldkamp algorithm, was generalized into the case of spiral/helical scanning loci with equispatial cone-beam projection data…”
Zjistit podrobnosti o přístupu
Journal Article -
18
O(N/sup 2/ log N) native fan-beam tomographic reconstruction
ISBN: 078037584X, 9780780375840Vydáno: IEEE 2002Vydáno v 2002 IEEE International Symposium on Biomedical Imaging : proceedings : July 7-10, 2002, Ritz-Carlton Hotel, Washington, D.C., USA (2002)“… The algorithm also applies to multi-slice helical 3D reconstruction, and extends to 3D cone-beam reconstruction…”
Získat plný text
Konferenční příspěvek -
19
Fourier- and spline-based approaches for sparse-data problems in medical tomography
ISBN: 9780599973503, 0599973501Vydáno: ProQuest Dissertations & Theses 01.01.2000“… This work develops and evaluates applications of Fourier- and spline-based interpolation and smoothing approaches to some of…”
Získat plný text
Dissertation

