Search Results - "interference pattern analysis"
-
1
The filling factor of the sEMG signal at low contraction forces in the quadriceps muscles is influenced by the thickness of the subcutaneous layer
ISSN: 1664-042X, 1664-042XPublished: Switzerland Frontiers Media SA 05.01.2024Published in Frontiers in Physiology (05.01.2024)“…Introduction: It has been shown that, for male subjects, the sEMG activity at low contraction forces is normally “pulsatile”, i.e., formed by a few…”
Get full text
Journal Article -
2
Sensitivity and specificity of single and combined clouds analyses compared with quantitative motor unit potential analysis
ISSN: 0148-639X, 1097-4598, 1097-4598Published: Hoboken, USA John Wiley & Sons, Inc 01.02.2021Published in Muscle & nerve (01.02.2021)“…Introduction Turns‐amplitude, number of small segments (NSS)‐activity, and envelope‐activity clouds are three methods of electromyography (EMG) interference…”
Get full text
Journal Article -
3
The probability density function of the surface electromyogram and its dependence on contraction force in the vastus lateralis
ISSN: 1475-925X, 1475-925XPublished: London BioMed Central 26.10.2024Published in Biomedical engineering online (26.10.2024)“…Introduction The probability density function (PDF) of the surface electromyogram (sEMG) depends on contraction force. This dependence, however, has so far…”
Get full text
Journal Article -
4
Form factor analysis of the surface electromyographic interference pattern
ISSN: 0148-639X, 1097-4598, 1097-4598Published: Hoboken, USA John Wiley & Sons, Inc 01.08.2020Published in Muscle & nerve (01.08.2020)“…Introduction In contrast to needle electromyography (EMG), surface EMG recordings are painless. It is of interest to develop methods to analyze surface EMG for…”
Get full text
Journal Article -
5
Quantitative Evaluation of Interference Patterns on Electromyography in Neuropathy
ISSN: 1537-7385, 1537-7385Published: United States 01.01.2020Published in American journal of physical medicine & rehabilitation (01.01.2020)“…The aim of this study was to develop a quantitative evaluation method of interference patterns on needle electromyography that is easy to apply in clinical use…”
Get more information
Journal Article -
6
The role of different EMG methods in evaluating myopathy
ISSN: 1388-2457, 1872-8952Published: Shannon Elsevier Ireland Ltd 01.06.2006Published in Clinical neurophysiology (01.06.2006)“…For the diagnosis of myopathy, EMG may have an important role along with blood tests, muscle biopsies and genetic testing. This review evaluates different EMG…”
Get full text
Journal Article -
7
Multi-Motor Unit Potential Analysis and Other Quantitative Techniques for Laryngeal Electromyogram
ISSN: 1537-1603Published: United States 01.08.2015Published in Journal of clinical neurophysiology (01.08.2015)“…Reference values for motor unit potentials of laryngeal muscles, the thyroarytenoid (TA) and cricothyroid (CT) muscles, have been collected using multi-motor…”
Get more information
Journal Article -
8
Quantitative electromyography of the frontalis muscle
ISSN: 1537-1603, 1537-1603Published: United States 01.02.2014Published in Journal of clinical neurophysiology (01.02.2014)“…Identification of abnormal motor unit potentials (MUP), in particular those caused by myopathic processes, is generally difficult in facial muscles because the…”
Get more information
Journal Article -
9
Effects of monopolar and bipolar electrode configurations on surface EMG spike analysis
ISSN: 1350-4533, 1873-4030, 1873-4030Published: Kidlington Elsevier Ltd 01.11.2011Published in Medical engineering & physics (01.11.2011)“…This study compared the effects of monopolar and bipolar electrode configurations on interference pattern analysis of the surface electromyographic (sEMG)…”
Get full text
Journal Article -
10
Electrophysiological characteristics of motor units and muscle fibers in trained and untrained young male subjects
ISSN: 0148-639X, 1097-4598, 1097-4598Published: Hoboken Wiley Subscription Services, Inc., A Wiley Company 01.08.2010Published in Muscle & nerve (01.08.2010)“…We hypothesized that the amplitudes of compound muscle action potentials (CMAPs) and interference pattern analysis (IPA) would be larger in trained subjects…”
Get full text
Journal Article -
11
Analysis of surface EMG spike shape across different levels of isometric force
ISSN: 0165-0270, 1872-678XPublished: Netherlands Elsevier B.V 15.01.2007Published in Journal of neuroscience methods (15.01.2007)“…This research evaluated changes in surface electromyographic (SEMG) spike shape across different levels of isometric force. Ninety-six subjects generated three…”
Get full text
Journal Article -
12
The utility of interference pattern analysis
ISSN: 0148-639X, 1097-4598Published: New York John Wiley & Sons, Inc 01.01.2000Published in Muscle & nerve (01.01.2000)“…The interference pattern of the electrical activity of muscle can be quantified by amplitude measurements, different spike counting methods, and power spectrum…”
Get full text
Journal Article -
13
Effects of evoked pain on the electromyogram and compound muscle action potential of the brachial biceps muscle
ISSN: 0148-639X, 1097-4598Published: Hoboken Wiley Subscription Services, Inc., A Wiley Company 01.01.2005Published in Muscle & nerve (01.01.2005)“…Muscle pain is often accompanied by a feeling of muscle fatigue and weakness. We examined the effect of experimental muscle pain on the electromyogram (EMG)…”
Get full text
Journal Article -
14
Temperature dependency of turn/amplitude parameters
ISSN: 0031-6768Published: 01.06.1996Published in Pflügers Archiv (01.06.1996)“…to assess the influence of the skin and muscle temperatures on the turns per second (T/s) and the amplitude per turn (A/T) and to find out whether…”
Get more information
Journal Article -
15
Liquorpheresis (CSF filtration) in familial amyotrophic lateral sclerosis
ISSN: 1362-4393Published: England 01.08.1999Published in Spinal cord (01.08.1999)“…Liquorpheresis (CSF filtration) has been shown to be of benefit in various neurologic disorders, including sporadic ALS. Liquorpheresis in patients with…”
Get more information
Journal Article -
16
Quantitative electromyography-guided botulinum toxin treatment of cervical dystonia
ISSN: 0362-5664Published: United States 01.02.1997Published in Clinical neuropharmacology (01.02.1997)“…The purpose of this study was to investigate the clinical and electromyographic effect of turn/amplitude analysis (TAA)-guided botulinum toxin administration…”
Get more information
Journal Article -
17
Assessment of different reference limits for turn/amplitude parameters
ISSN: 0148-639XPublished: United States 01.03.1995Published in Muscle & nerve (01.03.1995)Get more information
Journal Article -
18
Sensitivity and specificity of needle electromyography: a prospective study comparing automated interference pattern analysis with single motor unit potential analysis
ISSN: 0924-980X, 0013-4694, 1872-7093Published: Amsterdam Elsevier Ireland Ltd 01.02.1995Published in Electroencephalography and clinical neurophysiology (01.02.1995)“…In this prospective study, automated interference pattern analysis (IPA, “Willison analysis”, modified by Stålberg et al. 1983) was compared to the…”
Get full text
Journal Article -
19
Influence of spontaneous activity on peak-ratio analysis
ISSN: 0013-4694, 1872-6380Published: Ireland Elsevier Ireland Ltd 01.10.1998Published in Electroencephalography and clinical neurophysiology (01.10.1998)“…Objectives: To prove or disprove the assumption that in neuropathy patients with abundant spontaneous activity, peak-ratio interference pattern analysis may…”
Get full text
Journal Article -
20
Automatic decomposition electromyography (ADEMG): validation and normative data in brachial biceps
ISSN: 0013-4694Published: Ireland 01.11.1985Published in Electroencephalography and clinical neurophysiology (01.11.1985)“…We describe a new, automatic method (ADEMG) for decomposing EMG interference patterns into their constituent motor unit action potentials (MUAPs), and…”
Get more information
Journal Article