Suchergebnisse - "Teeter, Matthew G."
-
1
Validation of a machine learning technique for segmentation and pose estimation in single plane fluoroscopy
ISSN: 0736-0266, 1554-527X, 1554-527XVeröffentlicht: United States 01.08.2023Veröffentlicht in Journal of orthopaedic research (01.08.2023)“… Kinematics of total knee replacements (TKR) play an important role in assessing the success of a procedure and would be a valuable addition to clinical …”
Volltext
Journal Article -
2
Comparison of Contact Kinematics in Posterior-Stabilized and Cruciate-Retaining Total Knee Arthroplasty at Long-Term Follow-Up
ISSN: 0883-5403, 1532-8406, 1532-8406Veröffentlicht: United States Elsevier Inc 01.01.2020Veröffentlicht in The Journal of arthroplasty (01.01.2020)“… There is controversy regarding the superiority of posterior-stabilizing (PS) total knee arthroplasty (TKA) and cruciate-retaining (CR) TKA. Substantial work …”
Volltext
Journal Article -
3
Assessing implant position and bone properties after cementless total knee arthroplasty using weight-bearing computed tomography
ISSN: 1471-2474, 1471-2474Veröffentlicht: London BioMed Central 15.05.2025Veröffentlicht in BMC musculoskeletal disorders (15.05.2025)“… Background Weight-bearing CT (WBCT) scanners are growing in availability and provide the capability of three-dimensional imaging while a joint is under load …”
Volltext
Journal Article -
4
A multimodal assessment of cementless tibial baseplate fixation using radiography, radiostereometric analysis, and magnetic resonance imaging
ISSN: 0736-0266, 1554-527X, 1554-527XVeröffentlicht: United States 01.01.2024Veröffentlicht in Journal of orthopaedic research (01.01.2024)“… Fixation in cementless total knee arthroplasty is provided by osseous integration. Radiography, radiostereometric analysis (RSA), and magnetic resonance …”
Volltext
Journal Article -
5
Effect of Taper Design on Trunnionosis in Metal on Polyethylene Total Hip Arthroplasty
ISSN: 0883-5403, 1532-8406Veröffentlicht: United States Elsevier Inc 01.07.2015Veröffentlicht in The Journal of arthroplasty (01.07.2015)“… This study examines how taper design affects corrosion and fretting at the head trunnion surface. All hip prostheses retrieved between 1999 and 2013 with …”
Volltext
Journal Article -
6
Trunnionosis: Does Head Size Affect Fretting and Corrosion in Total Hip Arthroplasty?
ISSN: 0883-5403, 1532-8406Veröffentlicht: United States Elsevier Inc 01.10.2016Veröffentlicht in The Journal of arthroplasty (01.10.2016)“… Wear and tribocorrosion at the modular head–neck taper interface may be a cause of failure in metal-on-polyethylene total hip arthroplasty (THA). The present …”
Volltext
Journal Article -
7
Deciphering the low abundance microbiota of presumed aseptic hip and knee implants
ISSN: 1932-6203, 1932-6203Veröffentlicht: San Francisco Public Library of Science 14.09.2021Veröffentlicht in PloS one (14.09.2021)“… 16S rRNA gene sequencing of DNA extracted from clinically uninfected hip and knee implant samples has revealed polymicrobial populations. However, previous …”
Volltext
Journal Article -
8
Early acetabular cup migration may be a source of error in the assessment of intra-operative placement accuracy
ISSN: 2773-157X, 2773-157XVeröffentlicht: Elsevier B.V 01.08.2025Veröffentlicht in Journal of Orthopaedic Reports (01.08.2025)“… Proper alignment of the acetabular cup is essential for long-term success total hip arthroplasty (THA) success. Computer navigation and robotic techniques have …”
Volltext
Journal Article -
9
Monitoring daily shoulder activity before and after reverse total shoulder arthroplasty using inertial measurement units
ISSN: 1058-2746, 1532-6500, 1532-6500Veröffentlicht: United States Elsevier Inc 01.05.2021Veröffentlicht in Journal of shoulder and elbow surgery (01.05.2021)“… The purpose of this study was to use at-home, portable, continuous monitoring technologies to record arm motion and activity preoperatively and postoperatively …”
Volltext
Journal Article -
10
Change in Acetabular Cup Orientation From Supine to Standing Position and Its Effect on Wear of Highly Crosslinked Polyethylene
ISSN: 0883-5403, 1532-8406, 1532-8406Veröffentlicht: United States Elsevier Inc 01.01.2018Veröffentlicht in The Journal of arthroplasty (01.01.2018)“… The purpose of this study is to measure acetabular cup position and wear of the highly crosslinked polyethylene liner in the supine and standing position for …”
Volltext
Journal Article -
11
Do Changes in Patellofemoral Joint Offset Lead to Adverse Outcomes in Total Knee Arthroplasty With Patellar Resurfacing? A Radiographic Review
ISSN: 0883-5403, 1532-8406, 1532-8406Veröffentlicht: United States Elsevier Inc 01.03.2017Veröffentlicht in The Journal of arthroplasty (01.03.2017)“… Patellofemoral joint biomechanics contribute to anterior knee pain, instability, and dysfunction following total knee arthroplasty (TKA). Information about …”
Volltext
Journal Article -
12
Contact Kinematic Differences Between Gap Balanced vs Measured Resection Techniques for Single Radius Posterior-Stabilized Total Knee Arthroplasty
ISSN: 0883-5403, 1532-8406Veröffentlicht: United States Elsevier Inc 01.06.2017Veröffentlicht in The Journal of arthroplasty (01.06.2017)“… Measured resection (MR) and gap balancing (GB) are common surgical techniques for total knee arthroplasty (TKA). Controversy has arisen as each conceptually …”
Volltext
Journal Article -
13
Tribocorrosion: Ceramic and Oxidized Zirconium vs Cobalt-Chromium Heads in Total Hip Arthroplasty
ISSN: 0883-5403, 1532-8406Veröffentlicht: United States Elsevier Inc 01.09.2016Veröffentlicht in The Journal of arthroplasty (01.09.2016)“… This matched-cohort study aims to compare tribocorrosion between matched ceramic and cobalt-chromium femoral head trunnions and between matched Oxinium and …”
Volltext
Journal Article -
14
Inducible Displacement of Cementless Femoral and Tibial Components Throughout Weight-bearing Flexion
ISSN: 2352-3441, 2352-3441Veröffentlicht: United States Elsevier Inc 01.06.2025Veröffentlicht in Arthroplasty today (01.06.2025)“… Cementless fixation for total knee arthroplasty has been increasing following advancements in implant designs. The use of cementless designs has been supported …”
Volltext
Journal Article -
15
Metal-on-Metal Compared With Metal-on-Polyethylene: The Effect on Trunnion Corrosion in Total Hip Arthroplasty
ISSN: 0883-5403, 1532-8406, 1532-8406Veröffentlicht: United States Elsevier Inc 01.08.2017Veröffentlicht in The Journal of arthroplasty (01.08.2017)“… Trunnion tribocorrosion in total hip arthroplasties is concerning, but retrieval studies often are subjective or lack comparison groups. Quantitative …”
Volltext
Journal Article -
16
CORR Insights®: What Is the Long-term Wear of a 5-Mrad Highly Crosslinked Polyethylene Liner? A 14-year RSA Study
ISSN: 1528-1132, 1528-1132Veröffentlicht: United States 01.10.2024Veröffentlicht in Clinical orthopaedics and related research (01.10.2024)Weitere Angaben
Journal Article -
17
Effect of Acetabular Position on Polyethylene Liner Wear Measured Using Simultaneous Biplanar Acquisition
ISSN: 0883-5403, 1532-8406, 1532-8406Veröffentlicht: United States Elsevier Inc 01.05.2017Veröffentlicht in The Journal of arthroplasty (01.05.2017)“… Studies that have previously examined the relationship between acetabular component inclination angle and polyethylene wear have shown increased wear of …”
Volltext
Journal Article -
18
Mechanical wear and oxidative degradation analysis of retrieved ultra high molecular weight polyethylene acetabular cups
ISSN: 1751-6161, 1878-0180, 1878-0180Veröffentlicht: Netherlands 01.03.2018Veröffentlicht in Journal of the mechanical behavior of biomedical materials (01.03.2018)“… The number of revision joint replacements has been increasing substantially over the last few years. Understanding their failure mechanism is extremely …”
Volltext
Journal Article -
19
The Microbial Revolution in the World of Joint Replacement Surgery
ISSN: 2472-7245, 2472-7245Veröffentlicht: United States Journal of Bone and Joint Surgery, Inc 18.04.2024Veröffentlicht in JB & JS open access (18.04.2024)“… Background:The prevalence of revision surgery due to aseptic loosening and periprosthetic joint infection (PJI) following total hip and knee arthroplasty is …”
Volltext
Journal Article -
20
The Impact of Coronal Plane Alignment on Polyethylene Wear and Damage in Total Knee Arthroplasty: A Retrieval Study
ISSN: 0883-5403, 1532-8406, 1532-8406Veröffentlicht: United States Elsevier Inc 01.06.2017Veröffentlicht in The Journal of arthroplasty (01.06.2017)“… Coronal plane alignment is one of the contributing factors to polyethylene wear in total knee arthroplasty. Based on 95 retrieved polyethylene inserts, wear …”
Volltext
Journal Article