Výsledky vyhľadávania - "Thresholding algorithm"
-
1
Clinical Evaluation of Swedish Interactive Thresholding Algorithm–Faster Compared With Swedish Interactive Thresholding Algorithm–Standard in Normal Subjects, Glaucoma Suspects, and Patients With Glaucoma
ISSN: 0002-9394, 1879-1891, 1879-1891Vydavateľské údaje: United States Elsevier Inc 01.12.2019Vydané v American journal of ophthalmology (01.12.2019)“…) and the Swedish interactive thresholding algorithm-Faster (SFR) in normal subjects, glaucoma suspects, and patients with glaucoma and to quantify potential time-saving benefits of the SFR algorithm…”
Získať plný text
Journal Article -
2
Diagonal-Newton Fast Iterative Shrinkage-Thresholding Algorithm for Solving Linear Inverse Problems in Image Restoration
ISSN: 2193-567X, 1319-8025, 0377-9211, 2191-4281Vydavateľské údaje: Berlin/Heidelberg Springer Berlin Heidelberg 01.12.2025Vydané v Arabian Journal for Science and Engineering (01.12.2025)“…The Fast Iterative Shrinkage-Thresholding Algorithm (FISTA) is widely used to solve inverse problems arising from various image processing applications…”
Získať plný text
Journal Article -
3
Reconstruction of compressively sampled MR images based on a local shrinkage thresholding algorithm with curvelet transform
ISSN: 0140-0118, 1741-0444, 1741-0444Vydavateľské údaje: Berlin/Heidelberg Springer Berlin Heidelberg 01.10.2019Vydané v Medical & biological engineering & computing (01.10.2019)“…To reduce the magnetic resonance imaging (MRI) data acquisition time and improve the MR image reconstruction performance, reconstruction algorithms based on the iterative shrinkage thresholding algorithm (ISTA) are widely used…”
Získať plný text
Journal Article -
4
Combining CBAM and Iterative Shrinkage-Thresholding Algorithm for Compressive Sensing of Bird Images
ISSN: 2076-3417, 2076-3417Vydavateľské údaje: Basel MDPI AG 01.10.2024Vydané v Applied sciences (01.10.2024)“… This paper introduces a deep neural network based on the Iterative Shrinkage Thresholding Algorithm (ISTA…”
Získať plný text
Journal Article -
5
Comparison of 10-2 and 24-2C Test Grids for Identifying Central Visual Field Defects in Glaucoma and Suspect Patients
ISSN: 1549-4713, 1549-4713Vydavateľské údaje: United States 01.10.2021Vydané v Ophthalmology (Rochester, Minn.) (01.10.2021)“… Each subject underwent perimetric testing using 24-2C SITA-Faster and 10-2 SITA-Fast in random order, and Cirrus OCT macular imaging…”
Zistit podrobnosti o prístupe
Journal Article -
6
Mixed Matrix Completion in Complex Survey Sampling under Heterogeneous Missingness
ISSN: 1061-8600, 1537-2715Vydavateľské údaje: United States Taylor & Francis 01.10.2024Vydané v Journal of computational and graphical statistics (01.10.2024)“… In this work, we consider recovering a mixed dataframe matrix, obtained by complex survey sampling, with entries following different canonical exponential distributions and subject to heterogeneous missingness…”
Získať plný text
Journal Article -
7
The Frontloading Fields Study: The Impact of False Positives and Seeding Point Errors on Visual Field Reliability When Using SITA-Faster
ISSN: 2164-2591, 2164-2591Vydavateľské údaje: United States The Association for Research in Vision and Ophthalmology 01.02.2022Vydané v Translational vision science & technology (01.02.2022)“… (VF) result correlations. There were 2320 intrasession SITA-Faster VF results from 1160 eyes of healthy, glaucoma suspects, and subjects with glaucoma that were separated into "both reliable" or "reliable-unreliable" pairs. VF results…”
Získať plný text
Journal Article -
8
A Nonlinear Penalty Driven Adaptive Thresholding Algorithm for Drowsiness Detection using EEG
Vydavateľské údaje: IEEE 08.12.2021Vydané v 2021 4th International Conference on Bio-Engineering for Smart Technologies (BioSMART) (08.12.2021)“… Drowsiness detection is performed based on a simple thresholding algorithm in which, session dependent…”
Získať plný text
Konferenčný príspevok.. -
9
Comparison of the Humphrey swedish interactive thresholding algorithm (SITA) and full threshold strategies
ISSN: 1057-0829Vydavateľské údaje: United States 01.02.2000Vydané v Journal of glaucoma (01.02.2000)“…To compare the Swedish interactive thresholding algorithm (SITA) strategy with the full threshold strategy in routine clinical practice…”
Zistit podrobnosti o prístupe
Journal Article -
10
Evaluation of the Swedish Interactive Thresholding Algorithm, a new thresholding algorithm, of the Humphrey field analyzer in normal subjects
ISSN: 0029-0203Vydavateľské údaje: Japan 01.06.1998Vydané v Nippon Ganka Gakkai zasshi (01.06.1998)“…The Swedish Interactive Thresholding Algorithm (SITA) is a new thresholding algorithm that aims to obtain the same quality of visual fields in a shorter examination time than with the conventional up-and-down method…”
Zistit podrobnosti o prístupe
Journal Article -
11
Can Swedish interactive thresholding algorithm fast perimetry be used as an alternative to goldmann perimetry in neuro-ophthalmic practice?
ISSN: 0003-9950Vydavateľské údaje: United States 01.09.2002Vydané v Archives of ophthalmology (1960) (01.09.2002)“…To assess the potential role of Swedish Interactive Thresholding Algorithm (SITA) Fast computerized static perimetry, compared with that of Goldmann manual kinetic perimetry…”
Zistit podrobnosti o prístupe
Journal Article -
12
Stepwise suboptimal iterative hard thresholding algorithm for compressive sensing
ISBN: 1457717735, 9781457717734ISSN: 1091-5281Vydavateľské údaje: IEEE 01.05.2012Vydané v 2012 IEEE International Instrumentation and Measurement Technology Conference Proceedings (01.05.2012)“… In this paper, firstly a novel approach was proposed to improve the original IHT algorithm, which is called Orthogonal Iterative Thresholding algorithm…”
Získať plný text
Konferenčný príspevok.. -
13
Glaucoma detection with matrix and standard achromatic perimetry
ISSN: 0007-1161, 1468-2079Vydavateľské údaje: BMA House, Tavistock Square, London, WC1H 9JR BMJ Publishing Group Ltd 01.07.2007Vydané v British journal of ophthalmology (01.07.2007)“… Aim: To compare the performance of matrix and Swedish interactive thresholding algorithm (SITA…”
Získať plný text
Journal Article -
14
A comparison of perimetric results with the Medmont and Humphrey perimeters
ISSN: 0007-1161, 1468-2079Vydavateľské údaje: BMA House, Tavistock Square, London, WC1H 9JR BMJ Publishing Group Ltd 01.06.2003Vydané v British journal of ophthalmology (01.06.2003)“…: To compare these three perimeters, 63 subjects who were glaucoma suspects, ocular hypertensives, glaucoma patients, or normal controls were recruited selectively…”
Získať plný text
Journal Article -
15
Frequency doubling technology perimetry in non-arteritic ischaemic optic neuropathy with altitudinal defects
ISSN: 0007-1161, 1468-2079Vydavateľské údaje: BMA House, Tavistock Square, London, WC1H 9JR BMJ Publishing Group Ltd 01.10.2004Vydané v British journal of ophthalmology (01.10.2004)“… The extent of damage as determined by SAP, FDT, and clinical estimation of the regional extent of optic disc pallor was compared. 10 subjects (20 eyes…”
Získať plný text
Journal Article -
16
Evaluation of a new threshold visual field strategy, SITA, in normal subjects. Swedish Interactive Thresholding Algorithm
ISSN: 1395-3907Vydavateľské údaje: Denmark 01.04.1998Vydané v Acta ophthalmologica Scandinavica (01.04.1998)“…We developed a new family of test algorithms. This is an evaluation in normal subjects…”
Získať plný text
Journal Article -
17
Evaluation of the Agreement between the Three Local Thresholding Algorithms (Otsu’s Local Thresholding Extension, Niblack, and Sauvola) in Choroidal Vascularity Index Measurement Using the ImageJ Software
ISSN: 2523-8973Vydavateľské údaje: Cham Springer International Publishing 06.12.2025Vydané v SN comprehensive clinical medicine (06.12.2025)“…Objective To evaluate the agreement of three different local thresholding algorithms, including…”
Získať plný text
Journal Article -
18
A Strategy for Seeding Point Error Assessment for Retesting (SPEAR) in Perimetry Applied to Normal Subjects, Glaucoma Suspects, and Patients With Glaucoma
ISSN: 0002-9394, 1879-1891, 1879-1891Vydavateľské údaje: United States Elsevier Inc 01.01.2021Vydané v American journal of ophthalmology (01.01.2021)“…) were used to develop models for identifying SPE. Two test cohorts (326 undertaking Swedish interactive thresholding algorithm [SITA…”
Získať plný text
Journal Article -
19
Evaluation of a Change Detection Methodology by Means of Binary Thresholding Algorithms and Informational Fusion Processes
ISSN: 1424-8220, 1424-8220Vydavateľské údaje: Switzerland MDPI AG 01.03.2012Vydané v Sensors (Basel, Switzerland) (01.03.2012)“…Landcover is subject to continuous changes on a wide variety of temporal and spatial scales…”
Získať plný text
Journal Article -
20
A deep joint sparse non-negative matrix factorization framework for identifying the common and subject-specific functional units of tongue motion during speech
ISSN: 1361-8415, 1361-8423, 1361-8423Vydavateľské údaje: Netherlands Elsevier B.V 01.08.2021Vydané v Medical image analysis (01.08.2021)“…•We presented a method to identify both common and subject-specific functional units within a material coordinate system from MRI…”
Získať plný text
Journal Article

