  1. 1

    Multi-slice helical CT: Scan and reconstruction von Hu, Hui

    ISSN: 0094-2405, 2473-4209
    Veröffentlicht: United States American Association of Physicists in Medicine 01.01.1999
    Veröffentlicht in Medical physics (Lancaster) (01.01.1999)
    “… It also presents new challenges and new characteristics. In this paper, we study the scan and reconstruction principles of the multi-slice helical CT in general and the 4-slice helical CT in particular …”
    Volltext
    Journal Article
  2. 2

    Algorithm for image reconstruction in multi-slice helical CT von Taguchi, Katsuyuki, Aradate, Hiroshi

    ISSN: 0094-2405, 2473-4209
    Veröffentlicht: United States American Association of Physicists in Medicine 01.04.1998
    Veröffentlicht in Medical physics (Lancaster) (01.04.1998)
    “… Two helical interpolation methods for single-slice CT, 360LI and 180LI, were used as starting points and extended to multi-slice CT …”
    Volltext
    Journal Article
  3. 3

    Analytical models for multi-slice helical CT performance parameters von Hsieh, Jiang

    ISSN: 0094-2405, 2473-4209
    Veröffentlicht: United States American Association of Physicists in Medicine 01.02.2003
    Veröffentlicht in Medical physics (Lancaster) (01.02.2003)
    “… ) and noise performance. In this paper, we derive several closed-form expressions, for linear interpolation based helical reconstruction algorithms, to characterize these performance parameters under different detector …”
    Volltext
    Journal Article
  4. 4

    WE‐A‐301‐11: Low Dose MultiSlice Helical CT Reconstruction Using Tight Frame Regularization von Tian, Z, Jia, X, Dong, B, Lou, Y, Jiang, S

    ISSN: 0094-2405, 2473-4209
    Veröffentlicht: American Association of Physicists in Medicine 01.06.2011
    Veröffentlicht in Medical Physics (01.06.2011)
    “… Purpose: Multislice helical CT has been widely used in CT diagnostic imaging due to its large coverage and short acquisition time …”
    Volltext
    Tagungsbericht Journal Article
  5. 5

    Metal artifact reduction from reformatted projections for hip prostheses in multislice helical computed tomography: techniques and initial clinical results von Yu, Lifeng, Li, Hua, Mueller, Jan, Kofler, James M, Liu, Xin, Primak, Andrew N, Fletcher, Joel G, Guimaraes, Luis S, Macedo, Thanila, McCollough, Cynthia H

    ISSN: 1536-0210, 1536-0210
    Veröffentlicht: United States 01.11.2009
    Veröffentlicht in Investigative radiology (01.11.2009)
    “… The purpose of this work was to develop a projection-based method for reducing metal artifacts caused by hip prostheses in multislice helical CT …”
    Weitere Angaben
    Journal Article
  6. 6

    WE‐D‐332‐07: Automatic Metal Artifact Reduction From Reformatted Projections in MultiSlice Helical CT von Yu, LF, Kofler, JM, Liu, X, Primak, AN, McCollough, CH

    ISSN: 0094-2405, 2473-4209
    Veröffentlicht: American Association of Physicists in Medicine 01.06.2008
    Veröffentlicht in Medical Physics (01.06.2008)
    “… ‐slice helical CT and to evaluate it using clinical data. Method and Materials: The proposed method uses reformatted projections created from helical projection data by combining data at the same angle view over the full longitudinal scan range …”
    Volltext
    Tagungsbericht Journal Article
  7. 7

    ECG-correlated image reconstruction from subsecond multi-slice spiral CT scans of the heart von Kachelrieß, Marc, Ulzheimer, Stefan, Kalender, Willi A.

    ISSN: 0094-2405, 2473-4209
    Veröffentlicht: United States American Association of Physicists in Medicine 01.08.2000
    Veröffentlicht in Medical physics (Lancaster) (01.08.2000)
    “… for imaging the heart with subsecond multi-slice spiral CT utilizing electrocardiogram (ECG) information. The single-slice cardiac z-interpolation algorithms 180 …”
    Volltext
    Journal Article
  8. 8

    Improvement of efficiency and flexibility in multi-slice helical CT von Sun, Wen-wu, Chen, Si-ping, Zhuang, Tian-ge

    ISSN: 1007-1172, 1995-8188
    Veröffentlicht: Heidelberg Shanghai Jiaotong University Press 01.08.2008
    Veröffentlicht in Shanghai jiao tong da xue xue bao (01.08.2008)
    “… The combination of helical scanning with multi-slice CT is a promising approach. Image reconstruction in multi-slice CT becomes, therefore, the major challenge …”
    Volltext
    Journal Article
  9. 9

    The cause of the artifact in 4-slice helical computed tomography von Taguchi, Katsuyuki, Aradate, Hiroshi, Saito, Yasuo, Zmora, Ilan, Han, Kyung S., Silver, Michael D.

    ISSN: 0094-2405, 2473-4209
    Veröffentlicht: United States American Association of Physicists in Medicine 01.07.2004
    Veröffentlicht in Medical physics (Lancaster) (01.07.2004)
    “… ) changeover in pairs of data used in z interpolation, (2) sampling interval in z, and (3) the cone angle. This study analyzes the first two causes of the artifact and describes how the current algorithm …”
    Volltext
    Journal Article
  10. 10

    Reproducibility of multi-slice spiral computed tomography scans:An experimental study von van Straten, Marcel, Venema, Henk W., Hartman, Joris, den Heeten, Gerard J., Grimbergen, Cornelis A.

    ISSN: 0094-2405, 2473-4209
    Veröffentlicht: United States American Association of Physicists in Medicine 01.10.2004
    Veröffentlicht in Medical physics (Lancaster) (01.10.2004)
    “… In multi-slice spiral computed tomography (CT) images interpolation artifacts are present …”
    Volltext
    Journal Article
  11. 11

    Multi-slice helical CT: principles, imaging characteristics, and performance von Hui Hu, He, H.D., Fox, S., Ackelsberg, S., Strong, G., Seidenschnur, G.

    ISBN: 0780351649, 9780780351646
    ISSN: 1094-687X
    Veröffentlicht: IEEE 1998
    “… A 4-slice CT scanner has been developed. Here, the authors outline the principles of multi-slice helical CT in general and 4-slice helical CT in particular …”
    Volltext
    Tagungsbericht
  12. 12

    FFT-based approach to longitudinal interpolation in single- and multi-slice helical CT von Xiaochuan Pan, La Riviere, P.J.

    ISBN: 9780780356962, 0780356969
    ISSN: 1082-3654
    Veröffentlicht: IEEE 1999
    “… Presents an approach to single- and multi-slice helical computed tomography (CT) image reconstruction that exploits the fast Fourier transform (FFT …”
    Volltext
    Tagungsbericht
  13. 13

    A nonlinear helical reconstruction algorithm for multi-slice CT von Hsieh, J.

    ISBN: 9780780365032, 0780365038
    ISSN: 1082-3654
    Veröffentlicht: IEEE 2000
    “… In this paper, we propose a new helical reconstruction algorithm for multi-slice helical CT. To avoid discontinuity in the helical weighting function, a double cone shaped region is selected as the POR …”
    Volltext
    Tagungsbericht
  14. 14

    A multi-slice helical CT reconstruction with generalized weighting von Hsieh, J., Toth, T., Simoni, P., Slack, C., Grekowicz, B., Seidenschnur, G., Wang, S.

    ISBN: 9780780373242, 0780373243
    ISSN: 1082-3654
    Veröffentlicht: IEEE 2001
    “… Multi-slice computed tomography (MCT) is one of the most recent technology advancements in CT …”
    Volltext
    Tagungsbericht
  15. 15

    Reconstruction Algorithm with Improved Efficiency and Flexibility in Multi-Slice Spiral CT von Sun, Wenwu, Chen, Siping, Zhuang, Tiange

    ISBN: 0780387414, 9780780387416
    ISSN: 1094-687X, 1557-170X
    Veröffentlicht: United States IEEE 2005
    “… The combination of spiral scanning with multi-slice CT is a promising approach. The algorithm of image reconstruction for multi-slice spiral CT becomes, therefore, the main challenge …”
    Volltext
    Tagungsbericht Journal Article
  16. 16

    A detector response adaptive helical reconstruction algorithm von Hsieh, J., Li, J.

    ISBN: 9780780365032, 0780365038
    ISSN: 1082-3654
    Veröffentlicht: IEEE 2000
    “… With the recent introduction of multi-slice CT (MCT) by many CT manufactures, research on the subject of multi-slice helical reconstruction has gained significant interests …”
    Volltext
    Tagungsbericht
  17. 17

    Feldkamp-type image reconstruction from equiangular data von Wang, B, Liu, H, Zhao, S, Wang, G

    ISSN: 0895-3996
    Veröffentlicht: Netherlands 2001
    Veröffentlicht in Journal of X-ray science and technology (2001)
    “… Previously, the traditional practical cone-beam reconstruction method, the Feldkamp algorithm, was generalized into the case of spiral/helical scanning loci with equispatial cone-beam projection data …”
    Weitere Angaben
    Journal Article
  18. 18

    O(N/sup 2/ log N) native fan-beam tomographic reconstruction von Shu Xiao, Bresler, Y., Munson, D.C.

    ISBN: 078037584X, 9780780375840
    Veröffentlicht: IEEE 2002
    “… The algorithm also applies to multi-slice helical 3D reconstruction, and extends to 3D cone-beam reconstruction …”
    Volltext
    Tagungsbericht
  19. 19

    Fourier- and spline-based approaches for sparse-data problems in medical tomography von La Riviere, Patrick Jean

    ISBN: 9780599973503, 0599973501
    Veröffentlicht: ProQuest Dissertations & Theses 01.01.2000
    “… This work develops and evaluates applications of Fourier- and spline-based interpolation and smoothing approaches to some of …”
    Volltext
    Dissertation